Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “getters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Real-Time Detection of Hydrogen and Ammonia Isotopologues for Impurity Removal and Recovery of Tritium

To accommodate gas measurements for impurity removal and recovery of tritium, a silver-coated optical or waveguide is employed for collecting Raman scattered signals to determine relative hydrogen and ammonia isotopologue populations in real time. The data and results presented here demonstrate an analytical methodology for the analysis of four ammonia and three hydrogen isotopologues in a hydrogen–deuterium exchange reaction by gas phase Raman spectroscopy. Standard chemometric modeling techniques effectively unravel the signatures of the isotopologues involved observed here; however, a sophisticated quantum chemical approach supports the spectral assignments. An interpretation of the data presented here can emphasize the practicality and reliability of the gaseous monitoring system in complex chemical environments for the hydrogen fuel economy as well as the more distant energy source from a facility that handles tritium. There are still considerable concerns about the measurement of tritium in isotope separation and radiological impurities from gas processing. A common impurity in gas processing is ammonia, which can form readily in the presence of nitrogen and tritium. Substituted ammonia (NQ 3 ), where Q = H, D, or T, is traditionally removed through getters or diffusers along with other non-hydrogen contaminants. A preferable analytical approach is noninvasive and can be deployed for real-time process evaluation in radiological environments.

Ammonia↗

Iodine Vapor Reactions with Pure Metal Wires at Temperatures of 100–139 °C in Air

In this work, I 2(g) reactions with 11 metal wires (i.e., Al, Ag, Cu, In, Mo, Nb, Ni, Pd, Pt, Sn, Ta) were evaluated at three temperatures (i.e., 100 ± 3°C, 123 ± 4°C, 139 ± 5°C) with exposure times of 24 hours at each temperature. Over these temperatures, some of the metals showed increased mass gain with higher temperatures (i.e., In, Ag, Cu), Sn showed decreased iodine capture at increased temperatures, and most metals (i.e., Mo, Nb, Ni, Pd, Pt, and Ta) showed little to no mass gain at all temperatures. Silver mordenite (AgZ) was used as a standard during these studies and showed a consistent mass gain (m% I ) of 10.6 → 12.8% over this temperature range. The values of mass of iodine captured per mass of starting metal (g g -1 ) ranged widely across the study with the highest values achieved for (in descending order) Sn-T 100°C (4.37), In-T 139°C (3.34), Sn-T 123°C (1.98), In-T 123°C (1.57), Ag-T 139°C (1.19), In-T 100°C (0.97), and Cu-T 139°C (0.71). In some cases, the metal-iodide complex was not stable at the experimental temperature and it was clear some volatility had occurred during the experiment based on discoloration in the vials. These results show that some metals can have extensive reactions with I 2(g) without showing metal-iodide preferences over metal-oxide formation based on thermodynamic predictions. It is possible that materials such as these could be implemented near nuclear facilities to getter I 2(g) in the event of a nuclear accident.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multifunctional technology platform for sorbent construction using polyacrylonitrile scaffolds

Polyacrylonitrile (PAN) is a synthetic polymer that shows high potential for use in a wide range of environmental remediation applications. PAN can be implemented in various ways within a batch or continuous process stream for use as a passive scaffold holding active gettering materials in place or where the PAN scaffold (e.g., beads, fiber mats, membranes) is functionalized with active chelating groups (e.g., amine, hydrazide, amidoximes, carboxyl). Application spaces covered in this review include remediation of heavy metals (e.g., Ag, As, Cd, Cr6+, Cu, Pb, Sb, and Se), high-dose fission products (e.g., 90Sr, 137Cs), radioiodine (i.e., 129I), noble gases (i.e., Xe, 85Kr), rare earths (e.g., Ce, Y), and actinides (e.g., Am, Pu, U). Methods for producing PAN composite sorbents are discussed. Options are also discussed for removing the PAN matrix following chemisorption of an active contaminant to minimize waste volumes requiring disposal.

polyacrylonitrile, composite sorbents, sulfides, a↗

Study of Tritium Diffusivity in Pure and Sn-Defective Zr: A First-Principles Density Functional Theory Approach

Zirconium alloys (e.g., zircaloy-4) are used as tritium ( 3 H) getter materials in tritium-producing burnable absorber rods (TPBARs) owing to their ability to capture 3 H and chemically convert them into metal hydrides. Understanding of 3 H diffusion mechanisms in zircaloy is crucial for the optimal design of material performance in nuclear technology. Here, for this work, we perform first-principles density functional theory calculations to study the 3 H diffusion mechanism in pure and impure Zr with a low concentration of tin (Sn) atoms to determine the impact of the presence of Sn on the movement of 3 H atoms through the material. First, we calculated the diffusion barriers for 3 H in pure Zr by taking different migration pathways. We then introduced a low concentration of Sn impurity and systematically explored the impurity effect on the diffusion barriers for 3 H. Using our calculated diffusion energy barriers, we further obtained the diffusion coefficients and analyzed the results by comparing them with the experimental and previously calculated values. A diffusion coefficient of the order of 10 –8 m 2 /s is predicted. We also found that the presence of a Sn impurity could reduce the diffusivity up to 4 orders of magnitude. In conclusion, our results could serve as guidelines for further experimental investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iodine solid sorbent design: a literature review of the critical criteria for consideration

Designing sorbents for iodine capture in different conditions requires selection and optimization of a large and diverse range of variables. These variables fall into general categories (or features) of sorbent activity, sorbent stability, and the fate of the loaded material in terms of the disposal (waste form) options available. To illustrate, silver-loaded, high-porosity sorbents make for maximized iodine capture and less pressure drop in a column-based sorption system approach, however, this high porosity can lead to less mechanically stable sorbents. Additionally, waste forms containing silver must also be compliant with additional criteria for hazardous waste disposal. Thus, all these aspects must be considered simultaneously when selecting a sorbent for utilization under specific conditions. Information is given for different types of sorbent design considerations for different operating conditions and some emphasis is also given on promising alternatives for silver as the active (chemisorption-based) getter metal. Discussion is given around demonstrated options for waste forms for different metal-iodide compounds.

36 MATERIALS SCIENCE↗

Efficiently predicting pressure-composition-temperature diagrams to discover low-stability metal hydrides

Quantitatively accurate computational predictions of metal hydride thermodynamics are challenging but critical for alloy performance optimization across a multitude of technological domains, including hydrogen storage, compression, purification, and getters. Recent machine learning approaches have demonstrated great success in this area, but can potentially suffer from several shortcomings since they rely on imbalanced experimental training data and can have poor out-of-distribution (ood) test performance. Here, in this study, we circumvent such pitfalls by developing a computationally efficient, first principles-based workflow for direct prediction of metal hydride phase equilibrium, i.e., the pressure-composition-temperature (PCT) diagram. We then demonstrate its utility on predicting low stability hydrides derived from compositionally complex C14 Laves phase AB2 alloys. Specifically, we computationally predict and then experimentally validate an AB 2 alloy series (z < 0.6 for Ti 2−z Zr z CrMnFeNi) with ideal hydriding thermodynamics for a two-stage metal hydride-based compressor for pressurizing boil off from liquefied hydrogen. Importantly, this study lays the groundwork for accurate and efficient discovery/optimization of ood, low-stability hydrides for which purely data-driven approaches lack sufficient accuracy.

08 HYDROGEN↗

MBE growth and donor doping of coherent ultrawide bandgap AlGaN alloy layers on single-crystal AlN substrates

Single-crystal Aluminum Nitride (AlN) crystals enable the epitaxial growth of ultrawide bandgap Al(Ga)N alloys with drastically lower extended defect densities. Here, we report the plasma-MBE growth conditions for high Al-composition AlGaN alloys on single-crystal AlN substrates. An AlGaN growth guideline map is developed, leading to pseudomorphic Al x Ga 1–x N epitaxial layers with x ~0.6–1.0 Al contents at a growth rate of ~0.3 μm/h. These epitaxial layers exhibit atomic steps, indicating step flow epitaxial growth, and room-temperature band edge emission from ~4.5 to 5.9 eV. Growth conditions are identified in which the background impurity concentrations of O, C, Si, and H in the MBE layers are found to be very near or below detection limits. An interesting Si segregation and gettering behavior is observed at the epitaxial AlGaN/AlN heterojunction with significant implications for the formation and transport of 2D electron or hole gases. Well-controlled intentional Si doping ranging from ~2 × 10 17 to 3 × 10 19 atoms/cm 3 is obtained, with sharp dopant density transition profiles. In Si-doped Al 0.6 Ga 0.4 N epilayers, a room-temperature free electron concentration of ~3 × 10 19 /cm 3 , an electron mobility of ~27 cm 2 /V s, and an n-type resistivity of ~7.5 m Ω cm are obtained. Here, the implications of these findings on electronic and photonic devices on single-crystal AlN substrates are discussed.

36 MATERIALS SCIENCE↗

An atomic beam of titanium for ultracold atom experiments

Here we generate an atomic beam of titanium (Ti) using a “Ti-ball” Ti-sublimation pump, which is a common getter pump used in ultrahigh vacuum systems. We show that the sublimated atomic beam can be optically pumped into the metastable 3d 3 ( 4 F)4s a 5 F 5 state, which is the lower energy level in a cycling optical transition that can be used for laser cooling. We measure the atomic density and transverse and longitudinal velocity distributions of the beam through laser fluorescence spectroscopy. We find a metastable atomic flux density of 4.3(2) × 10 9 s -1 cm -2 with a mean forward velocity of 773(8) m/s at 2.55 cm directly downstream of the center of the Ti-ball. Owing to the details of optical pumping, the beam is highly collimated along the transverse axis parallel to the optical pumping beam and the flux density falls off as 1/r. We discuss how this source can be used to load atoms into a magneto-optical trap.

47 OTHER INSTRUMENTATION↗

Nanodiffraction imaging of ionically driven phase separation in cobaltite heterostructures

Controlling the anionic stoichiometry and distribution of perovskite cobaltites presents a powerful method for tailoring the magnetic and electronic properties for magneto-ionic applications. Nevertheless, the influence of nanoscale morphology, including phase separation and defects in cobaltite heterostructures, remains largely unexplored. We used x-ray nanodiffraction to directly image the nanoscale topotactic phase transformation in La 1−x Sr x CoO 3 (LSCO) heterostructures capped with a reactive aluminum (Al) layer (i.e., oxygen “getter”) of varying thicknesses (0.5, 3, and 7 nm). Nanodiffraction images reveal the formation of highly elongated BM filaments extending over mesoscopic lengths (>67 μm), indicating a strong tendency toward oxygen vacancy ordering in both P and BM phases in all heterostructures. Local strain and strain gradient analysis shows a strong correlation between the depletion of the P phase and strain gradients. Our measurements suggest that elongation of the BM filaments is the predominant mechanism for topotactic transformation in LSCO/Al heterostructures, preferred over coarsening, branching, and fractal growth. Our study provides a detailed nanoscale analysis of ionically driven phase transitions in LSCO/Al heterostructures, which is crucial for tailoring the functional properties of cobaltites for magneto-ionic devices.

36 MATERIALS SCIENCE↗

First lithium experiments in HIDRA and evidence of helium retention during quasi-steady-state stellarator plasma operations

Recent experiments in Hybrid Illinois Device for Research and Applications (HIDRA) have had operational discharges between t discharge = 60 and 1000 s using electron cyclotron resonant heating (ECRH) of the plasma. This means that quasi-steady-state plasma discharges reach conditions to study long-pulse plasma material interactions (PMIs). The newly commissioned HIDRA-Material Analysis Test-stand PMI diagnostic is used to place a drop of lithium onto a heated tungsten surface, transfer the sample in-vacuo and expose it in a helium plasma. Helium is of interest as there is an open question to whether lithium will be able to remove helium ash in real fusion devices. The introduction of the W-Li sample in HIDRA resulted in evaporation of lithium into the helium plasma during a 600 s pulse and caused a reduction of over 90% in neutral pressure during the discharge. It was also observed that the plasma density and temperature increased by over 2.5 times. Using spectroscopy and a helium collisional radiative model, the peak temperature and density of the helium plasma can be monitored during the discharge. During lithium evaporation, as significant lithium ionization occurs, there is a 85% drop in the HIDRA vessel neutral pressure, despite a constant flow rate of He gas. This reduction in neutral pressure is supported by spectroscopy data with corresponding reductions in He I line intensities (587 nm, 667 nm, 706 nm, and 728 nm), as well as those of other impurities. At one point in the discharge a lithium plasma is created, as indicated by an increase in Li + emission and a complete reduction in He + emission, but the electron density jumps from ne = 3 × 10 18 m –3 to over ne = 8 × 10 18 m –3 while the core temperature stays relatively constant between Te = 16 eV and 20 eV. Once lithium has completely evaporated from the sample and the majority of the ionized lithium has diffused from the plasma to the vessel walls, pressure and spectroscopy data paired with He collisional radiative model calculations shows a re-establishment of a helium plasma in a low recycling regime. In this regime, the density drops down to ne = 2 × 10 18 m –3 and the electron temperature increases from T e = 20 eV to over T e = 50 eV indicating an increase in helium heating efficiency. This is also indicated by the He+ emission re-establishing and having a higher intensity. Here, we show the results from the first lithium campaign in HIDRA. In the presence of lithium, and in particular when lithium ions are present, the helium disappears from the plasma via an as of yet unknown complex relationship that needs to be further studied. The most likely explanation is that the lithium ions are distributed around the vessel and able to trap helium to the surface turning HIDRA into a large gettering surface. These results have potential implications on future plasma facing component design using liquid lithium for impurity and recycling control using limiters and divertors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study on boron distribution and transport at plasma-facing components during impurity powder dropping in the Large Helical Device

Toward real-time wall conditioning, impurity powder dropping experiments with boron powder were performed in the 22nd experimental campaign of the Large Helical Device. To examine the deposition and desorption process of boron, we focus on boron hydride (BH) molecules which presumably populate near plasma-facing components. We performed spatially-resolved spectroscopic measurements of emission by boron ions and BH molecules. From the measurement, we found that BH and B + were concentrated on the divertor viewing chord, which suggest boron deposition in the divertor region. By comparing Hγ emissions with and without boron injection, neutral hydrogen shows uniform reduction in the SOL region, whereas less reduction of neutral hydrogen is confirmed in the divertor region. Although emissions from BH and B + increased linearly, emissions by B0 and B4 + became constant after the middle of the discharge. Continuous reduction of carbon density in the core plasma was confirmed even after B 0 and B 4 + became constant. The results may show reduction of hydrogen recycling and facilitation of impurity gettering by boron in the divertor region and thus effective real-time wall conditioning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma modification through boron particulate injection in the full tungsten environment of WEST

Recent experiments have confirmed the compatibility of extended boron particulate injections with high performance plasma discharges in the full tungsten (W) environment of WEST. Utilizing an impurity powder dropper (IPD) equipped with boron (B) powders a series of extended experimental programs providing controlled injections have quantified plasma response to varying levels of injection rate and total injection quantity. Calibration of injection quantities confirmed through post-situ testing of the IPD and cross-correlated with both high-speed camera illumination and spectroscopic measurement have allowed for the first time a fine scale determination of the effects of powder introduction on plasma performance. Plasma enhancement, consistent with turbulence reduction through profile modification, has been observed with sustained increases in the stored energy (WMHD), by 18%, electron temperature (T e ) by 35%, and neutron rate (N n ) by up to 200%, all of which scale positively with increasing powder injection rates. These injections have also resulted in both prompt and extended reductions in native impurity content, decreases in post injection radiated power, and strong decreases in divertor deuterium signatures signifying a reduction in recycling suggesting enhanced boron layer formation which provides a reduction of source terms and leads to enhanced gettering of main ion and impurity sources.

Lunsford, R. [Princeton Plasma Physics Laboratory ↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

Detection of hot electrons originating from an upper valley at ∼1.7eV above the Γ valley in wurtzite GaN using electron emission spectroscopy

Using electron emission spectroscopy, measurement and analysis were conducted on the energy distribution of vacuum emitted electrons from electrically driven InGaN/GaN green (peak wavelengths 𝜆 ≈ 515nm) light-emitting diodes (LEDs) with and without a prewell superlattice (SL). Here, we report on the detection of a high-energy upper valley at ∼ 1.7eV above the Γ valley from samples with no prewell SL. We propose that these upper valley electrons originate predominantly from trap-assisted Auger recombination (TAAR) in green LEDs, as the intensity of these peaks is found to have quadratic dependence on the carrier density 𝑛 [see Espenlaub et al., J. Appl. Phys. 126, 184502 (2019)]. The high-energy upper valley peak was not observed in the sample with a prewell SL which is attributed to gettering by the prewell SL of still unidentified impurities that act as TAAR centers.

carrier generation & recombination↗

Mitigating Process Induced Degradation in p- and n-Czochralski Silicon Wafers with Tabula Rasa

We report on the bulk properties of of n- and p- type Czochralski silicon (Cz-Si) after a high-temperature annealing process known as Tabula Rasa (TR), which is primarily used to annihilate oxygen precipitates. We find significant differences in n- and p-type substrates as well as a strong dependence on the ambient in the resulting process induced degradation. We attribute this ambient dependence to either injection of interstitials or vacancies into the bulk during TR. Finally, we show that subsequent gettering is enhanced due to the annihilation of oxygen precipitates.

14 SOLAR ENERGY↗

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

Little, Bethany J. (ORCID:0000000332892798)↗

Side-by-side evaluation of the outgassing rate and ultimate pressure achieved inside tubes made of low-carbon and stainless steel

The hydrogen outgassing rate of a vacuum chamber made of AISI 1020 low-carbon steel was found to be notably smaller than a similar chamber made of AISI 316L stainless steel following heat treatment at 150 °C. When the chambers were baked at 400 °C, the outgassing rate of the 1020 low-carbon steel chamber was approximately 2000 times smaller than that of the 316L stainless-steel chamber. After quantifying hydrogen outgassing rates, vacuum chambers made of 1020 low-carbon steel and 316L stainless steel were heated for a prescribed duration and then pumped with an ion pump and nonevaporable getter pump to reach “ultimate pressure.” The 1020 low-carbon steel chamber reached lower pressures than the 316L stainless-steel chamber. Monte Carlo simulation predictions using the measured hydrogen outgassing rates are in good agreement with the ultimate pressure measurements. Finally, our measurements indicate that low-carbon steel can provide pressures within the extreme high vacuum range (<7.5 × 10 -13 Torr) if care is taken to minimize the surface area contribution from stainless steel.

36 MATERIALS SCIENCE↗