Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Friction Tests in Magnesium Tube Hydroforming at Elevated Temperatures

In metal forming, lubricants have a variety of functions. The top priority is usually reduction of friction in order to increase the formability of the materials and reduce tool wear. Because magnesium alloys have very poor formability at room temperature, it is essential to manufacture a part from Magnesium alloys at elevated temperatures. The aim of this paper is to present a friction test method to evaluate the performance of different kinds of lubricants and determine their coefficients of friction at elevated temperatures in tube hydroforming of magnesium alloys. A self-designed experimental apparatus is used to carry out the experiments of friction tests. The coefficient of friction between the tube and die at guiding zone is determined. The effects of the internal pressure, the axial feeding velocity and temperatures on the friction forces and coefficients of friction for different lubricants are discussed.

36 MATERIALS SCIENCE↗

Basic coaxial mass driver construction and testing

A basic coaxial mass driver has been constructed by a group of students to verify performance predictions in the acceleration range envisaged for the first lunar device. The bucket is guided by four copper tubes which also supply direct current excitation for its single aluminum coil, and is accelerated by twenty coaxial coils along a 2 m track, followed by a deceleration section. The coils are individually energized by electrolytic photoflash capacitors triggered by solid state switches on the basis of bucket position.

Fine, K.↗

Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position measurements was equal to 0.79 mm(0.37 mm). The update rate and latency of the FBG-based needle position measurement were 100 and 300 ms, respectively. Conclusions: The FBG-based needle tracking procedure proposed in this paper is able to determine the position of the complete needle, under MR-imaging, with better accuracy and precision, higher update rate, and lower latency compared to current MR-based needle localization methods. This system would be eligible for MR-guided brachytherapy, in particular, for an improved needle guidance and reconstruction.

60 APPLIED LIFE SCIENCES↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Illumination of interior spaces by bended hollow light guides: Application of the theoretical light propagation method

To ensure comfort and healthy conditions in interior spaces the thermal, acoustics and daylight factors of the environment have to be considered in the building design. Due to effective energy performance in buildings the new technology and applications also in daylight engineering are sought such as tubular light guides. These allow the transport of natural light into the building core reducing energy consumption. A lot of installations with various geometrical and optical properties can be applied in real buildings. The simplest set of tubular light guide consists of a transparent cupola, direct tube with high reflected inner surface and a ceiling cover or diffuser redistributing light into the interior. Such vertical tubular guide is often used on flat roofs. When the roof construction is inclined a bend in the light guide system has to be installed. In this case the cupola is set on the sloped roof which collects sunlight and skylight from the seen part of the sky hemisphere as well as that reflected from the ground and opposite facades. In comparison with the vertical tube some additional light losses and distortions of the propagated light have to be expected in bended tubular light guides. Recently the theoretical model of light propagation was already published and its applications are presented in this study solving illuminance distributions on the ceiling cover interface and further illuminance distribution on the working plane in the interior. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

User's guide for a large signal computer model of the helical traveling wave tube

The use is described of a successful large-signal, two-dimensional (axisymmetric), deformable disk computer model of the helical traveling wave tube amplifier, an extensively revised and operationally simplified version. We also discuss program input and output and the auxiliary files necessary for operation. Included is a sample problem and its input data and output results. Interested parties may now obtain from the author the FORTRAN source code, auxiliary files, and sample input data on a standard floppy diskette, the contents of which are described herein.

Palmer, Raymond W.↗

Optimization of Kaplan Hydroturbine at Very Low Head With Rim-Driven Generator

The objective of the paper is to study the design and optimization of Kaplan hydroturbines for a very low head (less than 3 m), with a particular emphasis on the use of rim-drive electrical generators. The work is based on an experimental setup and computational fluid dynamics (CFD) analysis of various design parameters for maximum output power and efficiency. Two designs are presented in this paper. One is a 90-cm (35-in.) diameter vertical-oriented Kaplan hydroturbine system as an intended product capable of generating over 50 kW. The other is a smaller, 7.6-cm (3-in.) diameter horizontal-oriented system for prototyping and laboratory verification. Both are analyzed through CFD based on large eddy simulation (LES) of transient turbulence. Specific design for the runner and the stator, intake tube shape, as well as guide vanes upstream of the turbine was studied to get the most from the available head. The intent is to use 3D-printing manufacturing techniques, which may offer original design opportunities as well as the possibility of turbine and water conduit design customization as a function of the head and flow available from a specific site. Based on the CFD analysis, the 7.6-cm diameter system achieved the highest power output and the maximum efficiency at the rotational speed range of 1500–2000 rpm, while for the experimental testing, the optimum rotational speed range was 1000–1500 rpm. Because of the mismatch between CFD and experimental results, the CFD results were correlated due to the presence of air and friction; moreover, error and uncertainty analysis were presented for both methods. For the 90-cm case, the optimum performance was found at a rotational speed around 350 rpm according to the CFD results. Finally, investigating the shape of the intake tube of the hydroturbine setup can significantly increase the power output and the efficiency of the system.

Energy & Fuels↗

Fabrication of Single Crystal MgO Capsules

A method has been developed for machining MgO crystal blocks into forms for containing metallic and silicate liquids at temperatures up to 2,400 C, and pressures up to at least 320 kilobars. Possible custom shapes include tubes, rods, insulators, capsules, and guides. Key differences in this innovative method include drilling along the crystallographic zone axes, use of a vibration minimizing material to secure the workpiece, and constant flushing of material swarf with a cooling medium/lubricant (water). A single crystal MgO block is cut into a section .5 mm thick, 1 cm on a side, using a low-speed saw with a 0.004 blade. The cut is made parallel to the direction of cleavage. The block may be cut to any thickness to achieve the desired length of the piece. To minimize drilling vibrations, the MgO block is mounted on a piece of adhesive putty in a vise. The putty wad cradles the bottom half of the entire block. Diamond coring tools are used to drill the MgO to the desired custom shape, with water used to wet and wash the surface of swarf. Compressed air may also be used to remove swarf during breaks in drilling. The MgO workpiece must be kept cool at all times with water. After all the swarf is rinsed off, the piece is left to dry overnight. If the workpiece is still attached to the base of the MgO block after drilling, it may be cut off by using a diamond cutoff wheel on a rotary hand tool or by using a low-speed saw.

Danielson, Lisa↗

Mars Ascent Vehicle (MAV) Concept - Launch System Development

A Mars Ascent Vehicle (MAV) would be one component of potential Mars Sample Return (MSR) and would have to launch from the surface of Mars into orbit about Mars with a soil sample. A MAV is a small lightweight rocket that must survive various environmental conditions, including powered ascent through the Martian atmosphere. A concept for the MAV system design includes a launch tube mounted on top of a mobile rover or a stationary lander. The launch tube must thermally insulate the MAV on the surface of Mars, and then guide the MAV during the initial portion of the launch. A mechanical erector system is also necessary for moving the MAV and launch tube from a stowed configuration to a launch configuration. The launch system would have to perform these tasks while also meeting many design constraints. This paper is a systems engineering perspective that will examine the current development of the launch system including design concepts, design trades, driving issues, and analyses performed. Design trades include different launch configurations that would prevent rover or lander tip-over, as well as re-contact between the MAV and the launch tube. Additional trades include options for guiding the MAV out of the launch tube, whether using launch rails or sabots, and finding a reliable but simple mechanical erector system. Analyses include investigating the impact of ignition overpressure based on launch configuration, launch loads and sensitivities to the launch system design, and Entry, Descent and Landing loads. The key considerations for these design trades are overall system mass, size, and reliability.

Sonneveldt, Bryan↗

A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a prototype Open-close positron emission tomography system

We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternatives for Helium-3 in Multiplicity Counters

Alternatives to helium-3 are being actively pursued due to the shortage and rising costs of helium-3. For safeguards applications, there are a number of ongoing investigations to find alternatives that provide the same capability in a cost-effective manner. One of the greatest challenges is to find a comparable alternative for multiplicity counters, since they require high efficiency and short collection or die-away times. Work has been progressing on investigating three commercially available alternatives for high efficiency multiplicity counters: boron trifluoride (BF3) filled proportional tubes, boron-lined proportional tubes, and lithium fluoride with zinc sulfide coated light guides. The baseline multiplicity counter used for the investigation is the Epithermal Neutron Multiplicity Counter with 121 helium-3 filled tubes at 10 atmosphere pressure, which is a significant capability to match. The primary tool for the investigation has been modeling and simulation using the Monte Carlo N-Particle eXtended (MCNPX) radiation transport program, with experiments to validate the models. To directly calculate the coincidence rates in boron-lined (and possibly other) detectors, the MCNPX code has been enhanced to allow the existing coincidence tally to be used with energy deposition rather than neutron capture reactions. This allows boron-lined detectors to be modeled more accurately. Variations of tube number and diameter along with variations in the amount of inter-tube moderator have been conducted for the BF3 and boron-lined cases. Tube pressure was investigated for BF3, up to two atmospheres, as well as optimal boron thickness in the boron-lined tubes. The lithium fluoride was modeled as sheets of material with light guides in between, and the number and thickness of the sheets investigated. The amount of light guide, which in this case doubles as a moderator, was also optimized. The results of these modeling and simulation optimization investigations are described and results presented.

Ely, James H.↗

TU-AB-201-03: A Robot for the Automated Delivery of An Electromagnetic Tracking Sensor for the Localization of Brachytherapy Catheters

Purpose: To present a programmable robotic system for the accurate and fast deployment of an electromagnetic (EM) sensor for brachytherapy catheter localization. Methods: A robotic system for deployment of an EM sensor was designed and built. The system was programmed to increment the sensor position at specified time and space intervals. Sensor delivery accuracy was measured in a phantom using the localization of the EM sensor and tested in different environmental conditions. Accuracy was tested by measuring the distance between the physical locations reached by the sensor (measured by the EM tracker) and the intended programmed locations. Results: The system consisted of a stepper motor connected to drive wheels (that grip the cable to move the sensor) and a series of guides to connect to a brachytherapy transfer tube, all controlled by a programmable Arduino microprocessor. The total cost for parts was <$300. The positional accuracy of the sensor location was within 1 mm of the expected position provided by the motorized guide system. Acquisition speed to localize a brachytherapy catheter with 20 cm of active length was 10 seconds. The current design showed some cable slip and warping depending on environment temperature. Conclusion: The use of EM tracking for the localization of brachytherapy catheters has been previously demonstrated. Efficient data acquisition and artifact reduction requires fast and accurate deployment of an EM sensor in consistent, repeatable patterns, which cannot practically be achieved manually. The design of an inexpensive, programmable robot allowing for the precise deployment of stepping patterns was presented, and a prototype was built. Further engineering is necessary to ensure that the device provides efficient independent localization of brachytherapy catheters. This research was funded by the Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Study of light backgrounds from relativistic electrons in air light-guides

The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Moller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Moller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-driven plasma waves in capillary tubes

The excitation of plasma waves over a length of up to 8 cm is demonstrated using laser guiding of intense laser pulses through hydrogen-filled glass capillary tubes. The plasma waves are diagnosed by spectral analysis of the transmitted laser radiation. The dependence of the spectral redshift--measured as a function of filling pressure, capillary tube length, and incident laser energy - is in excellent agreement with simulation results. The longitudinal accelerating field inferred from the simulations is in the range of 1-10 GV/m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gastrostomy Tube Placement Without Nasogastric Tube: A Retrospective Evaluation in 85 Patients

Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncture of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗