Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat leak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Economic optimization of the energy transport component of a large distributed solar power plant

A solar thermal power plant with a field of collectors, each locally heating some transport fluid, requires a pipe network system for eventual delivery of energy power generation equipment. For a given collector distribution and pipe network geometry, a technique is herein developed which manipulates basic cost information and physical data in order to design an energy transport system consistent with minimized cost constrained by a calculated technical performance. For a given transport fluid and collector conditions, the method determines the network pipe diameter and pipe thickness distribution and also insulation thickness distribution associated with minimum system cost; these relative distributions are unique. Transport losses, including pump work and heat leak, are calculated operating expenses and impact the total system cost. The minimum cost system is readily selected. The technique is demonstrated on six candidate transport fluids to emphasize which parameters dominate the system cost and to provide basic decision data. Three different power plant output sizes are evaluated in each case to determine severity of diseconomy of scale.

Turner, R. H.↗

Fabrication and test of a variable conductance heat pipe

A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.

Lehtinen, A. M.↗

Performance sensitivity analysis of Department of Energy-Chrysler upgraded automotive gas turbine engine, S/N 5-4

The performance sensitivity of a two-shaft automotive gas turbine engine to changes in component performance and cycle operating parameters was examined. Sensitivities were determined for changes in turbomachinery efficiency, compressor inlet temperature, power turbine discharge temperature, regenerator effectiveness, regenerator pressure drop, and several gas flow and heat leaks. Compressor efficiency was found to have the greatest effect on system performance.

Johnsen, R. L.↗

Cryogenic container compound suspension strap

A support strap for use in a cryogenic storage vessel for supporting the inner shell from the outer shell with a minimum heat leak is presented. The compound suspension strap is made from a unidirectional fiberglass epoxy composite material with an ultimate tensile strength and fatigue strength which are approximately doubled when the material is cooled to a cryogenic temperature.

Vorreiter, J. W.↗

A liquid hydrogen experiment as a Shuttle payload

The paper describes the cryogenic fluid management experiment (CFME) as a Shuttle payload. The experiment includes a liquid hydrogen tank containing a fine-mesh screen acquisition device, and a thermal control system consisting of a thermodynamic vent system to intercept heat leak to the hydrogen tank and control tank pressure. Engineering data obtained will be used to establish design criteria for subcritical cryogenic storage and supply tankage.

Eberhardt, R. N.↗

Conceptual design and analysis of orbital cryogenic liquid storage and supply systems

A wide variety of orbital cryogenic liquid storage and supply systems are defined in NASA and DOD long-range plans. These systems include small cooling applications, large chemical and electrical orbit transfer vehicles and supply tankers. All have the common requirements of low-g fluid management to accomplish gas-free liquid expulsion and efficient thermal control to manage heat leak and tank pressure. A preliminary design study was performed to evaluate tanks ranging from 0.6 to 37.4 cu m (22 to 1320 cu ft). Liquids of interest were hydrogen, oxygen, methane, argon and helium. Conceptual designs were generated for each tank system and fluid dynamic, thermal and structural analyses were performed for Shuttle compatible operations. Design trades considered the paradox of conservative support structure and minimum thermal input. Orbital performance and weight data were developed, and a technology evaluation was completed.

Eberhardt, R. N.↗

Shuttle compatible cryogenic liquid storage and supply systems

A detailed introduction is given to a wide variety of orbital cryogenic liquid storage and supply systems required for future vehicles by NASA and DOD. The systems include small cooling applications, large chemical and electrical orbit transfer vehicles and resupply tankers, and all have the common requirements of low-g fluid management for the accomplishment of gas-free liquid expulsion, and efficient thermal control in order to manage heat leak and tank pressure. The present study considers hydrogen, oxygen, methane, argon and helium tanks ranging from 0.6 to 37.4 cu m. Conceptual designs were generated for each tank system, and fluid dynamic, structural and thermal analyses were performed in view of Shuttle requirements.

Eberhardt, R. N.↗

Cryogenic fluid management experiment

The cryogenic fluid management experiment (CFME), designed to characterize subcritical liquid hydrogen storage and expulsion in the low-q space environment, is discussed. The experiment utilizes a fine mesh screen fluid management device to accomplish gas-free liquid expulsion and a thermodynamic vent system to intercept heat leak and control tank pressure. The experiment design evolved from a single flight prototype to provision for a multimission (up to 7) capability. A detailed design of the CFME, a dynamic test article, and dedicated ground support equipment were generated. All materials and parts were identified, and components were selected and specifications prepared. Long lead titanium pressurant spheres and the flight tape recorder and ground reproduce unit were procured. Experiment integration with the shuttle orbiter, Spacelab, and KSC ground operations was coordinated with the appropriate NASA centers, and experiment interfaces were defined. Phase 1 ground and flight safety reviews were conducted. Costs were estimated for fabrication and assembly of the CFME, which will become the storage and supply tank for a cryogenic fluid management facility to investigate fluid management in space.

Eberhardt, R. N.↗

Attitude control and drag compensation propulsion system for Gravity Probe-B spacecraft

An on board propulsion system for attitude control and drag compensation is presented which uses helium boiloff gas from an experiment package dewar as propellant. This boiloff gas would normally be vented nonpropulsively. Use of a small allowable temperature range in the dewar is exploited to store helium and accommodate incompatibilities in dewar heat leak and thruster demand flow over periods of more than one orbit. A relatively detailed thermodynamics analysis of the two phase helium dewar and simulation of pressure loss through the helium distribution system is included.

Blount, D. H.↗

Passive Orbital Disconnect Strut (PODS 3), structural and thermal test program

A test program is undertaken to verify that the lifetime of a shuttle launchable dewar can be increased by using passive orbital disconnect struts (PODS). A detailed design is performed on the cold end (PODS-III) portion of the strut. Structural analysis of the thin-wall fiberglass tube allows selection of the optimum winding angle and tube dimensions. Structural tests on the thin-wall fiberglass tube measure both the tension and compression modulus at ambient and LN2 temperatures, the radial deflection versus side load, and the ultimate compression strength of the tube at LN2 temperature. The thermal expansion of the fiberglass tube plus Invar is also measured down to 78 K. The axial gap at the wedge portion of the stem is set based on these data. The PODS-III test article parts are fabricated and assembled using a detailed assembly procedure. The thermal conductants in the orbital configuration was measured for body temperatures between 5 and 40 K. This temperature range covers the predicted ground hold and orbit temperatures for vapor-cooled supports. The test results are then compared with heat leak values predicted before the test began. Side load, axial compression load, and tension load tests conclude the test program.

Parmley, R. T.↗

Optimation of cooled shields in insulations

A method to optimize the location, temperature, and heat dissipation rate of each cooled shield inside an insulation layer was developed. The method is based on the minimization of the entropy production rate which is proportional to the heat leak across the insulation. It is shown that the maximum number of shields to be used in most practical applications is three. However, cooled shields are useful only at low values of the overall, cold wall to hot wall absolute temperature ratio. The performance of the insulation system is relatively insensitive to deviations from the optimum values of the temperature and location of the cooling shields. Design curves for rapid estimates of the locations and temperatures of cooling shields in various types of insulations, and an equation for calculating the cooling loads for the shields are presented.

Chato, J. C.↗

Magnetic suspension and balance system study

A compact design for a superconducting magnetic suspension and balance system is developed for a 8 ft. x 8 ft. transonic wind tunnel. The main features of the design are: a compact superconducting solenoid in the suspended airplane model; permanent magnet wings; one common liquid helium dewar for all superconducting coils; efficient new race track coils for roll torques; use of established 11 kA cryostable AC conductor; acceptable AC losses during 10 Hz control even with all steel structure; and a 560 liter/hour helium liquefier. Considerable design simplicity, reduced magnet weights, and reduced heat leak results from using one common dewar which eliminates most heavy steel structure between coils and the suspended model. Operational availability is thought to approach 100% for such magnet systems. The weight and cost of the magnet system is approximately one-third that of previous less compact designs.

Boom, R. W.↗

Cryogenic Propellant Scavenging

A detailed description of a computer model that has been developed for assessing the feasibility of low g cryogen propellant scavenging from the space shuttle External Tank (ET) is given. Either pump-assisted or pressure-induced propellant transfer may be selected. The program will accept a wide range of input variables, including the fuel to be transferred (LOX or LH2), heat leaks, tank temperatures, and piping and equipment specifications. The model has been parametrically analyzed to determine initial design specification for the system.

Louie, B.↗

Transferring superfluid helium in space

A simple thermodynamic model of a transfer system for resupplying liquid helium in space is presented, with application to NASA projects including the Space Infrared Telescope Facility, the Large Deployable Reflector, and the Hubble Space Telescope. The relations between different thermodynamic regimes that can be expected in the transfer line are used to study the relative efficiencies of various possible transfer techniques. Low heat leak into the transfer line, particularly at point sources such as the coupling, is necesssary for efficient transfer of liquid helium, and proper selection of supply tank temperature is important during helium resupply.

Kittel, Peter↗

Multitemperature Cryogenic Radiative Cooler

Multiple radiator stages separated by V-groove shields protect main cooler from parasitic heat radiation and offer usable cooling themselves. Proposed cryogenic radiative cooler achieves lower temperatures previously possible with passive radiators in space. Provides useful cooling power at several temperatures instead of one. Cold-radiator stage protected by multiple shield assemblies intercepting radiation heat leaks from warmer supporting structure and redirects it out to space. Each shield assembly has effective cooling capacity enabling it to cool optical filter.

Bard, Steven↗

Stability and refrigeration of magnet cryosystems near 1.8 K using the thermomechanical effect

Magnet cryosystem options utilizing the thermomechanical effect of He II and the mechano-caloric effect for refrigeration (referred to as vortex refrigeration) are examined. The performance of the existing He II magnet refrigeration system is briefly reviewed, with attention given to superleak properties, vortex shedding, heat input, and thermodynamic cycle. It is concluded that the possibilities of magnet heat leak use for energetics and stability improvements are promising when He II is selected as magnet coolant.

Frederking, T. H. K.↗

Superfluid Helium Orbital Resupply Coupling

The resupply of superfluid helium to satellites and other space-based experiment packages can increase the useful longevity of these devices far beyond their present life expectancies which are many times determined by the supply of helium coolant. The transfer of superfluid helium to spacecraft in space will require a reusable coupling that functions at 1.8 Kelvin with little heat leak and low pressure drop. Moog has designed the Helium Resupply Coupling to meet these operational requirements. Initially, the coupling manual mode operation will be demonstrated on orbit by an EVA crew member during the Space Shuttle borne Superfluid Helium On-Orbit Transfer (SHOOT) experiment. The ultimate application will use robotic (automatic) coupling operation to which the present design readily adapts. The utilization of Moog's exclusive Rotary Shut-Off (RSO) technology in the development of the Superfluid Helium Resupply Coupling is described. The coupling not only performs the function of a flow control valve and disconnect but also provides adequate safety features for a shuttle launched man-rated payload. In addition, the coupling incorporates the necessary features to provide the high thermal isolation of the internal flow path from the external environment.

Ryder, M. O.↗

A pressure control analysis of cryogenic storage systems

Self-pressurization of cryogenic storage tanks due to heat leak through the thermal protection system is examined along with the performance of various pressure control technologies for application in microgravity environments. Methods of pressure control such as fluid mixing, passive thermodynamic venting, and active thermodynamic venting are analyzed using the homogeneous thermodynamic model. Simplified equations suggested may be used to characterize the performance of various pressure control systems and to design space experiments.

Lin, C.-S.↗