Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Synergy of Gamma-Ray Burst Detectors in the GLAST Era

Simultaneous observations by the large number of gamma-ray burst detectors operating in the GLAST era will provide the spectra, lightcurves and locations necessary for studying burst physics and testing the putative relations between intrinsic burst properties. 1 will review the burst detection sensitivities, spectral bands, and localization capabilities of the GLAST (GBM and LAT), Swift (BAT), INTEGRAL (ISGRI), Suzaku (WAM), AGILE (Super-AGILE) and Wind (Konus) detectors; the detectors' energy band and the accumulation timescale of their trigger system affect their sensitivity to hard vs. soft and long vs. short bursts. In addition, I estimate the rate of simultaneous burst observations. In particular, coordination of the Swift observing plan consistent with Swift's other science objectives could increase the rate of GLAST bursts with redshifts.

Band, David L.↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A position-sensitive germanium detector for gamma-ray astronomy

The critical problem in high-resolution cosmic gamma-ray spectroscopy in the energy range from 0.02 to 10 MeV is the limited spectral sensitivity of the detectors used. This results from the small effective area of the detectors and the high background noise due to induced radioactivity and scattering in the detectors' high-energy particle environment. The effective area can be increased by increasing the number of detectors, but this becomes prohibitive because of the size and expense of the resulting instrument. We have taken a new approach: a segmented large-volume germanium gamma-ray detector which can effectively discriminate against internal background yet maintain the high spectral resolution and efficiency of conventional coaxial Ge detectors. To verify this concept, a planar detector divided into two segments has been fabricated and laboratory measurements agree well with Monte Carlo calculations. A large coaxial detector which will be divided into five segments is being built using the techniques developed for the planar detector. Monte Carlo calculations show that the sensitivity (minimum detectable flux) of the segmented coaxial detector is a factor of 2-3 better than conventional detectors because of the reduction in the internal background.

Varnell, L. S.↗

GAMMA SPECTRUM STABILIZATION FOR ENVIRONMENTAL RADIATION MONITORING STATIONS USING NAI(TL) DETECTOR

Abstract Gamma spectrum measured by an NaI(Tl) detector is known to be unstable with the in situ temperature. In the present work, an advanced method has been applied to stabilize the gamma spectrum measured by the NaI(Tl) detector at environmental radiation monitoring (ERM) stations. The method is based on experimental data obtained under controlled conditions in laboratory. In the temperature range from 4 to 45°C, the relative deviation of the peak positions within the stabilized gamma spectrum is less than 2%. To test this method in a real scenario, it has been integrated into the ERM station at the Military Institute of Chemical and Environmental Engineering in Hanoi, Vietnam. The results show that the proposed method is ready for a real application.

Hung, Dinh Tien↗

Identify and Assess Technical Challenges in Safeguards Measurements of Spent Advanced Reactor Fuels

Advanced reactor (AR) designs use various nuclear fuel types that can be significantly different than conventional light-water reactor (LWR) fuels, including differences in sizes, compositions, and chemical forms (e.g., oxide, carbide, metal). Nearly all the proposed AR fuels use high-assay low-enriched uranium (HALEU), which will have higher enrichments (5–20 wt% 235 U) than LWR fuels (currently limited to <5 wt% 235 U). In advance of the wide use of these new fuel types around the world, international safeguards organizations such as the International Atomic Energy Agency (IAEA]) are working with some of the AR vendors to formulate safeguards approaches for these AR fuel cycles. As part of the overall safeguards approach, it is important to identify the potential technical challenges in performing safeguards verification measurements of these AR fuels (both fresh and spent fuels) in advance of the widespread adoption of these new fuel types, because new safeguards technologies can take several years to develop, test, and approve for use. This report documents work performed in fiscal year 2024 based on modeling and simulation to assess the performance of the existing safeguards measurement technologies for irradiated or spent AR fuel elements or items. This work is a continuation of the work performed in fiscal year 2023 that focused on fresh AR fuels. Spent AR fuels have a distinct difference from their LWR counterparts: unlike the spent LWR fuels typically stored in a water-filled pool, some spent AR fuels—such as tristructural-isotropic (TRISO)-based fuels—will most likely be stored in air-filled hot cells. Because most safeguards measurements on spent fuel performed to date have been conducted under water, the air-filled hot cell environment could present unique challenges to safeguards measurements. Fork detector (FDET) and Cerenkov viewing device (CVD) systems have been the two primary instruments used by the IAEA for several decades to measure spent LWR fuel assemblies stored in pools for safeguards verification purposes. Because the lower refractive index of air causes Cerenkov light to be of lower intensity in air than in water, existing CVDs are likely unable to perform safeguards verification measurements for spent fuel stored in an air-filled hot cell, as is the case for the TRISO-based spent fuel elements (e.g., pebbles, graphite fuel blocks). Unlike FDET measurements, CVD measurements do not require fuel be moved, so they are a simpler and faster to take than FDET measurements. The inability to perform CVD measurements on the TRISO-based AR fuel types presents a major technical challenge in the effort to use existing technology to perform safeguards measurements on spent AR fuels. This study was mainly conducted through the modeling and simulation of an FDET or an FDET-like system on five spent AR fuel types, including one metallic fuel type and four TRISO-based fuel types in both pebble and graphite block forms in their respective storage configurations and environments. Because the various AR fuel types have significantly different dimensions, FDET systems must be adapted to accommodate them. Partial defect tests were also simulated in this study to assess the FDET’s ability to detect potential fuel diversions. The FDET measures the fuel’s total passive neutron and gamma emissions. The simulated FDET results from spent AR fuel items are compared against results from a typical spent pressurized water reactor (PWR) assembly. High-purity germanium (HPGe) gamma detector measurements were also simulated for the spent AR fuel types and the PWR assembly because the signature photopeaks have been used in LWR safeguards verifications, although HPGe is usually not used to detect diversions because of the fuel’s self-attenuation effects on those photopeaks. The results indicate that these detectors have significant challenges in performing safeguards measurements of the spent AR fuel items, including incompatibilities between AR fuel items and existing FDETs, lower neutron count rates, lower sensitivities to fuel diversions in certain AR fuel items, and significantly higher interference from a neighboring fuel item when the measurement is performed in air. These results suggest that an alternative technology or significant and timely technology development is needed to perform adequate safeguards measurements of some of these AR fuel items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation hot spot formation on UF 6 30B cylinders

The accurate material accountancy of a country's enriched uranium hexafluoride (UF 6 ) stockpiles is imperative to the International Atomic Energy Agency (IAEA) for determining appropriate material safeguards. Uranium hexafluoride is typically stored in large cylinders with enrichment verification typically performed with a NaI gamma detector using the enrichment meter method. This approach for calculating enrichment assumes that the UF 6 is homogeneous inside the cylinder. Here, the measurements and tests presented in this manuscript show that the UF 6 in cylinders left outside in the elements can experience fractionation, leading to inhomogeneity, and subsequent development of radiation hot spots. These hot spot locations can produce errant enrichment measurements. In dark-colored cylinders that experience significant surface heating from the sun, UF 6 sublimates off the cylinder walls, leaving only the uranium daughter products in a horizontal patch (stripe) along the cylinder's midline. This daughter patch is hypothesized to be the source of the radiation hot spots. The patch forms during the summer and tends to decay away during the winter, when solar intensity and temperatures are reduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum: Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Regretfully, the author list of the original paper did not contain the members of the groups being responsible for the HPGe screening, Radon emanation measurement and ICPMS surface characterization works. As the work performed is to be considered more than “just service work”, the authors together with the members of these groups have decided to amend the authors list. At publication the following authors were not included in the author list: • From Pacific Northwest National Laboratory, Richland, WA, U.S.A.: E.W. Hoppe, I.J. Arnquist, K.P. Hobbs, A.D. French, M.L. diVacri • From INFN, Laboratori Nazionali del Gran Sasso, 67100 Assergi, Italy: M. Laubenstein • From M. Smoluchowski Institute of Physics, Jagiellonian University, 30-348 Krakow, Poland: G. Zuzel The metadata of the present erratum are already correct.

99 GENERAL AND MISCELLANEOUS↗

Godiva Experiments for the Nuclear Criticality Safety Program (NCSP)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5 percent molybdenum for strength. Godiva is one of the last such critical assemblies in the United States, and can be used for studies of super-prompt critical behavior as well as irradiations and demonstrations. A demonstration of a Godiva burst is usually performed as a highlight of the hands-on portion of the Criticality Safety Training Classes taught at the National Criticality Experiment Research Center (NCERC). The Godiva burst is used to demonstrate the concept of super-prompt critical and the time-scale of a criticality accident. In addition, several NCSP projects have been conducted on Godiva IV over the past two years. One experiment focused on collecting data to support multiphysics simulations using Photo-Doppler Velocimetry (PDV) to measure surface movement and gamma detectors to measure the burst output as the burst develops from background to peak over ten orders of magnitude. Another experiment was performed to demonstrate the functionality of the Criticality Accident Alarm System (CAAS) system developed for installation in the Y-12 Uranium Processing Facility (UPF). The system must not only respond to a criticality event and alarm, but must also be shown to operate in a high dose environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

RASA Field Performance at US International Monitoring Stations

This report attempts to collate, analyze, and summarize RASA performance over time at each of 11 US operated IMS stations. The performance over time was compared to routine maintenance operations. The data, in general, were summarized into a set analyzed almost exclusively in Excel. The data set allows for further probing into RASA performance over time. The data set would permit data to be routinely added for continued analysis. In general, all RASA systems ran within the CTBTO mandated the MDA requirements over their current lifetime of operations. The largest impacts to performance appeared to arise from variabilities of Germanium gamma detectors as they were replaced. It is noted that the air volumes of samples were not provided and had to be assumed to be constant over the period analyzed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Trade Study of Nondestructive Assay Technologies

The purpose of this report is to summarize the capabilities of currently existing NDA technologies that can be applied to holdup measurements. Cataloguing the strengths and weaknesses of the existing state of the art is a necessary step towards setting goals for new technology development. The NDA technologies evaluated in this report include gamma imaging, non-imaging gamma detectors, and neutron coincidence counting. These technologies were chosen based on their potential for technological improvement or to be applied in different settings. Each technology will be analyzed on a set of evaluation criteria chosen to represent the most salient features of a detector system for holdup measurements. These criteria include sensitivity, energy resolution, angular resolution (for imaging technologies only), ease of use, and cost.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing an intrinsically secure information barrier for arms control verification through machine learning

Near-term solutions are needed to allow for flexible engagement in future nuclear arms control discussions. This project developed a method for implementing an information barrier (IB) on commercial systems, shortening the research and development lifecycle for warhead verification technologies while offering improved and inherently flexible capabilities. The crux of the verification challenge remains the difficulty in developing an authenticatable IB which prevents sensitive host country information from inadvertent transmission to an inspector. Many concepts for IB’s rely on dedicated “trusted” processor modules developed with dedicated custom radiation detection systems and associated algorithms. Without a priori knowledge of the treaty item, the parameter space for measurements can be nearly infinite and robustness against spoofing without the ability to view sensitive data is key. This project has produced an unclassified framework capable of ingesting data from common gamma detectors and identifying the presence of weapons grade nuclear material at over 90% accuracy.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

GADRAS-DRF Enhancements for Safeguards – Custom Peak Fitting to Enhance Model Fitting and Isotopics

One major software update was accomplished within the Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) package. This update allows users to adjust individual peak fits for use in subsequent analysis processes within GADRAS-DRF. A graphical user interface (GUI) was implemented so users can see the effect of their fit adjustments on the spectrum. This new feature will enhance the capability of the previously funded auto-enrichment and peak-based 1D model fit feature that was implemented in FY23 (Fiscal Year). Isotopic analysis was performed using M400 data obtained from uranium standards and the isotopic assessment is given with and without manual peak adjustments.

07 ISOTOPE AND RADIATION SOURCES↗

Uncertainty Quantification in GADRAS Inverse Modeling

The Gamma Detector Response and Analysis Software (GADRAS) package includes an inverse modeling tool that is helpful in identifying characteristics of unknown radioactive materials. Traditionally, uncertainties in this analysis were derived solely from measurement data quality and the fit of synthetic spectra. This paper aims to rigorously quantify additional sources of uncertainty, focusing on uncertainties arising from measurements being analyzed, Detector Response Function (DRF) characterization, and DRF extrapolation. Applying these findings to the BeRPBall benchmark data set, we demonstrated the impact of these uncertainties on plutonium and polyethylene estimates. The results underscore the importance of incorporating diverse uncertainty sources to enhance the accuracy and reliability of GADRAS’s inverse modeling capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Special Nuclear Geometric Modeling

This report is a summary of our summer interns project that focused on investigating the usefulness of the Gamma Detector Response and Analysis Software (GADRAS) into the Material Control & Accountability (MC&A) Measurements Team. The project's findings highlight the advantages of using GADRAS and demonstrate its value in improving the MC&A Measurements Team's analytical capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Behavioral Robotics Approach to Radiation Mapping Using Adaptive Sampling

Radiation mapping is a desirable task to automate because of the inherent risks involved and its tedious nature. A novel system was designed to address this by combining various existing technologies, utilizing behavior-based robotics and Bayesian optimization. The system uses a quadruped robot equipped with a manipulator and gamma detector to take measurements at locations that are selected based on the uncertainty of a surrogate model used to estimate the true radiation field. The robot uses input from the world with depth cameras to avoid collisions with the robot’s body, and unreachable points for the end effector are addressed by both allowing for a soft collision with the environment to occur, prompting the system to abandon that point, and varying the exploration tendency of the optimization based on consecutive collisions. This approach provides unique traversability and adaptability over other strategies in the literature. Experiments were performed by placing a Cesium-137 source on the ground and varying geometric setups and an optimization parameter demonstrating the adaptability to diverse environments and the increased robustness resulting from the designed behavior. The results additionally demonstrate that dynamically adjusting the optimization algorithm’s exploration tendency based on the arm’s collision history improves the system’s ability to navigate cluttered environments and construct accurate radiation maps without getting stuck in unreachable areas.

Adams, Joel↗