Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heavy ion testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Decline in Radiation Hardened Microcircuit Infrastructure

Two areas of radiation hardened microcircuit infrastructure will be discussed: 1) The availability and performance of radiation hardened microcircuits, and, and 2) The access to radiation test facilities primarily for proton single event effects (SEE) testing. Other areas not discussed, but are a concern include: The challenge for maintaining radiation effects tool access for assurance purposes, and, the access to radiation test facilities primarily for heavy ion single event effects (SEE) testing. Status and implications will be discussed for each area.

performance of radiation hardened microcircuits↗

Towards a Qualification Data Set: Expanded SEE Data on the P2020 Processor

Earlier P2020 SEE data are compared and expanded to a recent die revision, significantly increasing samples tested by protons by five devices, and by heavy ions by five devices. Earlier tested SEE types are found to be fairly similar in register, L1 cache, L2 cache, and CPU crashes. New test methods give SEE performance for the flash memory controller, watchdog circuit, and a built-in Ethernet port on the P2020 processor. Results from heavy ion and proton tests are presented, with data separated over a large number of specific error types and test programs.

Vartanian, Sargeh↗

ETROC2 as the Final Version for CMS MTD Endcap Timing Layer (ETL) Upgrade

The ETROC2 is the first full-size full-functionality prototype design fully compatible with the final chip specifications for CMS ETL. The ETROC2 chips have been extensively tested and the results have been presented at IEEE NSS MIC RTSD 2024. We will present here new results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with single pixel TWC applied to all pixels, the final SEU testing results using both heavy ion and proton beam, more beam test studies including different sensors and irradiated sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tie Hui [Fermilab] (ORCID:0009000765225605)↗

Radiation Susceptibility Assessment of Off the Shelf (OTS) Hardware

The reduction in budgets, shortening of schedules and necessity of flying near state of the art technology have forced projects and designers to utilize not only modern, non-space rated EEE parts but also OTS boards, subassemblies and systems. New instrumentation, communications, portable computers and navigation systems for the International Space Station, Space Shuttle, and Crew Return Vehicle are examples of the realization of this paradigm change at the Johnson Space Center. Because of this change, there has been a shift in the radiation assessment methodology from individual part testing using low energy heavy ions to board and box level testing using high-energy particle beams. Highlights of several years of board and system level testing are presented along with lessons learned, present areas of concern, insights into test costs, and future challenges.

Culpepper, William X.↗

Test report for single event effects of the 80386DX microprocessor

The Jet Propulsion Laboratory Section 514 Single Event Effects (SEE) Testing and Analysis Group has performed a series of SEE tests of certain strategic registers of Intel's 80386DX CHMOS 4 microprocessor. Following a summary of the test techniques and hardware used to gather the data, we present the SEE heavy ion and proton test results. We also describe the registers tested, along with a system impact analysis should these registers experience a single event upset.

Watson, R. Kevin↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

The RBE-LET relationship for rodent intestinal crypt cell survival, testes weight loss, and multicellular spheroid cell survival after heavy-ion irradiation

This report presents data for survival of mouse intestinal crypt cells, mouse testes weight loss as an indicator of survival of spermatogonial stem cells, and survival of rat 9L spheroid cells after irradiation in the plateau region of unmodified particle beams ranging in mass from 4He to 139La. The LET values range from 1.6 to 953 keV/microns. These studies examine the RBE-LET relationship for two normal tissues and for an in vitro tissue model, multicellular spheroids. When the RBE values are plotted as a function of LET, the resulting curve is characterized by a region in which RBE increases with LET, a peak RBE at an LET value of 100 keV/microns, and a region of decreasing RBE at LETs greater than 100 keV/microns. Inactivation cross sections (sigma) for these three biological systems have been calculated from the exponential terminal slope of the dose-response relationship for each ion. For this determination the dose is expressed as particle fluence and the parameter sigma indicates effect per particle. A plot of sigma versus LET shows that the curve for testes weight loss is shifted to the left, indicating greater radiosensitivity at lower LETs than for crypt cell and spheroid cell survival. The curves for cross section versus LET for all three model systems show similar characteristics with a relatively linear portion below 100 keV/microns and a region of lessened slope in the LET range above 100 keV/microns for testes and spheroids. The data indicate that the effectiveness per particle increases as a function of LET and, to a limited extent, Z, at LET values greater than 100 keV/microns. Previously published results for spread Bragg peaks are also summarized, and they suggest that RBE is dependent on both the LET and the Z of the particle.

Non-NASA Center↗

Radiation effects assessment of MRAM devices

The Magneto-resistive Random Access Memory (MRAM) from Freescale Semiconductor, MR2A16A, was subjected to heavy ion single event testing. Test results show that this device is sensitive to Single Event Latchup (SEL). The sensitivity of the MRAM was attributed to the complementary metal oxide semiconductor (CMOS) process in which the active portion of this device is constructed. Therefore, the device must be used with caution and may require mitigation techniques if used in a space environment. There was no indication that the MRAM technology itself, the memory element construction, is subject to damage from heavy ions.

McClure, Steve↗

Model emulation and closure tests for (3+1)D relativistic heavy-ion collisions

In nuclear and particle physics, reconciling sophisticated simulations with experimental data is vital for understanding complex systems like the Quark Gluon Plasma (QGP) generated in heavy ion collisions. However, computational demands pose challenges, motivating using Gaussian Process emulators for efficient parameter extraction via Bayesian calibration. We conduct a comparative analysis of Gaussian Process emulators in heavy-ion physics to identify the most adept emulator for parameter extraction with minimal uncertainty. Furthermore, our study contributes to advancing computational techniques in heavy-ion physics, enhancing our ability to interpret experimental data and understand QGP properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extending deterministic transport capabilities for very-high and ultra-high energy electron beams

Focused Very-High Energy Electron (VHEE, 50–300 MeV) and Ultra-High Energy Electron (UHEE, > 300 MeV) beams can accurately target both large and deeply seated human tumors with high sparing properties, while avoiding the spatial requirements and cost of proton and heavy ion facilities. Advanced testing phases are underway at the CLEAR facilities at CERN (Switzerland), NLCTA at Stanford (USA), and SPARC at INFN (Italy), aiming to accelerate the transition to clinical application. Currently, Monte Carlo (MC) transport is the sole paradigm supporting preclinical trials and imminent clinical deployment. In this paper, we propose an alternative: the first extension of the nuclear-reactor deterministic chain Njoy-Dragon for VHEE and UHEE applications. We have extended the Boltzmann-Fokker-Planck (BFP) multigroup formalism and validated it using standard radio-oncology benchmarks, complex assemblies with a wide range of atomic numbers, and comprehensive irradiation of the entire periodic table. We report that 99% of water voxels exhibit a BFP-MC deviation below 2% for electron energies under 1.5 GeV. Additionally, we demonstrate that at least 97% of voxels of bone, lung, adipose tissue, muscle, soft tissue, tumor, steel, and aluminum meet the same criterion between 50 MeV and 1.5 GeV. For water, the thorax, and the breast intra-operative benchmark, typical average BFP-MC deviations of 0.3% and 0.4% were observed at 300 MeV and 1 GeV, respectively. By irradiating the entire periodic table, we observed similar performance between lithium (Z = 3) and cerium (Z = 58). Deficiencies observed between praseodymium (Z = 59) and einsteinium (Z = 99) have been reported, analyzed, and quantified, offering critical insights for the ongoing development of the Evaluated Nuclear Data File mode in NJOY.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends In Susceptibility To Single-Event Upset

Report provides nearly comprehensive body of data on single-event upsets due to irradiation by heavy ions. Combines new test data and previously published data from governmental and industrial laboratories. Clear trends emerge from data useful in predicting future performances of devices.

Nichols, Donald K.↗

Micron MT29F1T08CMHBBJ4 1Tb NAND Flash Memory Single Event Effect Characterization Test Report

The purpose of this testing is to characterize the Single-Event Effect (SEE) response of the Micron MT29F1T08CMHBBJ4 3D NAND Flash memory. The MT29F1T08CMHBBJ4 is a 1Tb NAND Flash memory, consisting of a four-die stack of 256Gb MLC dice packaged in a 132-ball VBGA package. All data presented is the result of testing only the top die (256Gb) of the package. Testing was performed at two heavy-ion cyclotron facilities with an identical test setup, over the course of four test trips from 2017-2019.

Single Event Effect (SEE)↗