High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Physics-informed machine learning for fault-leakage reduced-order modeling

Geologic carbon storage (GCS) is a promising technology for mitigating CO 2 emissions. The overall success of GCS depends on safe operations that are informed by risk assessment and have proper mitigation plans in place. Performing quantitative probabilistic risk assessment for a GCS site using traditional reservoir simulators can be challenging due to the high computational costs. To overcome this challenge, the US Department of Energy’s National Risk Assessment Partnership (NRAP) project has developed an integrated assessment modeling approach that utilizes computationally efficient reduced-order models (ROM) for simulating various parts of a GCS storage site to quantify uncertainty. Here, in this study, we develop a reduced-order model for fault leakage risk assessment. We use a deep learning approach to build the reduced-order model. We perform a sensitivity analysis and find that the deep learning model yields high accuracy with a much smaller computational cost than full-physics simulation. We also evaluate the performance of the model in scenarios where simulations are not possible to run, providing analysis not previously performed in fault-leakage ROM analyses. Based on a sensitivity analysis of the model, we suggest a simplified conceptual model for fault leakage and site monitoring.

58 GEOSCIENCES↗

In-situ experiment reveals CO2 enriched fluid migration in faulted caprock

Abstract The sealing characteristics of the geological formation located above a CO 2 storage reservoir, the so-called caprock, are essential to ensure efficient geological carbon storage. If CO 2 were to leak through the caprock, temporal changes in fluid geochemistry can reveal fundamental information on migration mechanisms and induced fluid–rock interactions. Here, we present the results from a unique in-situ injection experiment, where CO 2 -enriched fluid was continuously injected in a faulted caprock analogue. Our results show that the CO 2 migration follows complex pathways within the fault structure. The joint analysis of noble gases, ion concentrations and carbon isotopes allow us to quantify mixing between injected CO 2 -enriched fluid and resident formation water and to describe the temporal evolution of water–rock interaction processes. The results presented here are a crucial complement to the geophysical monitoring at the fracture scale highlighting a unique migration of CO 2 in fault zones.

Science & Technology - Other Topics↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

STEM Characterization of Dislocation Loops in Irradiated FCC Alloys

In this study, we demonstrate the methodology systematically developed for dislocation loop (perfect and faulted loops) imaging and analysis in irradiated face-centered-cubic (FCC) alloys using scanning transmission electron microscopy (STEM). On-zone [001] STEM imaging was identified as the preferred choice for its accuracy and effectiveness based on the comparison with other dislocation loop imaging techniques including: (i) on-zone STEM imaging using other major low-index zone axes, (ii) kinematic two-beam conditions bright field imaging near the [001] zone axis in conventional TEM (CTEM) mode, and (iii) Rel-Rod CTEM dark-field (DF) imaging near the [011] zone axis. The effect of STEM collection angle on the contrast formation of dislocation loops was also investigated. The developed method was confirmed by imaging all populations of perfect and faulted loops of types a/2$\langle$110$\rangle${110} and a/3$\langle$111$\rangle${111} found in an ion irradiated Ni40Fe40Cr20 alloy. The proposed STEM-based technique can easily identify said loops with a size greater than 10 nm without any assumptions such as those commonly made using the conventional Rel-Rod CTEM-DF technique. The recommended methodology in this study is developed as a quick and convenient tool that can be generally applied to irradiated FCC-based materials due to their common crystallography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ensemble models for circuit topology estimation, fault detection and classification in distribution systems

This paper presents a methodology for simultaneous fault detection, classification, and topology estimation for adaptive protection of distribution systems. The methodology estimates the probability of the occurrence of each one of these events by using a hybrid structure that combines three sub-systems, a convolutional neural network for topology estimation, a fault detection based on predictive residual analysis, and a standard support vector machine with probabilistic output for fault classification. The input to all these sub-systems is the local voltage and current measurements. A convolutional neural network uses these local measurements in the form of sequential data to extract features and estimate the topology conditions. The fault detector is constructed with a Bayesian stage (a multitask Gaussian process) that computes a predictive distribution (assumed to be Gaussian) of the residuals using the input. Since the distribution is known, these residuals can be transformed into a Standard distribution, whose values are then introduced into a one-class support vector machine. The structure allows using a one-class support vector machine without parameter cross-validation, so the fault detector is fully unsupervised. Finally, a support vector machine uses the input to perform the classification of the fault types. All three sub-systems can work in a parallel setup for both performance and computation efficiency. In conclusion, we test all three sub-systems included in the structure on a modified IEEE123 bus system, and we compare and evaluate the results with standard approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Internal structure of the San Jacinto fault zone at the Ramona Reservation, north of Anza, California, from dense array seismic data

SUMMARY We image the internal structure of the San Jacinto fault zone (SJFZ) near Anza, California, with seismic data recorded by two dense arrays (RA and RR) from ∼42 000 local and ∼180 teleseismic events occurring between 2012 and 2017. The RA linear array has short aperture (∼470 m long with 12 strong motion sensors) and recorded for the entire analysed time window, whereas the RR is a large three-component nodal array (97 geophones across a ∼2.4 km × 1.4 km area) that operated for about a month in September–October 2016. The SJFZ at the site contains three near-parallel surface traces F1, F2 and F3 from SW to NE that have accommodated several Mw > 6 earthquakes in the past 15 000 yr. Waveform changes in the fault normal direction indicate structural discontinuities that are consistent with the three fault surface traces. Relative slowness from local events and delay time analysis of teleseismic arrivals in the fault normal direction suggest a slower SW side than the NE with a core damage zone between F1 and F2. This core damage zone causes ∼0.05 s delay at stations RR26–31 in the teleseismic P arrivals compared with the SW-most station, and generates both P- and S-type fault zone trapped waves. Inversion of S trapped waves indicates the core damaged structure is ∼100 m wide, ∼4 km deep with a Q value of ∼20 and 40 per cent S-wave velocity reduction compared with bounding rocks. Fault zone head waves observed at stations SW of F3 indicate a local bimaterial interface that separates the locally faster NE block from the broad damage zone in the SW at shallow depth and merges with a deep interface that separates the regionally faster NE block from rocks to the SW with slower velocities at greater depth. The multiscale structural components observed at the site are related to the geological and earthquake rupture history at the site, and provide important information on the preferred NW propagation of earthquake ruptures on the San Jacinto fault.

Geochemistry & Geophysics↗

Fault detection in a three-phase dab converter

A system and method of fault detection based on a detailed waveform analysis is presented for transient and steady-state fault operation of 3-Φ DAB converter. Main symptoms of the converter during normal and fault conditions have been identified and a unique pattern in DC bias of phase currents under fault mode is noted. The logic-based fault diagnosis scheme is used to detect the fault and identify the faulty transistor.

Rastogi, Sagar K.↗

An Online Search Method for Representative Risky Fault Chains Based on Reinforcement Learning and Knowledge Transfer

In the analysis of cascading outages and blackouts in power systems, risky cascading fault chains should be accurately identified in order to do further block or alleviate blackouts. However, the huge computational burden makes online analysis difficult. In this paper, an online search method for representative risky fault chains based on reinforcement learning and knowledge transfer is proposed. This method aims at promoting efficiency by exploiting similarities of adjacent power flow snapshots in operations. After the “representative risky fault chain” is defined, a framework of tree search based on Markov Decision Process and Q-learning is constructed. The knowledge in past runs is accumulated offline and then applied online, with a mechanism of knowledge transition and extension. The proposed learning based approach is verified on an illustrative 39-bus system with different loading levels, and simulations are carried out on a realworld 1000-bus power grid in China to show the effectiveness and efficiency of the proposed approach.

Blackout↗

RAPID

Parallel computer code for the simulator for dynamics of power systems which has the capability to initiate the system and create different faults for the dynamic analysis. The code is based on time-parallel method (Parareal) with Adaptive Method Reduction (AMR). The coarse solvers for the Parareal algorithm include several Semi Analytical Solution methods. Also, Integrated simulation of coupled transmission and distribution systems can be studied.

Simunovic, Srdjan [Oak Ridge National Lab. (ORNL),↗

Overview of Potential Hazards in Electric Aircraft Charging Infrastructure

With increasing efforts in electrification of Advanced Air Mobility and electric aircraft, there is a growing need to install new infrastructure to support them. This report highlights potential hazards (non exhaustive) that the installation must be aware of and be prepared to mitigate with increased electrical equipment on site. The hazards can be due to natural causes as well as non natural causes. The report aims to provide starting guidelines for awareness of these hazards and to help plan for mitigation of the same.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Updated Available Drawdowns for Big Hill SPR Caverns - Model Including the Caprock Fault

This report updates the estimated values of the baseline available drawdowns for the caverns at the Big Hill storage facility, and an updated table listing the available drawdowns. An updated finite element numerical analysis model, which included a fault in the caprock layers, was constructed and the daily data of actual wellhead pressures and oil-brine interfaces was used. The number of available drawdowns for each of the Big Hill SPR caverns is estimated using the new model. All caverns are predicted to have five available drawdowns remaining from a geomechanical perspective. BH-101 and 105 have a region of concern at the floor edge and/or sloping floor, where tensile and dilatant stresses are predicted to occur during each workover. The tensile state is predicted to occur because of the geometries of the edge and floor. Therefore, geomechanical examination for two caverns would be recommended after a drawdown leach. The well integrity of each cavern is not investigated in this report. The estimates for the number of baseline available drawdowns are subject to change in the future as the knowledge of physical phenomena at the sites, and the further development of the models of geomechanical behavior at the sites, evolve over time.

02 PETROLEUM↗

Condition monitoring of permanent magnet AC machines for all-electric transportation systems: State of the art

The current state of the art on emerging and efficient techniques for condition monitoring of permanent magnet (PM) alternating-current (AC) machines deployed in electric vehicle (EV) applications is presented. The discussion includes the most common and specific types of faults in PM motors, such as rotor demagnetisation and stator inter-turn faults, respectively. Fault indicators, such as voltage (v s ) and current (i s ) signals and machine signatures based on motor back electromotive force (EMF) (E B ) and magnetic flux (φ), are taken into account as a measuring quantity in diagnosing motor faults. Other signatures, including thermal analysis, acoustic noise, and vibrations, are also illustrated as some of the emerging techniques in estimating the performance of EV motors while under operations. In addition, various fault modelling methods, condition monitoring techniques, and comprehensive approaches applied in diagnosing the effect of machine faults during its incipient stages are illustrated. Since most of the fault diagnostic techniques discussed here include only machine-based quantities as fault indices/indicators, the provided solutions are therefore found to be more reliable and accurate for diagnosing the motor faults. This comprehensive review study is inclusive of the existing fault diagnostic techniques, which are currently employed in industrial and commercial practices, in addition to the new methodologies proposed by the authors. All the given condition monitoring schemes therefore seem significantly vital in estimating the state of health of PM AC machines while under operation in all-electric transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of the thermal recovery of HTS cables after an overcurrent fault

High temperature superconducting (HTS) power transmission cables are cooled to operating temperatures typically below 80 K. A valuable feature of some HTS cables is that they can limit short-circuit fault currents, which can be more than ten times the maximum operating current of a cable. When a fault occurs the HTS wire is no longer superconducting and the heating which occurs will raise the temperature above the allowable operating point. To recover from the fault, the conductor must be cooled down before returning to service. The recovery is affected by the refrigeration system's performance which varies with load and temperature. A transient numerical model of an HTS cable is applied to investigate the thermal recovery after a fault for some HTS cable system configurations and operating conditions.

Demko, Jonathan A.↗

Rotor blade imbalance fault detection for variable-speed marine current turbines via generator power signal analysis

Marine hydrokinetic (MHK) turbines extract renewable energy from oceanic environments. However, due to the harsh conditions that these turbines operate in, system performance naturally degrades over time. Thus, ensuring efficient condition-based maintenance is imperative towards guaranteeing reliable operation and reduced costs for marine hydrokinetic power. This work proposes a novel framework aimed at identifying and classifying the severity of rotor blade pitch imbalance faults experienced by marine current turbines (MCTs). In the framework, a Continuous Morlet Wavelet Transform (CMWT) is first utilized to acquire the wavelet coefficients encompassed within the 1P frequency range of the turbine's rotor shaft. From these coefficients, several statistical indices are tabulated into a six-dimensional feature space. Next, Principle Component Analysis (PCA) is employed on the resulting feature space for dimensionality reduction, and then the application of a K-Nearest Neighbor (KNN) machine learning algorithm is utilized for fault detection and severity classification. The effectiveness of the proposed framework is validated using a high-fidelity MCT numerical simulation platform, where results demonstrate that the presence of a pitch imbalance fault can be accurately detected 100% of the time and correctly classified based upon severity more than 97% of the time.