Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “homes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The navigation of homing pigeons: Do they use sun Navigation?

Experiments to determine the dependence of homing pigeons on the sun as a navigational cue are discussed. Various methods were employed to interrupt the circadian rhythms of the pigeons prior to release. It was determined that the sun may serve as a compass, but that topographic features are more important for navigation. The effects of a magnetic field produced by electric equipment carried by the bird were also investigated. It was concluded that magnetic fields may have a small effect on the homing ability. The exact nature of the homing pigeon's navigational ability is still unknown after years of elaborate experimentation.

Walcott, C.↗

Home Page: The Mode of Transport through the Information Superhighway

The purpose of the project with the Aeroacoustics Branch was to create and submit a home page for the internet about branch information. In order to do this, one must also become familiar with the way that the internet operates. Learning HyperText Markup Language (HTML), and the ability to create a document using this language was the final objective in order to place a home page on the internet (World Wide Web). A manual of instructions regarding maintenance of the home page, and how to keep it up to date was also necessary in order to provide branch members with the opportunity to make any pertinent changes.

Lujan, Michelle R.↗

A Simplified View of the Geochemical Diversity Surrounding Home Plate

The Home Plate feature (Fig. 1) within the Inner Basin of the Columbia Hills consists of layered rocks and has been interpreted as an accumulation of pyroclastic deposits [1]. Samples analyzed by the Alpha Particle X-ray Spectrometer within ~25 meters of the eastern margin of Home Plate exhibit a strikingly diverse range of geochemical compositions, including the highest levels of Mg, Si, K, Zn, and Ni measured at Gusev Crater. This wide range of chemical variability across the 40+ samples analyzed on and near Home Plate can be represented by contributions from only six primary components. This reconstruction is not reflected in the M ssbauer mineralogy suggesting that significant alteration of the contributing components has occurred.

Yen, A. S.↗

Measured Moisture Performance of Sealed and Insulated Attics with Permeable Insulation In California Homes

This study performed detailed thermal and moisture measurements in two homes in Fresno and Clovis, California with sealed attics insulated with glass fiber insulation to determine moisture performance in inland California climates. Data were recorded once every minute for more than a year in each home to allow detailed observation of time-varying moisture and thermal conditions. Moisture measurements were taken at multiple locations in each attic and included wood moisture, surface condensation and surface relative humidity. The results showed that there are strong solar-driven diurnal cycles in attic wood and air moisture content, as well as longer-term seasonal and annual variations. Mold growth was obdserved on the North roof deck in one of the two homes even in this sunny dry climate with attics built in compliance with California building codes that specifically address sealed and insulated attics with vapor-permeable insulation. We investigated moisture stratification in the attic and found that, although there is stratification during sunny daytime hours, this was not when wood moisture content, surface humidity or surface condensation are high. Therefore, other moisture transport mechanisms are acting to increase moisture levels near the roof peak. Finally, our measurements also showed that the attic with the highest measured moisture levels did not have any mold growth, while mold was visually observed in the attic whose measurements indicted little or no concern, indicating that the state-of-the-art in moisture measurement and mold growth prediction in building assemblies may be insufficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Home Decarbonization Using Advanced Micro-CHP

An efficient micro-combined heat and power (CHP) prototype was developed to provide heat and electricity for single-family homes and light commercial buildings. The unit can be installed independently at the point of energy consumption. Consequently, it enables cost-effectively and flexibly matching heat and electrical loads, simplifying distribution and installation processes, and recovering and storing waste heat as hot water. The analyzed results show that the micro-CHP using natural gas as fuel achieves 10.68%–32.80% CO2 reduction in the selected five home applications. The potential effect of H2 on decarbonization of these home was also evaluated, finding that the micro-CHP using a blended fuel with H2 and natural gas can further reduce CO2 emissions. However, the 50% CO2 reduction in the micro-CHP requires at least 70%–90% of H2 in the blend with natural gas. Overall, the micro-CHP technology demonstrates a solid potential to accelerate micro-CHP adoption in residential and light commercial markets, thereby promoting broader micro-CHP acceptance and use in the future for building decarbonization.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Residential Buildings: How Smart are Today’s Smart Homes?

Recent years have seen a dramatic increase in the number of “smart” devices available for residential buildings. This column describes opportunities presented by advances in smart home technology that could impact our homes and how we interact with them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Home Energy Assessments

Learn why a home energy assessment is the essential first step to lowering your energy bills. This fact sheet from Energy Saver includes information on why to have a home energy assessment, tips for conducting a do-it-yourself (DIY) energy assessment, and considerations for a professional energy assessment.

home energy assessment, home energy audit, DIY, ai↗

Of impacts, agents, and functions: An interdisciplinary meta-review of smart home energy management systems research

Smart home energy management technologies (SHEMS) have long been viewed as a promising opportunity to manage the way households use energy. Research on this topic has emerged across a variety of disciplines, focusing on different pieces of the SHEMS puzzle without offering a holistic vision of how these technologies and their users will influence home energy use moving forward. This paper presents the results of a systematic, interdisciplinary meta-review of SHEMS literature, assessing the extent to which it discusses the role of various SHEMS components in driving energy benefits. Results reveal a bias towards technical perspectives and controls approaches that seek to drive energy impacts such as load management and energy savings through SHEMS without user or third-party participation. Not only are techno-centric approaches more common, there is also a lack of integration of these approaches with user-centric, information-based solutions for driving energy impacts. Finally, these results suggest future work should investigate more holistic solutions for optimal impacts on household energy use. We hope these results will provoke a broader discussion about how to advance research on SHEMS to capitalize on their potential contributions to demand-side management initiatives moving forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lab Homes

This dataset includes processed data from the Lab Homes (LH) Test Facility located on the PNNL campus in Richland, WA. This a set of 2 identical homes that allow for the side-by-side comparison/performance evaluation of different technologies under the same weather at any given time. The dataset spans December 6, 2021 to December 27, 2021 and represents a series of tests performed; calibration, set-point excitation, pre-heating, free-floating and warm up. The measurements correspond to whole building electrical power, HVAC energy use, water heating, appliances and lighting, as well as space temperatures, space humidity, window glass surface temperatures, through glass solar radiation, and meterological data from an onsite meteorological weather station. In addition to the measurements, a metadata .json file, a .ttl file to visualize the data as per BRICK schema, and a detailed .pdf description of the dataset are also provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ecobee Donate Your Data 1,000 homes in 2017

This dataset is a subset of the Ecobee Donate Your Data (DYD) dataset. The Ecobee DYD data comprises user-reported metadata (of home and occupant characteristics), and data collected by Ecobee thermostats (reported in 5-minute intervals). Participant data are pulled from the Ecobee servers, and then anonymized to remove any personally identifiable information. This subset selects 1,000 single family homes in four states - California, Texas, New York, and Illinois, and span the entire year of 2017. In addition to the measurements, a metadata JSON file is included to illustrate the high-level contextual information of the dataset. The dataset can be analyzed to understand how a single-family heating, ventilation, and air-conditioning (HVAC) system operates, occupant behavior, and building thermal dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saver Guide: Tips on Saving Money and Energy at Home

Follow the simple tips in the Energy Saver guide to make your home more comfortable and easier to heat and cool--while you save money. This guide shows you how easy it is to cut your energy use at home and also on the road.

Guide, Tips, Money, Home, Saver, Consumer, Energy ↗

Equitable and Affordable Solutions to Electrification (EAS-E) Home Electrification Prize

The Equitable and Affordable Solutions to Electrification (EAS-E) Home Electrification Prize, EAS-E Prize, seeks novel, cost-effective technology solutions for whole-home electrification of all types of residential buildings. EAS-E Prize competitors will develop and demonstrate "easy electrification" approaches that are faster and more affordable for homeowners and simplify electrification processes for contractors and implementers.

EAS-E↗

Agent-Based Model of Combined Community- and Jail-Based Take-Home Naloxone Distribution

Importance Opioid-related overdose accounts for almost 80 000 deaths annually across the US. People who use drugs leaving jails are at particularly high risk for opioid-related overdose and may benefit from take-home naloxone (THN) distribution. Objective To estimate the population impact of THN distribution at jail release to reverse opioid-related overdose among people with opioid use disorders. Design, Setting, and Participants This study developed the agent-based Justice-Community Circulation Model (JCCM) to model a synthetic population of individuals with and without a history of opioid use. Epidemiological data from 2014 to 2020 for Cook County, Illinois, were used to identify parameters pertinent to the synthetic population. Twenty-seven experimental scenarios were examined to capture diverse strategies of THN distribution and use. Sensitivity analysis was performed to identify critical mediating and moderating variables associated with population impact and a proxy metric for cost-effectiveness (ie, the direct costs of THN kits distributed per death averted). Data were analyzed between February 2022 and March 2024. Intervention Modeled interventions included 3 THN distribution channels: community facilities and practitioners; jail, at release; and social network or peers of persons released from jail. Main Outcomes and Measures The primary outcome was the percentage of opioid-related overdose deaths averted with THN in the modeled population relative to a baseline scenario with no intervention. Results Take-home naloxone distribution at jail release had the highest median (IQR) percentage of averted deaths at 11.70% (6.57%-15.75%). The probability of bystander presence at an opioid overdose showed the greatest proportional contribution (27.15%) to the variance in deaths averted in persons released from jail. The estimated costs of distributed THN kits were less than $\$$15 000 per averted death in all 27 scenarios. Conclusions and Relevance This study found that THN distribution at jail release is an economical and feasible approach to substantially reducing opioid-related overdose mortality. Training and preparation of proficient and willing bystanders are central factors in reaching the full potential of this intervention.

Tatara, Eric [Argonne National Laboratory (ANL), A↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗