Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency response control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multi-frequency electrical impedance tomography

Apparatus includes a plurality of geological subsurface electrical line sensors spaced apart from each other proximate a predetermined geological subsurface region of interest, with at least one of the electrical line sensors situated as a line source to produce a multi-frequency electrical impedance tomography source signal, and with at least one of the electrical line sensors situated as a line detector to receive the multi-frequency electrical impedance tomography response signal associated with the source signal that propagates through the predetermined geological subsurface region of interest, and a controller including a processor and a memory configured with instructions that, when executed by the processor, cause the processor to determine an electrical mapping over the predetermined geological subsurface region of interest based on the multi-frequency electrical impedance tomography source signal, response signal, and the spatial positions of the geological subsurface electrical line sensors.

Karra, Satish↗

Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads

High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distinct Seasonality in Aerosol Responses to Emission Control Over Northern China

Despite intensive research exploring how aerosols respond to emission control over Northern China, efforts mostly focus on the environmental benefit, especially in winter. Here we found that unlike the most substantial PM 2.5 concentration reduction in winter, aerosol optical depth (AOD) declines more than 2 times faster in summer, causing an increase in aerosol radiative effects of 1.2 (5.7)Wm -2 on all-sky (clear-sky) conditions over 2013–2019 and largely shaping the climate impact. Low-level aerosols are shown to be the prime contributor under the synergetic effects of aerosol composition and ambient relative humidity (RH). The dominance of the highly hygroscopic sulfate combined with high RH enables a strong extinction efficiency of the reduced summertime aerosols, while the insignificant AOD decline in wintertime result from the dominance of organic aerosols with weak hygroscopicity, and is further offset by the increased frequencies of extremely high RH. We show the environmental and climatic responses of aerosols to emission control exhibit distinctively different seasonality.

54 ENVIRONMENTAL SCIENCES↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗

Inertia Emulation Control using Demand Response via 5G Communications

Building energy equipment is moving rapidly towards Internet of Things (IoT)-driven devices to provide consumer connectivity and device management. These device-level interfaces along with 5G communications will be leveraged to develop control architectures to engage a large number of monitoring and control devices and provide real-time and reliable energy services. Emerging 5G networks have high potential to provide the communication technology for demand response, with fast transfer speed, high reliability, and high number of connections. Guaranteed inertial response to limit frequency fluctuations is one of the main challenges in modern power systems due to the increased penetration of renewable generation, and it is largely affected by communication delays and packet losses. This paper analyzes inertial response and rate of change of frequency in a power system model with inverter-interfaced air conditioners. The control loop considers time delays and packet losses to show the need to switch to 5G networks in future smart grids.

Morovati, Samaneh↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Background cancellation for frequency-selective quantum sensing

A key challenge in quantum sensing is the detection of weak time dependent signals, particularly those that arise as specific frequency perturbations over a background field. Conventional methods usually demand complex dynamical control of the quantum sensor and heavy classical post-processing. We propose a quantum sensor that leverages time independent interactions and entanglement to function as a passive, tunable, thresholded frequency filter. By encoding the frequency selectivity and thresholding behavior directly into the dynamics, the sensor is responsive only to a target frequency of choice whose amplitude is above a threshold. This approach circumvents the need for complex control schemes and reduces the post-processing overhead.

Puig, Ricard [Los Alamos; Ecole Polytechnique, Lau↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

A Trade-Off Study Between the Primary and Transient Responses of Grid-Forming Inverters

The control parameters of the grid-forming (GFM) inverter-based resources (IBRs) directly impact power system dynamics. The primary control requires the GFM inverter to balance generation and load. It is also preferred that a GFM inverter maintain the terminal frequency after a power system fault. In this paper, we investigate the trade-off between the primary control objective and the transient response. To quantify the transient performance of the GFM inverter, we introduce a new real-time transient stability index (TSI). This index plays a crucial role in our investigation, as it allows us to compare the performance trade-offs of different sets of GFM control parameters.

Lin, Xuheng↗

Control of energy storage to reduce electric power system off-nominal frequency deviations

A hybrid power generation system is formed by the combination of an energy storage system (ESS) and a rotating synchronous power generator (SPG). Energy is stored in or released from the ESS in response to measurements of the at least one angle parameter, selected from rotor, torque, or power angle of the SPG, to provide active frequency damping of electrical power output. The control of ESS energy exchange increases the stabilizing impact of the SPG inertia on the frequency of electricity in an electrical network or power grid. The hybrid power generation system can have an effective equal area criterion for stability limit that is greater than that of the SPG operating without the ESS. The hybrid power generation system can enable the electrical network to have a greater proportion of variable or distributed energy resource (DER) power generation systems without otherwise exceeding stability limits.

Vartanian, Charles K.↗

Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. Here, we discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64–0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x /Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature.

47 OTHER INSTRUMENTATION↗

Real-Time Wave Energy Converter Control Using Instantaneous Frequency

Wave Energy Converters (WECs) rely on effective Power Take-Off (PTO) control strategies to maximize energy absorption under dynamic sea conditions. Traditional hydrodynamic modeling techniques may require computationally intensive convolution calculations, making real-time control implementation challenging. This paper presents an alternative approach by leveraging instantaneous frequency estimation to dynamically adjust PTO damping in response to varying wave frequencies. Two real-time frequency estimation methods are explored: the Hilbert Transform (HT) and Phase-Locked Loop (PLL). The Hilbert Transform method provides accurate frequency tracking but introduces a delayed response due to its dependence on causal data. Conversely, the PLL approach demonstrates strong potential in frequency tracking but requires careful gain tuning, particularly in complex sea states. Comparative evaluations across multiple test cases—including sinusoidal variations, amplitude steps, frequency step changes, and real-world JONSWAP spectrum waves—highlight the strengths and limitations of each method. The two different PTO control techniques across the various frequency estimation methods were tested under real-sea states using a state-space model of a point-absorbing Wave Energy Converter. The Capture Width Ratio (CWR) is used as a performance metric, with results showing that the HT achieves a 10.6% improvement, while the PLL estimation yields a 0.9% improvement relative to the fixed parameter control baseline. These results highlight the effectiveness of real-time frequency estimation in improving energy absorption compared to static control parameters.

WEC control↗