Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “in situ testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effects of long duration exposure to simulated space environment on nonmetallic materials properties

Nonmetallic materials specimens from the Viking program were tested in situ invacuo after continuous thermal vacuum exposure from 1971/1972 to the present. Eleven tests were done on appropriate specimens of 30 materials; however, no single material received all the tests. Some specimens also were exposed to 1 or 2.5 MeV electrons at differing fluences before testing. Baseline exposure data is reported for graphite/epoxy specimens that were exposed to vacuum since 1974. These materials were transferred to the thermal vacuum storage facility for future in situ testing and irradiation. Thin G/E specimens were tensile tested after thermal-vacuum cycling exposure. Photomicrographic examinations and SEM analyses were done on the failed specimens.

Peacock, C. L., Jr.↗

In-situ proton radiation testing of 2.4 micron wavelength extended InGaAs photodiodes at dry ice and room temperatures

We have successfully tested 290 µm diameter, 2.4 micron wavelength, Extended InGaAs photodiodes coupled with single mode fiber using 50 MeV Protons at both dry ice temperature (-72 °C) and room temperature (20 °C). The devices were reverse biased at 100 mV during the radiation run and their leakage current was continuously monitored insitu during the exposure. These devices find multiple applications in space for spectroscopy & sensing, inter-satellite optical communication links, rapid Doppler shift LIDAR, as well as inter-planetary and Earth-to-Moon communication links. Several photodiodes were tested using 50 MeV Protons with an average flux level of 2.11 × 10 7 protons/cm 2 /s, for a total fluence of 1.0 × 10 11 protons/cm 2 and total dose of 20 krad (water). Pre- and post-radiation results were also measured for leakage current vs. voltage, responsivity (quantum efficiency), and bandwidth of the Extended InGaAs photodiodes. Finally, all devices were found to be fully functional at normal operating conditions and at both dry ice and room temperature.

2.4 micron wavelength↗

Impact of Drilling Operations on Lunar Volatiles Capture: Thermal Vacuum Tests

In Situ Resource Utilization (ISRU) enables future planetary exploration by using local resources to supply mission consumables. This idea of 'living off the land' has the potential to reduce mission cost and risk. On the moon, water has been identified as a potential resource (for life support or propellant) at the lunar poles, where it exists as ice in the subsurface. However, the depth and content of this resource has yet to be confirmed on the ground; only remote detection data exists. The upcoming Resource Prospector mission (RP) will 'ground-truth' the water using a rover, drill, and the RESOLVE science package. As the 2020 planned mission date nears, component level hardware is being tested in relevant lunar conditions (thermal vacuum). In August 2014 a series of drilling tests were performed using the Honeybee Robotics Lunar Prospecting Drill inside a 'dirty' thermal vacuum chamber at the NASA Glenn Research Center. The drill used a unique auger design to capture and retain the lunar regolith simulant. The goal of these tests was to investigate volatiles (water) loss during drilling and sample transfer to a sample crucible in order to validate this regolith sampling method. Twelve soil samples were captured over the course of two tests at pressures of 10(exp-5) Torr and ambient temperatures between -80C to -20C. Each sample was obtained from a depth of 40 cm to 50 cm within a cryogenically frozen bed of NU-LHT-3M lunar regolith simulant doped with 5 wt% water. Upon acquisition, each sample was transferred and hermetically sealed inside a crucible. The samples were later baked out to determine water wt% and in turn volatile loss by following ASTM standard practices. Of the twelve tests, four sealed properly and lost an average of 30% of their available water during drilling and transfer. The variability in the results correlated well with ambient temperature (lower the temperature lower volatiles loss) and the trend agreed with the sublimation rates for the same temperature. Moisture retention also correlated with quantity of sample: a larger amount of material resulted in less water loss. The drilling process took an average of 10 minutes to capture and transfer each sample. The drilling power was approximately 20 Watt with a Weight on Bit of approximately 30 N. The bit temperature indicated little heat input into formation during the drilling process.

drilling↗

Origin, parameters, and underlying deformation mechanisms of propagating deformation bands in irradiated 316L stainless steel

Lüders-type propagating deformation bands were observed in specimens of irradiated 316L stainless steel samples removed from Spallation Neutron Source target vessels after service. Mechanical testing with digital image correlation (DIC) and in-situ tensile testing with scanning electron microscopy electron backscatter diffraction showed that the observed Lüders-type behavior was not related to the known transformation-induced plasticity or twinning-induced plasticity behavior. Instead, the phenomenon occurs at small local strain values before a significant amount of martensite or deformation twins appear in the microstructure. Microstructural analysis and in-situ mechanical test results suggest Lüders-type band formation and propagation were related to the appearance and evolution of defect-free channels—analogous to slip bands. A modified Swift equation with a Ludwigson-like component was offered to rationalize the phenomenon and model the strain-softening processes at small strain values. Finally, the results indicate complex microstructural processes and deformation mechanisms were active at small strain values and underline the benefits of advanced mechanical test approaches such as DIC.

36 MATERIALS SCIENCE↗

A Cable Condition Monitoring Strategy for Safe and Reliable Plant Operation

Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.

36 MATERIALS SCIENCE↗

Investigating the failure behavior of cast Al-11Ce-0.4Mg alloys using in-situ scanning electron microscopy tensile testing

Within the last decade, research on Al-Ce-Mg alloys has reported promising results for use in cast part applications. In this paper, the failure behavior of cast Al-11Ce-0.4Mg (wt%) was investigated experimentally with focus on the effect the matrix and intermetallic phases have on the fracture propagation behavior at failure. For the first time, in-situ SEM tensile testing was used to study the failure behavior of cast Al-Ce alloys, reporting results for uniaxial, DIC, and single edge notch tensile tests. The results of the in-situ SEM tensile testing were compared with the materials characterization experiments, which included serial sectioning, EBSD, EDS, and fractography. Analysis of EBSD and EDS mapping of cast Al-11Ce-0.4Mg showed that the cast microstructure was a hypereutectic two phase Al-Ce alloy with grains encompassing large complex colonies of laminar eutectic Al 11 Ce 3 intermetallic. The uniaxial tensile results reported the effect casting defects have on the strength and ductility of the alloy, and DIC in-situ testing showed that the eutectic colonies plastically deform less than the matrix phase. In-situ SEM single edge notch tensile testing displayed how the strength of an individual phase affected the crack propagation direction in the alloy. The results of both the materials characterization and in-situ tensile testing experiments on the failure of this alloy revealed further directions for future alloy development that can improve both the strength and fracture toughness of Al-Ce-Mg alloys.

36 MATERIALS SCIENCE↗

Measurement of grain boundary strength of Inconel X-750 superalloy using in-situ micro-tensile testing techniques in FIB/SEM system

Grain boundaries (GBs), known as two-dimensional defects, are omnipresent in polycrystalline metallic alloys and thus influence a wide range of mechanical properties under different environmental conditions like irradiation and corrosion. Therefore, quantifying the strength of individual GBs is critical for understanding the degradation of mechanical properties of materials under different conditions. In this study we developed an efficient approach for the fabrication of micro-tensile specimens with a GB almost perpendicular to the tensile direction, which is expected to advance the development of individual GB tensile testing at micro or nanoscale in a wide scope of materials. Further, an in-situ cantilever micro-tensile testing method was developed and used to quantify the strength of a Σ3 GB in Inconel X-750 with the combination of finite element modeling. The average ultimate tensile strength (UTS) of a non-irradiated Σ3 GB is estimated at around 1.4 GPa, comparable to that of a neutron-irradiated Σ3 GB with a dose of ~1.5 dpa (1.3 GPa). Moreover, the in-situ push-to-pull micro-tensile testing technique developed in this work provides valuable insights into the high-angle GB deformation and fracture behavior. This method generates qualitatively similar ductility behavior before and after neutron irradiation as the bulk material testing. However, the ductility and UTS values obtained from this method are different from bulk measurements due to vastly different specimen dimensions.

36 MATERIALS SCIENCE↗