Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hollow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design and Manufacturing Processes of Long-Life Hollow Cathode Assemblies

The design and manufacturing processes for Hollow Cathode Assemblies (HCA's) that operate over a broad range of emission currents up to 30 Amperes, at low potentials, with lifetimes in excess of 17,500 hours. The processes include contamination control procedures which cover hollow cathode component cleaning procedures, gas feed system designs and specifications, and hollow cathode activation and operating procedures to thereby produce cathode assemblies that have demonstrated stable and repeatable operating conditions, for both the discharge current and voltage. The HCA of this invention provides lifetimes of greater than 10,000 hours, and expected lifetimes of greater than 17,500 hours, whereas the present state-of-the-art is less than 500 hours at emission currents in excess of 1 Ampere. Stable operation is provided over a large range of operating emission currents, up to a 6:1 ratio, and this HCA can emit electron currents of up to 30 Amperes in magnitude to an external anode that simulates the current drawn to a space plasma at voltages of less than 20 Volts.

Michael J Patterson↗

Hollow Retroreflectors

A hollow retroreflector is a mirror-like instrument that reflects light and other radiations back to the source. After developing a hollow retroreflector for NASA's Apollo-Soyuz mission, PLX, Inc. continued to expand the technology and develop a variety of retroreflector systems. The Lateral Transfer Hollow Retroreflector maintains precise separation, at any wavelength, of incoming and existing beams regardless of their orientation. It can be used as an instrument or as a component of an optical system. In the laboratory, it offers a new efficient means of beam positioning. In other applications, it connects laser resonators, aligns telescope mirrors and is useful in general boresighting and alignment.

Source record↗

Comparison of On-orbit and Ground Based Hollow Cathode Operation

The Plasma Contactor Units (PCUs) were developed at NASA Glenn Research Center (GRC) and Boeing for charge control on board the International Space Station (ISS). Since the first ignition of a PCU on 10/16/2000 over 3,900 hours of operation have been demonstrated on a single unit. In order to guarantee that the PCUs hollow cathode assemblies (HCAs), which emit the electrons used for charge control, would satisfy the life requirement of 18,000 hours, a ground based hollow cathode life test program was initiated at GRC. The life test program aimed at 27,000 hours of operation on a single unit to demonstrate the industry standard 1.5 times operational life requirement. As of this printing, over 18,000 hours of operation have been accumulated on a single hollow cathode. By comparing the data received from the on-orbit HCAs to the data obtained for the life test cathodes, a comparison may be drawn to determine if the on-orbit HCAs are operating normally, with a final goal of predicting lifetime. Based on the data taken thus far, it can be concluded that the on-orbit HCAs are operating within their design specifications.

Patterson, Michael↗

The Hollow Spheres of the Orgueil Meteorite: A Re-Examination

In 1971, Rossignol-Strick and Barghoorn provided images and a description of a number of spherical hollow microstructures showing well-defined walls in acid macerated extract of the Orgueil CI carbonaceous meteorite. Other forms such as membranes and spiral shaped structures were also reported. The carbon-rich (kerogen) hollow spheres were found to be in a narrowly constrained distribution of sizes (mainly 7 to 10 microns in diameter). Electron microprobe analysis revealed that these spheres contained Carbon, possibly P, N, and K. It was established that these forms could not be attributed to pollen or other recent terrestrial contaminants. It was concluded that they most probably represented organic coatings on globules of glass, olivine or magnetite in the meteorite. However, recent studies of the Orgueil meteorite have been carried out at the NASA/Marshall Space Flight Center with the S-4000 Hitachi Field Emission Scanning Electron Microscope (FESEM). These investigations have revealed the presence of numerous carbon encrusted spherical magnetite platelets and spherical and ovoidal bodies of elemental iron in-situ in freshly fractured interior surfaces of the meteorite. Their size range is also very narrowly constrained (typically approximately 6 to 12 microns) in diameter. High resolution images reveal that these bodies are also encrusted with a thin carbonaceous sheath and are surrounded by short nanofibrils that are shown to be composed of high purity iron by EDAX elemental analysis. We present Secondary and Backscatter Electron FESEM images and associated EDAX elemental analyses and 2D X-ray maps of these forms as we re-examine the hollow spheres of Orgueil and attempt to determine if they are representatives of the same population of indigenous microstructures.

Hoover, Richard B.↗

Process for testing a xenon gas feed system of a hollow cathode assembly

The design and manufacturing processes for Hollow Cathode Assemblies (HCA's) that operate over a broad range of emission currents up to 30 Amperes, at low potentials, with lifetimes in excess of 17,500 hours. The processes include contamination control procedures which cover hollow cathode component cleaning procedures, gas feed system designs and specifications, and hollow cathode activation and operating procedures to thereby produce cathode assemblies that have demonstrated stable and repeatable operating conditions, for both the discharge current and voltage. The HCA of this invention provides lifetimes of greater than 10,000 hours, and expected lifetimes of greater than 17,500 hours, whereas the present state-of-the-art is less than 500 hours at emission currents in excess of 1 Ampere. Stable operation is provided over a large range of operating emission currents, up to a 6:1 ratio, and this HCA can emit electron currents of up to 30 Amperes in magnitude to an external anode that simulates the current drawn to a space plasma, at voltages of less than 20 Volts.

Patterson, Michael J.↗

A Hollow-Waveguide Gas Correlation Radiometer for Ultra-Precise Column Measurements of Formaldehyde on Mars

We present preliminary results in the development of a miniaturized gas correlation radiometer that implements a hollow-core optical fiber (hollow waveguide) gas correlation cell. The substantial reduction in mass and volume of the gas correlation cell makes this technology appropriate for an orbital mission -- capable of pinpointing sources of trace gases in the Martian atmosphere. Here we demonstrate a formaldehyde (H2CO) sensor and report a detection limit equivalent to approximately 30 ppb in the Martian atmosphere. The relative simplicity of the technique allows it to be expanded to measure a range of atmospheric trace gases of interest on Mars such as methane (CH4), water vapour (H2O), deuterated water vapour (HDO), and methanol (CH3OH). Performance of a formaldehyde instrument in a Mars orbit has been simulated assuming a 3 meter long, 1000 micron inner diameter hollow-core fiber gas correlation cell, a 92.8 degree sun-synchronous orbit from 400 km with a horizontal sampling scale of 10 km x 10 km. Initial results indicate that for one second of averaging, a detection limit of 1 ppb is possible.

Wilson, Emily L.↗

Improved Rare-Earth Emitter Hollow Cathode

An improvement has been made to the design of the hollow cathode geometry that was created for the rare-earth electron emitter described in Compact Rare Earth Emitter Hollow Cathode (NPO-44923), NASA Tech Briefs, Vol. 34, No. 3 (March 2010), p. 52. The original interior assembly was made entirely of graphite in order to be compatible with the LaB6 material, which cannot be touched by metals during operation due to boron diffusion causing embrittlement issues in high-temperature refractory materials. Also, the graphite tube was difficult to machine and was subject to vibration-induced fracturing. This innovation replaces the graphite tube with one made out of refractory metal that is relatively easy to manufacture. The cathode support tube is made of molybdenum or molybdenum-rhenium. This material is easily gun-bored to near the tolerances required, and finish machined with steps at each end that capture the orifice plate and the mounting flange. This provides the manufacturability and robustness needed for flight applications, and eliminates the need for expensive e-beam welding used in prior cathodes. The LaB6 insert is protected from direct contact with the refractory metal tube by thin, graphite sleeves in a cup-arrangement around the ends of the insert. The sleeves, insert, and orifice plate are held in place by a ceramic spacer and tungsten spring inserted inside the tube. To heat the cathode, an insulating tube is slipped around the refractory metal hollow tube, which can be made of high-temperature materials like boron nitride or aluminum nitride. A screw-shaped slot, or series of slots, is machined in the outside of the ceramic tube to constrain a refractory metal wire wound inside the slot that is used as the heater. The screw slot can hold a single heater wire that is then connected to the front of the cathode tube by tack-welding to complete the electrical circuit, or it can be a double slot that takes a bifilar wound heater with both leads coming out the back. This configuration replaces the previous sheathed heater design that limited the cycling-life of the cathode.

Goebel, Dan M.↗

Co-Flow Hollow Cathode Technology

Hall thrusters utilize identical hollow cathode technology as ion thrusters, yet must operate at much higher mass flow rates in order to efficiently couple to the bulk plasma discharge. Higher flow rates are necessary in order to provide enough neutral collisions to transport electrons across magnetic fields so that they can reach the discharge. This higher flow rate, however, has potential life-limiting implications for the operation of the cathode. A solution to the problem involves splitting the mass flow into the hollow cathode into two streams, the internal and external flows. The internal flow is fixed and set such that the neutral pressure in the cathode allows for a high utilization of the emitter surface area. The external flow is variable depending on the flow rate through the anode of the Hall thruster, but also has a minimum in order to suppress high-energy ion generation. In the co-flow hollow cathode, the cathode assembly is mounted on thruster centerline, inside the inner magnetic core of the thruster. An annular gas plenum is placed at the base of the cathode and propellant is fed throughout to produce an azimuthally symmetric flow of gas that evenly expands around the cathode keeper. This configuration maximizes propellant utilization and is not subject to erosion processes. External gas feeds have been considered in the past for ion thruster applications, but usually in the context of eliminating high energy ion production. This approach is adapted specifically for the Hall thruster and exploits the geometry of a Hall thruster to feed and focus the external flow without introducing significant new complexity to the thruster design.

Hofer, Richard R.↗

Miniaturized Hollow-Waveguide Gas Correlation Radiometer (GCR) for Trace Gas Detection in the Martian Atmosphere

Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Here, we present a miniaturized and simplified version of this instrument capable of mapping multiple trace gases and identifying active regions on the Mars surface. Reduction of the size and mass of the GCR instrument has been achieved by implementing a lightweight, 1 mm inner diameter hollow-core optical fiber (hollow waveguide) for the gas correlation cell. Based on a comparison with an Earth orbiting CO2 gas correlation instrument, replacement of the 10 meter mUltipass cell with hollow waveguide of equivalent pathlength reduces the cell mass from approx 150 kg to approx 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately I meter in diameter by 0.05 m in height (mass and volume reductions of >99%). This modular instrument technique can be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance.

Wilson, Emily L.↗

Hollow-Fiber Spacesuit Water Membrane Evaporator

The hollow-fiber spacesuit water membrane evaporator (HoFi SWME) is being developed to perform the thermal control function for advanced spacesuits and spacecraft to take advantage of recent advances in micropore membrane technology in providing a robust, heat-rejection device that is less sensitive to contamination than is the sublimator. After recent contamination tests, a commercial-off-the-shelf (COTS) micro porous hollow-fiber membrane was selected for prototype development as the most suitable candidate among commercial hollow-fiber evaporator alternatives. An innovative design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was developed into a full-scale prototype for the spacesuit application. Vacuum chamber testing has been performed to characterize heat rejection as a function of inlet water temperature and water vapor back-pressure, and to show contamination resistance to the constituents expected to be found in potable water produced by the wastewater reclamation distillation processes. Other tests showed tolerance to freezing and suitability to reject heat in a Mars pressure environment. In summary, HoFi SWME is a lightweight, compact evaporator for heat rejection in the spacesuit that is robust, contamination- insensitive, freeze-tolerant, and able to reject the required heat of spacewalks in microgravity, lunar, and Martian environments. The HoFi is packaged to reject 810 W of heat through 800 hours of use in a vacuum environment, and 370 W in a Mars environment. The device also eliminates free gas and dissolved gas from the coolant loop.

Bue, Grant↗

Operational Status of the International Space Station Plasma Contactor Hollow Cathode Assemblies July 2001 to May 2013

The International Space Station has onboard two Aerojet Rocketdyne developed plasma contactor units that perform the function of charge control. The plasma contactor units contain NASA Glenn Research Center developed hollow cathode assemblies. NASA Glenn Research Center monitors the on-orbit operation of the flight hollow cathode assemblies. As of May 31, 2013, HCA.001-F has been ignited and operated 123 times and has accumulated 8072 hours of operation, whereas, HCA.003-F has been ignited and operated 112 times and has accumulated 9664 hours of operation. Monitored hollow cathode ignition times and anode voltage magnitudes indicate that they continue to operate nominally.

Kamhawi, Hani↗

Development and Testing of High Current Hollow Cathodes for High Power Hall Thrusters

NASA's Office of the Chief Technologist In-Space Propulsion project is sponsoring the testing and development of high power Hall thrusters for implementation in NASA missions. As part of the project, NASA Glenn Research Center is developing and testing new high current hollow cathode assemblies that can meet and exceed the required discharge current and life-time requirements of high power Hall thrusters. This paper presents test results of three high current hollow cathode configurations. Test results indicated that two novel emitter configurations were able to attain lower peak emitter temperatures compared to state-of-the-art emitter configurations. One hollow cathode configuration attained a cathode orifice plate tip temperature of 1132 degC at a discharge current of 100 A. More specifically, test and analysis results indicated that a novel emitter configuration had minimal temperature gradient along its length. Future work will include cathode wear tests, and internal emitter temperature and plasma properties measurements along with detailed physics based modeling.

Kamhawi, Hani↗

12Cao-7Al2o3 Electride Hollow Cathode

The use of the electride form of 12CaO-7Al.sub.2O.sub.3, or C12A7, as a low work function electron emitter in a hollow cathode discharge apparatus is described. No heater is required to initiate operation of the present cathode, as is necessary for traditional hollow cathode devices. Because C12A7 has a fully oxidized lattice structure, exposure to oxygen does not degrade the electride. The electride was surrounded by a graphite liner since it was found that the C12A7 electride converts to it's eutectic (CA+C3A) form when heated (through natural hollow cathode operation) in a metal tube.

Rand, Lauren P.↗

Hollow-Core Fiber Lamp

Hollow-core capillary discharge lamps on the millimeter or sub-millimeter scale are provided. The hollow-core capillary discharge lamps achieve an increased light intensity ratio between 194 millimeters (useful) and 254 millimeters (useless) light than conventional lamps. The capillary discharge lamps may include a cone to increase light output. Hollow-core photonic crystal fiber (HCPCF) may also be used.

Yi, Lin↗

12CaO-7Al2O3 Electride Hollow Cathode

The use of the electride form of 12CaO-7Al2O3, or C12A7, as a low work function electron emitter in a hollow cathode discharge apparatus is described. No heater is required to initiate operation of the present cathode, as is necessary for traditional hollow cathode devices. Because C12A7 has a fully oxidized lattice structure, exposure to oxygen does not degrade the electride. The electride was surrounded by a graphite liner since it was found that the C12A7 electride converts to it's eutectic (CA+C3A) form when heated (through natural hollow cathode operation) in a metal tube.

Rand, Lauren P.↗

First-Principles Modeling of IAT-Driven Anomalous Resistivity in Hollow Cathode Discharges II: Numerical Simulations and Comparisons with Experiments

We present a model that quantifies the magnitude of the ion-acoustic turbulence (IAT) in the plume of hollow cathodes and its effect on the resistivity and ion heating. The model takes the form of a partial differential equation (PDE) that can be solved concurrently with the equations of motion for a partially ionized plasma already included in our numerical code for the simulation of the plasma discharge in hollow cathodes, OrCa2D. We also determine that self-induced magnetic fields are not negligible in hollow cathodes operating at large discharge currents and implement in our code Ampere’s law and modifications to Ohm’s law that account for this effect. Numerical simulations that employed these models show large improvements in our agreement with experimental measurements with respect to a previous model, which assumed complete saturation of the IAT and did not account for the growth stage of the waves. In particular, the model is able to accurately predict the location and magnitude of the maximum resitivity to the electron current along the cathode centerline.

Lopez Ortega, Alejandro↗

Using a "HOLLoW" Design for Traditional Shuttle Tiles to Reduce Mass up to 30%

For spacecraft entering an atmosphere, a reduction in TPS mass is directly proportional to the increase in payload mass. The HOLLOW TPS concept is a reusable material with lower density and similar thermal capabilities to traditional tiles. Using HOLLOW TPS to replace a percentage of the tiles on a flight vehicle could save up to 35% mass depending on the mission objectives and flight path. The HOLLOW TPS will also increase an equal amount of payload capacity, increasing the efficiency of the mission.

Peterson, Keith H.↗