Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flight computer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

O’Hare Airport Short-Term Ground Transportation Modal Demand Forecast Using Gaussian Processes

Here, the principal objective of this study is to analyze the spatial and temporal variation of ground transportation airport demand and provide demand forecast to inform planning capability and explore alternatives for investments to accommodate airport growth. Because of its good adaptability and strong generalization ability for dealing with high-dimensional input, small-sample, and nonlinear spatial data, Gaussian process (GP) regression is used to provide forecast estimates using data from transportation network company (TNC) trips and urban rail passengers at Chicago's O'Hare International Airport. TNC airport trips differ significantly, with three times more distance, more than twice the travel time, and half of the share requests compared with nonairport trips. This highlights the need for separate demand models. Hourly analysis of the rail service indicates that this is likely heavily used by airport workers, whereas TNC services focus on travelers because of variations in the peak demand hours. Heteroscedastic GP regression is implemented because of differences in trip variance between night and day hours. Estimates are given for weekdays and weekend trips, and the 95% confidence intervals are calculated. The introduction of flight schedule information into the models shows marginal improvements in their performance. However, fitting a GP regression becomes computationally expensive with increased sample size and the introduction of spatial components. Transportation planners and policymakers can use the results and methods implemented in this study to optimize transportation assets and provide long-range simulations of the current and future conditions in the area.

42 ENGINEERING↗

Secondary electron emission and self-consistent charge transport in semi-insulating samples

Electron beam induced self-consistent charge transport and secondary electron emission (SEE) in insulators are described by means of an electron-hole flight-drift model (FDM) now extended by a certain intrinsic conductivity (c) and are implemented by an iterative computer simulation. Ballistic secondary electrons (SE) and holes, their attenuation to drifting charge carriers, and their recombination, trapping, and field- and temperature-dependent detrapping are included. As a main result the time dependent ''true'' secondary electron emission rate {delta}(t) released from the target material and based on ballistic electrons and the spatial distributions of currents j(x,t), charges {rho}(x,t), field F(x,t), and potential V(x,t) are obtained where V{sub 0} = V(0,t) presents the surface potential. The intrinsic electronic conductivity limits the charging process and leads to a conduction sample current to the support. In that case the steady-state total SE yield will be fixed below the unit: i.e., {sigma} {eta} + {delta} < 1.

36 MATERIALS SCIENCE↗

Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in administered activity in cardiac PET studies

Background: Time-of-flight (TOF) is known to increase signal-to-noise ratio (SNR) and facilitate reductions in administered activity. Established measures of SNR gain are derived from areas of uniform uptake, which is not applicable to the heterogeneous uptake in cardiac PET images using fluoro-deoxyglucose (FDG). This study aimed to develop a technique to quantify SNR gains within the myocardium due to TOF. Methods: Reference TOF SNR gains were measured in 88 FDG oncology patients. Phantom data were used to translate reference SNR gains and validate a method of quantifying SNR gains within the myocardium from parametric images produced from multiple replicate images. This technique was applied to 13 FDG cardiac viability patients. Results: Reference TOF SNR gains of +23% ± 8.5% were measured in oncology patients. Measurements of SNR gain from the phantom data were in agreement and showed the parametric image technique to be sufficiently robust. SNR gains within the myocardium in the viability patients were +21% ± 2.8%. Conclusion: A method to quantify SNR gains from TOF within the myocardium has been developed and evaluated. SNR gains within the myocardium are comparable to those observed by established methods. This allows guidance for protocol optimization for TOF systems in cardiac PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora↗

Pilot-configurable information on a display unit

A small thin display unit that can be installed in the flight deck for displaying only flight crew-selected tactical information needed for the task at hand. The flight crew can select the tactical information to be displayed by means of any conventional user interface. Whenever the flight crew selects tactical information for display, the user interface sends a corresponding request for tactical information to a computer system. The computer system processes the request, including periodically retrieving measured current values or computing current values for the requested tactical parameters and returning those current tactical parameter values to the display unit for display.

Shafaat, Syed Tahir↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Results from the commissioning of a multi-modal endoscope for ultrasound and time of flight PET

The EndoTOFPET-US collaboration has developed a multi-modal imaging system combining Ultrasound with Time-of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200 ps FWHM and to achieve about 1 mm spatial resolution of the PET system, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying model prediction sensitivity to model-form uncertainty

Computational and mathematical models are essential to understanding complex systems and phenomena. However, when developing such models, limited knowledge and/or resources necessitates the use of simplifying assumptions. It is therefore crucial to quantify the impact of such simplifying assumptions on the reliability and accuracy of resulting model predictions. This work develops a first-of-its-kind approach to quantify the impact of physics modeling assumptions on predictions. Here, we leverage the emerging field of model-form uncertainty (MFU) representations, which are parameterized modifications to modeling assumptions, in combination with grouped Sobol’ indices to quantitatively measure an assumption’s importance. Specifically, we compute the grouped Sobol’ index for the MFU representation’s parameters as a single importance measure of the assumption for which the MFU representation characterizes uncertainty. To ensure this approach is robust to the subjective choice of how to parameterize a MFU representation, we establish bounds for the difference between sensitivity results for two different MFU representations based on differences in model prediction statistics. The capabilities associated with this approach are demonstrated on three exemplar problems: an upscaled subsurface contaminant transport problem, ablation modeling for hypersonic flight, and nuclear waste repository modeling. We found that our grouped approach is able to assess the impact of modeling assumptions on predictions and offers computational advantages over classical Sobol’ index computation while providing more interpretable results.

97 MATHEMATICS AND COMPUTING↗

Lookup tables to compute high energy cosmic ray induced atmospheric ionization and changes in atmospheric chemistry

A variety of events such as gamma-ray bursts and supernovae may expose the Earth to an increased flux of high-energy cosmic rays, with potentially important effects on the biosphere. Existing atmospheric chemistry software does not have the capability of incorporating the effects of substantial cosmic ray flux above 10 GeV. An atmospheric code, the NASA-Goddard Space Flight Center two-dimensional (latitude, altitude) time-dependent atmospheric model (NGSFC), is used to study atmospheric chemistry changes. Using CORSIKA, we have created tables that can be used to compute high energy cosmic ray (10 GeV–1 PeV) induced atmospheric ionization and also, with the use of the NGSFC code, can be used to simulate the resulting atmospheric chemistry changes. We discuss the tables, their uses, weaknesses, and strengths.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental and theoretical study of core-valence double photoionization of OCS

O 1s, C 1s, and S 2p core-valence double ionization electron spectra of the OCS molecule have been obtained experimentally by a time-of-flight photoelectron-photoelectron coincidence spectroscopy technique. In order to analyze and assign the spectral features observed, we present a protocol for computing core-valence ionization energies of such systems. The protocol is based on a restricted active space multiconfigurational self-consistent field (MCSCF) methodology with a freeze-relax procedure to guarantee a correct core-valence state root index without variational collapse. Corrections for extended dynamical correlation and core-core correlation, respectively, are made by multiconfigurational perturbation theory and by uncontracted basis set Moeller-Plesset theory. Envisioning applications to larger molecules, a spin-restricted open-shell density functional method is also applied for the lowest core-valence energies. Furthermore, cross sections through a scheme for computing multiatom Auger transitions generating core-valence holes are presented. We find that the procedure outlined is capable of deriving the energy onset of core-valence ionization within a fraction of an eV and that assignments can be made of the most salient spectral features.

74 ATOMIC AND MOLECULAR PHYSICS↗

Computational Characterization and Boundary Condition Models of a Jet Interaction Fluidic Oscillator

Fluidically oscillating jet actuators that generate sweeping jets when supplied with a pressurized fluid have been used to mitigate separation and reduce drag in a range of flow control applications. Their implementation in future flight vehicles would require fundamental understanding and accurate predictive techniques of the physics of their internal flow and jet formation. The present investigations focus on high-fidelity, time-accurate simulations to characterize the flow physics of the actuator in quiescent conditions. An important element of the present simulations is to demonstrate the ability of the computational fluid dynamics (CFD) solver to predict the jet characteristics and provide a basis for the development of improved boundary conditions (BC) without entirely resolving the geometrical features of the fluidic device. The CFD-predicted oscillation frequencies of the engendered jets were found to be in excellent agreement with experiments, even on two-dimensional meshes. The study revealed that three-dimensional simulations are required to capture some of the flow features of the sweeping jet such as the double peak in time-averaged velocity distributions downstream of the actuator’s orifice that were measured in experiments. Furthermore, several approaches for modeling the actuator were implemented and assessed in quiescent conditions. The evaluation of a boundary condition at the device throat, based on the phase-averaged flow variables, provides the basis for devising surface-based boundary conditions. The influence and necessity of including turbulent characteristics as part of the boundary conditions have also been identified.

42 ENGINEERING↗

Effect of time-of-flight and point spread function modeling on detectability of myocardial defects in PET

Purpose: A study was designed to investigate the impact of time-of-flight (TOF) and point spread function (PSF) modeling on the detectability of myocardial defects. Methods: Clinical FDG-PET data were used to generate populations of defect-present and defect-absent images. Defects were incorporated at three contrast levels, and images were reconstructed by ordered subset expectation maximization (OSEM) iterative methods including ordinary Poisson, alone and with PSF, TOF, and PSF+TOF. Channelized Hotelling observer signal-to-noise ratio (SNR) was the surrogate for human observer performance. Results: For three iterations, 12 subsets, and no postreconstruction smoothing, TOF improved overall defect detection SNR by 8.6% as compared to its non-TOF counterpart for all the defect contrasts. Due to the slow convergence of PSF reconstruction, PSF yielded 4.4% less SNR than non-PSF. For reconstruction parameters (iteration number and postreconstruction smoothing kernel size) optimizing observer SNR, PSF showed larger improvement for faint defects. The combination of TOF and PSF improved mean detection SNR as compared to non-TOF and non-PSF counterparts by 3.0% and 3.2%, respectively. Conclusions: For typical reconstruction protocol used in clinical practice, i.e., less than five iterations, TOF improved defect detectability. In contrast, PSF generally yielded less detectability. For large number of iterations, TOF+PSF yields the best observer performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of Coulomb effects on the resolving power of multireflection mass-spectrometer systems

General theoretical approaches to the modelling of Coulomb effects in short ion bunches, developed previously by the authors, are applied in this paper to the calculation of multireflection mass-spectrometer systems. A separate module of the MASIM 3D applied software package is designed. An adaptive computational procedure for calculating the 'mirror potential' induced by an ion bunch on the surface of field-forming electrodes is proposed. The dynamics of ion bunches in a time-of-flight reflectron-type mass analyser is calculated and the limitations on the resolving power, caused by resonant Coulomb effects of self-bunching and coalescence in the groups of particles with close masses, are revealed on the basis of numerical experiments. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Navy Flight Testing Environmental Data Transfer Format Standard

This document outlines key elements of a data format standard for transferring Navy environmental flight test data between members of the Collaborative Environments Characterization Working Group (CECWG). The plan applies to measured data as well as analyzed or processed data. This plan is intended to foster a more productive collaboration between CECWG members by providing a common interface format such that each agency only has to receive and transmit data in one common format. Ideally, each agency is thus only responsible for translating formats between the native format of each agency’s respective database of flight measurements and this common data transfer format.

97 MATHEMATICS AND COMPUTING↗

Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications

Purpose: Metal package photomultiplier tubes (PMTs) with a metal channel dynode structure have several advanced features for devising such time-of-flight (TOF) and high spatial resolution positron emission tomography (PET) detectors, thanks to their high packing density, large effective area ratio, fast time response, and position encoding capability. Here, we report on an investigation of new metal package PMTs with high quantum efficiency (QE) for high-resolution PET and TOF PET detector modules. Methods: The latest metal package PMT, the Hamamatsu R11265 series, is served with two kinds of photocathodes that have higher quantum efficiency than normal bialkali (typical QE ≈ 25%), super bialkali (SBA; QE ≈ 35%), and ultra bialkali (UBA; QE ≈ 43%). In this study, the authors evaluated the performance of the new PMTs with SBA and UBA photocathodes as a PET detector by coupling various crystal arrays. They also investigated the performance improvements of high QE, focusing in particular on a block detector coupled with a lutetium-based scintillator. A single 4 × 4 × 10 mm{sup 3} LYSO, a 7 × 7 array of 3 × 3 × 20 mm{sup 3} LGSO, a 9 × 9 array of 1.2 × 1.2 × 10 mm{sup 3} LYSO, and a 6 × 6 array of 1.5 × 1.5 × 7 mm{sup 3} LuYAP were used for evaluation. All coincidence data were acquired with a DRS4 based fast digitizer. Results: This new PMT shows promising crystal positioning accuracy, energy and time discrimination performance for TOF, and high-resolution PET applications. The authors also found that a metal channel PMT with SBA was enough for both TOF and high-resolution application, although UBA gave a minor improvement to time resolution. However, significant performance improvement was observed in relative low light output crystals (LuYAP) coupled with UBA. Conclusions: The results of this study will be of value as a useful reference to select PMTs for high-performance PET detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually superior to SPECT image because of the low background noise. The simulation reveals that the detected photon number in SPECT is comparable to that of PET, but the large fraction (approximately 75%) of scattered and penetration photons contaminates SPECT image. The lower limit of {sup 90}Y detection in SPECT image was approximately 200 kBq/ml, while that in PET image was approximately 100 kBq/ml. Conclusions: By comparing the background noise level and the image concentration profile of both the techniques, PET image quality was determined to be superior to that of bremsstrahlung SPECT. The developed simulation codes will be very useful in the future investigations of PET and bremsstrahlung SPECT imaging of {sup 90}Y.

07 ISOTOPE AND RADIATION SOURCES↗

Model Reduction for Steady Hypersonic Aerodynamics via Conservative Manifold Least-Squares Petrov–Galerkin Projection

High-speed aerospace engineering applications rely heavily on computational fluid dynamics (CFD) models for design and analysis. This reliance on CFD models necessitates performing accurate and reliable uncertainty quantification (UQ) of the CFD models, which can be very expensive for hypersonic flows. Additionally, UQ approaches are many-query problems requiring many runs with a wide range of input parameters. One way to enable computationally expensive models to be used in such many-query problems is to employ projection-based reduced-order models (ROMs) in lieu of the (high-fidelity) full-order model (FOM). In particular, the least-squares Petrov–Galerkin (LSPG) ROM (equipped with hyper-reduction) has demonstrated the ability to significantly reduce simulation costs while retaining high levels of accuracy on a range of problems, including subsonic CFD applications. This allows LSPG ROM simulations to replace the FOM simulations in UQ studies, making UQ tractable even for large-scale CFD models. This work presents the first application of LSPG to a hypersonic CFD application, the Hypersonic International Flight Research Experimentation 1 (HIFiRE-1) in a three-dimensional, turbulent Mach 7.1 flow. This paper shows the ability of the ROM to significantly reduce computational costs while maintaining high levels of accuracy in computed quantities of interest.

42 ENGINEERING↗