Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “geometric learning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Exploiting the Shape of CAN Data for In-Vehicle Intrusion Detection

Modern vehicles rely on scores of electronic control units (ECUs) broadcasting messages over a few controller area networks (CANs). Bereft of security features, in-vehicle CANs are exposed to cyber manipulation and multiple researches have proved viable, life-threatening cyber attacks. Complicating the issue, CAN messages lack a common mapping of functions to commands, so packets are observable but not easily decipherable. We present a transformational approach to CAN IDS that exploits the geometric properties of CAN data to inform two novel detectors - one based on distance from a learned, lower dimensional manifold and the other on discontinuities of the manifold over time. Proof-of-concept tests are presented by implementing a potential attack approach on a driving vehicle. The initial results suggest that (1) the first detector requires additional refinement but does hold promise; (2) the second detector gives a clear, strong indicator of the attack; and (3) the algorithms keep pace with high-speed CAN messages. As our approach is data-driven it provides a vehicle-agnostic IDS that eliminates the need to reverse engineer CAN messages and can be ported to an after-market plugin.

Tyree, Zachariah↗

Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning

Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP of brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In their experience, these strategies provide robust, high fidelity, high contrast MR images suitable for external beam RTP.

60 APPLIED LIFE SCIENCES↗

A Machine Learning Framework for Predicting Microphysical Properties of Ice Crystals From Cloud Particle Imagery

The microphysical properties of ice crystals are important because they significantly alter the radiative properties and spatiotemporal distributions of clouds, which in turn strongly affect Earth's climate. However, it is challenging to measure key properties of ice crystals, such as mass or morphological features. Here, we present a proof-of-concept framework for predicting three-dimensional (3D) microphysical properties of ice crystals from in situ two-dimensional (2D) imagery. First, we computationally generated synthetic ice crystals using 3D modeling software along with geometric parameters estimated from the 2021 Ice Cryo-Encapsulation Balloon (ICEBall) field campaign. Then, we used synthetic crystals to train machine learning (ML) models to predict effective density ($ρ_e$), effective surface area ($A_e$), and number of bullets ($N_b$) from synthetic rosette imagery. On unseen synthetic images, our ML models accurately predicted ice crystal properties. ResNet-18 performed best, achieving $R^2$ values of 0.99 and 0.98 for $ρ_e$ and $A_e$, respectively, and MAE of 0.10 for mathematical equation in single view tasks. Stereo view ResNet-18 further reduced RMSE by 40% for $ρ_e$ and $A_e$ and reduced MAE by 0.08 for $N_b$. This work provides a novel ML-driven framework for estimating ice microphysical properties from in situ imagery, which will allow for downstream constraints on microphysical parameterizations, such as the mass-size relationship.

Ko, J. [Columbia Univ., New York, NY (United State↗

Operational resilience of additively manufactured parts to stealthy cyberphysical attacks using geometric and process digital twins

Cyberphysical attacks on the digital backbone of Additive Manufacturing (AM) can compromise the printed part’s functionality. They can alter features in the digital geometry to introduce geometric defects (e.g., missing fillets) or alter process parameters to create local defects (e.g., voids). Addressing the downtime, waste, and quality deterioration associated with existing solutions requires operational resilience, i.e., rapid elimination or disruption of defect formation (to retain part function) without production stoppage or part disposal (to retain yield). This need is unmet due to the inherently unpredictable nature of attack-induced alterations, lack of access to the original geometric model for identification of altered geometric features, and in-process imposition of unknown process dynamics via attack-driven alteration of real-time-uncontrolled (or exogenous) parameters. This work establishes the above-mentioned operational resilience for the first time by creating two Digital Twins (DT). The Geometric DT (Geo-DT) is based on a unique physical-field-driven soft sensor and topology optimization method. The Process Digital Twin (Pro-DT) combines local defect quantification with a novel Reinforcement Learning formulation and training method. The importance of these methodological advances and the scalability of our approach are examined on a real AM testbed. It is shown that Geo-DT can correct geometric defects without access to the original digital geometry or explicit knowledge of attack-altered geometric features. Further, Pro-DT can accelerate real-time disruption of local defects despite attack-driven imposition of unknown process dynamics. We discuss how our framework goes beyond the contemporary focus on pre-attack security and in-attack detection towards resilience for AM and beyond.

Additive Manufacturing↗

Lidar Cloud Detection with Fully Convolutional Networks

In this contribution, we present a novel approach for segmenting laser radar (lidar) imagery into geometric time- height cloud locations with a fully convolutional network (FCN). We describe a semi-supervised learning method to train the FCN by: pre-training the classification layers of the FCN with image-level annotations, pre-training the en- tire FCN with the cloud locations of the MPLCMASK cloud mask algorithm, and fully supervised learning with hand-labeled cloud locations. We show the model achieves higher levels of cloud identification compared to the cloud mask algorithm implementation.

Cromwell, Erol LD↗

Unraveling Adsorbate-Induced Structural Evolution of Iron Carbide Nanoparticles

Iron carbide (Fe x C y ) nanoparticles (NPs) are promising candidates for replacing platinum group metals in industrial applications, such as high-temperature Fischer–Tropsch synthesis. However, due to their amorphous nature, characterization of the active sites has been challenging experimentally and computationally. Here, using a combined density functional theory (DFT), neural network interatomic potential-assisted global optimization, and ensemble learning study, we evaluate dynamic surface changes associated with syngas (H and CO) interactions. For this purpose, we have developed a general procedure that we use to model an experimentally relevant 270-atom Fe 182 C 88 NP using the neural network-assisted stochastic surface walk global optimization algorithm (SSW-NN). Once generated, the Fe 182 C 88 NP active sites and particle morphology are thoroughly characterized before the effects of syngas adsorbate interactions are explored by using DFT and molecular dynamics simulations. Lastly, we explore correlations between geometric and electronic features of the active sites and the adsorption of H (H ads ), using a regularized random forest machine learning algorithm. In doing so, we identified the Fe–C coordination number and p orbital occupancy as the most important descriptors affecting H ads . Furthermore, using a combined ML and quantum chemistry approach, our work demonstrates a general and efficient procedure for generating and probing complex surface phenomena on binary nanoparticles.

Adsorption↗

A generalized deep learning approach for local structure identification in molecular simulations

Identifying local structure in molecular simulations is of utmost importance. The most common existing approach to identify local structure is to calculate some geometrical quantity referred to as an order parameter. In simple cases order parameters are physically intuitive and trivial to develop (e.g., ion-pair distance), however in most cases, order parameter development becomes a much more difficult endeavor (e.g., crystal structure identification). Using ideas from computer vision, we adapt a specific type of neural network called a PointNet to identify local structural environments in molecular simulations. A primary challenge in applying machine learning techniques to simulation is selecting the appropriate input features. This challenge is system-specific and requires significant human input and intuition. In contrast, our approach is a generic framework that requires no system-specific feature engineering and operates on the raw output of the simulations, i.e., atomic positions. We demonstrate the method on crystal structure identification in Lennard-Jones (four different phases), water (eight different phases), and mesophase (six different phases) systems. The method achieves as high as 99.5% accuracy in crystal structure identification. The method is applicable to heterogeneous nucleation and it can even predict the crystal phases of atoms near external interfaces. We demonstrate the versatility of our approach by using our method to identify surface hydrophobicity based solely upon positions and orientations of surrounding water molecules. Our results suggest the approach will be broadly applicable to many types of local structure in simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perspective Imagery in Synthetic Scenes used to Control and Guide Aircraft during Landing and Taxi: Some Issues and Concerns

Perspective synthetic displays that supplement, or supplant, the optical windows traditionally used for guidance and control of aircraft are accompanied by potentially significant human factors problems related to the optical geometric conformality of the display. Such geometric conformality is broken when optical features are not in the location they would be if directly viewed through a window. This often occurs when the scene is relayed or generated from a location different from the pilot s eyepoint. However, assuming no large visual/vestibular effects, a pilot cad often learn to use such a display very effectively. Important problems may arise, however, when display accuracy or consistency is compromised, and this can usually be related to geometrical discrepancies between how the synthetic visual scene behaves and how the visual scene through a window behaves. In addition to these issues, this paper examines the potentially critical problem of the disorientation that can arise when both a synthetic display and a real window are present in a flight deck, and no consistent visual interpretation is available.

Johnson, Walter W.↗

Characterization and prediction of the electromechanical wear of contact tips during wire arc additive manufacturing of 316L stainless steel

Here, this study seeks to better understand the degradation of the contact tip with respect to WAAM for a 316L wire electrode as well as explore methods of monitoring the contact tip state from process data. The contact tip, a consumable component, positions the wire and serves as the electrical contact surface between the wire electrode and the welding power supply. The wear of the contact tip was characterized in terms of material loss and material contamination for a set of tips worn to discrete levels as measured by the amount of wire fed or arc time. Geometrical characterization found a 49% increase in the bore exit area at 180 meters of wire fed. Machine learning models were developed to predict the relative bore exit area of the contact tip from arc-based process data and a random forest classifier exhibited favorable performance with a cross-validated f1-score of 0.84. The regression architecture implemented a multi-layer perceptron with the ability to predict the relative exit area with an $R^2$ score of 0.75. Key features used in the prediction include the standard deviation of the voltage and the time between shorts.

Contact tip wear↗

Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features were selected during the tenfold cross-validation training. The average area under the ROC curve (AUC) value for training was 0.87 ± 0.01 and the AUC value for validation was 0.85 ± 0.01. Using the NCP score, FROC analysis of the validation set showed that the FP rates were reduced to 3.16, 1.90, and 1.39 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. Conclusions: The topological soft-gradient prescreening method in combination with the luminal analysis for FP reduction was effective for detection of NCPs in cCTA, including NCPs causing positive or negative vessel remodeling. The accuracy of vessel segmentation, tracking, and centerline identification has a strong impact on NCP detection. Studies are underway to further improve these techniques and reduce the FPs of the CADe system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Micromechanical Surrogate Machine Learning Model for Creep Deformation Modeling

Process variability during the manufacture of gas turbine engine hot section components can significantly affect the material’s resulting microstructure. In casting, for instance, geometric variation within a component (thin sections versus thick sections, radial location) influences cooling rates and the resulting grain size. The high temperature creep response is known to be sensitive to grain size owing to a diffusional creep mechanism which occurs more readily along grain boundaries. Microstructural variation correspondingly drives mechanical behavior which propagates into component scale performance uncertainty. These factors are essential when planning inspection, maintenance, and repair strategies within a reliability framework. These benefits provide opportunities to increase overall energy efficiency through refined margins. Critically, there is an opportunity to bolster existing data-driven reliability models using physics-driven process-structure-property relations. Here we present recent work establishing a framework for evaluating the probabilistic creep performance of high-temperature materials. A novel microstructure-sensitive crystal plasticity finite element model is established that captures both grain boundary and crystallographic deformation effects. The computationally expensive physics model is calibrated using a statistical approach and this high-fidelity model is subsequently used to train a computationally efficient machine learning surrogate model. The surrogate model is essential for sampling a large ensemble of simulated structure-property pair results. The ensemble data are then mined to extract salient trends to be incorporated into a microstructure-sensitive reliability model. The proposed approach represents a novel way to capture microstructure-sensitive trends from physics-based models within a modern reliability framework.

Fernandez-Zelaia, Patxi [ORNL]↗

WE-B-BRD-00: MRI for Radiation Oncology

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-01: MR-LINAC

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-02: MR Simulation for Radiation Therapy

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-03: MR QA/QC for MRgRT

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

DeepBench: A simulation package for physical benchmarking data

We introduce **DeepBench**, a python library that generates simple simulated image data from first principles, such as basic geometric shapes and astronomical objects. These data are highly valuable for developing (calibration, testing, and benchmarking) statistical and machine learning models because they make it possible to connect the final data product to physically interpretable inputs. This software includes tools to curate and store the datasets to maximize reproducibility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prediction of Solute Segregation at Metal/Oxide Interfaces Using Machine Learning Approaches

The atomic structure and chemistry at metal/oxide interfaces play a crucial role in determining their properties. However, studying semi-coherent metal/oxide interfaces that include misfit dislocations through density functional theory (DFT) is often computationally expensive due to the large number of atoms involved, ranging from hundreds to thousands. In this study, we explore solute segregation behavior at the Fe/Y 2 O 3 interface—an important model interface for cladding applications in nuclear fission reactors—by combining DFT calculations with a machine learning (ML) approach. ML models are trained using DFT-calculated segregation energies (𝐸 𝑆𝑒𝑔 ) to identify the key chemical and geometric factors influencing solute segregation at metal/oxide interfaces, revealing the competition between these features in determining 𝐸 𝑆𝑒𝑔 . Moreover, the segregation behavior at a specific Fe/Y 2 O 3 interface is predicted with high accuracy using ML models trained on data from this interface. Furthermore, it is found that the ML models could also predict solute segregation at a different Fe/Y 2 O 3 interface with a new orientation relationship (OR), at a computational cost of less than 1/45 of that required for similar DFT calculations.

36 - MATERIALS SCIENCE↗

SU-D-BRB-01: A Comparison of Learning Methods for Knowledge Based Dose Prediction for Coplanar and Non-Coplanar Liver Radiotherapy

Purpose: The predictive power of knowledge based planning (KBP) has considerable potential in the development of automated treatment planning. Here, we examine the predictive capabilities and accuracy of previously reported KBP methods, as well as an artificial neural networks (ANN) method. Furthermore, we compare the predictive accuracy of these methods on coplanar volumetric-modulated arc therapy (VMAT) and non-coplanar 4π radiotherapy. Methods: 30 liver SBRT patients previously treated using coplanar VMAT were selected for this study. The patients were re-planned using 4π radiotherapy, which involves 20 optimally selected non-coplanar IMRT fields. ANNs were used to incorporate enhanced geometric information including liver and PTV size, prescription dose, patient girth, and proximity to beams. The performance of ANN was compared to three methods from statistical voxel dose learning (SVDL), wherein the doses of voxels sharing the same distance to the PTV are approximated by either taking the median of the distribution, non-parametric fitting, or skew-normal fitting. These three methods were shown to be capable of predicting DVH, but only median approximation can predict 3D dose. Prediction methods were tested using leave-one-out cross-validation tests and evaluated using residual sum of squares (RSS) for DVH and 3D dose predictions. Results: DVH prediction using non-parametric fitting had the lowest average RSS with 0.1176(4π) and 0.1633(VMAT), compared to 0.4879(4π) and 1.8744(VMAT) RSS for ANN. 3D dose prediction with median approximation had lower RSS with 12.02(4π) and 29.22(VMAT), compared to 27.95(4π) and 130.9(VMAT) for ANN. Conclusion: Paradoxically, although the ANNs included geometric features in addition to the distances to the PTV, it did not perform better in predicting DVH or 3D dose compared to simpler, faster methods based on the distances alone. The study further confirms that the prediction of 4π non-coplanar plans were more accurate than VMAT. NIH R43CA183390 and R01CA188300.

60 APPLIED LIFE SCIENCES↗