Ion cyclotron heating at high plasma density in Proto-MPEX

The physics of ion cyclotron heating (ICH) relevant to the steady-state linear machine MPEX (Material Plasma Exposure eXperiment) has been explored in its predecessor, short-pulse device: Proto-MPEX. MPEX will utilize fundamental ICH to increase heat flux at the target and produce ion temperatures and velocity distributions with improved fidelity to those found in a tokamak divertor region, in comparison to those produced by substrate biasing. In the experiments on Proto-MPEX described here, bulk ion temperatures up to ~15 eV have been achieved with 20 kW net ICH power at 6.5 MHz, using ICH heating of a deuterium plasma produced by a helicon plasma source. The heat flux at the target has been observed to increase throughout the plasma cross section, including in the core region. Core $T_i$ and target heat flux are observed to scale linearly with injected ICH power. Further, measurements of plasma loading and target heat flux as a function of the magnetic field strength at the antenna, together with modeling of the wave propagation from the antenna to the ion cyclotron resonance using the ANTENA and COMSOL codes with a warm plasma dielectric tensor, indicate that power is coupled to the core plasma via fast wave excitation of a kinetic Alfvén wave.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results of Ion Cyclotron Heating Experiments on Proto-MPEX Utilizing a Movable Stainless Steel Target

Ion cyclotron heating (ICH) at a frequency in the 6- to 9-MHz range with electron heating in the 28- to 105-GHz range will be used in the Material Plasma Exposure eXperiment (MPEX) to greatly increase the energy of the plasma stream produced by the helicon plasma source. ICH was chosen over substrate biasing to produce energetic ions because it can more accurately reproduce plasma-material interactions in a fusion device. For instance, when the target is tilted with respect to the background magnetic field during ICH, a magnetic presheath is created so that redeposition phenomena as in a tokamak divertor can be better approximated. ICH experiments were conducted on the Proto-MPEX device, which was developed to provide a physics basis upon which MPEX is designed. In this paper we describe some of these experiments in which the previous fixed graphite target was replaced by a movable stainless steel target. With the new target, the strong, monotonic decrease in ion temperature observed previously as a function of axial distance between the ion cyclotron resonance region and the target was not observed. Instead, only a small drop was seen within ~1 cm of the target. The ion temperatures were determined spectroscopically, utilizing Doppler broadening measurements of an Ar II line, in a plasma that is 90% deuterium and 10% argon. Measurements were obtained using optical fibers at a fixed location, with the target moving perpendicularly relative to the viewing chords. Comparisons with previous results will be discussed, including observed plasma parameters Ti, Te, and ne, and heat flux at the target.

Goulding, Richard↗

Initial experimental test of a helicon plasma based mass filter

High throughput plasma mass separation requires rotation control in a high density multi-species plasmas. A preliminary mass separation device based on a helicon plasma operating in gas mixtures and featuring concentric biasable ring electrodes is introduced. Plasma profile shows strong response to electrode biasing. In light of floating potential measurements, the density response is interpreted as the consequence of a reshaping of the radial electric field in the plasma. This field can be made confining or de-confining depending on the imposed potential at the electrodes, in a way which is consistent with single particle orbit radial stability. In conclusion, concurrent spatially resolved spectroscopic measurements suggest ion separation, with heavy to light ion emission line ratio increasing with radius when a specific potential gradient is applied to the electrodes.

42 ENGINEERING↗

Study on monatomic fraction improvement with alumina layer on metal electrode in hydrogen plasma ion source

A high monatomic beam fraction is an important factor in a hydrogen ion source to increase the application efficiency. The monatomic fraction of hydrogen plasmas with different plasma electrode materials is measured in a helicon plasma ion source, and aluminum shows the highest value compared to that with the other metals such as copper and molybdenum. Formation of an aluminum oxide layer on the aluminum electrode is determined by XPS analysis, and the alumina layer is verified as the high monatomic fraction. Both experiments and numerical simulations conclude that a low surface recombination coefficient of the alumina layer on the plasma electrode is one of the most important parameters for increasing the monatomic fraction in hydrogen plasma ion sources.

43 PARTICLE ACCELERATORS↗

Helicon Wave Physics Impacts on Electrodeless Thruster Design

Effective generation of helicon waves for high density plasma sources is determined by the dispersion relation and plasma power balance. Helicon wave plasma sources inherently require an applied magnetic field of .01-0.1 T, an antenna properly designed to couple to the helicon wave in the plasma, and an rf power source in the 10-100 s of MHz, depending on propellant choice. For a plasma thruster, particularly one with a high specific impulse (>2000 s), the physics of the discharge would also have to address the use of electron cyclotron resonance (ECR) heating and magnetic expansion. In all cases the system design includes an optimized magnetic field coil, plasma source chamber, and antenna. A preliminary analysis of such a system, calling on experimental data where applicable and calculations where required, has been initiated at Glenn Research Center. Analysis results showing the mass scaling of various components as well as thruster performance projections and their impact on thruster size are discussed.

Gilland, James↗

Helicon Wave Physics Impacts on Electrodeless Thruster Design

Effective generation of helicon waves for high density plasma sources is determined by the dispersion relation and plasma power balance. Helicon wave plasma sources inherently require an applied magnetic field of .01-0.1 T, an antenna properly designed to couple to the helicon wave in the plasma, and an rf power source in the 10-100 s of MHz, depending on propellant choice. For a plasma thruster, particularly one with a high specific impulse (>2000 s), the physics of the discharge would also have to address the use of electron cyclotron resonance (ECR) heating and magnetic expansion. In all cases the system design includes an optimized magnetic field coil, plasma source chamber, and antenna. A preliminary analysis of such a system, calling on experimental data where applicable and calculations where required, has been initiated at Glenn Research Center. Analysis results showing the mass scaling of various components as well as thruster performance projections and their impact on thruster size are discussed.

Gilland, James H.↗

Transport modeling of convection dominated helicon discharges in Proto-MPEX with the B2.5-Eirene code

Data-constrained interpretative analyses of plasma transport in convection dominated helicon discharges in the Proto-MPEX linear device, and predictive calculations with additional Electron Cyclotron Heating/Electron Bernstein Wave (ECH/EBW) heating, are reported. The B2.5-Eirene code, in which the multi-fluid plasma code B2.5 is coupled to the kinetic Monte Carlo neutrals code Eirene, is used to fit double Langmuir probe measurements and fast camera data in front of a stainless-steel target. The absorbed helicon and ECH power (11 kW) and spatially constant anomalous transport coefficients that are deduced from fitting of the probe and optical data are additionally used for predictive simulations of complete axial distributions of the densities, temperatures, plasma flow velocities, particle and energy fluxes, and possible effects of alternate fueling and pumping scenarios. The somewhat hollow electron density and temperature radial profiles from the probe data suggest that Trivelpiece-Gould wave absorption is the dominant helicon electron heating source in the discharges analyzed here. There is no external ion heating, but the corresponding calculated ion temperature radial profile is not hollow. Rather it reflects ion heating by the electron-ion equilibration terms in the energy balance equations and ion radial transport resulting from the hollow density profile. With the absorbed power and the transport model deduced from fitting the sheath limited discharge data, calculated conduction limited higher recycling conditions were produced by reducing the pumping and increasing the gas fueling rate, resulting in an approximate doubling of the target ion flux and reduction of the target heat flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual-pass upgrade to the Thomson scattering diagnostic on the Prototype-Material Plasma Exposure eXperiment (Proto-MPEX)

The Thomson scattering (TS) diagnostic on the Prototype-Material Plasma Exposure eXperiment has been upgraded to measure electron temperature (T e ) and density (n e ) simultaneously at two axial locations. After the first pass through the vacuum vessel, the exiting laser beamline is re-collimated in the atmosphere and rerouted into the vacuum vessel for the second pass. The upgrade will help diagnose axial T e and n e gradients between the “central chamber” and the target region which are located 1 m and 2.5 m, respectively, downstream from the Helicon radio-frequency source. The TS measurements have given T e ≈ 4–15 eV and n e ≈ 2–4 × 10 19 m -3 at the central chamber and T e ≈ 1–2 eV and n e ≈ 1–2 × 10 19 m -3 at the target region. The upgrade also increases the number of sampling points at the target region from 3 fibers to 5 fibers, measuring 3 cm radially across the plasma column, and 25 fibers in the central chamber, radially spanning 8 cm. The intensified CCD camera is double triggered for each laser pulse in order to measure (1) the TS and laser stray light and (2) the plasma background light that contains nuisance emission lines and bremsstrahlung. Subtracting the background light from the TS photons improves the temperature and density measurements. Details of the diagnostic setup, axial and radial measurements, and areas for further optimization are discussed.

dual-pass Thomson Scattering↗

H- ion source developments at the SNS

The U.S. Spallation Neutron Source (SNS) will require substantially higher average and pulse H- beam currents than can be produced from conventional ion sources such as the base line SNS source. H- currents of 40-50 mA (SNS operations) and 70-100 mA (power upgrade project) with an rms emittance of 0.20-0.35 Pi mm mrad and a ~7% duty factor will be needed. We are therefore investigating several advanced ion source concepts based on RF excitation. First, the performance characteristics of an external antenna source based on an Al2O3 plasma chamber combined with an external multicusp magnetic configuration, an elemental Cs system, and plasma gun will be discussed. Second, the first plasma measurements of a helicon-driven H- ion source will also be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RF sheath induced sputtering on Proto-MPEX part 2: Impurity transport modeling and experimental comparison

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a pulsed linear plasma device that uses a radio frequency (RF) helicon antenna and a helicon ceramic window as the plasma ionization source. Modeling performed within this work on the helicon operations predicts hot spots on the helicon ceramic window due to an RF-induced sheath. The RF sheath potential leads to physical sputtering of the ceramic window predominantly where the helicon antenna sits around the helicon window. The role of oxygen in sputtering within Proto-MPEX is also investigated and is needed to match the experimental data. Experiments on Proto-MPEX show reasonable agreement with the modeled erosion/redeposition pattern on the helicon window, and the modeled impurity flux to the target shows radial transport within the device as expected from classical collisional impurity transport. Temperature screening of impurities is shown to be needed for Proto-MPEX to reduce impurity flux to the target. The modeling approach used in this work can be applied to other plasma RF applications for the determination of impurity production and transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a helicon-wave excited plasma facility with high magnetic field for plasma–wall interactions studies

Here, the high magnetic field helicon experiment system is a helicon wave plasma (HWP) source device in a high axial magnetic field ( B 0 ) developed for plasma–wall interactions studies for fusion reactors. This HWP was realized at low pressure (5 × 10 –3 – 10 Pa) and a RF (radio frequency, 13.56 MHz) power (maximum power of 2 kW) using an internal right helical antenna (5 cm in diameter by 18 cm long) with a maximum B 0 of 6300 G. Ar HWP with electron density ~10 18 –10 20 m –3 and electron temperature ~4–7 eV was produced at high B 0 of 5100 G, with an RF power of 1500 W. Maximum Ar+ ion flux of 7.8 × 10 23 m –2 s –1 with a bright blue core plasma was obtained at a high B 0 of 2700 G and an RF power of 1500 W without bias. Plasma energy and mass spectrometer studies indicate that Ar + ion-beams of 40.1 eV are formed, which are supersonic (~3.1c s ). The effect of Ar HWP discharge cleaning on the wall conditioning are investigated by using the mass spectrometry. And the consequent plasma parameters will result in favorable wall conditioning with a removal rate of 1.1 × 10 24 N 2 /m 2 h.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct measurements of the ionization profile in krypton helicon plasmas

Helicons are efficient plasma sources, capable of producing plasma densities of 10{sup 19} m{sup -3} with only 100 s W of input rf power. There are often steep density gradients in both the neutral density and plasma density, resulting in a fully ionized core a few cm wide surrounded by a weakly ionized plasma. The ionization profile is usually not well known because the neutral density is typically inferred from indirect spectroscopic measurements or from edge pressure gauge measurements. We have developed a two photon absorption laser induced fluorescence (TALIF) diagnostic capable of directly measuring the neutral density profile. We use TALIF in conjunction with a Langmuir probe to measure the ionization fraction profile as a function of driving frequency, magnetic field, and input power. It is found that when the frequency of the driving wave is greater than a critical frequency, f{sub c} Almost-Equal-To 3f{sub lh}, where f{sub lh} is the lower hybrid frequency at the antenna, the ionization fraction is small (0.1%) and the plasma density low (10{sup 17} m{sup -3}). As the axial magnetic field is increased, or, equivalently, the driving frequency decreased, a transition is observed. The plasma density increases by a factor of 10 or more, the plasma density profile becomes strongly peaked, the neutral density profile becomes strongly hollow, and the ionization fraction in the core approaches 100%. Neutral depletion in the core can be caused by a number of mechanisms. We find that in these experiments the depletion is due primarily to plasma pressure and neutral pumping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Future carbon beams at SPIRAL1 facility: Which method is the most efficient?

Compared to in-flight facilities, Isotope Separator On-Line ones can in principle produce significantly higher radioactive ion beam intensities. On the other hand, they have to cope with delays for the release and ionization which make the production of short-lived isotopes ion beams of reactive and refractory elements particularly difficult. Many efforts are focused on extending the capabilities of ISOL facilities to those challenging beams. In this context, the development of carbon beams is triggering interest [H. Frånberg, M. Ammann, H. W. Gäggeler, and U. Köster, Rev. Sci. Instrum. 77, 03A708 (2006); M. Kronberger, A. Gottberg, T. M. Mendonca, J. P. Ramos, C. Seiffert, P. Suominen, and T. Stora, in Proceedings of the EMIS 2012 [Nucl. Instrum. Methods Phys. Res. B Production of molecular sideband radioisotope beams at CERN-ISOLDE using a Helicon-type plasma ion source (to be published)]: despite its refractory nature, radioactive carbon beams can be produced from molecules (CO or CO{sub 2}), which can subsequently be broken up and multi-ionized to the required charge state in charge breeders or ECR sources. This contribution will present results of experiments conducted at LPSC with the Phoenix charge breeder and at GANIL with the Nanogan ECR ion source for the ionization of carbon beams in the frame of the ENSAR and EMILIE projects. Carbon is to date the lightest condensable element charge bred with an ECR ion source. Charge breeding efficiencies will be compared with those obtained using Nanogan ECRIS and charge breeding times will be presented as well.

43 PARTICLE ACCELERATORS↗

Effect of magnetic field ripple on parallel electron transport during microwave plasma heating in the Proto-MPEX linear plasma device

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device located at Oak Ridge National Laboratory to develop the plasma source concept for the Materials Plasma Exposure eXperiment (MPEX). Recent experiments have demonstrated the heating of electrons in a high-density deuterium plasma (n e ~ 5 × 10 19 m -3 ) via electron Bernstein waves and source plasma production via helicon waves in this linear configuration. Moreover, experimental observations suggest that the magnetic ripple adversely affects the parallel transport of the heated electrons toward the target where material samples are to be exposed to the plasma. In order to understand the transport process during microwave application, a test-particle Monte-Carlo (MC) code has been developed that incorporates the effects of Coulomb collisions, magnetic mirror adiabatic trapping and electron cyclotron interaction via a quasilinear RF heating operator. MC calculations indicate that the absence of 2nd turning points along the trajectory of cyclotron heated electrons significantly reduces adiabatic trapping and maximizes power transport to the Target surface. Thermalization of cyclotron heating electrons is analyzed with the MC code and it is found that for conditions relevant to ProtoMPEX, a significant fraction of the absorbed heating power is coupled to the Target surface via ballistic fast electrons; however, under certain conditions, up to 60% of the absorbed RF power can be dissipated via thermalization of the fast electrons on the background plasma. Results are compared with experimental measurements. Finally, the implications of the results are discussed in the context of the upcoming MPEX device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H{sup -} ion source developments at the SNS

The U.S. Spallation Neutron Source (SNS) will require substantially higher average and pulse H{sup -} beam currents than can be produced from conventional ion sources such as the base line SNS source. H{sup -} currents of 40-50 mA (SNS operations) and 70-100 mA (power upgrade project) with a rms emittance of 0.20-0.35{pi} mm mrad and a {approx}7% duty factor will be needed. We are therefore investigating several advanced ion source concepts based on rf plasma excitation. First, the performance characteristics of an external antenna source based on an Al{sub 2}O{sub 3} plasma chamber combined with an external multicusp magnetic configuration, an elemental Cs system, and plasma gun will be discussed. Second, the first plasma measurements of a helicon-driven H{sup -} ion source will also be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Flow During RF Discharges in VASIMR

The Variable Specific Impulse Magnetoplasma Rocket (VASIMR) plasma source consists of a helical antenna, driven at frequencies of 4 to 19 MHz with powers up to 1 kW, in a magnetic field up to 3 kG. Helium is the current test gas, and future experiments with hydrogen are planned. Plasma density and temperature profiles were measured by a reciprocating Langmuir probe, and plasma flow profiles were measured with a reciprocating Mach probe. Both probes were located about 0.5 m downstream from the helical antenna. The plasma source operated in capacitive and inductive modes in addition to a helicon mode. During capacitive and inductive modes, densities were low and plasma flow was < 0.5 Cs. When the plasma operated in a helicon mode, the densities measured downstream from the source were higher [10(exp 12) / cubic cm ] and plasma flow along the magnetic field was of the order Mach 1. Details of the measurements will be shown.

Jacobson, V. T.↗

Analysis of Design Alternatives of Actively Cooled RF Window for MPEX

The Materials Plasma Exposure eXperiment (MPEX) has been designed as a linear plasma divertor simulator in order to address plasma material interaction (PMI) science for next-generation fusion devices. It will have the capability to test neutron irradiated samples with plasma fluxes of greater than 10 24 m -2 s -1 . It is expected to operate steady state for up to 10 6 s to consider PMI affects through reactor end of life. The conceptual design of MPEX was completed in 2019, with preliminary design having begun in 2020. The plasma source for MPEX is a helicon antenna, where the energized helical antenna sits outside of the vacuum in order to minimize impurities in the plasma. It is expected to receive up to 200 kW of continuous power, and so the antenna and the window must be actively cooled. The water-cooled copper antenna has been operated at full power on the Proto-MPEX device (which is a test facility to demonstrate the plasma source and heating systems). The water-cooled window, however, is a novel component that must meet numerous competing requirements. It requires a low dielectric loss to allow the Radio Frequency (RF) power to create the plasma within the vacuum boundary. It must be structurally robust to handle the significant heat flux from the plasma and any heat from dielectric coupling. It must be compatible with the coolant (preferably water). It requires a vacuum seal that minimizes impurities into the plasma and does not compromise the structural integrity of the window. Two window designs have been tested. Results from these tests, where temperatures are measured and heat fluxes inferred from infrared camera data, have been correlated with thermal-structural simulations. When these simulations are extrapolated to the full power steady-state heat fluxes that are expected in MPEX, the designs do not appear to have the necessary structural robustness. This study explores design alternatives for the MPEX helicon antenna window, presents analysis results for several of the alternatives, and shows a viable solution that satisfies the requirements for MPEX operation.

Tipton Jr, Joseph↗

H{sup -} Ion Source Development for the LANSCE Accelerator Systems

Employment of H- ion sources for the LANSCE accelerator systems goes back about 20 years, to the construction of the Proton Storage Ring (PSR). The standard ion source consists of a filament driven multi-cusp discharge vessel with a biased converter electrode for negative-ion production and an 80-kV extraction system feeding into a 670-kV electrostatic pre-accelerator. The source typically delivers 18 mA pulsed beam current into the pre-accelerator column and reaches up to 35 days between services at 60 Hz pulse repetition rate. Recent development efforts with this source have been dedicated to improved filament material, improved cesium oven geometry and operating the source at elevated temperatures. A second line of development focuses on filament-less devices driven by a helicon discharge. Performance data obtained with the standard source as well as key results for the helicon experiments are given in this paper; the helicon work is discussed in a separate paper in much greater detail.

43 PARTICLE ACCELERATORS↗