Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “incident visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Transmission of radiometer data from the Synchronous Meteorological Satellite

The Synchronous Meteorological Satellite uses a spin scanner radiometer which generates eight visual signals and two infrared signals. These signals are multiplexed and converted into a 28-Mbps data stream. This signal is transmitted to ground by quadriphase modulation at 1686.1 MHz. On the ground, the digital signal is reconstructed to an analog signal. To conserve bandwidth, an analog-to-digital converter with a nonlinear transfer function was used for the visual signals. The size of the quantization step was made proportional to the noise output of the scanner photomultiplier tube which increases as the square root of incident light. The radiometer data transmission link was simulated on a digital computer to determine the transfer function. Some results of the simulation are shown.

Davies, R. S.↗

Disaster Response Modeling Through Discrete-Event Simulation

Organizations today are required to plan against a rapidly changing, high-cost environment. This is especially true for first responders to disasters and other incidents, where critical decisions must be made in a timely manner to save lives and resources. Discrete-event simulations enable organizations to make better decisions by visualizing complex processes and the impact of proposed changes before they are implemented. A discrete-event simulation using Simio software has been developed to effectively analyze and quantify the imagery capabilities of domestic aviation resources conducting relief missions. This approach has helped synthesize large amounts of data to better visualize process flows, manage resources, and pinpoint capability gaps and shortfalls in disaster response scenarios. Simulation outputs and results have supported decision makers in the understanding of high risk locations, key resource placement, and the effectiveness of proposed improvements.

Wang, Jeffrey↗

Visual light flash phenomenon, part C

The Apollo 16 mission provided the opportunity to obtain additional data on the characteristics and frequency of the light flashes and also provided the first opportunity to obtain a direct physical record of incident cosmic ray particles with the Apollo light flash moving emulsion detector (ALFMED). The ALFMED is an electromechanical device that is worn on the head like a helmet and supports cosmic radiation-sensitive emulsions around the head of the test subject. Two light flash observation sessions were conducted during the mission: one during translunar coast and the second during transearth coast. Characteristics of the light flashes observed and reported by the Apollo crew members were generally similar to those reported on previous missions. Analyses of the ALFMED emulsion plates are proceeding as scheduled, although results are not yet available. The ALFMED results should provide conclusive evidence establishing the correlation, if any, between the incident cosmic ray particles and the perception of light flashes as reported by Apollo crew members.

Richard E. Benson↗

Free vorticity field-boundary layer conversions: Effect of boundary configuration and scale

Progress was made on further flow visualization of vortex-leading edge interaction, in conjunction with characterization of the unsteady pressure field. The range of scale of an elliptical leading edge, relative to the incident primary vortex, was determined. The scale of the incident vortex was characterized in terms of mean shear layer parameters. An overview of the interaction mechanism for the range of thin to thick leading-edges is given. The interaction mechanism corresponding to the case where the incident vortex is above the leading-edge is given for hydrogen bubble wires well upstream of and at the tip of the leading edge. A sample of the instantaneous pressure distribution for the case where the incident vortex dives beneath the edge is presented. The effect of scale of the incident vortex relative to that of the leading-edge was examined. The circulation and length scale of the incident vortices in the street are being characterized.

Rockwell, D.↗

A new synchrotron rapid-scanning X-ray fluorescence (SRS-XRF) imaging station at SSRL beamline 6-2

This paper describes a new large-range rapid-scan X-ray fluorescence (XRF) imaging station at beamline 6-2 at the Stanford Synchrotron Radiation Lightsource at SLAC National Accelerator Laboratory. This station uses a continuous rapid-scan system with a scan range of 1000 × 600 mm and a load capacity of up to 25 kg, capable of 25–100 µm resolution elemental XRF mapping and X-ray absorption spectroscopy (XAS) of a wide range of objects. XRF is measured using a four-element Hitachi Vortex ME4 silicon drift detector coupled to a Quantum Detectors Xspress3 multi-channel analyzer system. A custom system allows the X-ray spot size to be changed quickly and easily via pinholes ranging from 25 to 100 µm, and the use of a poly-capillary or axially symmetric achromatic optic may achieve a <10 µm resolution in the future. The instrument is located at wiggler beamline 6-2 which has an energy range of 2.1–17 keV, creating K emission for elements up to strontium, and L or M emission for all other elements. XAS can also be performed at selected sample positions within the same experiment, allowing for a more detailed chemical characterization of the elements of interest. Furthermore, sparse excitation energy XRF imaging can be performed over a wide range of incident X-ray energies. User friendliness has been emphasized in all stages of the experiment, including versatile sample mounts, He purged chambers for low- Z analyses, and intuitive visualization hardware and software. The station provides analysis capabilities for a wide range of materials and research fields including biological, chemical, environmental and materials science, paleontology, geology and cultural heritage.

47 OTHER INSTRUMENTATION↗

MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast exposure time allowable under FDA standards. Department of Defense (DOD) Breast Cancer Research Program IDEA Award W81XWH-11-1-0332; National Institutes of Health (NIH) Grant T32 EB002103-21 from the National Institute of Biomedical Imaging and Bioengineering (NIBIB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical ellipsometry: Analysis of thin metal layers using n-k-d twisted curve methods with multiple incidence angles

A major challenge for those utilizing ellipsometry is numerical processing of the measured data. The transcendental, multivalued equations arising from the physics of simple reflection are problematic for the least-squares numerical methods in common use. These early numerical methods require fairly accurate initial estimates, bounding to avoid local minima, and only find solutions at the bottom of a relatively flat numerical topography. Previously the authors have applied complex analysis in the n-k plane to improve visualization of the mathematics, and this has led to a growing array of new numerical methods avoiding these difficulties. The work presented here extends these new numerical methods to three dimensions (n-k-d space) for use with absorbing films deposited on transparent and on absorbing substrates. The method finds intersections of three ''twisted curves'' resulting from three (or more) light incidence angle measurements per wavelength. The method is employed here to determine the thickness and optical properties of chromium films (between 10 and 25 nm nominal thickness) deposited onto two different substrates, silicon and silica oxide, employing measurements made at three different angles of incidence for light wavelengths between 280 and 2500 nm.

36 MATERIALS SCIENCE↗

Visual phenomena of surface plasmon polaritons at the dielectric-plasma interface

Some interesting experiment phenomena of light patterns that appear in microwave plasma have been investigated. The wavelength of surface plasmon polaritons (SPPs) at the dielectric-plasma interface as the functions of incident wave frequency and plasma density has been calculated. The comparison of the experiment results with the calculating results has been carried out. By experimentally and theoretically analyzing, the phenomena are considered to be caused by the surface wave of SPPs at the interface between Pyrex wall and plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Daylight performance of a microstructured prismatic window film in deep open plan offices

Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Here, a microstructured prismatic film designed for such use was characterized using goniophotometric measurements and ray tracing simulations. The synthetically-generated bidirectional scattering distribution function (BSDF) data were shown to have good agreement with limited measured data for normal incident angles (0–60°). Measured data indicated that the prismatic film was most efficient when vertical angles of incidence were between 18 and 35° and within ±45° of normal incidence to the plane of the window so maximum energy savings across the full depth of the zone occurred over the equinox to winter solstice period. Annual lighting energy use and visual comfort in a deep open plan office zone were evaluated using the Radiance three-phase method in several climates and for south and east-facing window orientations. Lighting energy savings were 39–43% for a 12 m (40 ft) deep south-facing perimeter zone compared to the same zone with no lighting controls. The prismatic film with and without a diffuser controlled glare for views parallel to the window but produced glare for seated viewpoints looking toward the window. At mature market costs, the system was projected to have a simple payback of 2–6 years. Technical challenges encountered throughout the evaluation led to improvements in measurement and modeling tools and stressed the importance of having accurate input data for product development.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Installation of soft X-ray array diagnostics and its application to tomography reconstruction using synthetic KSTAR X-ray images

Four-array system of soft X-ray diagnostics was installed on KSTAR tokamak. Each array has 32 viewing chords of two photo-diode array detectors with spatial resolution of 2 cm. To estimate signals from the soft X-ray radiation power, typical n{sub e}, T{sub e}, and argon impurity line radiation profiles in KSTAR are chosen. The photo-diodes were absolutely calibrated as a function of the incident photon energy in 2–40 keV range with a portable X-ray tube. Two-dimensional T{sub e} image properties by multi-energy method were simulated and visualized with six combinations of beryllium filter sets within the dynamic range of signal ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

After Action Report: Idaho National Laboratory Continuity of Operations Program 2017 Exercise September 26, 2017

On September 26, 2017, the Battelle Energy Alliance, LLC (BEA) Continuity of Operations Program (COOP) conducted an annual exercise to demonstrate the COOP responder’s ability to maintain COOP’s primary mission essential function (PMEF) and essential supporting activities (ESAs) during a national loss of commercial power caused by a malware attack to the United States power grid. The continuity emergency management team (CEMT) and continuity emergency response group (CERG) responded to CERG notifications and worked through simulated challenges, using COOP’s 3-D scenario visualization tool (3DSVT), that challenged COOP’s PMEF, essential support activities (ESAs), and impacted mission critical personnel’s human capital. The PMEF and ESAs were successfully maintained as the CERG developed incident action plans through several phases of the scenario, addressing appropriate needs, concerns and strategic planning.

99 GENERAL AND MISCELLANEOUS↗

Effects of electron irradiation on large insulating surfaces used for European Communications Satellites

Samples of aluminized Kapton used for passive thermal control on the VHF shield and the antenna dish of ESA's OTS satellite and its derivatives were subjected to an incident electron beam of 25 keV and irradiated for 8 hours at room temperature and at -173 C under a vacuum of the 10 to the minus 6 th power torr. Visual observations during electron irradiation, measurements of leakage current and discharge characteristics, and material degradation following completion of irradiation are discussed.

Reddy, J.↗

Risk-Based Causal Modeling of Airborne Loss of Separation

Maintaining safe separation between aircraft remains one of the key aviation challenges as the Next Generation Air Transportation System (NextGen) emerges. The goals of the NextGen are to increase capacity and reduce flight delays to meet the aviation demand growth through the 2025 time frame while maintaining safety and efficiency. The envisioned NextGen is expected to enable high air traffic density, diverse fleet operations in the airspace, and a decrease in separation distance. All of these factors contribute to the potential for Loss of Separation (LOS) between aircraft. LOS is a precursor to a potential mid-air collision (MAC). The NASA Airspace Operations and Safety Program (AOSP) is committed to developing aircraft separation assurance concepts and technologies to mitigate LOS instances, therefore, preventing MAC. This paper focuses on the analysis of causal and contributing factors of LOS accidents and incidents leading to MAC occurrences. Mid-air collisions among large commercial aircraft are rare in the past decade, therefore, the LOS instances in this study are for general aviation using visual flight rules in the years 2000-2010. The study includes the investigation of causal paths leading to LOS, and the development of the Airborne Loss of Separation Analysis Model (ALOSAM) using Bayesian Belief Networks (BBN) to capture the multi-dependent relations of causal factors. The ALOSAM is currently a qualitative model, although further development could lead to a quantitative model. ALOSAM could then be used to perform impact analysis of concepts and technologies in the AOSP portfolio on the reduction of LOS risk.

Geuther, Steven C.↗

Probing three-dimensional mesoscopic interfacial structures in a single view using multibeam X-ray coherent surface scattering and holography imaging

Abstract Visualizing surface-supported and buried planar mesoscale structures, such as nanoelectronics, ultrathin-film quantum dots, photovoltaics, and heterogeneous catalysts, often requires high-resolution X-ray imaging and scattering. Here, we discovered that multibeam scattering in grazing-incident reflection geometry is sensitive to three-dimensional (3D) structures in a single view, which is difficult in conventional scattering or imaging approaches. We developed a 3D finite-element-based multibeam-scattering analysis to decode the heterogeneous electric-field distribution and to faithfully reproduce the complex scattering and surface features. This approach further leads to the demonstration of hard-X-ray Lloyd’s mirror interference of scattering waves, resembling dark-field, high-contrast surface holography under the grazing-angle scattering conditions. A first-principles calculation of the single-view holographic images resolves the surface patterns’ 3D morphology with nanometer resolutions, which is critical for ultrafine nanocircuit metrology. The holographic method and simulations pave the way for single-shot structural characterization for visualizing irreversible and morphology-transforming physical and chemical processes in situ or operando .

47 OTHER INSTRUMENTATION↗

WISE Detections of Dust in the Habitable Zones of Planet-Bearing Stars

We use data from the Wide-field Infrared Survey Explorer (WISE) all-sky release to explore the incidence of warm dust in the habitable zones around exoplanet-host stars. Dust emission at 12 and/or 22 microns (T(sub dust) approx.300 and/or approx.150 K) traces events in the terrestrial planet zones; its existence implies replenishment by evaporation of comets or collisions of asteroids, possibly stirred by larger planets. Of the 591 planetary systems (728 extrasolar planets) in the Exoplanet Encyclopedia as of 2012 January 31, 350 are robustly detected by WISE at > or = 5(sigma) level. We perform detailed photosphere subtraction using tools developed for Spitzer data and visually inspect all the WISE images to confirm bona fide point sources. We find nine planet-bearing stars show dust excess emission at 12 and/or 22 microns at > or = 3(sigma) level around young, main-sequence, or evolved giant stars. Overall, our results yield an excess incidence of approx.2.6% for stars of all evolutionary stages, but approx.1% for planetary debris disks around main-sequence stars. Besides recovering previously known warm systems, we identify one new excess candidate around the young star UScoCTIO 108.

Morales, Farisa Y.↗

WISE DETECTIONS OF DUST IN THE HABITABLE ZONES OF PLANET-BEARING STARS

We use data from the Wide-field Infrared Survey Explorer (WISE) all-sky release to explore the incidence of warm dust in the habitable zones around exoplanet-host stars. Dust emission at 12 and/or 22 {mu}m (T{sub dust} {approx} 300 and/or {approx}150 K) traces events in the terrestrial planet zones; its existence implies replenishment by evaporation of comets or collisions of asteroids, possibly stirred by larger planets. Of the 591 planetary systems (728 extrasolar planets) in the Exoplanet Encyclopaedia as of 2012 January 31, 350 are robustly detected by WISE at {>=}5{sigma} level. We perform detailed photosphere subtraction using tools developed for Spitzer data and visually inspect all the WISE images to confirm bona fide point sources. We find nine planet-bearing stars show dust excess emission at 12 and/or 22 {mu}m at {>=}3{sigma} level around young, main-sequence, or evolved giant stars. Overall, our results yield an excess incidence of {approx}2.6% for stars of all evolutionary stages, but {approx}1% for planetary debris disks around main-sequence stars. Besides recovering previously known warm systems, we identify one new excess candidate around the young star UScoCTIO 108.

79 ASTRONOMY AND ASTROPHYSICS↗

Diverging polygon-based modeling (DPBM) of concentrated solar flux distributions

This paper presents an efficient and robust methodology for modeling concentrated solar flux distributions. Compared to ray tracing methods, which provide high accuracy but can be computationally intensive, this approach makes a number of simplifying assumptions in order to reduce complexity by modeling incident and reflected flux as a series of simple geometric diverging polygons, then applying shading and blocking effects. A reduction in processing time (as compared to ray tracing) allows for evaluating and visualizing numerous combinations of engineering and operational variables (easily exceeding 106 unique iterations) to ascertain instantaneous, transient, and annual system performance. The method is demonstrated on a linear Fresnel reflector array and a number of variable iteration examples presented. While some precision is sacrificed for computational speed, flux distributions were compared to ray tracing (SolTrace) and average concentration ratio generally found to agree within ~3%. Furthermore, this method presents a quick and very flexible coarse adjust method for concentrated solar power (CSP) field design, and can be used to both rapidly gain an understanding of system performance as well as to narrow variable constraint windows for follow-on high accuracy system optimization.

14 SOLAR ENERGY↗