Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluid flow measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

In-Flow Acoustic Sensor

An acoustic sensor for measuring acoustic waves contained in fluid flow flowing over the sensor is introduced. The acoustic sensor reduces any unwanted self-noise associated with the flowing fluid by providing a nose cone having proper aerodynamic properties and by positioning the diaphragm of a microphone of the sensor at a location where any unwanted noise is at a relatively low level. The nose cone has a rounded, blunt or even sharp tip neither of which creates any major disturbances in the flowing fluid which it intercepts.

Allen, Christopher S.↗

Meta-uncertainty for particle image velocimetry

Uncertainty quantification for Particle Image Velocimetry (PIV) is critical for comparing experimentally measured flow fields with Computational Fluid Dynamics (CFD) results, and model design and validation. However, PIV features a complex measurement chain with coupled, non-linear error sources, and quantifying the uncertainty is challenging. Multiple assessments show that none of the current methods can reliably measure the actual uncertainty across a wide range of experiments, and estimates can vary. Because the current methods differ in assumptions regarding the measurement process and calculation procedures, it is not clear which method is best to use for an experiment where the error distribution is unknown. To address this issue, we propose a method to estimate an uncertainty method's sensitivity and reliability, termed the Meta-Uncertainty. The novel approach is automated, local, and instantaneous, and based on perturbation of the recorded particle images. We developed an image perturbation scheme based on adding random unmatched particles to the interrogation window pair considering the signal-to-noise (SNR) of the correlation plane. Each uncertainty scheme's response to several trials of random particle addition is used to estimate a reliability metric, defined as the rate of change of the inter-quartile range (IQR) of the uncertainties with increasing levels of particle addition. We also propose applying the meta-uncertainty as a weighting metric to combine uncertainty estimates from individual schemes, based on ideas from the consensus forecasting literature. We use planar and stereo PIV measurements across a range of canonical flows to assess the performance of the uncertainty schemes. Further, a novel method is introduced to assess an uncertainty scheme's performance based on a quantile comparison of the error and uncertainty distributions, generalizing the current method of comparing the RMS of the two distributions. Here, the results show that the combined uncertainty method outperforms the individual methods, and this work establishes the meta-uncertainty as a useful reliability assessment tool for PIV uncertainty quantification.

47 OTHER INSTRUMENTATION↗

Granular Material Flows with Interstitial Fluid Effects

The research focused on experimental measurements of the rheological properties of liquid-solid and granular flows. In these flows, the viscous effects of the interstitial fluid, the inertia of the fluid and particles, and the collisional interactions of the particles may all contribute to the flow mechanics. These multiphase flows include industrial problems such as coal slurry pipelines, hydraulic fracturing processes, fluidized beds, mining and milling operation, abrasive water jet machining, and polishing and surface erosion technologies. In addition, there are a wide range of geophysical flows such as debris flows, landslides and sediment transport. In extraterrestrial applications, the study of transport of particulate materials is fundamental to the mining and processing of lunar and Martian soils and the transport of atmospheric dust (National Research Council 2000). The recent images from Mars Global Surveyor spacecraft dramatically depict the complex sand and dust flows on Mars, including dune formation and dust avalanches on the slip-face of dune surfaces. These Aeolian features involve a complex interaction of the prevailing winds and deposition or erosion of the sediment layer; these features make a good test bed for the verification of global circulation models of the Martian atmosphere.

Hunt, Melany L.↗

Low-temperature Brayton radiator performance in a variable-sink-temperature environment

An analysis of the performance of a low-temperature Brayton space radiator is presented. The cylindrical radiator with circumferential tubes was subjected to an equivalent sink temperature environment that varied along the fluid flow path. The radiator performance, as measured by fluid outlet temperature, was found to be dependent on the orbital position and the location of the radiator inlet relative to the sink temperature environment. An approximate dynamic analysis of sun-shade variations in performance is included.

Bien, D. B.↗

Cold-air performance of compressor-drive turbine of Department of Energy upgraded automobile gas turbine engine. 1: Volute-manifold and stator performance

The aerodynamic performance of the inlet manifold and stator assembly of the compressor drive turbine was experimentally determined with cold air as the working fluid. The investigation included measurements of mass flow and stator-exit fluid torque as well as radial surveys of total pressure and flow angle at the stator inlet and annulus surveys of total pressure and flow angle at the stator exit. The stator-exit aftermixed flow conditions and overall stator efficiency were obtained and compared with their design values and the experimental results from three other stators. In addition, an analysis was made to determine the constituent aerodynamic losses that made up the stator kinetic energy loss.

Roelke, R. J.↗

A System for Measurement of Convection Aboard Space Station

A simple device for direct measurement of buoyancy driven fluid flows in a low-gravity environment is proposed. A system connecting spacecraft accelerometers data and results of thermal convection in enclosure measurements and numerical simulations is developed. This system will permit also to evaluate the low frequency microacceleration component. The goal of the paper is to present objectives and current results of ground-based experimental and numerical modeling of this convection detector.

Bogatyrev, Gennady P.↗

Fluid dynamic studies on scattering aerosol and its generation for application as tracer particles in supersonic flow measurements utilizing laser Doppler velocimeter

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited oscillatory fluid velocity field and by comparing the ratio of particle velocity amplitude to the fluid velocity amplitude as a function of particle size and the frequency of oscillation. Particle velocity was measured by using a differential laser Doppler velocimeter. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. It is indicated that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗

Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options

An advanced reactant pressure regulator with an internal ejector reactant circulation pump has been developed to support NASA's future fuel cell power systems needs. These needs include reliable and safe operation in variable-gravity environments, and for exploration activities with both manned and un manned vehicles. This product was developed for use in Proton Exchange Membrane Fuel Cell (PEMFC) power plant reactant circulation systems, but the design could also be applied to other fuel cell system types, (e.g., solid-oxide or alkaline) or for other gas pressure regulation and circulation needs. The regulator design includes porting for measurement of flow and pressure at key points in the system, and also includes several fuel cell system integration options. NASA has recognized ejectors as a viable alternative to mechanical pumps for use in spacecraft fuel cell power systems. The ejector motive force is provided by a variable, high-pressure supply gas that travels through the ejector s jet nozzle, whereby the pressure energy of the fluid stream is converted to kinetic energy in the gas jet. The ejector can produce circulation-to-consumption-flow ratios that are relatively high (2-3 times), and this phenomenon can potentially (with proper consideration of the remainder of the fuel cell system s design) be used to provide completely for reactant pre-humidification and product water removal in a fuel cell system. Specifically, a custom pressure regulator has been developed that includes: (1) an ejector reactant circulation pump (with interchangeable jet nozzles and mixer sections, gas-tight sliding and static seals in required locations, and internal fluid porting for pressure-sensing at the regulator's control elements) and (2) internal fluid porting to allow for flow rate and system pressure measurements. The fluid porting also allows for inclusion of purge, relief, and vacuum-breaker check valves on the regulator assembly. In addition, this regulator could also be used with NASA's advanced nonflow-through fuel cell power systems by simply incorporating a jet nozzle with an appropriate nozzle diameter.

Vasquez, Arturo↗

Advanced designs for fluid flow visualization

Research was carried out on existing and new designs for minimally intrusive measurement of flow fields in the Geophysical Fluid Flow Cell and the proposed Atmospheric General Circulation Experiment. The following topics are discussed: (1) identification and removal of foreign particles, (2) search for higher dielectric photochromic solutions, (3) selection of uv light source, (4) analysis of refractive techniques and (5) examination of fresnel lens applicability.

Source record↗

Mass flow sensor utilizing a resistance bridge

A mass flow sensor to be mounted within a duct and measures the mass flow of a fluid stream moving through the duct. The sensor is an elongated thin quartz substrate having a plurality of platinum strips extending in a parallel relationship on the strip, with certain of the strips being resistors connected to an excitation voltage. The resistors form the legs of a Wheatstone bridge. The resistors are spaced a sufficient distance inwardly from the leading and trailing edges of the substrate to lie within the velocity recovery region so that the measured flow is the same as the actual upstream flow. The resistor strips extend at least half-way through the fluid stream to include a substantial part of the velocity profile of the stream. Certain of the resistors detect a change in temperature as the fluid stream moves across the substrate to provide an output signal from the Wheatstone bridge which is representative of the fluid flow. A heater is located in the midst of the resistor array to heat the air as it passes over the array.

Fralick, Gustave C.↗

Advanced optical measuring systems for measuring the properties of fluids and structures

Four advanced optical models are reviewed for the measurement of visualization of flow and structural properties. Double-exposure, diffuse-illumination, holographic interferometry can be used for three-dimensional flow visualization. When this method is combined with optical heterodyning, precise measurements of structural displacements or fluid density are possible. Time-average holography is well known as a method for displaying vibrational mode shapes, but it also can be used for flow visualization and flow measurements. Deflectometry is used to measure or visualize the deflection of light rays from collimation. Said deflection occurs because of refraction in a fluid or because of reflection from a tilted surface. The moire technique for deflectometry, when combined with optical heterodyning, permits very precise measurements of these quantities. The rainbow schlieren method of deflectometry allows varying deflection angles to be encoded with colors for visualization.

Decker, A. J.↗

Capillary Pressure to Relative Permeability: Task 7.3.4 Relative Permeability Analysis Final Report

Surface tension affects all aspects of fluid flow in porous media. Through measurements of surface tension interaction under multiphase conditions, a relative permeability relationship can be determined. Relative permeability is a numerical description of the interplay between two or more fluids and the porous media they flow through. It is a critical parameter for various tools used to characterized subsurface multiphase flow systems, such as numerical simulation for oil and gas development, carbon sequestration, and groundwater contamination remediation. Therefore, it is critical to get a good statistic distribution of relative permeability in the porous media under study. Empirical relationships for determining relative permeability from capillary pressure are already well established but do not provide the needed flexibility required to match laboratory derive relative permeability relationships. By expanding the existing methods for calculating relative permeability from capillary pressure data, it is possible to create both two and three-phase relative permeability relationships. Existing laboratory-measured relative permeability data along with mercury intrusion capillary (MICP) data coupled with interfacial tension and contact angle measurements were used to determine the efficacy of this approach to relative permeability curve creation. The relative permeability relationships determined with this method were fit to existing laboratory data to elucidate common fitting parameters that were then used to create relative permeability relationships from MICP data that does not have an associated laboratory-measured relative permeability relationship.

58 GEOSCIENCES↗

Fluid Shifts

Introduction. NASA's Human Research Program is focused on addressing health risks associated with long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but now more than 50 percent of ISS astronauts have experienced more profound, chronic changes with objective structural findings such as optic disc edema, globe flattening and choroidal folds. These structural and functional changes are referred to as the visual impairment and intracranial pressure (VIIP) syndrome. Development of VIIP symptoms may be related to elevated intracranial pressure (ICP) secondary to spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to determine if a relation exists with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as any VIIP-related effects of those shifts, are predicted by the crewmember's pre-flight status and responses to acute hemodynamic manipulations, specifically posture changes and lower body negative pressure. Methods. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, and calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography; intraocular pressure; 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness; Doppler ultrasound of ophthalmic and retinal arteries and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, otoacoustic emissions). Pre- and post-flight, acute head-down tilt will induce cephalad fluid shifts, whereas lower body negative pressure will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. Discussion. Ten subjects have consented to participate in this experiment, including the recent One-Year Mission crewmembers, who have recently completed R plus180 testing; all other subjects have completed pre-flight testing. Preliminary results from the One-Year Mission crewmembers will be presented, including measures of ocular structure and function, vascular dimensions, fluid distribution, and non-invasive estimates of intracranial pressure.

Stenger, M. B.↗

Optical measurements and tests performed in a low-gravity environment

Shadowgraph and schlieren techniques have been used on board the NASA KC-135 low-gravity simulation aircraft to measure gravity-related fluid flow occurring in various experimental configurations. These configurations included cooled and solidified ammonium chloride and water, electrodeposited cobalt in CoSO4 solution, and immiscible and crystal melt solutions. Hardware tests have also been performed for such critical optical system components as lasers and spatial filters to determine their performance and operation under low-gravity conditions. These test results will be used in the design of the various future Shuttle experiments which will utilize advanced optical measurement techniques. The design and configuration of the optical systems used to make these measurements and tests are presented, and the performance and operation of these systems and their components under low-gravity conditions are discussed. Some preliminary results are included.

Owen, R. B.↗

Velocity Profiling of a Gas–Solid Fluidized Bed Using Electrical Capacitance Volume Tomography

In this study, a method of producing velocity profile maps from electrical capacitance volume tomography (ECVT) measurements by reconstructing displacement from measured changes in capacitance is developed and applied to fluidized bed systems. The mapping of the reconstruction leverages the gradient of the sensitivity distribution of the ECVT sensor to circumvent the need for image cross correlation techniques. Experimental data of both bubbling and slugging fluidized beds are collected in a cold flow model. Adaptation of the technique is discussed in detail, and velocity profiles are obtained for a range of gas flow rates. The produced velocity maps are compared against the established methods of cross correlation and against empirical correlations from the literature and are found to agree well in tracking slug and bubble velocity. The exception is when the tracked object is large relative to the ECVT sensor dimensions, a scenario that can be avoided through proper sensor design. The quantities of average velocity, momentum, and solid and gas volume fraction are derived from the image and velocity profiles. The results demonstrate and extend the power of ECVT as a measurement tool for the study and monitoring of gas–solid fluidized beds by providing a computationally cheaper alternative to 3-D cross correlation for deriving velocity profiles.

47 OTHER INSTRUMENTATION↗

An integrated approach to derive relative permeability from capillary pressure

Surface tension affects all aspects of fluid flow in porous media. Through measurements of surface tension interaction under multiphase conditions, a relative permeability curve can be determined. Relative permeability is a numerical description of the interaction between two or more fluids and the porous media. It is a critical parameter for various tools that characterize subsurface multiphase flow systems, such as numerical simulation for carbon sequestration, oil and gas development, and groundwater contamination remediation. Therefore, it is critical to get a good statistical distribution of relative permeability in the porous media under study. Empirical formula for determining relative permeability from capillary pressure are already well established but do not provide the needed flexibility that is required to match laboratory-derived relative permeability curves. By expanding the existing methods for calculating relative permeability from capillary pressure data, it is possible to create both two and three-phase relative permeability curves. Mercury intrusion capillary pressure (MICP) data from the Morrow 'B' Sandstone coupled with interfacial tension and contact angle measurements were used to create a suite of relative permeability curves. Furthermore, these curves were then calibrated to a small sample of existing laboratory curves to elucidate common fitting parameters for the formation that were then used to create relative permeability curves from MICP data that does not have an associated laboratory-measured relative permeability curve.

58 GEOSCIENCES↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗