Laboratory measurement of the P(2,1) submillimeter transition frequency of H3O(+)

The molecular ion H3O(+) is predicted to be an important component of the gas phase of interstellar clouds where it is calculated to be one of the most abundant molecular ions. Its detection would provide an indirect method of determining the abundance of the crucial species H2O. This fundamental molecule has no convenient low-lying transitions in the microwave or millimeter regions of the spectrum which can be excited under the normal low temperature conditions present in the interstellar medium. It is believed that the P(2,1) transition of H3O(+) in absorption at a frequency of 307 192.41 (5) MHz has been detected. The H3O(+) ion was produced in a magnetically enhanced negative glow discharge source.

Plummer, G. M.↗

Electronic Tongue for Quantitation of Contaminants in Water

An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.

Buehler, Marlin↗

CADIS and FW-CADIS Variance Reduction in Gamma Transport for Predicting Prompt Forensics Signatures

The goal of prompt nuclear forensics is to determine the characteristics of a nuclear detonation based on the signatures available almost immediately after the explosion. An important characteristic is the reaction time history (RTH), a measure of the device’s rate of neutron multiplication. The RTH can be estimated by observation of the gamma radiation emitted from the detonation, which can be detected directly or observed indirectly as Teller light. Gamma transport simulations used to predict these radiation fields are often modeled stochastically using the Monte Carlo N-Particle (MCNP) code, which can be a computationally demanding task due to the number of particle histories needed to achieve statistical convergence. In an attempt to improve the efficiency of these calculations, we evaluate two variance reduction techniques: Consistent Adjoint-Driven Importance Sampling (CADIS) and Forward-Weighted Consistent Adjoint-Driven Importance Sampling (FW-CADIS). These methods use a deterministically calculated adjoint flux to create weight windows and source biasing that guide MCNP sampling. We study the utility of CADIS and FW-CADIS for their use in MCNP gamma transport for nuclear forensics prediction simulations. Furthermore, the results demonstrate that both CADIS and FW-CADIS improve the accuracy for forensics-focused simulations, with CADIS being most beneficial in direct detection and FW-CADIS being ideal for computing a global Teller light source.

CADIS↗

Status of the Terrestrial Planet Finder Interferometer (TPF-I)

The interferometric version of the Terrestrial Planet Finder (TPF-I) has the potential to find and characterize earth-sized planets in the habitable zones of over 250 nearby stars and to search for life using biomarkers in the atmospheres of any planets found. The scientific case for such a mission continues to be strengthened by on-going progress in the detection of planets via indirect means. This paper summarizes the status of TPF-I, illustrative scientific requirements for the mission, and its enabling technologies.

Terrestrial Planet Finder (TPF)↗

Electronic Tongue Containing Redox and Conductivity Sensors

The Electronic Tongue (E-tongue 2) is an assembly of sensors for measuring concentrations of metal ions and possibly other contaminants in water. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings, and detecting micro-organisms indirectly by measuring microbially influenced corrosion. The device includes a heater, a temperature sensor, an oxidation/reduction (redox) sensor pair, an electrical sensor, an array of eight galvanic cells, and eight ion-specific electrodes.

Buehler, Martin↗

Probing boron vacancy defects in hBN via single spin relaxometry

Spin defects in solids offer promising platforms for quantum sensing and memory due to their long coherence times and optical addressability. Here, we integrate a single nitrogen-vacancy (NV) center in diamond with scanning probe microscopy to detect, read out, and spatially map spin-based quantum sensors at the nanoscale. Using the boron vacancy ($V$$^{–}_{B}$) center in hexagonal boron nitride—an emerging two-dimensional spin system—as a model, we detect its electron spin resonance indirectly via changes in the spin relaxation time (T 1 ) of a nearby NV center, eliminating the need for optical excitation or fluorescence detection of the $V$$^{–}_{B}$. Cross-relaxation between NV and $V$$^{–}_{B}$ ensembles significantly reduces NV T1, enabling quantitative nanoscale mapping of defect densities beyond the optical diffraction limit and clear resolution of hyperfine splitting in isotopically enriched h 10 B 15 N. Our method demonstrates interactions between spin sensors in 3D and 2D materials, establishing NV centers as versatile probes for characterizing otherwise inaccessible spin defects.

Quantum metrology↗

Indirect searches for dark matter bound state formation and level transitions

Indirect searches for dark matter (DM) have conventionally been applied to the products of DM annihilation or decay. If DM couples to light force carriers, however, it can be captured into bound states via dissipation of energy that may yield detectable signals. We extend the indirect searches to DM bound state formation and transitions between bound levels, and constrain the emission of unstable dark photons. Our results significantly refine the predicted signal flux that could be observed in experiments. As a concrete example, we use Fermi-LAT dwarf spheroidal observations to obtain constraints in terms of the dark photon mass and energy which we use to search for the formation of stable or unstable bound states.

Baldes, Iason↗

Assessment Study of the State of the Art in Adaptive Control and its Applications to Aircraft Control

Many papers relevant to reconfigurable flight control have appeared over the past fifteen years. In general these have consisted of theoretical issues, simulation experiments, and in some cases, actual flight tests. Results indicate that reconfiguration of flight controls is certainly feasible for a wide class of failures. However many of the proposed procedures although quite attractive, need further analytical and experimental studies for meaningful validation. Many procedures assume the availability of failure detection and identification logic that will supply adequately fast, the dynamics corresponding to the failed aircraft. This in general implies that the failure detection and fault identification logic must have access to all possible anticipated faults and the corresponding dynamical equations of motion. Unless some sort of explicit on line parameter identification is included, the computational demands could possibly be too excessive. This suggests the need for some form of adaptive control, either by itself as the prime procedure for control reconfiguration or in conjunction with the failure detection logic. If explicit or indirect adaptive control is used, then it is important that the identified models be such that the corresponding computed controls deliver adequate performance to the actual aircraft. Unknown changes in trim should be modelled, and parameter identification needs to be adequately insensitive to noise and at the same time capable of tracking abrupt changes. If however, both failure detection and system parameter identification turn out to be too time consuming in an emergency situation, then the concepts of direct adaptive control should be considered. If direct model reference adaptive control is to be used (on a linear model) with stability assurances, then a positive real or passivity condition needs to be satisfied for all possible configurations. This condition is often satisfied with a feedforward compensator around the plant. This compensator must be robustly designed such that the compensated plant satisfies the required positive real conditions over all expected parameter values. Furthermore, with the feedforward only around the plant, a nonzero (but bounded error) will exist in steady state between the plant and model outputs. This error can be removed by placing the compensator also in the reference model. Design of such a compensator should not be too difficult a problem since for flight control it is generally possible to feedback all the system states.

Kaufman, Howard↗

Evaluation of an in vitro three-dimensional HepaRG spheroid model for genotoxicity testing using the high-throughput CometChip platform

Three-dimensional (3D) culture systems are increasingly being used for genotoxicity studies due to improved cell-to-cell interactions and tissue-like structures that are limited or lacking in 2D cultures. The present study optimized a 3D culture system using metabolically competent HepaRG cells for in vitro genotoxicity testing. 3D HepaRG spheroids, formed in 96- or 384-well ultra-low attachment plates, were exposed to various concentrations of 34 test articles, including 8 direct-acting and 11 indirect-acting genotoxicants/carcinogens as well as 15 compounds that show different genotoxic responses in vitro and in vivo. DNA damage was evaluated using the high-throughput CometChip assay with concurrent cytotoxicity assessment by the ATP assay in both 2D and 3D cultures. 3D HepaRG spheroids maintained a stable phenotype for up to 30 days with higher levels of albumin secretion, cytochrome P450 gene expression, and enzyme activities compared to 2D cultures. 3D spheroids also demonstrated a higher sensitivity than 2D cultures for detecting both direct- and indirect-acting genotoxicants/carcinogens, indicating a better prediction of in vivo genotoxicity responses. When DNA damage dose-response data were quantified using PROAST software, 3D spheroids generally had lower or similar benchmark dose values compared to 2D HepaRG cells and were more comparable with primary human hepatocytes. These results demonstrate that 3D models can be adapted to the CometChip technology for high-throughput genotoxicity testing and that 3D HepaRG spheroids may be used as a reliable and pragmatic in vitro approach to better support the hazard identification and risk assessment of potential human genotoxic carcinogens.

60 APPLIED LIFE SCIENCES↗

The Martian sedimentary record

The differences between the surface geology of Mars and earth are discussed. Sedimentary processes and fluvial systems on Mars are examined. Surface mapping reveals the more recent depostional patterns. In future missions, radar sounding, active seismic systems, and on site deep drilling may be required to fully document the depositional history. For the present, identification of sedimentary layers must rest on localities of tectonic or erosional windows, detection of buried surfaces by indirect methods, and deposition or off lap patterns of distribution.

Dehon, R. A.↗

Integrated hydrogeophysical modelling and data assimilation for geoelectrical leak detection

Time-lapse electrical resistivity tomography (ERT) measurements provide indirect observations of hydrological processes in the Earth's shallow subsurface at high spatial and temporal resolution. ERT has been used in the past decades to detect leaks and monitor the evolution of associated contaminant plumes. Specifically, inverted resistivity images allow visualization of the dynamic changes in the structure of the plume. However, existing methods do not allow the direct estimation of leak parameters (e.g. leak rate, location, etc.) and their uncertainties. We propose an ensemble-based data assimilation framework that evaluates proposed hydrological models against observed time-lapse ERT measurements without directly inverting for the resistivities. Each proposed hydrological model is run through the parallel coupled hydro-geophysical simulation code PFLOTRAN-E4D to obtain simulated ERT measurements. The ensemble of model proposals is then updated using an iterative ensemble smoother. In this paper, we demonstrate the proposed framework on synthetic and field ERT data from controlled tracer injection experiments. Our results show that the approach allows joint identification of contaminant source location, initial release time, and solute loading from the cross-borehole time-lapse ERT data, alongside with an assessment of uncertainties in these estimates. We demonstrate a reduction in site-wide uncertainty by comparing the prior and posterior plume mass discharges at a selected image plane. This framework is particularly attractive to sites that have previously undergone extensive geological investigation (e.g., nuclear sites). It is well suited to complement ERT imaging and we discuss practical issues in its application to field problems.

58 GEOSCIENCES↗

Pulmonary-impedance power spectral analysis: A facile means of detecting radiation-induced gastrointestinal distress and performance decrement in man

Changes in respiratory variance revealed by power spectral analysis of the pulmonary impedance pneumogram can be used to detect and measure stresses directly or indirectly affecting human respiratory function. When gastrointestinal distress occurred during a series of 5 total-body exposures of 30 R at a rate of 1.5 R/min, it was accompanied by typical shifts in pulmonary impedance power spectra. These changes did not occur after protracted exposure of 250 R (30 R daily) at 1.5 R/hr that failed to cause radiation sickness. This system for quantitating respiratory effort can also be used to detect alterations in one's ability to perform under controlled exercise conditions.

Rick, R. C.↗

Proton-detected solid-state NMR spectroscopy of spin-1/2 nuclei with large chemical shift anisotropy

Constant-time (CT) dipolar heteronuclear multiple quantum coherence (D-HMQC) has previously been demonstrated as a method for proton detection of high-resolution wideline NMR spectra of spin-1/2 nuclei with large chemical shift anisotropy (CSA). However, 1 H transverse relaxation and t 1 -noise often reduce the sensitivity of D-HMQC experiments, preventing the theoretical gains in sensitivity provided by 1 H detection from being realized. In this paper, we demonstrate a series of improved pulse sequences for 1 H detection of spin-1/2 nuclei under fast MAS, with 195 Pt SSNMR experiments on cisplatin as an example. First, a t 1 -incrementation protocol for D-HMQC dubbed Arbitrary Indirect Dwell (AID) is demonstrated. AID allows the use of arbitrary, rotor asynchronous t 1 -increments, but removes the constant time period from CT D-HMQC, resulting in improved sensitivity by reducing transverse relaxation losses. Next, we show that short high-power adiabatic pulses (SHAPs), which efficiently invert broad MAS sideband manifolds, can be effectively incorporated into 1 H detected symmetry-based resonance echo double resonance (S-REDOR) and t 1 -noise eliminated (TONE) D-HMQC experiments. The S-REDOR experiments with SHAPs provide approximately double the dipolar dephasing, as compared to experiments with rectangular inversion pulses. We lastly show that sensitivity and resolution can be further enhanced with the use of swept excitation pulses as well as adiabatic magic angle turning (aMAT).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiolytic degradation of n -dodecane: Insights from time resolved pulsed electron radiolysis using aromatic scavengers

This study uses time-resolved picosecond pulsed electron radiolysis and transient absorbance spectroscopy to investigate early radiolytic processes in n-dodecane, a prototypical organic solvent for reprocessing used nuclear fuel (UNF). The primary radical cation, solvated electron, and excited states in neat n-dodecane are formed and consumed on timescales that are difficult to observe directly. Aromatic solutes, biphenyl and benzophenone, were utilized as scavengers to convert these short-lived species into longer-lived, optically detectable transient products to serve as indirect probes of the fraction of the initial n-dodecane radiolytic products that can be intercepted before undergoing ultrafast decay or competing reactions. The transient absorbance spectra of these scavengers and their radiolytic products were analyzed. Results indicate that while biphenyl and benzophenone effectively capture several radiolytic species, they do not fully scavenge all n-dodecane excited states, suggesting potential inefficiencies or additional side reactions. This study provides insight into the formation and accessibility of radiation-induced excited states and charge carriers in n-dodecane, which play a key role in the degradation of solvent extraction systems used in UNF reprocessing.

58 GEOSCIENCES↗

Fourier transform infrared studies of the interaction of HCl with model polar stratospheric cloud films

Heterogeneous reactions involving hydrochloric acid adsorbed on the surfaces of polar stratospheric clouds (PSCs) are postulated to contribute to polar ozone loss. Using FTIR spectroscopy to probe the condensed phase, we have examined the interaction of HCl with ice and nitric acid trihydrate (NAT) films representative of types II and I PSCs, respectively. For HCl pressures in the range of 10 exp -7 to 10 exp -5 Torr, our FTIR studies show that a small amount of crystalline HCl-6H2O formed on or in ice at 155 K. However, for higher HCl pressures, we observed that the entire film of ice rapidly converted into an amorphous 4:1 H2O:HCl mixture. From HCl-uptake experiments with P(HCl) = 8 x 10 exp -7 Torr, we estimate roughly that the diffusion coefficient of HCl in ice is around 2 x 10 exp -12 sq cm/s at 158 K. For higher temperatures more closely approximating those found in the stratosphere, we were unable to detect bulk HCl uptake by ice. Indirect evidence suggests that HCl adsorption onto the surface of model PSC films inhibited the evaporation of both ice and NAT by 3-5 K.

Koehler, Birgit G.↗

Science camera calibration for extreme adaptive optics

The nascent field of planet detection has yielded a host of extra-solar planet detections. To date, these detections have been the result of indirect techniques: the planet is inferred by precisely measuring its effect on the host star. Direct observation of extra-solar planets remains a challenging yet compelling goal. In this vein, the Center for Adaptive Optics has proposed a ground-based, high-actuator density extreme A0 system (XAOPI), for a large (~10 m) telescope whose ultimate goal is to directly evidence a specific class of these objects: young and massive planets. Detailed system wave-front error budgets suggest that this system is a feasible, if not an ambitious, proposition. One key element in this error budget is the calibration and maintenance of the science camera wave front with respect to the wave-front sensor which currently as an allowable contribution of ~ 5 nanometers rms. This talk first summarizes the current status of calibration on existing ground-based A0 systems, the magnitude of this effect in the system error budget and current techniques for mitigation. Subsequently, we will explore the nature of this calibration error term, it's source in the non-commonality between the science camera and wave front sensor, and the effect of the temporal evolution of non-commonality. Finally, we will describe preliminary plans for sensing and controlling this error term. The sensing techniques include phase retrieval, phase contrast and external metrology. To conclude, a calibration scenario that meets the stringent requirement for XAOPI will be discussed.

MacIntosh, Bruce↗

Higher-Sensitivity Ionization Trace-Species Detector

Electron source and electron optics of reversal electron-attachment detector modified to increase sensitivity. Original version described in "High-Sensitivity Ionization Trace-Species Detector" (NPO-17596). Used to detect molecules of particular chemical species of interest (e.g., narcotics, explosives, or organic wastes) present in air at low concentrations, and known to attach extremely low-energy electrons. Apparatus does this by ionizing molecules from sampled atmosphere, then detecting ions of species of interest. Detector features indirectly heated spherical cathode and redesigned electron optics, together, deliver more electrons at low kinetic energy to reversal plane, R. Greater electron current generates more ions for detection.

Boumsellek, Said↗

Automatic multi-banking of memory for microprocessors

A microprocessor system is provided with added memories to expand its address spaces beyond its address word length capacity by using indirect addressing instructions of a type having a detectable operations code and dedicating designated address spaces of memory to each of the added memories, one space to a memory. By decoding each operations code of instructions read from main memory into a decoder to identify indirect addressing instructions of the specified type, and then decoding the address that follows in a decoder to determine which added memory is associated therewith, the associated added memory is selectively enabled through a unit while the main memory is disabled to permit the instruction to be executed on the location to which the effective address of the indirect address instruction points, either before the indirect address is read from main memory or afterwards, depending on how the system is arranged by a switch.

Wiker, G. A.↗