A Look from the Inside

NASA's Hubble Space Telescope has given the world amazing images of the distant stars, planets, and galaxies. The cutting-edge imaging technology that enhances the Hubble images also extends its benefits to life here on Earth, from deciphering previously unreadable portions of the Dead Sea Scrolls to improving digital mammographies for advanced cancer detection. This imaging technology is now helping physicians to perform micro-invasive arthroscopic surgery, which is the visual examination of an interior joint such as the knee. In 1997, NASA's Glenn Research Center signed a Space Act Agreement with Micro Medical Devices, Inc. (MMD), a medical device engineering company that licenses miniature surgical devices. At that time, MMD was in the process of developing a new micro-endoscope. This tool enables surgeons to view what is happening inside the body on a screen, eliminating the need for a more invasive diagnostic procedure. The images from the micro-endoscope needed to be extremely clear, a challenge with the tool s small size. The images also needed to be viewed in real time to allow surgeons to see what was happening in the body at that very moment. MMD established Clear Image Technology, LLC, of Elyria, Ohio, to commercialize the miniature endoscope. Clear Image Technology then partnered with Arthrotek, Inc., a sports medicine subsidiary of Biomet, Inc., to introduce the tool to the commercial market as the InnerVue[TM] Diagnostic Scope System. The InnerVue system is designed for use in a diagnostic environment, such as an office or outpatient service, to evaluate conditions within a joint. While the InnerVue scope is primarily being applied to the knee and shoulder, other small joints such as the wrist, elbow, and ankle are being investigated. A physician can use the system alone or in conjunction with magnetic resonance imaging (MRI) to determine the next treatment step for each patient. The procedure can be more accurate than MRI, particularly with diagnosing cartilage and articular surface damage and assessing arthritis severity.

Source record

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Artificial intelligence-based predictive modeling for imaging neutral particle analyzers on the DIII-D tokamak

The Imaging Neutral Particle Analyzer (INPA) at DIII-D is a diagnostic system used to accurately resolve the energy and spatial distributions of fast ions in fusion plasmas. A novel artificial intelligence (AI) technique named INPA-net is based on Reservoir Computing Networks and developed here to predict active and passive signals produced by charge-exchange reactions from injected and edge-cold neutrals, respectively, in magnetically confined fusion plasmas. This model is trained using a set of 21 time domain signals between 0 s to 3.35 s that includes injected beam and thermal plasma information, and 6444 real 2D experimental images of the INPA in 12 plasma discharges at DIII-D. The trained neural network is able to forecast experimental images in real-time. The model achieves an R-squared value of 0.91, which is higher than the 0.83 value achieved by a simple linear regression model. This improvement highlights the model's enhanced predictive accuracy for measured images from the validation set. This AI approach is valuable due to its rapid response times and potential for integration into real-time plasma control systems. A version of this model capable of generating syntehic images would be useful for the real-time monitoring of fast-ion transport. A comprehensive sensitivity study reveals that INPA-net maintains high performance even with variations in the input parameters, indicating the model's robustness and reliability. While developed for the INPA, the underlying architecture is adaptable and may be applied to various 2D imaging diagnostics in fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

State-of-Charge Investigation of Lithium Manganese Dioxide Primary Batteries Utilizing X-ray Computed Tomography

Lithium primary batteries (LPBs) represent a class of energy storage devices, uniquely suited for mission-critical applications including emergency backup power, aerospace and defense electronics, implantable medical devices, and remote sensing. Despite their technological maturity and distinct advantages over rechargeable lithium-ion batteries (i.e., superior shelf life and operational simplicity), state-of-charge (SoC) estimation in these batteries remains a persistent challenge due to the lack of a reliable, quantifiable diagnostic technique. In this work, we investigate X-ray computed tomography (X-CT) as a transformative and accurate SoC estimation technique for LPBs. Results gained through X-CT measurements reveal systematic, quantifiable structural changes in cathode morphology and geometry during discharge, establishing a direct structural basis for SoC estimation, with a maximum relative standard deviation of 2.3%. This work establishes a pathway toward operando, imaging-driven SoC diagnostics that can significantly enhance the reliability of SoC estimation in LPBs.

25 ENERGY STORAGE

Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system

An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.

Popp, R. L.

Virtual Guidance Ultrasound: A Tool to Obtain Diagnostic Ultrasound for Remote Environments

Astronauts currently acquire ultrasound images on the International Space Station with the assistance of real-time remote guidance from an ultrasound expert in Mission Control. Remote guidance will not be feasible when significant communication delays exist during exploration missions beyond low-Earth orbit. For example, there may be as much as a 20- minute delay in communications between the Earth and Mars. Virtual-guidance, a pre-recorded audio-visual tutorial viewed in real-time, is a viable modality for minimally trained scanners to obtain diagnostically-adequate images of clinically relevant anatomical structures in an autonomous manner. METHODS: Inexperienced ultrasound operators were recruited to perform carotid artery (n = 10) and ophthalmic (n = 9) ultrasound examinations using virtual guidance as their only instructional tool. In the carotid group, each each untrained operator acquired two-dimensional, pulsed, and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. RESULTS: Eight of the 10 carotid studies were judged to be diagnostically adequate. With one exception the quality of all the ophthalmic images were adequate to excellent. CONCLUSION: Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by untrained operators with instruction only from an audio/video tutorial viewed in real time while scanning. This form of quick-response-guidance, can be developed for other ultrasound examinations, represents an opportunity to acquire important medical and scientific information for NASA flight surgeons and researchers when trained medical personnel are not present. Further, virtual guidance will allow untrained personnel to autonomously obtain important medical information in remote locations on Earth where communication is difficult or absent.

Caine,Timothy L.

Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR

First observations of edge instabilities in strongly shaped negative triangularity plasmas on DIII-D

Throughout the 2023 DIII-D negative triangularity (NT) campaign, unexpected magnetic fluctuations indicative of an edge localized instability were observed in the majority of strongly shaped (–0.55 ≤ δ ≤ –0.45) discharges. Moreover, these same fluctuations were found to be absent in weaker NT plasma shapes. Based on a database study, three separate mode behaviors are observed based primarily on the edge safety factor and normalized plasma beta β N . The main regime is the bursty state, in which short (~5 ms) magnetic bursts occur every 5–10 ms. Each burst drives a small reduction in the edge electron temperature (T e ) as measured by electron cyclotron emissions (ECE), which then rapidly recovers between the bursts. The quiescent regime appears to have governing mechanics similar to the bursty regime, but with multiple unique mode signatures observed in the magnetics. These additional modes greatly reduce the bursty nature of the plasma. Finally, a saturated state is observed in a number of discharges, particularly at early time slices. The saturated regime is often short-lived (maximum 500 ms), but can have a large impact on the dynamics of the plasma edge region, causing significant drops in electron temperature as observed in the ECE diagnostic. 2D ECE imaging (ECE-I) is utilized, showing large kink-like perturbations localized near the last closed flux surface that extend into the SOL indicative of an external kink/peeling behavior. Additionally, evidence of phase mixing and observed tearing-parity perturbations localized near the edge rational surfaces is observed in the quiescent regime plasmas. As a result, the various modes do not appear to have a large impact on global confinement but may play a role in regulating the transport of the NT edge and the observed edge gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Regional-scale estimates of surface moisture availability and thermal inertia using remote thermal measurements

A review is presented of numerical models which were developed to interpret thermal IR data and to identify the governing parameters and surface energy fluxes recorded in the images. Analytic, predictive, diagnostic and empirical models are described. The limitations of each type of modeling approach are explored in terms of the error sources and inherent constraints due to theoretical or measurement limitations. Sample results of regional-scale soil moisture or evaporation patterns derived from the Heat Capacity Mapping Mission and GOES satellite data through application of the predictive model devised by Carlson (1981) are discussed. The analysis indicates that pattern recognition will probably be highest when data are collected over flat, arid, sparsely vegetated terrain. The soil moisture data then obtained may be accurate to within 10-20 percent.

Carlson, T. N.

Soft X-ray astronomy using grazing incidence optics

The instrumental background of X-ray astronomy with an emphasis on high resolution imagery is outlined. Optical and system performance, in terms of resolution, are compared and methods for improving the latter in finite length instruments described. The method of analysis of broadband images to obtain diagnostic information is described and is applied to the analysis of coronal structures.

Davis, John M.

Seismic Holography of Solar Activity

The basic goal of the project was to extend holographic seismic imaging techniques developed under a previous NASA contract, and to incorporate phase diagnostics. Phase-sensitive imaging gives us a powerful probe of local thermal and Doppler perturbations in active region subphotospheres, allowing us to map thermal structure and flows associated with "acoustic moats" and "acoustic glories". These remarkable features were discovered during our work, by applying simple acoustic power holography to active regions. Included in the original project statement was an effort to obtain the first seismic images of active regions on the Sun's far surface.

Lindsey, Charles

Proposed Space Flight Experiment Hardware

The primary thrust for this plan is to develop design tools and fundamental understanding that are timely and consistent with the goal of the various exploration initiatives. The plan will utilize ISS facilities, such as the Fluids Integrated Rack (FIR) and the Microgravity Science Glovebox (MSG). A preliminary flow schematic of Two-Phase Flow Facility (T(phi)FFy) which would utilize FIR is shown in Figure 3. MSG can be utilized to use the Boiling eXperiment Facility (BXF) and Contact Line Dynamics Experiment (CLiDE) Facility. The T(phi)FFy system would have multiple test sections whereby different configurations of heat exchangers could be used to study boiling and condensation phenomena. The test sections would be instrumented for pressure drop, void fraction, heat fluxes, temperatures, high-speed imaging and other diagnostics. Besides a high-speed data acquisition system with a large data storage capability, telemetry could be used to update control and test parameters and download limited amounts of data. In addition, there would be multiple accumulators that could be used to investigate system stability and fluid management issues. The system could accommodate adiabatic tests through either the space station nitrogen supply or have an experiment-specific compressor to pressurize a sufficient amount of air or other non-condensable gas for reuse as the supply bottle is depleted.

Source record

Gravity Effects in Condensing and Evaporating Films

A general overview of gravity effects in condensing and evaporating films is presented. The topics include: 1) Research Overview; 2) NASA Recognizes Critical Need for Condensation & Evaporation Research to Enable Human Exploration of Space; 3) Condensation and Evaporation Research in Reduced Gravity is Enabling for AHST Technology Needs; 4) Differing Role of Surface Tension on Condensing/Evaporating Film Stability; 5) Fluid Mechanisms in Condensing and Evaporating Films in Reduced Gravity; 6) Research Plan; 7) Experimental Configurations for Condensing Films; 8) Laboratory Condensation Test Cell; 9) Aircraft Experiment; 10) Condensation Study Current Test Conditions; 11) Diagnostics; 12) Shadowgraph Images of Condensing n- pentane Film in Unstable (-1g) Configuration; 13) Condensing n-Pentane Film in Normal Gravity (-1g) at Constant Pressure; 14) Condensing n-Pentane Film in Normal Gravity (-1g) with Cyclic Pressure; 15) Non-condensing Pumped Film in Normal Gravity (-1g); 16) Heat Transfer Coefficient in Developing, Unstable Condensing Film in Normal Gravity; 17) Heat Transfer for Unsteady Condensing Film (-1g); 18) Ultrasound Measurement of Film Thickness N-pentane Film, Stable (+1g) Configuration; and 19) Ultrasound Measurement of Film Thickness N-pentane Film, Unstable (-1g) Configuration.

Hermanson, J. C.

Smart Ultrasound Remote Guidance Experiment (SURGE)- Concept of Operations Evaluation for Using Remote Guidance Ultrasound for Planetary Space Flight

Introduction Use of remote guidance (RG) techniques aboard the International Space Station (ISS) has enabled astronauts to collect diagnostic-level ultrasound images. Exploration class missions will require this cohort of (typically) non-formally trained sonographers to operate with greater autonomy given the longer communication delays (2 seconds for ISS vs. >6 seconds for missions beyond the Moon) and communication blackouts. To determine the feasibility and training requirements for autonomous ultrasound image collection by non-expert ultrasound operators, ultrasound images were collected from a similar cohort using three different image collection protocols: RG only, RG with a computer-based learning tool (LT), and autonomous image collection with LT. The groups were assessed for both image quality and time to collect the images. Methods Subjects were randomized into three groups: RG only, RG with LT, and autonomous with LT. Each subject received 10 minutes of standardized training before the experiment. The subjects were tasked with making the following ultrasound assessments: 1) bone fracture and 2) focused assessment with sonography in trauma (FAST) to assess a patient s abdomen. Human factors-related questionnaire data were collected immediately after the assessments. Results The autonomous group did not out-perform the two groups that received RG. The mean time for the autonomous group to collect images was less than the RG groups, however the mean image quality for the autonomous group was less compared to both RG groups. Discussion Remote guidance continues to produce higher quality ultrasound images than autonomous ultrasound operation. This is likely due to near-instant feedback on image quality from the remote guider. Expansion in communication time delays, however, diminishes the capability to provide this feedback, thus requiring more autonomous ultrasound operation. The LT has the potential to be an excellent training and coaching component for autonomous ultrasound image collection during exploration missions.

Hurst, Victor, IV

Subscale Test Program for the Orion Conical Ribbon Drogue Parachute

A subscale wind tunnel test program for Orion's conical ribbon drogue parachute is under development. The desired goals of the program are to quantify aerodynamic performance of the parachute in the wake of the entry vehicle, including understanding of the coupling of the parachute and command module dynamics, and an improved understanding of the load distribution within the textile elements of the parachute. The test program is ten percent of full scale conducted in a 3x2.1 m (10x7 ft) closed loop subsonic wind tunnel. The subscale test program is uniquely suited to probing the aerodynamic and structural environment in both a quantitative and qualitative manner. Non-intrusive diagnostics, including Particle Image Velocimetry for wake velocity surveys, high speed pressure transducers for canopy pressure distribution, and a high speed photogrammetric reconstruction, will be used to quantify the parachute's performance.

parachute

Rock-type discrimination from ratioed infrared scanner images of Pisgah Crater, California.

The radiances in two thermal infrared channels of an airborne scanner system were ratioed to produce images that recorded compositionally diagnostic emittance variations for several silicate rock types near Pisgah Crater, California. The images demonstrate that the ratio method is capable of enhancing emittance variations in the presence of temperature extremes that differ by no more than 25 C, with no temperature corrections.

Vincent, R. K.

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY

Diagnostic and quality-assurance tools for low-contrast images obtained from array detectors

We investigate methods of estimating a background image frame for subtraction from a data frame for use when a more suitable measured background frame is not available. We define background as any signal component that is not attributable to the phenomenon currently under investigation. We describe a technique that is based on pixel-by-pixel least-squares regression of images for computing a background frame from available data. We argue that the same technique can be a useful quality-assurance tool for evaluating instrument performance. For example, it can help to separate image structure resulting from the reading process from structure resulting from the characteristics of the detector itself. We demonstrate that background estimation can be nontrivial by comparing the results of different background estimation procedures by using data obtained from a CCD array detector. We investigate the temperature-dependent contributions of the detector and readout electronics to the total signal as a demonstration of the diagnostic capabilities of least-squares image regression.