Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Fully Automated Method for CT-on-Rails-Guided Online Adaptive Planning for Prostate Cancer Intensity Modulated Radiation Therapy

Purpose: This study was designed to validate a fully automated adaptive planning (AAP) method which integrates automated recontouring and automated replanning to account for interfractional anatomical changes in prostate cancer patients receiving adaptive intensity modulated radiation therapy (IMRT) based on daily repeated computed tomography (CT)-on-rails images. Methods and Materials: Nine prostate cancer patients treated at our institution were randomly selected. For the AAP method, contours on each repeat CT image were automatically generated by mapping the contours from the simulation CT image using deformable image registration. An in-house automated planning tool incorporated into the Pinnacle treatment planning system was used to generate the original and the adapted IMRT plans. The cumulative dose–volume histograms (DVHs) of the target and critical structures were calculated based on the manual contours for all plans and compared with those of plans generated by the conventional method, that is, shifting the isocenters by aligning the images based on the center of the volume (COV) of prostate (prostate COV-aligned). Results: The target coverage from our AAP method for every patient was acceptable, while 1 of the 9 patients showed target underdosing from prostate COV-aligned plans. The normalized volume receiving at least 70 Gy (V{sub 70}), and the mean dose of the rectum and bladder were reduced by 8.9%, 6.4 Gy and 4.3%, 5.3 Gy, respectively, for the AAP method compared with the values obtained from prostate COV-aligned plans. Conclusions: The AAP method, which is fully automated, is effective for online replanning to compensate for target dose deficits and critical organ overdosing caused by interfractional anatomical changes in prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-31: Monitor Interfractional Variation of Tumor Respiratory Motion Using 4D KV Conebeam Computed Tomography for Stereotactic Body Radiation Therapy of Lung Cancer

Purpose: 4DCT has been widely used to generate internal tumor volume (ITV) for a lung tumor for treatment planning. However, lung tumors may show different respiratory motion on the treatment day. The purpose of this study is to evaluate 4D KV conebeam computed tomography (CBCT) for monitoring tumor interfractional motion variation between simulation and each fraction of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: 4D KV CBCT was acquired with the Elekta XVI system. The accuracy of 4D KV CBCT for image-guided radiation therapy (IGRT) was tested with a dynamic thorax motion phantom (CIRS, Virginia) with a linear amplitude of 2 cm. In addition, an adult anthropomorphic phantom (Alderson, Rando) with optically stimulated luminescence (OSL) dosimeters embedded at the center and periphery of a slab of solid water was used to measure the dose of 4D KV CBCT and to compare it with the dose with 3D KV CBCT. The image registration was performed by aligning\ each phase images of 4D KV CBCT to the planning images and the final couch shifts were calculated as a mean of all these individual shifts along each direction.A workflow was established based on these quality assurance tests for lung cancer patients. Results: 4D KV CBCT does not increase imaging dose in comparison to 3D KV CBCT. Acquisition of 4D KV CBCT is 4 minutes as compared to 2 minutes for 3D KV CBCT. Most of patients showed a small daily variation of tumor respiratory motion about 2 mm. However, some patients may have more than 5 mm variations of tumor respiratory motion. Conclusion: The radiation dose does not increase with 4D KV CBCT. 4D KV CBCT is a useful tool for monitoring interfractional variations of tumor respiratory motion before SBRT of lung cancer patients.

60 APPLIED LIFE SCIENCES↗

X-ray observations of sunspot penumbral structure

High-resolution coronal observations with the Normal Incidence X-ray Telescope (NIXT) reveal previously unobserved structure in the magnetic fields above a sunspot. The X-ray images are precisely aligned with a continuum photospheric image taken at the same time. The X-ray brightness traces magnetic field lines and shows: (1) that none of the bright loops originate in the spot umbra and (2) that some field lines emerging from the inner penumbra connect to regions far away from the spot. Such large-scale structures must remain distinct from the shallowly inclined fields in the outer penumbra. In particular, they cannot be involved in any interchange between the bright and dark filaments. This imposes constraints on models of penumbral convection.

Sams, B. J., III↗

Image Mapping and Visual Attention on the Sensory Ego-Sphere

The Sensory Ego-Sphere (SES) is a short-term memory for a robot in the form of an egocentric, tessellated, spherical, sensory-motor map of the robot s locale. Visual attention enables fast alignment of overlapping images without warping or position optimization, since an attentional point (AP) on the composite typically corresponds to one on each of the collocated regions in the images. Such alignment speeds analysis of the multiple images of the area. Compositing and attention were performed two ways and compared: (1) APs were computed directly on the composite and not on the full-resolution images until the time of retrieval; and (2) the attentional operator was applied to all incoming imagery. It was found that although the second method was slower, it produced consistent and, thereby, more useful APs. The SES is an integral part of a control system that will enable a robot to learn new behaviors based on its previous experiences, and that will enable it to recombine its known behaviors in such a way as to solve related, but novel, task problems with apparent creativity. The approach is to combine sensory-motor data association and dimensionality reduction to learn navigation and manipulation tasks as sequences of basic behaviors that can be implemented with a small set of closed-loop controllers. Over time, the aggregate of behaviors and their transition probabilities form a stochastic network. Then given a task, the robot finds a path in the network that leads from its current state to the goal. The SES provides a short-term memory for the cognitive functions of the robot, association of sensory and motor data via spatio-temporal coincidence, direction of the attention of the robot, navigation through spatial localization with respect to known or discovered landmarks, and structured data sharing between the robot and human team members, the individuals in multi-robot teams, or with a C3 center.

Fleming, Katherine Achim↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

Towards Automated Transcription of Label Text from Pinned Insect Collections

We present a computer vision system that can transcribe the text on tiny printed labels stacked beneath pinned insects (as found in museum collections). The approach uses multiple views of each label because the labels are often occluded by the pin, the insect specimen, and other labels. Our approach handles occlusion and the extreme viewing angles required to image the stacked labels. Automated image analysis identifies the lines of text and then aligns and rectifies the images. Combining the aligned and rectified images from multiple viewpoints enables us to create a composite image that can be read using optical character recognition tools (OCR) to extract the text. We provide experimental demonstration using both museum specimens and experimental test labels

Agarwal, Nitin↗

The persistent shadow of the supermassive black hole of M87. II. Model comparisons and theoretical interpretations

The Event Horizon Telescope (EHT) observation of M87∗ in 2018 has revealed a ring with a diameter that is consistent with the 2017 observation. The brightest part of the ring is shifted to the southwest from the southeast. In this paper, we provide theoretical interpretations for the multi-epoch EHT observations for M87∗ by comparing a new general relativistic magnetohydrodynamics model image library with the EHT observations for M87∗ in both 2017 and 2018. The model images include aligned and tilted accretion with parameterized thermal and nonthermal synchrotron emission properties. The 2018 observation again shows that the spin vector of the M87∗ supermassive black hole is pointed away from Earth. A shift of the brightest part of the ring during the multi-epoch observations can naturally be explained by the turbulent nature of black hole accretion, which is supported by the fact that the more turbulent retrograde models can explain the multi-epoch observations better than the prograde models. The EHT data are inconsistent with the tilted models in our model image library. Assuming that the black hole spin axis and its large-scale jet direction are roughly aligned, we expect the brightest part of the ring to be most commonly observed 90 deg clockwise from the forward jet. This prediction can be statistically tested through future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiperspective Automotive Labeling

Supervised machine learning techniques inherently rely on datasets to be trained. With image datasets traditionally being annotated by humans, many advancements in image annotation tools have been made to ensure creation of rich datasets with accurate labels. Nevertheless, users still find it challenging to create and use their own datasets with labels that reflect their problem domain. We propose a streamlined labeling process that aligns multiperspective images and allows a transition from a labeled perspective to other perspectives. The main goal of this work is to reduce the human effort required for labeling vehicle images under favorable conditions where the image perspectives are correlated and one or more perspectives are known. A case study is described and analyzed to show the effectiveness of the process, as well as constraints and limitations when applied to other cases.

training dataset, multiperspective images, supervi↗

Polarization Imaging Apparatus

A polarization imaging apparatus has shown promise as a prototype of instruments for medical imaging with contrast greater than that achievable by use of non-polarized light. The underlying principles of design and operation are derived from observations that light interacts with tissue ultrastructures that affect reflectance, scattering, absorption, and polarization of light. The apparatus utilizes high-speed electro-optical components for generating light properties and acquiring polarization images through aligned polarizers. These components include phase retarders made of OptoCeramic (registered TradeMark) material - a ceramic that has a high electro-optical coefficient. The apparatus includes a computer running a program that implements a novel algorithm for controlling the phase retarders, capturing image data, and computing the Stokes polarization images. Potential applications include imaging of superficial cancers and other skin lesions, early detection of diseased cells, and microscopic analysis of tissues. The high imaging speed of this apparatus could be beneficial for observing live cells or tissues, and could enable rapid identification of moving targets in astronomy and national defense. The apparatus could also be used as an analysis tool in material research and industrial processing.

Zou, Yingyin K.↗

SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

60 APPLIED LIFE SCIENCES↗

Reconstruction of two-dimensional molecular structure with laser-induced electron diffraction from laser-aligned polyatomic molecules

Imaging the transient process of molecules has been a basic way to investigate photochemical reactions and dynamics. Based on laser-induced electron diffraction and partial one-dimensional molecular alignment, here we provide two effective methods for reconstructing two-dimensional structure of polyatomic molecules. We demonstrate that electron diffraction images in both scattering angles and broadband energy can be utilized to retrieve complementary structure information, including positions of light atoms. Lastly, with picometre spatial resolution and the inherent femtosecond temporal resolution of lasers, laser-induced electron diffraction method offers significant opportunities for probing atomic motion in a large molecule in a typical pump-probe measurement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Directional emittance surface measurement system and process

Apparatus and process for measuring the variation of directional emittance of surfaces at various temperatures using a radiometric infrared imaging system. A surface test sample is coated onto a copper target plate provided with selective heating within the desired incremental temperature range to be tested and positioned onto a precision rotator to present selected inclination angles of the sample relative to the fixed positioned and optically aligned infrared imager. A thermal insulator holder maintains the target plate on the precision rotator. A screen display of the temperature obtained by the infrared imager, and inclination readings are provided with computer calculations of directional emittance being performed automatically according to equations provided to convert selected incremental target temperatures and inclination angles to relative target directional emittance values. The directional emittance of flat black lacquer and an epoxy resin measurements obtained are in agreement with the predictions of the electromagnetic theory and with directional emittance data inferred from directional reflectance measurements made on a spectrophotometer.

Puram, Chith K.↗

Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device

Objective: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. Methods: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54-82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. Results: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. Conclusions: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

SU-E-T-282: Dose Measurements with An End-To-End Audit Phantom for Stereotactic Radiotherapy

Purpose: Report on dose measurements as part of an end-to-end test for stereotactic radiotherapy, using a new audit tool, which allows audits to be performed efficiently either by an onsite team or as a postal audit. Methods: Film measurements have been performed with a new Stereotactic Cube Phantom. The phantom has been designed to perform Winston Lutz type position verification measurements and dose measurements in one setup. It comprises a plastic cube with a high density ball in its centre (used for MV imaging with film or EPID) and low density markers in the periphery (used for Cone Beam Computed Tomography, CBCT imaging). It also features strategically placed gold markers near the posterior and right surfaces, which can be used to calculate phantom rotations on MV images. Slit-like openings allow insertion of film or other detectors.The phantom was scanned and small field treatment plans were created. The fields do not traverse any inhomogeneities of the phantom on their paths to the measurement location. The phantom was setup at the delivery system using CBCT imaging. The calculated treatment fields were delivered, each with a piece of radiochromic film (EBT3) placed in the anterior film holder of the phantom. MU had been selected in planning to achieve similar exposures on all films. Calibration films were exposed in solid water for dose levels around the expected doses. Films were scanned and analysed following established procedures. Results: Setup of the cube showed excellent suitability for CBCT 3D alignment. MV imaging with EPID allowed for clear identification of all markers. Film based dose measurements showed good agreement for MLC created fields down to 0.5 mm × 0.5 mm. Conclusion: An end-to-end audit phantom for stereotactic radiotherapy has been developed and tested.

60 APPLIED LIFE SCIENCES↗

Image defects from surface and alignment errors in grazing incidence telescopes

The rigid body motions and low frequency surface errors of grazing incidence Wolter telescopes are studied. The analysis is based on surface error descriptors proposed by Paul Glenn. In his analysis, the alignment and surface errors are expressed in terms of Legendre-Fourier polynomials. Individual terms in the expression correspond to rigid body motions (decenter and tilt) and low spatial frequency surface errors of mirrors. With the help of the Legendre-Fourier polynomials and the geometry of grazing incidence telescopes, exact and approximated first order equations are derived in this paper for the components of the ray intercepts at the image plane. These equations are then used to calculate the sensitivities of Wolter type I and II telescopes for the rigid body motions and surface deformations. The rms spot diameters calculated from this theory and OSAC ray tracing code agree very well. This theory also provides a tool to predict how rigid body motions and surface errors of the mirrors compensate each other.

Saha, Timo T.↗

Alignment and Characterization of High Uniformity Imaging Spectrometers

Imaging spectrometers require precise adjustments, in some cases at the sub-micrometer level, in order to achieve auniform response over both the spectral and spatial dimensions. We describe a set of measurement techniques and theircorresponding alignment adjustments to achieve the 95% or higher uniformity specifications required for Earthobservingimaging spectrometers. The methods are illustrated with measurements from the Next Generation Imaging Spectrometer system that has been built at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration.

Offner spectrometer↗

SU-E-T-450: How Important Is a Reproducible Breath Hold for DIBH Breast Radiotherapy?

Purpose: Deep inspiration breath hold (DIBH) for left-sided breast cancer has been shown to reduce heart dose. Surface imaging helps to ensure accurate breast positioning, but does not guarantee a reproducible breath hold (BH) at DIBH treatments. We examine the effects of variable BH positions for DIBH treatments. Methods: Twenty-Five patients with free breathing (FB) and DIBH scans were reviewed. Four plans were created for each patient: 1) FB, 2) DIBH, 3) FB-DIBH – the DIBH plans were copied to the FB images and recalculated (image registration was based on breast tissue), and 4) P-DIBH – a partial BH with the heart shifted midway between the FB and DIBH positions. The FB-DIBH plans give “worst case” scenarios for surface imaging DIBH, where the breast is aligned by surface imaging but the patient is not holding their breath. Students t-tests were used to compare dose metrics. Results: The DIBH plans gave lower heart dose and comparable breast coverage versus FB in all cases. The FB-DIBH plans showed no significant difference versus FB plans for breast coverage, mean heart dose, or maximum heart dose (p >= 0.10). The mean heart dose differed between FB-DIBH and FB by < 2 Gy for all cases, the maximum heart dose differed by < 2 Gy for 21 cases. The P-DIBH plans showed significantly lower mean heart dose than FB (p = 0.01). The mean heart doses for the P-DIBH plans were < FB for 22 cases, the maximum dose < FB for 18 cases. Conclusions: A DIBH plan delivered to a FB patient set-up with surface imaging will yield similar dosimetry to a plan created and delivered FB. A DIBH plan delivered with even a partial BH can give reduced heart dose compared to FB techniques when the breast tissue is well aligned.

60 APPLIED LIFE SCIENCES↗