Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Heat-requirements for Ice Protection of a Cyclically Gas-heated, 36 Degree Swept Airfoil with Partial-span Leading-edge Slat

Heating requirements for satisfactory cyclic de-icing over a wide range of icing and operating conditions have been determined for a gas-heated, 36deg swept airfoil of 6.9-foot chord with a partial-span leading-edge slat. Comparisons of heating requirements and effectiveness were made between the slatted and unslatted portions of the airfoil. Studies were also made comparing cyclic de-icing with continuous anti-icing, and cycll.cde-icing systems with and without leading-edge ice-free parting strips. De-icing heat requirements were approximately the same with either heated or unheated parting strips because of the aerodynamic effects of the 36deg sweep angle and the spanwise saw-tooth profile of leading-edge glaze-ice deposits. Cyclic de-icing heat-source requirements were found to be one-fourth or less of the heat requirements for complete anti-icing. The primary factors that affected the performance of the cyclic de-icing heating system were ambient air temperature, heat distribution, and thermal lag.

Gray, Vernon H↗

Heat Transfer Over the Circumference of a Heated Cylinder in Transverse Flow

A method for recording the local heat-transfer coefficients on bodies in flow was developed. The cylinder surface was kept at constant temperature by the condensation of vapor except for a narrow strip which is heated separately to the same temperature by electricity. The heat-transfer coefficient at each point was determined from the electric heat output and the temperature increase. The distribution of the heat transfer along the circumference of cylinders was recorded over a range of Reynolds numbers of from 5000 to 426,000. The pressure distribution was measured at the same time. At Reynolds numbers up to around 100,000 high maximums of the heat transfer occurred in the forward stagnation point at and on the rear side at 180C, while at around 80 the heat-transfer coefficient on both sides of the cylinder behind the forward stagnation point manifested distinct minimums. Two other maximums occurred at around 115 C behind the forward stagnation point between 170,000 and 426,000. At 426,000 the heat transfer at the location of those maximums was almost twice as great as in the forward stagnation point, and the rear half of the cylinder diffused about 60 percent of the entire heat, The tests are compared with the results of other experimental and theoretical investigations.

Schmidt, Ernst↗

Shallow and Deep Latent Heating Modes Over Tropical Oceans Observed with TRMM PR Spectral Latent Heating Data

The global hydrological cycle is central to the Earth's climate system, with rainfall and the physics of its formation acting as the key links in the cycle. Two-thirds of global rainfall occurs in the Tropics. Associated with this rainfall is a vast amount of heat, which is known as latent heat. It arises mainly due to the phase change of water vapor condensing into liquid droplets; three-fourths of the total heat energy available to the Earth's atmosphere comes from tropical rainfall. In addition, fresh water provided by tropical rainfall and its variability exerts a large impact upon the structure and motions of the upper ocean layer. Three-dimensional distributions of latent heating estimated from Tropical Rainfall Measuring Mission Precipitation Radar (TRMM PR)utilizing the Spectral Latent Heating (SLH) algorithm are analyzed. Mass-weighted and vertically integrated latent heating averaged over the tropical oceans is estimated as approx.72.6 J/s (approx.2.51 mm/day), and that over tropical land is approx.73.7 J/s (approx.2.55 mm/day), for 30degN-30degS. It is shown that non-drizzle precipitation over tropical and subtropical oceans consists of two dominant modes of rainfall systems, deep systems and congestus. A rough estimate of shallow mode contribution against the total heating is about 46.7 % for the average tropical oceans, which is substantially larger than 23.7 % over tropical land. While cumulus congestus heating linearly correlates with the SST, deep mode is dynamically bounded by large-scale subsidence. It is notable that substantial amount of rain, as large as 2.38 mm day-1 in average, is brought from congestus clouds under the large-scale subsiding circulation. It is also notable that even in the region with SST warmer than 28 oC, large-scale subsidence effectively suppresses the deep convection, remaining the heating by congestus clouds. Our results support that the entrainment of mid-to-lower-tropospheric dry air, which accompanies the large-scale subsidence is the major factor suppressing the deep convection. Therefore, representation of the realistic entrainment is very important for proper reproduction of precipitation distribution and resultant large-scale circulation.

Takayabu, Yukari N.↗

Heat Rejection from a Variable Conductance Heat Pipe Radiator Panel

A titanium-water heat pipe radiator having an innovative proprietary evaporator configuration was evaluated in a large vacuum chamber equipped with liquid nitrogen cooled cold walls. The radiator was manufactured by Advanced Cooling Technologies, Inc. (ACT), Lancaster, PA, and delivered as part of a Small Business Innovative Research effort. The radiator panel consisted of five titanium-water heat pipes operating as thermosyphons, sandwiched between two polymer matrix composite face sheets. The five variable conductance heat pipes were purposely charged with a small amount of non-condensable gas to control heat flow through the condenser. Heat rejection was evaluated over a wide range of inlet water temperature and flow conditions, and heat rejection was calculated in real-time utilizing a data acquisition system programmed with the Stefan-Boltzmann equation. Thermography through an infra-red transparent window identified heat flow across the panel. Under nominal operation, a maximum heat rejection value of over 2200 Watts was identified. The thermal vacuum evaluation of heat rejection provided critical information on understanding the radiator s performance, and in steady state and transient scenarios provided useful information for validating current thermal models in support of the Fission Power Systems Project.

Jaworske, D. A.↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and validation of non-axisymmetric heat flux simulations with 3D fields using the HEAT code

A new comprehensive module to simulate heat fluxes from three-dimensional (3D) magnetic fields has been implemented in the HEAT code. Especially compact tokamaks like SPARC require tools to predict and manage large heat fluxes. Existing release versions of HEAT can only simulate axisymmetric heat flux on 3D plasma facing components. The new module uses an M3D-C1 perturbed equilibrium and the MAFOT code to trace field lines of the perturbed 3D magnetic field. Heat flux is then assigned to the resulting footprints via a 3D layer model. The model distinguishes between the scrape-off layer, the magnetic lobes and the private flux region, and employs only 0D parameters like the layer width, diffusive spread and the last closed flux surface position in the perturbed edge to generate a heat flux profile. The magnitude is normalized to the total input power. Resulting heat flux simulations are compared and validated against infrared measurements in the DIII-D tokamak with applied 3D fields; good agreement is found for several cases. The new module can now be applied to the SPARC tokamak; a preliminary result for applied rotating 3D fields is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Anisotropic Porosity on Heat Transfer and Off-Gassing during Biomass Pyrolysis

The pore structure of biogenic materials imbues the ability to deliver water and nutrients through a plant from root to leaf. This anisotropic pore granularity can also play a significant role in processes such as biomass pyrolysis that are used to convert these materials into useful products like heat, fuel, and chemicals. Evolutions in modeling of biomass pyrolysis as well as imaging of pore structures allow for further insights into the concerted physics of phase change-induced off-gassing, heat transfer, and chemical reactions. In this work, we report a biomass single particle model which incorporates these physics to explore the impact of implementing anisotropic permeability and diffusivity on the conversion time and yields predicted for pyrolysis of oak and pine particles. Simulation results showed that anisotropic permeability impacts predicted conversion time more than 2 times when the Biot number is above 0.1 and pyrolysis numbers (Py 1 , Py 2 ) are less than 20. Pore structure significantly impacts predicted pyrolytic conversion time (>8 times) when the Biot number is above 1 and the pyrolysis number is below 1, i.e., the “conduction controlled” regime. Therefore, these nondimensional numbers reflect that when internal heat conduction limits pyrolysis performance, internal pyrolysis off-gassing further retards effective heat transfer rates as a closely coupled phenomenon. Overall, this study highlights physically meaningful opportunities to improve particle-scale pyrolysis modeling and experimental validation relevant to a variety of feedstock identities and preparations, guiding the future design of pyrolyzers for efficient biomass conversion.

09 BIOMASS FUELS↗

Analysing the effects of heating and gas puffing in Proto-MPEX helicon and auxiliary heated plasmas

The Material Plasma Exposure Experiment (MPEX) is being constructed at Oak Ridge National Laboratory to investigate critical fusion reactor issues, such as plasma–material interactions (PMIs) under reactor-relevant conditions and time scales. The linear device Proto-MPEX was used as a test bed to address anticipated research and development issues associated with heating scenarios and establish the physics basis for MPEX. The SOLPS-ITER code suite has been applied to understand plasma and neutral transport in Proto-MPEX and to increase confidence in predictive simulations for MPEX. Coupling between COMSOL and SOLPS is performed to implement a 2D electron heating profile of the helicon source. The simulations show reasonable agreement with the experimental data for plasma with helicon and auxiliary electron cyclotron heating (ECH). Both Bohm and constant diffusion (D$_\perp$: 0.5 m 2 s –1 and $\chi_\perp$: 1 m 2 s –1 ) simulations show similar levels of agreement with respect to the sparse experimental data available, assuming a few per cent impurity concentration. ECH significantly increases the target electron temperature, however, the target electron density is reduced compared to helicon-only heated plasmas due to an increase in flow velocity and radial losses. The simulations show that further increasing the ECH power results in an increase in the target electron density due to increased recycling flux and ionization. The results indicate that ECH significantly enhances the target heat flux, with ECH power of 50 kW increasing the target heat flux from 0.4 to 17 MW m –2 . It is found that a small amount of gas puffing (GP) near the target plate can further increase the target heat fluxes at the higher ECH power cases, but the target heat flux is reduced at higher GP conditions due to a significant reduction in electron temperature via radiation. ECH and GP scenarios can generate a higher target flux, facilitating improved PMI studies with more reactor-relevant plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A software package for plasma facing component analysis and design: the Heat flux Engineering Analysis Toolkit (HEAT)

The engineering limits of plasma facing components (PFCs) constrain the allowable operational space of tokamaks. Poorly managed heat fluxes that push the PFCs beyond their limits not only degrade core plasma performance via elevated impurities, but can also result in PFC failure due to thermal stresses or melting. Simple axisymmetric assumptions fail to capture the complex interaction between 3D PFC geometry and 2D or 3D plasmas. This results in fusion systems that must either operate with increased risk or reduce PFC loads, potentially through lower core plasma performance, to maintain a nominal safety factor. High precision 3D heat flux predictions are necessary to accurately ascertain the state of a PFC given the evolution of the magnetic equilibrium. A new code, the Heat flux Engineering Analysis Toolkit (HEAT), has been developed to provide high precision 3D predictions and analysis for PFCs. HEAT couples many otherwise disparate computational tools together into a single open source python package. Magnetic equilibrium, engineering CAD, finite volume solvers, scrape off layer plasma physics, visualization, high performace computing, and more, are connected in a single web-based user interface. Linux users may use HEAT without any software prerequisites via an appImage. This manuscript introduces HEAT, discusses the software architecture, presents first HEAT results, and outlines physics modules in development.

divertor physics↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Local heat transfer measurement in a volumetrically heated TPMS lattice using distributed optical fiber thermal sensing

As additive manufacturing continues to reduce design constraints on heat exchange geometries, methods for high-fidelity local heat transfer measurements in nonconventional channel geometries are critical to their continued development. This study presents a novel method for measuring local heat transfer performance in volumetrically heated lattices using a distributed optical fiber temperature sensor. A diamond-type triply periodic minimal surface (TPMS) lattice, 3D-printed from a conductive polymer, was Joule heated while it was convectively cooled with air. Temperature measurements were taken at the solid–fluid interface across 14 internal locations using a single optical fiber over the Reynolds number range 800–2750. The TPMS lattice achieved up to 312% higher heat transfer coefficients compared to developing flow in a straight tube. A Nusselt number correlation was developed for the diamond TPMS, which showed good agreement with data collected for comparable geometries available in literature. In conclusion, this study presents a robust and new method for experimental measurement of the heat transfer coefficient in complex geometries and helps to understand and quantify the exceptional performance of TPMS heat transfer geometries.

TPMS↗

Numerical simulations of membrane distillation systems with actively heated membranes

Membrane distillation (MD) is a thermal desalination process that is gaining attention for treating hypersaline brines. One recent approach uses composite membranes with a thermally conductive layer that delivers heat to the membrane–feed interface, where it drives evaporation. Though this increases single-pass recovery, it comes with the challenge of promoting lateral heat conduction through the thin membrane. Herein, we develop a 3D, computational fluid dynamics (CFD) model that simulates conjugate heat, mass, and momentum transport in the feed channel and composite membrane. We then use the CFD to verify a simpler numerical model that approximates the feed velocity field analytically. We validate the numerical model experimentally, and use it to investigate the impacts of the conductive layer thickness, feed channel geometry, and operating conditions on temperature and concentration polarization, permeate production, and specific energy consumption. Overall, we find that lateral heating increases permeate production at the expense of increased concentration polarization. In extreme cases, the concentration increases more than four-fold along the membrane surface. Furthermore, we show however, that the feed flow rate and conductive layer thickness can be tailored to mitigate concentration polarization, for only a small reduction in permeate production.

42 ENGINEERING↗