Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “half-life”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Radionuclide-specific Parameters Dataset

The radionuclide-specific parameters dataset is searchable for radiological information for multiple isotopes simultaneously. After selecting radionuclides of interest and the desired parameters, the RAIS will generate a table containing the values, chosen according to an established hierarchy. Results can be downloaded in Excel format. 50 parameters are available, including atomic number, soil to animal transfer coefficients, plant uptake coefficients, half-life, specific activity, and water solubility. Seven primary sources are used to populate the dataset of radiological-specific parameters. These values should be used in cancer risk assessments for the calculation of preliminary remediation goals (PRGs), hazard characterization, and transport modeling. Users can select up to 1000 radionuclides per query. The dataset supports environmental risk assessments, regulatory decision-making, and environmental planning with tools for benchmarking against risk-based standards. This structured approach ensures a robust evaluation of environmental risks tailored to regulatory needs.

Manning, Karessa [Oak Ridge National Laboratory (O↗

Establishing Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory

Background: Promising developments in Pb-212 radiopharmaceutical therapies have increased demand for Pb-203 diagnostic agents. Building on previous work from various isotope production facilities, this study optimized Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory (BNL). The additional supply of Pb-203 may help meet growing preclinical and clinical demands. Results: Two Tl targets were irradiated at the Brookhaven Linac Isotope Producer facility with 30 ± 1 MeV protons, measured using previously published cross section data. Distribution coefficients for Pb Resin in acetate media were investigated for both Na + and K + cations, where potassium acetate was ~ 4 times more effective at stripping Pb from the Pb Resin. The Tl electrodeposition was optimized to deposit 350 mg of Tl (~ 60 mg/cm 2 ) on Au backing in under 6 h. The proposed separation process was completed in < 1.5 h and achieved > 98% and 92 ± 3% recovery of Tl and Pb, respectively, with an overall Tl-Pb separation factor of 6 × 10 5 . The experimentally measured half-life of Pb-203 was 52.4 ± 0.7 h, agreeing with 51.93 ± 0.02 h reported by the National Nuclear Data Center. The radioisotopic purity of the Pb fraction at 24 h post end of bombardment (EOB) from a 24 h irradiation was 66% Pb-203, 28% Pb-201, and 6% Pb-200. Following chemical separation, the Pb-203 produced in this work (21 MBq Pb-203 EOB) achieved apparent molar activities of 10 ± 5 and 0.9 ± 0.5 GBq/µmol for [ 203 Pb]Pb-DOTAM and [ 203 Pb]Pb-DO3A, respectively, decay corrected to EOB. Data derived from this work suggests BNL can produce > 10’s GBq Pb-203 with > 99% radiochemical and radioisotopic purity from Tl-205 for worldwide distribution. Conclusions: The production and separation of Pb-203 from natural Tl target material was successfully demonstrated at BNL. Existing methods were adapted and optimized for the facilities at BNL. Results from this work will guide future large-scale Pb-203 production opportunities at BNL for clinical applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

β- and γ-Counting for Pre-detonation Nuclear Forensics on Eu-155

Post-detonation nuclear forensics was performed at Los Alamos National Laboratory (LANL) on 155Eu, a fission product on the wing of the fission product production curve whose yield is sensitive to fission fuel and neutron energy. With a half-life of 4.753 years, 155Eu provides a longer-lived option for these measurements than other fission products with similar mass numbers. The Chemistry Division Group - Nuclear and Radiochemistry, at LANL routinely measures a suite of fission products from 235U fissions in thermal neutron flux experiments known as thermal calibration exercises, using a mixture of gas proportional β-decay counting and γ-spectrometry on HPGe detectors. The fission products of interest are reported relative to a high-yield reference fission product from the same sample to create a running average ratio specific to neutron energy and fuel type; Equation 1 below shows the ratio-of-ratios R-value measured fission products are reported in: R i x = [A( i X)/A( 99 Mo)] unknown [A( i X)/A( 99 Mo)] 235 U n,th where A denotes activity, i X is the nuclide of interest, and 235 U n,th denotes irradiations of 235 U with thermal neutrons. Measurements of unknown fission spectra are ratioed to a running-average of thermal calibration results, and the resulting R-value can be referred to as against a library of irradiation conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Wavelength Shifting Plate on the LEGEND Experiment

Majorana-type neutrinos lead to a neutrinoless double beta decay with the emission of only two electrons. (Lepton Number Violation). LEGEND experiment is proposed to search for this transition from ⁷⁶Ge to ⁷⁶Se. The goal is to reach the half-life sensitivity of about 10²⁸ years in a 5 kton٠year exposure of a detector with 1 ton of isotopic ⁷⁶Ge mass.

Bae, Wonseok↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Micro-Quantification of Helium-3 and Helium-4 in TPBAR Components

This report documents the method development for measuring helium isotopes in micrometer-sized samples of tritium producing burnable absorption rod (TPBAR) components. Helium isotopes were measured as a tracer for tritium, which decays to 3 He with a half-life of 12.33 years. Getter and cladding materials from the TPBARs were analyzed, as they are designed to trap tritium. Therefore, constraining the diffusivity of tritium through these materials is of key importance. To first establish the reliability of the noble gas mass spectrometer, a reference gas with a relative 4 He/ 3 He ratio of 1000 was pre-mixed. This standard was measured several times to ensure measurements were reproducible. Unirradiated and irradiated getter and cladding samples of TPBARs were cut into 1-100 µm 3 cubes and analyzed for 3 He and 4 He content. The unirradiated materials had helium content equal to or less than that of the measured instrument background. Irradiated cladding also had instrument background levels of helium while irradiated getters had elevated levels of 3 He, interpreted to be the decay product of tritium. No diffusion of 4 He was observed in any of these materials, however, indicating that the 3 He detected in the irradiated getter was produced in situ after tritium diffusion and decay. These findings validate this method as a way to trace tritium diffusion in reactor materials.

07 ISOTOPE AND RADIATION SOURCES↗

Incorporation of Viral RNA Elements for Increased mRNA Stability Within Mammalian Cells to Prolong Nanobody Production

The development of protein-based pharmaceuticals has taken place for years, often finding roadblocks relevant to in vitro biomanufacturing, drug delivery, and drug half-life. Industrial and national laboratory focus has now shifted to messenger RNA (mRNA)-based pharmaceuticals, as mRNA can be manufactured and delivered more easily, and can lead to direct intracellular protein production. Artificial stabilization of the naturally transient mRNA is needed to prolong protein production by recipient cells. Incorporation of viral genome elements known as exoribonuclease-resistant RNA (xrRNA) should allow for this stabilization. To evaluate the effects of xrRNA on mRNA stability, fluorescent proteins are encoded within the mRNA of interest for easier detection through immunocytochemistry, microplate reader screening, and high-content confocal microscopy. As seen with the Pfizer and Moderna COVID 19 vaccines, mRNA-based medical countermeasures can be powerful tools in service of public health and biodefense, and our work to improve mRNA stability should further enhance this promising new approach to medicine.

59 BASIC BIOLOGICAL SCIENCES↗

Comprehensive Review of 2$β$ Decay Half-Lives

The double-beta (2β)-decay is the rarest nuclear physics process, and its experimental half-lives (T 1/2 ) exceed the age of the Universe from nine to fourteen orders of magnitude. Double-beta decay was observed, and its half-life was measured in 14 parent nuclei using direct, radiochemical, and geochemical methods. The decay observables are analyzed using the Evaluated Nuclear Structure Data File (ENSDF) procedures, and the recommended T 1/2 were deduced. Using the calculated values of phase factors, the effective nuclear matrix elements were extracted and compared with available data. Thousands of theoretical and experimental works have been dedicated to these topics in the last 85 years, and we present two data sets of recommended values to encapsulate the results.

2β-decay↗

Determination of Reportable Radionuclides for Defense Waste Processing Facility (DWPF) Sludge Batch 10 (Macrobatch 12)

Savannah River National Laboratory (SRNL) was tasked with the radionuclide characterization of the Sludge Batch 10 (SB10) Tank 40 sample (HTF-40-23-24) in accordance with requirements for reporting the Waste Acceptance Product Specifications (WAPS). The Defense Waste Processing Facility (DWPF) is required to report all radionuclides with half-lives greater than ten years and which comprise greater than 0.05% of the total activity inventory for a given waste form at certain specified “index years”. DWPF complies with the requirements by considering the half-life requirement (t1/2 > 10 years) and radionuclides with concentrations greater than 0.01% of the total inventory from the approximate time of production through 1,100 years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Evaluate opportunities for monitoring the oxidation states of technetium in both organic and aqueous phases using Raman spectroscopy

An important isotope in the nuclear fuel cycle, 99 Tc is characterized by its long half-life of 2.1 × 10 5 years and its beta emission. It is generated through the fission of 235 U. As the burnup levels of nuclear waste continue to rise, the concentration of technetium in spent fuel increases, leading to a heightened interest in its quantification during the reprocessing of spent nuclear fuel. In HNO3 environments, technetium predominantly exists as TcO 4 − ; however, it tends to interfere with reducing agents, decreasing the separation efficiency for actinides. Therefore, accurate quantitative determination of technetium is critical to controlling its distribution and mitigating its negative effect on the reprocessing of spent fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutrinoless Double Beta Decay of 136 Xe and Related Nuclear Structure Studies (Final Scientific Report)

The search for neutrinoless double-beta decay (0nbb) explores new physics by directly probing the unknown mass scale and possible Majorana nature of the neutrino. The nEXO experiment, one of the two leading proposed ton-scale projects in the US, has a projected sensitivity to the 136 Xe 0nbb half-life of 10 28 years. The interpretation of possible signals in this next generation of experiments would be complicated by significant variations in theoretical calculations of the nuclear matrix elements (NMEs) of the decay, and nuclear structure measurements testing those theories can help address that uncertainty. We have 136 Xe(p,n) 136 Cs reaction at TUNL to deduce the level-scheme of states in 136 Cs through which the lowest-lying 1+ state decays. We find that over 99% of such decays will proceed through at least one isomeric state with a lifetime of order 100ns, which would enable large xenon detectors to employ a delayed-coincidence technique to search for charge-exchange processes including solar neutrino interactions. We have carried out measurements at TUNL of the 134 Xe( 3 He,n) 136 Ba and 136 Xe( 3 He,n) 138 Ba reactions to low-lying 0 + states in the residuals to probe the BCS assumption for QRPA NME calculations for the initial and final nuclei in 136 Xe 0nbb. While the analyses of these reactions is not yet complete and is ongoing, our initial results indicate tension with the BCS assumption. We have assembled a thermosyphon cooling R&D system for nEXO which has demonstrated up to 500 W of cooling in vacuum. We have developed a simple thermosyphon cooling simulation for nEXO and planned laboratory tests with the R&D system to benchmark it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Alpha Decay Chains as Thermal Power Sources: Analysis and Applications for RTGs

Radioactive sources can provide power in remote and environmentally harsh locations such as the arctic or space. The generators powered by such sources are rugged and can withstand extreme temperatures, lack of sunlight, and require no human intervention for multiple years. Radioisotopes are used in thermoelectric generators to provide power at remote sites and deep in space. Isotopes like Pu-238, Cm-244, and Am-241 are used in these generators by NASA for power in space probes and spacecrafts. These power sources deliver a steady supply of energy over extended periods of time. Alpha particles created during decay do not travel far in a material. Their kinetic energy is transferred to heat that we can then convert into energy. Unlike beta and gamma decay, the slower-moving alpha particles stop in the material, making their energy available for use. Energy from these natural decay processes provides a reliable source of power. Spontaneous fission is rare and unreliable, and unlike induced fission processes, alpha decay occurs naturally and does not require external management or ignition. The ideal properties of an isotope for use as a power source depend upon the intended use. For use in an Arctic research base over a period of several years, but less than a decade, an isotope that provides high power output over a shorter lifespan may be the most suitable option. Whereas, for deep space missions where a consistent power source for decades or perhaps more than 100 years is needed that would require a very different isotope. One with a much longer half-life that would provide consistent power throughout that time and survive in that state in for these extended periods of time. These examples represent two extreme sides in terms of time frames. By analyzing the power produced by different radioactive decay processes over time, we can evaluate the suitability of various isotope decay chains for specific uses. Some unstable isotopes undergo a series of radioactive decays, transforming into different isotopes at each step and resulting in a stable isotope. The lists of isotopes in these decay processes are known as decay chains. Some of these chains, illustrated in the figures below, are currently being investigated for use in radioisotope thermoelectric generators (RTGs) designed for a range of operational durations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation↗

Factor VIII moiety of recombinant Factor VIII Fc fusion protein impacts Fc effector function and CD16 + NK cell activation

Recombinant Factor VIII-Fc fusion protein (rFVIIIFc) is an enhanced half-life therapeutic protein product used for the management of hemophilia A. Recent studies have demonstrated that rFVIIIFc interacts with Fc gamma receptors (FcγR) resulting in the activation or inhibition of various FcγR-expressing immune cells. We previously demonstrated that rFVIIIFc, unlike recombinant Factor IX-Fc (rFIXFc), activates natural killer (NK) cells via Fc-mediated interactions with FcγRIIIA (CD16). Additionally, we showed that rFVIIIFc activated CD16 + NK cells to lyse a FVIII-specific B cell clone. Here, we used human NK cell lines and primary NK cells enriched from peripheral blood leukocytes to study the role of the FVIII moiety in rFVIIIFc-mediated NK cell activation. Following overnight incubation of NK cells with rFVIIIFc, cellular activation was assessed by measuring secretion of the inflammatory cytokine IFNγ by ELISA or by cellular degranulation. We show that anti-FVIII, anti-Fc, and anti-CD16 all inhibited indicating that these molecules were involved in rFVIIIFc-mediated NK cell activation. To define which domains of FVIII were involved, we used antibodies that are FVIII domain-specific and demonstrated that blocking FVIII C1 or C2 domain-mediated membrane binding potently inhibited rFVIIIFc-mediated CD16 + NK cell activation, while targeting the FVIII heavy chain domains did not. We also show that rFVIIIFc binds CD16 with about five-fold higher affinity than rFIXFc. Based on our results we propose that FVIII light chain-mediated membrane binding results in tethering of the fusion protein to the cell surface, and this, together with increased binding affinity for CD16, allows for Fc-CD16 interactions to proceed, resulting in NK cellular activation. Our working model may explain our previous results where we observed that rFVIIIFc activated NK cells via CD16, whereas rFIXFc did not despite having identical IgG1 Fc domains.

59 BASIC BIOLOGICAL SCIENCES↗

Search for Weak Side Branches in the Electromagnetic Decay Paths of the 6526-keV 10 + Isomer in 54 Fe

High-spin nuclear isomers in $N≈Z$ nuclei between doubly magic 40 Ca and 56 Ni provide an excellent testing ground for the nuclear shell model and questions related to isospin symmetry breaking in the vicinity of the proton drip line. The purpose of the present study is to investigate the possibility of weak electromagnetic decay branches along the decay paths of the 6526-keV 10 + isomer in 54 Fe. The isomer was strongly populated by means of the fusion-evaporation reaction 24 Mg( 36 Ar,$α$2$p$) 54$m$ Fe. The Gammasphere array was used to detect $γ$-ray cascades emitted from the isomeric state. By means of $γγγ$ coincidences, weak non-yrast decay branches can be discriminated, with the isomer’s half-life confirmed at $T$ 1/2 = 363 (4) ns. The yrast ${6}_{1}^{+}$ → ${2}_{1}^{+}$ $E4$ cross-over transition was interrogated. The observations are compared with shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion Manipulation from Liquid Xe to Vacuum: Ba-Tagging for a nEXO Upgrade and Future 0 νββ Experiments

Neutrinoless double beta decay (0𝜈𝛽𝛽) provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for 0𝜈𝛽𝛽 decay in 136 Xe with a projected half-life sensitivity exceeding 10 28 years at the 90% confidence level using a liquid xenon (LXe) Time Projection Chamber (TPC) filled with 5 tonnes of Xe enriched to ∼90% in the 𝛽𝛽-decaying isotope 136 Xe. In parallel, a potential future upgrade to nEXO is being investigated with the aim to further suppress radioactive backgrounds and to confirm 𝛽𝛽-decay events. This technique, known as Ba-tagging, comprises extracting and identifying the 𝛽𝛽-decay daughter 136 Ba ion. One tagging approach being pursued involves extracting a small volume of LXe in the vicinity of a potential 𝛽𝛽-decay using a capillary tube and facilitating a liquid-to-gas phase transition by heating the capillary exit. The Ba ion is then separated from the accompanying Xe gas using a radio-frequency (RF) carpet and RF funnel, conclusively identifying the ion as 136 Ba via laser-fluorescence spectroscopy and mass spectrometry. Simultaneously, an accelerator-driven Ba ion source is being developed to validate and optimize this technique. The motivation for the project, the development of the different aspects, along with the current status and results, are discussed here.

a-tagging↗