Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Comparison of URANS and LES predictions for the open phase of the OECD NEA CSNI fluid structure interaction CFD benchmark

The OECD NEA CSNI WGAMA CFD Task Group ran a benchmark in 2020 and 2021 to assess the predictive capabilities of coupled fluid structure interaction (FSI) CFD analysis methods. This paper presents the predictions made for the open phase of the benchmark using URANS and LES turbulence modelling approaches, and a comparison of the results to the experimental data. The benchmark comprised a channel containing two inline cylinders in cross-flow. The cylinders were fixed at one end, free at the other, and had measured resonant frequencies and damping properties. The URANS modelling used ANSYS Fluent 2-way coupled to ANSYS Mechanical. The LES modelling used Nek5000, 1-way coupled to Diablo. Comparisons with cross-channel velocity profiles are presented, both for the mean flow and its RMS. Comparisons are also made to the frequency spectra for point measurements of fluid velocity and pressure, and for the accelerations of the free end of each cylinder. URANS predicts the average velocity profiles relatively well, and is able to predict the velocity and acceleration spectra at the shedding frequency. However, the frequency content at the 4th harmonic of the shedding frequency is low in the URANS flow fields, and so does not excite accelerations at the resonant frequency of the cylinders. LES makes better predictions of the average profiles, and the velocity spectra agree well at both the shedding frequency and at higher frequencies. In conclusion, the 1-way coupled LES results show good agreement for acceleration spectra.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wide bandwidth frequency-domain thermoreflectance: Volumetric heat capacity, anisotropic thermal conductivity, and thickness measurements

A frequency-domain thermoreflectance (FDTR) system with a frequency range of 1 Hz to 75 MHz is presented. The wide bandwidth of pump modulation frequency enables enhanced simultaneous thermophysical property characterization of bulk and thin-film materials. The wide bandwidth FDTR system is demonstrated with simultaneous measurements of in-plane and cross-plane thermal conductivities of sapphire and muscovite mica, thickness and thermal conductivity of gold/titanium thin films, and isotropic thermal conductivity and volumetric heat capacity of lithium niobate and silicon. Thermophysical properties measured with FDTR are compared to literature values or independent measurements for verification. Finally, at low frequencies, a negligible error was achieved in the numerical integration of the heat diffusion equation with a Gauss–Legendre quadrature method solved with 400 integration points and an upper integration limit of 16weff, where weff is the effective pump–probe 1/e2 radius.

Ziade, Elbara (ORCID:0000000249020497)↗

Photonic circuits for laser stabilization with integrated ultra-high Q and Brillouin laser resonators

The integration of stabilized lasers, sources that generate spectrally pure light, will provide compact, low-cost solutions for applications including quantum information sciences, precision navigation and timing, metrology, and high-capacity fiber communications. We report a significant advancement in this field, demonstrating stabilization of an integrated waveguide Brillouin laser to an integrated waveguide reference cavity, where both resonators are fabricated using the same CMOS-compatible integration platform. We demonstrate reduction of the free running Brillouin laser linewidth to a 292 Hz integral linewidth and carrier stabilization to a 4.9 × 10 –13 fractional frequency at 8 ms reaching the cavity-intrinsic thermorefractive noise limit for frequencies down to 80 Hz. We achieve this level of performance using a pair of 56.4 x 10 6 quality factor Si 3 N 4 waveguide ring-resonators that reduce the high-frequency noise by the nonlinear Brillouin process and the low-frequency noise by Pound–Drever–Hall locking to the ultra-low loss resonator. These results represent an important step toward integrated stabilized lasers with reduced sensitivity to environmental disturbances for atomic, molecular, and optical physics (AMO), quantum information processing and sensing, and other precision scientific, sensing, and communications applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practical procedures for sensor quality assessment

Sensors are increasingly deployed for process monitoring and control. These produce on-line measurements at a high frequency, in parallel with low-frequency laboratory measurements. Compared to laboratory practices, sensor data quality assessment and control practices are far less structured at most utilities. This leads to inaccurate sensor data with unknown uncertainty factors.This chapter shows how to establish standard operating procedures (SOPs) to support sensor data quality assessment and control and subsequent maintenance actions by producing relevant sensor metadata. Furthermore, SOPs are provided for the most commonly used wastewater quality sensors, inspired by utility and academic best practices. This chapter builds on definitions provided in Chapter 3 and provides additional definitions specifically related to sensors maintenance. Chapter 6 complements the methods in this chapter, which are based on reference measurements, with data-analytical techniques.

Alferes, Janelcy↗

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Local modeling for FRF estimation with noisy input measurements

The frequency response function (FRF) is an essential means by which dynamic systems are qualified. In recent years, local modeling approaches have been extensively researched and shown to significantly outperform traditional FRF estimators. However, the standard local modeling approach assumes a perfectly-known system input, which results in biased FRF estimates in the presence of input noise. This paper derives a simple adjustment that can be used to improve FRF estimation for systems subjected to random excitation with noisy input data. This improvement can be implemented with little modification to standard local modeling algorithms and with little additional computational burden. The adjustment is coupled with a model selection procedure to avoid underfitting and overfitting. In conclusion, the methods presented in this paper are validated on a simulation, and they are shown to reduce bias due to input noise.

47 OTHER INSTRUMENTATION↗

Molecular-Level Insights into the NMR Relaxivity of Gadobutrol Using Quantum and Classical Molecular Simulations

MRI is an indispensable diagnostic tool in modern medicine; however, understanding the molecular-level processes governing NMR relaxation of water in the presence of MRI contrast agents remains a challenge, hindering the molecular-guided development of more effective contrast agents. By using quantum-based polarizable force fields, the first-of-its-kind molecular dynamics (MD) simulations of Gadobutrol are reported where the 1 H NMR longitudinal relaxivity r 1 of the aqueous phase is determined without any adjustable parameters. The MD simulations of r 1 dispersion (i.e., frequency dependence) show good agreement with measurements at frequencies of interest in clinical MRI. Importantly, the simulations reveal key insights into the molecular level processes leading to r 1 dispersion by decomposing the NMR dipole–dipole autocorrelation function G(t) into a discrete set of molecular modes, analogous to the eigenmodes of a quantum harmonic oscillator. The molecular modes reveal important aspects of the underlying mechanisms governing r 1 , such as its multiexponential nature and the importance of the second eigenmodal decay. By simply analyzing the MD trajectories on a parameter-free approach, the Gadobutrol simulations show that the outer-shell water contributes ∼50% of the total relaxivity r 1 compared to the inner-shell water, in contrast to simulations of (nonchelated) gadolinium-aqua where the outer shell contributes only ∼15% of r 1 . The deviation between simulations and measurements of r 1 below clinical MRI frequencies is used to determine the low-frequency electron-spin relaxation time for Gadobutrol, in good agreement with independent studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniature quantum frequency standard based on the phenomenon of coherent population trapping in vapours of {sup 87}Rb atoms

We report the results of the development and production of a quantum frequency standard (QFS) based on the coherent population trapping (CPT) resonance observed on the D{sub 1} absorption line of {sup 87}Rb atoms. The effect of various physical factors on the QFS frequency is studied, and the optimal physical parameters of the device to attain the best frequency stability are determined. The measured relative frequency instability (Allan deviation) is ∼9 × 10{sup −12} for the averaging time of 1 s, 3 ×10{sup −13} for 1000 s, and 1.5 ×10{sup −12} for 24 hours. For a volume of 60 cm{sup 3}, the power consumption of the entire device is 300 mW. The designed QFS can be used in a new-generation satellite navigation systems with increased accuracy and reliability, as well as for solving a number of other problems of science and technology. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probe measurements of electric field and electron density fluctuations at megahertz frequencies using in-shaft miniature circuits

In this work, a four-tip electrostatic probe is constructed to measure high-frequency (0.1–10 MHz) fluctuations in both the electric field (one component) and electron density in a laboratory plasma. This probe also provides data for the local electron temperature and density. Circuits for high-frequency measurements are fabricated on two miniature boards, which are embedded in the probe shaft, near the tips to minimize the pickup of common-mode signals. The amplitude and phase response of two circuits to sinusoidal test signals are measured and compared with results from modeling. For both circuits, the phase shift between input and output signals is relatively small (<30°). The performance of the probe is verified in a high-density (~10 13 cm –3 ) and low-temperature (≲10 eV) plasma. The probe successfully measures high-frequency (~2 MHz) fluctuations in the electric field and density, which are associated with lower hybrid drift waves. This probe can provide information on the wave-associated anomalous drag, which can be compared with the classical resistivity.

47 OTHER INSTRUMENTATION↗

Low-Frequency Oscillations in Optical Measurements of Metal-Nanoparticle Vibrations

Time-resolved optical measurements of vibrating metal nanoparticles have been used extensively to probe the ultrafast mechanical properties of the nanoparticles and of the surrounding liquid, but nearly all investigations so far have been limited to the linear regime. Herein, we report the observation of a low-frequency oscillating signal in transient-absorption measurements of nanoparticles with octahedral gold cores and cubic silver shells; the signal appears at the difference of two mechanical vibrational frequencies in the particles, suggesting a nonlinear mixing process. We tentatively attribute this proposed mixing to a nonlinear coupling between a vibrational mode of the nanoparticle and its optical-frequency plasmon resonance. The optimization of this nonlinear transduction may enable high-efficiency opto-mechanical frequency mixing in the GHz-THz frequency regime.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

AmeriFlux FLUXNET-1F CA-Ca3 British Columbia - Pole sapling Douglas-fir stand

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-Ca3 British Columbia - Pole sapling Douglas-fir stand. This is the FLUXNET version of the carbon flux data for the site CA-Ca3 British Columbia - Pole sapling Douglas-fir stand produced by applying the standard ONEFlux (1F) software. Site Description - Site: 1988 Harvested Douglas Fir (Pole-sapling); Tower Type 10" triangular tower; Latitude/Longitude 49.53462N -124.90044W (GPS survey, 2003. Coordinates updated/corrected May, 2006); Elevation approx. 170 m; Mean Air Temp. (for the growing season) 9.7 C *; Mean Annual Precipitation 1179 mm *; Date Operations Began: September 2001; Frequency of EC Measurements 20 Hz; Frequency of Other Met. Sensors 4 sec, year round; Soil Respiration Measurements Periodically during growing season using portable system in 2002; * 30-yr climate normals from the Comox Airport

Black, T. Andrew [University of British Columbia, ↗

AmeriFlux FLUXNET-1F CA-Ca1 British Columbia - 1949 Douglas-fir stand

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-Ca1 British Columbia - 1949 Douglas-fir stand. This is the FLUXNET version of the carbon flux data for the site CA-Ca1 British Columbia - 1949 Douglas-fir stand produced by applying the standard ONEFlux (1F) software. Site Description - 1949 Douglas-fir stand; Tower Type 20" triangular tower; Latitude/Longitude 49.86725N 125.33360W (GPS survey, 2003. Coordinates updated/corrected May, 2006); Elevation 320 m; North-east facing terrain, 5-10 deg slope; Mean Air Temp. 8.3 °C* ; Mean Annual Precipitation 1461 mm * ; Date Operations Began June 1997 ; Frequency of EC Measurements 20.83 Hz; Frequency of Other Met. Sensors 1 - 4 sec, year round ; Soil Respiration Measurements 30 min., automated soil respiration system in 2000, periodically during growing season using portable system in 2002 ; * 1998-2001 averages from the 1948 Douglas-fir stand meteorological tower

Black, T. Andrew↗

Radio Frequency Transients Correlated with Electron Flux Measured On-Board the STP-Sat6

We analyzed transient electromagnetic signatures, referred to as spacecraft environment discharges (SEDs) or on-board discharges (OBDs), and the in-situ particle environment simultaneously measured by the Radio Frequency Sensor (RFS) and the Space and Atmospheric Burst Reporting System Z-plasma spectrometer (SABRS-ZPS), respectively. These sensors are on-board the U.S. Department of Defense Space Test Program Satellite 6 (STP-Sat6) in geostationary orbit. Radio frequency signatures of SEDs on STP-Sat6 have relatively high peak amplitudes; they often caused amplitude-saturation in the so-called high band (120–140 MHz frequency range) of the RFS likely due to the proximity of their source to the RFS’s dipole antennas. We examined the occurrence rate of SEDs reported by the RFS and its temporal relationship to electron flux in the 7.9–12.2 keV range. Peaks in SED count rates were time-correlated with peaks in electron flux. The electron-flux peaks appeared to lead the SED count rate peaks by 24–45 min for the 7.9–12.2 keV energies. This indicates that incidence of electrons at this relatively low-energy range likely resulted in ramping up of the charging of the spacecraft leading to periods of high occurrence rates of discharges in and around the spacecraft.

54 ENVIRONMENTAL SCIENCES↗

Searching For Transiting Planets Around Halo Stars. I. Sample Selection and Validation

By measuring the elemental abundances of a star, we can gain insight into the composition of its initial gas cloud—the formation site of the star and its planets. Planet formation requires metals, the availability of which is determined by the elemental abundance. In the case where metals are extremely deficient, planet formation can be stifled. To investigate such a scenario requires a large sample of metal-poor stars and a search for planets therein. This paper focuses on the selection and validation of a halo star sample. We select ~17,000 metal-poor halo stars based on their Galactic kinematics, and confirm their low metallicities ([Fe/H] < -0.5), using spectroscopy from the literature. Furthermore, we perform high-resolution spectroscopic observations using LBT/PEPSI and conduct detailed metallicity ([Fe/H]) analyses on a sample of 13 previously-known halo stars that also have hot kinematics. We can use the halo star sample presented here to measure the frequency of planets and to test planet formation in extremely metal-poor environments. The result of the planet search and its implications will be presented and discussed in a companion paper by Boley et al.

47 OTHER INSTRUMENTATION↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetotropic susceptibility

The magnetotropic susceptibility is the thermodynamic coefficient associated with the rotational anisotropy of the free energy in an external magnetic field and is closely related to the magnetic susceptibility. It emerges naturally in frequency-shift measurements of oscillating mechanical cantilevers, which are becoming an increasingly important tool in the quantitative study of the thermodynamics of modern condensed-matter systems. Here, in this work, we discuss the basic properties of the magnetotropic susceptibility as they relate to the experimental aspects of frequency-shift measurements, as well as to the interpretation of those experiments in terms of the intrinsic properties of the system under study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PNNL ARENA Cable Motor Test Bed Update

A major focus of the Light Water Reactor Sustainability (LWRS) Cable Nondestructive Examination (NDE) 2021 research is to acquire new equipment and integrate it with existing NDE instruments for a cable motor test bed which has been dubbed the Accelerated and Real Time Experimental Nodal Analysis or “ARENA”. All the primary components have been received and are being staged in the 2410 Stevens building on PNNL’s Richland campus. Building modifications to support a plug-in 480VAC receptacle have been completed and details of the system operating procedure (SOP) are in review. The approved SOP is required before the system is energized but is expected before July 2021. The ARENA system will support planned cable tests for 2021 and beyond that cannot conveniently be performed with on-site installations of cable test equipment including: (1) NDE Tests including Frequency Domain Reflectometry (FDR), Time Domain Reflectometry (TDR), Tan Delta (TD) Impedance measurements, Low Frequency Dielectric Spectroscopy (DS) measurements, standard multi-meter resistance checks, withstand tests and other bulk and distributed tests from the instrument panel with and without motors connected. (2) Online energized live wire tests using partial discharge instruments and LIVE-WIRE spread-spectrum TDR instruments. (3) Cable tests with partially submerged cable segments (including ability to submerge live cable segments). (4) Cable tests with partially or completely thermally aged segments (including ability to expose energized cable segments to thermal aging and use online monitoring instruments to monitor cable performance. (5) Ability to introduce low resistance simulations of connector or splice faults to off-line and on-line instrument setups.

42 ENGINEERING↗