Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Magnetization of planar four-fermion systems

We consider a planar system of fermions, at finite temperature and density under a static magnetic field parallel to the two-dimensional plane. This magnetic field generates a Zeeman effect and then a spin polarization of the system. The critical properties are studied from the Landau's free energy. The possible observable consequences of the magnetization of planar systems such as polymer films and graphene are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-generation of megagauss magnetic fields during the expansion of a plasma

The expansion of a plasma slab into a vacuum is studied using one-dimensional and two-dimensional particle-in-cell simulations. As electrons transfer their longitudinal kinetic energy to ions during the expansion, the electron temperature becomes anisotropic. Once this anisotropy exceeds a threshold value, it drives the Weibel instability, leading to magnetic fields in the megagauss range. These fields induce energy transfer between the longitudinal and transverses directions, which influences the expansion. The impact of a cold electron population on this phenomenon is also investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the Weibel instability on the expansion of a plasma slab into a vacuum

The development of the Weibel instability during the expansion of a thin plasma foil heated by an intense laser pulse is investigated, using both analytical models and relativistic particle-in-cell simulations. When the plasma has initially an anisotropic electron distribution, this electromagnetic instability develops from the beginning of the expansion. Then it contributes to suppress the anisotropy and eventually saturates. After the saturation, the strength of the magnetic field decreases because of the plasma expansion until it becomes too weak to maintain the distribution isotropic. For this time, the anisotropy rises as electrons give progressively their longitudinal energy to ions, so that a new instability can develop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Evidence of Predominantly Transverse Electron Plasma Waves Driven by Stimulated Raman Scattering of Picosecond Laser Pulses

We report on highly time- and space-resolved measurements of the evolution of electron plasma waves driven by stimulated Raman scattering of a picosecond, single laser speckle propagating through a preformed underdense plasma. Two-dimensional Thomson scatter spectra indicate that the dominant waves have significant transverse components. These results are supported by particle-in-cell simulations which pinpoint the dominant role of the wave front bowing and of secondary nonlinear electrostatic instabilities in the evolution of the plasma waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Evidence of Short Light Pulse Amplification Using Strong-Coupling Stimulated Brillouin Scattering in the Pump Depletion Regime

The energy transfer from a long (3.5 ps) pump pulse to a short (400 fs) seed pulse due to stimulated Brillouin backscattering in the strong-coupling regime is investigated. The two pulses, both at the same wavelength of 1.057 {mu}m are quasicounterpropagating in a preformed underdense plasma. Relative amplification factors for the seed pulse of up to 32 are obtained. The maximum obtained amplified energy is 60 mJ. Simulations are in agreement with the experimental results and suggest paths for further improvement of the amplification scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic frustration control through tunable stereochemically driven disorder in entropy-stabilized oxides

Entropy-stabilized oxides possess a large configurational entropy that allows for the unique ability to include typically immiscible concentrations of species in different configurations. Particularly in oxides, where the physical behavior is strongly correlated to stereochemistry and electronic structure, entropic stabilization creates a unique platform to tailor the interplay of extreme structural and chemical disorder to realize unprecedented functionalities. Here, we control stereochemically driven structural disorder in single crystalline, rocksalt, (MgCoNiCuZn)O-type entropy-stabilized oxides through the incorporation of Cu 2+ cations. We harness the disorder to tune the degree of glassiness in the antiferromagnetic structure. Structural distortions driven by the Jahn-Teller effect lead to a difference in valence on the Co cation sites, which extends to dilution and disorder of the magnetic lattice. A spin glass model reveals that the fractional spin ordering of the magnetic lattice can be tuned by ~65%. These findings demonstrate entropy-stabilization as a tool for control of functional phenomena.

36 MATERIALS SCIENCE↗

Intertwined Polar, Chiral, and Ferro-Rotational Orders in a Homo-Ferro-Rotational Insulator

Intertwined orders refer to strongly coupled and mutually dependent orders that coexist in correlated electron systems, often underpinning key physical properties of the host materials. Among them, polar, chiral, and ferro-rotational orders have been theoretically known to form a closed set of intertwined orders. However, experimental investigation into their mutual coupling and physical consequences has remained elusive. In this work, we employ the polar-chiral insulator Ni 3 ⁢TeO 6 as a platform and utilize a multimodal optical approach to directly probe and reveal the intertwining among polarity, chirality, and ferro-rotational order. We demonstrate how their coupling governs the formation of domains and dictates the nature of domain walls. Within the domains, we identify spatial inversion symmetry as the operation connecting two domain states of opposite polarity and chirality, with a homo-ferro-rotational state serving as the prerequisite for these interlocked configurations. At the domain walls, we observe a pronounced enhancement of in-plane polarization accompanied by a suppression of chirality. By combining with Ginzburg-Landau theory within the framework of a preexisting homo-ferro-rotational background, we uncover the emergence of mixed Néel- and Bloch-type domain walls. Our findings highlight the critical role of intertwined orders in defining domain and domain-wall characteristics and open pathways for domain switching and domain-wall control via intertwined order parameters.

Zhang, Weizhe [University of Michigan, Ann Arbor, ↗

Practical Integration Approach and Whole Building Energy Simulation of Three Energy Efficient Building Technologies: Preprint

Three technologies that have potential to save energy and improve sustainability of buildings are dedicated outdoor air systems, radiant heating and cooling systems and tighter building envelopes. To investigate the energy savings potential of these three technologies, whole building energy simulations were performed for a barracks facility and an administration facility in 15 U.S. climate zonesand 16 international locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dosimetric evaluations of the interplay effect in respiratory-gated intensity-modulated radiation therapy

The interplay between a mobile target and a dynamic multileaf collimator can compromise the accuracy of intensity-modulated radiation therapy (IMRT). Our goal in this study is to investigate the dosimetric effects caused by the respiratory motion during IMRT. A moving phantom was built to simulate the typical breathing motion. Different sizes of the gating windows were selected for gated deliveries. The residual motions during the beam-on period ranged from 0.5 to 3 cm. An IMRT plan with five treatment fields from different gantry angles were delivered to the moving phantom for three irradiation conditions: Stationary condition, moving with the use of gating system, and moving without the use of gating system. When the residual motion was 3 cm, the results showed significant differences in dose distributions between the stationary condition and the moving phantom without gating beam control. The overdosed or underdosed areas enclosed about 33% of the treatment area. In contrast, the dose distribution on the moving phantom with gating window set to 0.5 cm showed no significant differences from the stationary phantom. With the appropriate setting of the gating window, the deviation of dose from the respiratory motion can be minimized. It appeals that limiting the residual motion to less than 0.5 cm is critical for the treatments of mobile structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view

Purpose: Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method to increase the FOV for current on-board CBCT systems. Methods: When a large patient is scanned with CBCT, any region outside the FOV is only partially sampled within a short range of projection angles, and at other angles no x-ray beams may pass through that region. To increase the sampling rate for the region outside the FOV, we have designed a new source trajectory by shifting the center of rotation during a CBCT scan. This resulted in a reduced sampling rate at the central area and increased sampling rate at the edges. The tradeoff led to a more balanced sampling for an enlarged FOV. An iterative algorithm was also developed to reconstruct the CT image under the new sampling scheme using a compressed sensing technique. Results: The method was validated by numerical simulations mimicking a Varian Trilogy CBCT system, and it was found that artifact-free images could be obtained with the FOV as large as 80 cm. Conclusions: The new CT scanning trajectory can be easily realized under current clinical setup with little modification of the control system, and this can be useful for treating obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor excursion outside of the gating window, which, for our study group, is mainly caused by baseline shift, i.e., the change in general trend of the motion curve during extended period of treatment time. Conclusions: The dose deviation in PTV and CTV due to target motion is not always negligible in gated SBRT. Although CTVs are covered sufficiently with prescribed dose in most cases, some are on the verge of underdose due to large tumor excursion caused by factors such as baseline shift.

60 APPLIED LIFE SCIENCES↗

Simultaneous reduction of radiation dose and scatter for CBCT by using collimators

Purpose: On-board cone-beam CT (CBCT) imaging has been widely available in radiotherapy clinic for target localization. However, the extra radiation dose from CBCT is always a concern for its frequent use. Additionally, the relatively large scatter in CBCT often degrades the image quality. By using collimators, some of the X-rays can be stopped from reaching the patient and the detectors, hence both the scatter and the patient doses are simultaneously reduced. The authors show in this work that the collimated CBCT data can be reconstructed without any noticeable artifacts for certain collimator blocking ratios and blocking patterns, and the focus of this work is to study the relationship between the image quality and these two collimator factors.Methods: A CBCT system with collimators was simulated following the typical geometry used in clinic. Different collimator designs were tested by varying the size and the number of the collimator slits, and at the same time, the ratio of transmitted beams to total beams was varied from 100% to 10%, resulting in hundreds of different simulation scenarios. Lung and pelvis phantoms created from patients CT images were used in the simulations, and an iterative reconstruction algorithm using the compressed sensing technique was adopted. The image quality was examined by root mean square errors (RMSEs) and compared with the conventional CBCT images.Results: The CBCT image quality increases as the amount of beams passing through the collimators increases, and decreases as the size of the collimator slits increases. With ultra-high resolution collimators, the RMSEs were comparable to the conventional CBCT image quality until the beam transmission rate is reduced below 25%.Conclusions: Collimators can reduce the scatters and radiation dose, however, the collimated CBCT image quality is strongly dependent on both the collimator blocking ratio and the blocking pattern. To achieve image quality comparable to the conventional CBCT, the amount of information and data format must be adequate.

61 RADIATION PROTECTION AND DOSIMETRY↗

The use of strain tensor to estimate thoracic tumors deformation

Purpose: Respiration-induced kinematics of thoracic tumors suggests a simple analogy with elasticity, where a strain tensor is used to characterize the volume of interests. The application of the biomechanical framework allows for the objective determination of tumor characteristics. Methods: Four-dimensional computed tomography provides the snapshots of the patient's anatomy at the end of inspiration and expiration. Image registration was used to obtain the displacement vector fields and deformation fields, which allows one for the determination of the strain tensor. Its departure from the identity matrix gauges the departure of the medium from rigidity. The tensorial characteristic of each GTV voxel was determined and averaged. To this end, the standard Euclidean matrix norm as well as the Log-Euclidean norm were employed. Tensorial anisotropy was gauged with the fractional anisotropy measure which is based on the normalized variance of the tensors eigenvalues. Anisotropy was also evaluated with the geodesic distance in the Log-Euclidean framework of a given strain tensor to its closest isotropic counterpart. Results: The averaged strain tensor was determined for each of the 15 retrospectively analyzed thoracic GTVs. The amplitude of GTV motion varied from 0.64 to 4.21 with the average of 1.20 cm. The GTV size ranged from 5.16 to 149.99 cc with the average of 43.19 cc. The tensorial analysis shows that deformation is inconsiderable and that the tensorial anisotropy is small. The Log-Euclidean distance of averaged strain tensors from the identity matrix ranged from 0.06 to 0.31 with the average of 0.19. The Frobenius distance from the identity matrix is similar and ranged from 0.06 to 0.35 with the average of 0.21. Their fractional anisotropy ranged from 0.02 to 0.12 with the average of 0.07. Their geodesic anisotropy ranged from 0.03 to 0.16 with the average of 0.09. These values also indicate insignificant deformation. Conclusions: The tensorial framework allows for direct measurements of tissue deformation. It goes beyond the evaluation of deformation via comparison of shapes. It is an independent and objective determination of tissue properties. This methodology can be used to determine possible changes in lung properties due to radiation therapy and possible toxicities.

60 APPLIED LIFE SCIENCES↗

SU-E-J-185: Gated CBCT Imaging for Positioning Moving Lung Tumor in Lung SBRT Treatment

Purpose: Lung stereo-tactic body radiotherapy(SBRT) treatment requires high accuracy of lung tumor positioning during treatment, which is usually accomplished by free breathing Cone-Beam computerized tomography (CBCT) scan. However, respiratory motion induced image artifacts in free breathing CBCT may degrade such positioning accuracy. The purpose of this study is to investigate the feasibility of gated CBCT imaging for lung SBRT treatment. Methods: Six Lung SBRT patients were selected for this study. The respiratory motion of the tumors ranged from 1.2cm to 3.5cm, and the gating windows for all patients were set between 35% and 65% of the respiratory phases. Each Lung SBRT patient underwent free-breathing CBCT scan using half-fan scan technique. The acquired projection images were transferred out for off-line analyses. An In-house semi-automatic algorithm was developed to trace the diaphragm movement from those projection images to acquire a patient's specific respiratory motion curve, which was used to correlate respiratory phases with each projection image. Afterwards, a filtered back-projection algorithm was utilized to reconstruct the gated CBCT images based on the projection images only within the gating window. Results: Target volumes determined by free breathing CBCT images were 71.9%±72% bigger than the volume shown in gated CBCT image. On the contrary, the target volume differences between gated CBCT and planning CT images at exhale stage were 5.8%±2.4%. The center to center distance of the targets shown in free breathing CBCT and gated CBCT images were 9.2±8.1mm. For one particular case, the superior boundary of the target was shifted 15mm between free breathing CBCT and gated CBCT. Conclusion: Gated CBCT imaging provides better representation of the moving lung tumor with less motion artifacts, and has the potential to improve the positioning accuracy in lung SBRT treatment.

60 APPLIED LIFE SCIENCES↗