Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Exact reconstruction analysis/synthesis filter banks with time-varying filters

This paper examines some of the analysis/synthesis issues associated with FIR time-varying filter banks where the filter bank coefficients are allowed to change in response to the input signal. Several issues are identified as being important in order to realize performance gains from time-varying filter banks in image coding applications. These issues relate to the behavior of the filters as transition from one set of filter banks to another occurs. Lattice structure formulations for the time varying filter bank problem are introduced and discussed in terms of their properties and transition characteristics.

Arrowood, J. L., Jr.↗

Flight software issues in onboard automated planning: lessons learned on EO-1

This paper focuses on the onboard planner and scheduler CASPER, whose core planning engine is based on the ground system ASPEN. Given the challenges of developing flight software, we discuss several of the issues encountered in preparing the planner for flight, including reducing the code image size, determining what data to place within the engineering telemetry packet, and performing long term planning.

planning↗

NASA Tech Briefs, March 2011

Topics covered include: Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation; Airborne Radar Interferometric Repeat-Pass Processing; Plug-and-Play Environmental Monitoring Spacecraft Subsystem; Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz; Wallops Ship Surveillance System; Source Lines Counter (SLiC) Version 4.0; Guidance, Navigation, and Control Program; Single-Frame Terrain Mapping Software for Robotic Vehicles; Auto Draw from Excel Input Files; Observation Scheduling System; CFDP for Interplanetary Overlay Network; X-Windows Widget for Image Display; Binary-Signal Recovery; Volumetric 3D Display System with Static Screen; MMIC Replacement for Gunn Diode Oscillators; Feature Acquisition with Imbalanced Training Data; Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads; Carbon Nanotube-Based Structural Health Monitoring Sensors; Wireless Inductive Power Device Suppresses Blade Vibrations; Safe, Advanced, Adaptable Isolation System Eliminates the Need for Critical Lifts; Anti-Rotation Device Releasable by Insertion of a Tool; A Magnetically Coupled Cryogenic Pump; Single Piezo-Actuator Rotary-Hammering Drill; Fire-Retardant Polymeric Additives; Catalytic Generation of Lift Gases for Balloons; Ionic Liquids to Replace Hydrazine; Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings; Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger; Multi-Mission Power Analysis Tool; Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications; Gravitational Wave Detection with Single-Laser Atom Interferometers; Titanium Alloy Strong Back for IXO Mirror Segments; Improved Ambient Pressure Pyroelectric Ion Source; Multi-Modal Image Registration and Matching for Localization of a Balloon on Titan; Entanglement in Quantum-Classical Hybrid; Algorithm for Autonomous Landing; Quantum-Classical Hybrid for Information Processing; Small-Scale Dissipation in Binary-Species Transitional Mixing Layers; Superpixel-Augmented Endmember Detection for Hyperspectral Images; Coding for Parallel Links to Maximize the Expected Value of Decodable Messages; and Microwave Tissue Soldering for Immediate Wound Closure.

Source record↗

4D Light Field Imaging System Using Programmable Aperture

Complete depth information can be extracted from analyzing all angles of light rays emanated from a source. However, this angular information is lost in a typical 2D imaging system. In order to record this information, a standard stereo imaging system uses two cameras to obtain information from two view angles. Sometimes, more cameras are used to obtain information from more angles. However, a 4D light field imaging technique can achieve this multiple-camera effect through a single-lens camera. Two methods are available for this: one using a microlens array, and the other using a moving aperture. The moving-aperture method can obtain more complete stereo information. The existing literature suggests a modified liquid crystal panel [LC (liquid crystal) panel, similar to ones commonly used in the display industry] to achieve a moving aperture. However, LC panels cannot withstand harsh environments and are not qualified for spaceflight. In this regard, different hardware is proposed for the moving aperture. A digital micromirror device (DMD) will replace the liquid crystal. This will be qualified for harsh environments for the 4D light field imaging. This will enable an imager to record near-complete stereo information. The approach to building a proof-ofconcept is using existing, or slightly modified, off-the-shelf components. An SLR (single-lens reflex) lens system, which typically has a large aperture for fast imaging, will be modified. The lens system will be arranged so that DMD can be integrated. The shape of aperture will be programmed for single-viewpoint imaging, multiple-viewpoint imaging, and coded aperture imaging. The novelty lies in using a DMD instead of a LC panel to move the apertures for 4D light field imaging. The DMD uses reflecting mirrors, so any light transmission lost (which would be expected from the LC panel) will be minimal. Also, the MEMS-based DMD can withstand higher temperature and pressure fluctuation than a LC panel can. Robotics need near complete stereo images for their autonomous navigation, manipulation, and depth approximation. The imaging system can provide visual feedback

Bae, Youngsam↗

New Mission Concept: Investigation of the Galactic Center with the Galactic Center Explorer (GalCenEx)

The European Space Observatory INTEGRAL has been providing excellent results on X-ray and γ–ray astronomy since its launch in 2002. Among the most important results are the spectroscopy and imaging measurements of celestial γ-ray sources, including mapping the 511 keV radiation from the Galactic plane. However, the nature of the 511 keV positron annihilation line around the Galactic Center region is still a mystery. Similarly, the structure and nature of the Galactic Center supermassive black hole and its surroundings, as well as the structure of heavily populated sky regions such as Cygnus and Carina in γ-rays, remain unclear. We present a concept of a potential next-generation γ-ray telescope with the major science objectives: a) solve the mystery of the Galactic Center region 511 keV positron annihilation line by mapping the Galactic Center region with high energy (<1% FWHM) and angular (< 10 arcmin) resolution and with line sensitivity <10-5 ph cm-2 s-1; b) understand the nature of the Galactic Center supermassive black hole environment by creating a high-resolution spectral and intensity map of the surrounding region in 0.1 – 20 MeV γ rays; and c) explore Galactic chemical evolution and sites of explosive element synthesis by conducting high-sensitivity measurements of nuclear lines from Type 1a supernovae and other objects. The instrument is based on a novel high energy and position resolution CdZnTe Imager, coded aperture mask, and heavy-scintillator shield, and can be considered for a NASA Explorer mission.

Moiseev, Alexander↗

Hard X-ray imaging from Explorer

Coded aperture X-ray detectors were applied to obtain large increases in sensitivity as well as angular resolution. A hard X-ray coded aperture detector concept is described which enables very high sensitivity studies persistent hard X-ray sources and gamma ray bursts. Coded aperture imaging is employed so that approx. 2 min source locations can be derived within a 3 deg field of view. Gamma bursts were located initially to within approx. 2 deg and X-ray/hard X-ray spectra and timing, as well as precise locations, derived for possible burst afterglow emission. It is suggested that hard X-ray imaging should be conducted from an Explorer mission where long exposure times are possible.

Grindlay, J. E.↗

Coding for Efficient Image Transmission

NASA publication second in series on data-coding techniques for noiseless channels. Techniques used even in noisy channels, provided data further processed with Reed-Solomon or other error-correcting code. Techniques discussed in context of transmission of monochrome imagery from Voyager II spacecraft but applicable to other streams of data. Objective of this type coding to "compress" data; that is, to transmit using as few bits as possible by omitting as much as possible of portion of information repeated in subsequent samples (or picture elements).

Rice, R. F.↗

Gamma ray Imaging Based Methods to Improve the Accuracy of Uranium Holdup Quantification

Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hard x ray imaging graphics development and literature search

This report presents work performed between June 1990 and June 1991 and has the following objectives: (1) a comprehensive literature search of imaging technology and coded aperture imaging as well as relevant topics relating to solar flares; (2) an analysis of random number generators; and (3) programming simulation models of hard x ray telescopes. All programs are compatible with NASA/MSFC Space Science LAboratory VAX Cluster and are written in VAX FORTRAN and VAX IDL (Interactive Data Language).

Emslie, A. Gordon↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Skylab S-192 ratio codes of soil, mineral, and rock spectra for ratio image selection and interpretation

A limited theoretical systems study is made of the Skylab S-192 12-channel multispectral scanner's capabilities for geological remote sensing. Laboratory spectra of rocks, minerals, soils, and some vegetation were used to rank the twelve channels and the best twelve of the 66 possible nonreciprocal spectral ratios according to their ability to discriminate among 17 classes of geological targets. Environmental and instrumental noise sources were ignored. The S-192 should be most useful for discriminating minerals deposited by hydrothermal alteration, weathering, and evaporation. Discrimination of igneous rocks will be difficult. Ratio images are recommended over automatic discrimination methods for those geological targets that can be enhanced by ratio imaging. Ratio codes were found for the twelve highest ranked ratios, for use in selecting the ratio images which will best enhance a target of interest. They can also be searched for false alarm candidates for a given target.

Vincent, R. K.↗

Improved image decompression for reduced transform coding artifacts

The perceived quality of images reconstructed from low bit rate compression is severely degraded by the appearance of transform coding artifacts. This paper proposes a method for producing higher quality reconstructed images based on a stochastic model for the image data. Quantization (scalar or vector) partitions the transform coefficient space and maps all points in a partition cell to a representative reconstruction point, usually taken as the centroid of the cell. The proposed image estimation technique selects the reconstruction point within the quantization partition cell which results in a reconstructed image which best fits a non-Gaussian Markov random field (MRF) image model. This approach results in a convex constrained optimization problem which can be solved iteratively. At each iteration, the gradient projection method is used to update the estimate based on the image model. In the transform domain, the resulting coefficient reconstruction points are projected to the particular quantization partition cells defined by the compressed image. Experimental results will be shown for images compressed using scalar quantization of block DCT and using vector quantization of subband wavelet transform. The proposed image decompression provides a reconstructed image with reduced visibility of transform coding artifacts and superior perceived quality.

Orourke, Thomas P.↗

Visual communication - Information and fidelity

This assessment of visual communication deals with image gathering, coding, and restoration as a whole rather than as separate and independent tasks. The approach focuses on two mathematical criteria, information and fidelity, and on their relationships to the entropy of the encoded data and to the visual quality of the restored image. Past applications of these criteria to the assessment of image coding and restoration have been limited to the link that connects the output of the image-gathering device to the input of the image-display device. By contrast, the approach presented in this paper explicitly includes the critical limiting factors that constrain image gathering and display. This extension leads to an end-to-end assessment theory of visual communication that combines optical design with digital processing.

Huck, Freidrich O.↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Low bit rate coding of Earth science images

In this paper, the authors discuss compression based on some new ideas in vector quantization and their incorporation in a sub-band coding framework. Several variations are considered, which collectively address many of the individual compression needs within the earth science community. The approach taken in this work is based on some recent advances in the area of variable rate residual vector quantization (RVQ). This new RVQ method is considered separately and in conjunction with sub-band image decomposition. Very good results are achieved in coding a variety of earth science images. The last section of the paper provides some comparisons that illustrate the improvement in performance attributable to this approach relative the the JPEG coding standard.

Kossentini, Faouzi↗