Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Leak Detection and H2 Sensor Development for Hydrogen Applications

Recent developments in the search for sustainable and renewable energy coupled with the advancements in fuel cell powered vehicles (FCVs) have augmented the demand for hydrogen safety sensors. There are several sensor technologies that have been developed to detect hydrogen, including deployed systems to detect leaks in manned space systems and hydrogen safety sensors for laboratory and industrial usage. Among the several sensing methods electrochemical devices that utilize high temperature-based ceramic electrolytes are largely unaffected by changes in humidity and are more resilient to electrode or electrolyte poisoning. The desired sensing technique should meet a detection threshold of 1% (10,000 ppm) H 2 and response time of ≤1 min, which is a target for infrastructure and vehicular uses. Further, a review of electrochemical hydrogen sensors by Korotcenkov et.al and the report by Glass et.al suggest the need for inexpensive, low power, and compact sensors with long-term stability, minimal cross-sensitivity, and fast response. This view has been largely validated and supported by the fuel cell and hydrogen infrastructure industries by the NREL/DOE Hydrogen Sensor Workshop held on June 8, 2011. Many of the issues preventing widespread adoption of best-available hydrogen sensing technologies available today outside of cost, derive from excessive false positives and false negatives arising from signal drift and unstable sensor baseline; both of these problems necessitate the need for unacceptable frequent calibration.

08 HYDROGEN↗

Advancing Aviation Security

Air travel is a popular mode of transportation. Each year, more than 600 million people board U.S. flights for business or pleasure. As demonstrated on 9/11, a coordinated terrorist strike on commercial airlines has devastating consequences where many lives could be lost and the nation’s economy could be crippled. The Transportation Security Administration (TSA) has worked diligently to enhance security at airports and on flights so that people and cargo can continue to move freely. Today, all passengers and every piece of checked or carry-on luggage are screened before they are permitted on an aircraft. X-ray systems and walk-through metal detectors allow security personnel to identify dangerous metal objects, such as guns and knives. A more complex problem is the detection of explosives, where detection technologies such as multiple-energy X-ray radiography, computed tomography (CT), full body scanners using millimeter wave and X-ray backscatter and other techniques are used to screen for explosives hidden in luggage, in cargo and on the people boarding the aircraft. Scientists and engineers at the Lawrence Livermore National Laboratory (LLNL) are working with the Department of Homeland Security (DHS), Science and Technology Directorate (S&T), Explosives Division (EXD) to help improve aviation security by evaluating and enhancing the performance of next-generation explosives detection technologies. LLNL is providing subject matter expertise to TSA for their multi-billion dollar procurements of explosive detection system (EDS) for the nation’s airports and provides recommendations for process and system improvements. To further improve aviation security, EXD is funding research at LLNL to develop advanced explosives detection technologies that can more accurately discriminate between a wide range of explosives and non-threat materials. One challenge with scanning for explosives is that some nonthreatening materials share similar characteristics with actual threats, leading to false positives or false alarms. When an alarm is generated, security personnel must review the scan images to clear the alarm or manually open and verify the bag’s contents, which can increase labor costs and lead to passenger delays. The Livermore efforts currently focus on CT-based applications. First developed for the medical field as a method for diagnosing disease, X-ray CT has become instrumental in various industrial Non-Destructive Evaluation (NDE) applications. Explosives detection equipment that incorporates CT uses a broad-spectrum X-ray beam to capture projections of an object, in particular, the objects inside a piece of luggage. The CT system then applies complex reconstruction algorithms to the projections to produce a three-dimensional representation of the luggage and its contents. Automated threat-detection algorithms (also referred to as threat-recognition algorithms) further process the images to separate each item and flag potential threats for further review (see Figure 1). Transportation security officers can then examine these images and the relevant data to determine whether further interrogation is needed. LLNL has also performed research on advanced X-ray carry-on bag inspection systems and is helping to better understand the performance of X-ray backscatter and millimeter wave passenger screening systems.

42 ENGINEERING↗

CSTT Update: Fuel Quality Analyzer

Presentation summary: A Nafion® based, electrochemical hydrogen contaminant detector was tested at H2Frontier hydrogen filling station in Burbank CA during its refit and recommissioning.; A 100 sccm sample was taken from the H2F production skid and without requiring humidification; both real-time product gas and storage gas was sampled. The selfhumidifying approach using an internal reservoir worked with minimal baseline drift.; The LANL HCD easily detected CO byproduct during reformer restart (as high as 18ppm) and 11, 1ppm challenges were performed during an 850h experiment after initial installation and 10ppm testing/commissioning.; The 10ppm and 1ppm challenges produced ≈ 75% and ≈ 60% reductions in pumping current respectively. Twelve, 1ppm challenges decreased pumping current on average of 59.5% with an error of ±1.4% over 12 challenges during a 6 month time period.; Long term baseline data show a drift rate of 9x10- 7 A/h over a 600h period of testing. The addition of a 1.5V, 600s pulse approximately once a day eliminated any long term drift.; No false positives or false negatives were seen during the field tests to date.; Average water consumption rate is estimated to be ~250μl/day at 100sccm.; Project milestones successfully met.

08 HYDROGEN↗

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

SAGE Intrusion Detection System: Sensitivity Analysis Guided Explainability for Machine Learning.

This report details the results of a three-fold investigation of sensitivity analysis (SA) for machine learning (ML) explainability (MLE): (1) the mathematical assessment of the fidelity of an explanation with respect to a learned ML model, (2) quantifying the trustworthiness of a prediction, and (3) the impact of MLE on the efficiency of end-users through multiple users studies. We focused on the cybersecurity domain as the data is inherently non-intuitive. As ML is being using in an increasing number of domains, including domains where being wrong can elicit high consequences, MLE has been proposed as a means of generating trust in a learned ML models by end users. However, little analysis has been performed to determine if the explanations accurately represent the target model and they themselves should be trusted beyond subjective inspection. Current state-of-the-art MLE techniques only provide a list of important features based on heuristic measures and/or make certain assumptions about the data and the model which are not representative of the real-world data and models. Further, most are designed without considering the usefulness by an end-user in a broader context. To address these issues, we present a notion of explanation fidelity based on Shapley values from cooperative game theory. We find that all of the investigated MLE explainability methods produce explanations that are incongruent with the ML model that is being explained. This is because they make critical assumptions about feature independence and linear feature interactions for computational reasons. We also find that in deployed, explanations are rarely used due to a variety of reason including that there are several other tools which are trusted more than the explanations and there is little incentive to use the explanations. In the cases when the explanations are used, we found that there is the danger that explanations persuade the end users to wrongly accept false positives and false negatives. However, ML model developers and maintainers find the explanations more useful to help ensure that the ML model does not have obvious biases. In light of these findings, we suggest a number of future directions including developing MLE methods that directly model non-linear model interactions and including design principles that take into account the usefulness of explanations to the end user. We also augment explanations with a set of trustworthiness measures that measure geometric aspects of the data to determine if the model output should be trusted.

97 MATHEMATICS AND COMPUTING↗

Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief that this multivariate analysis will enable superior differentiation capabilities. In addition, noise and system artifacts challenge the analysis of GC-MS data collected on lower cost equipment, ubiquitous in commercial laboratories. This research has the potential to affect many areas of analytical chemistry including materials analysis, medical testing, and environmental surveillance. It could also provide a method to measure adsorption parameters for chemical interactions on various surfaces by measuring desorption as a function of temperature for mixtures. We have presented results of a novel method for examining offgas products of a common PDMS material. Our method involves utilizing a stepped TD/GC-MS data acquisition scheme that may be almost totally automated, coupled with multivariate analysis schemes. This method of data generation and analysis can be applied to a number of materials aging and thermal degradation studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing Docking Accuracy with PECAN2, a 3D Atomic Neural Network Trained without Co-Complex Crystal Structures

Decades of drug development research have explored a vast chemical space for highly active compounds. The exponential growth of virtual libraries enables easy access to billions of synthesizable molecules. Computational modeling, particularly molecular docking, utilizes physics-based calculations to prioritize molecules for synthesis and testing. Nevertheless, the molecular docking process often yields docking poses with favorable scores that prove to be inaccurate with experimental testing. To address these issues, several approaches using machine learning (ML) have been proposed to filter incorrect poses based on the crystal structures. However, most of the methods are limited by the availability of structure data. Here, we propose a new pose classification approach, PECAN2 (Pose Classification with 3D Atomic Network 2), without the need for crystal structures, based on a 3D atomic neural network with Point Cloud Network (PCN). The new approach uses the correlation between docking scores and experimental data to assign labels, instead of relying on the crystal structures. We validate the proposed classifier on multiple datasets including human mu, delta, and kappa opioid receptors and SARS-CoV-2 Mpro. Our results demonstrate that leveraging the correlation between docking scores and experimental data alone enhances molecular docking performance by filtering out false positives and false negatives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A NEW METHOD FOR FINDING POINT SOURCES IN HIGH-ENERGY NEUTRINO DATA

The IceCube collaboration has reported the first detection of high-energy astrophysical neutrinos, including ∼50 high-energy starting events, but no individual sources have been identified. It is therefore important to develop the most sensitive and efficient possible algorithms to identify the point sources of these neutrinos. The most popular current method works by exploring a dense grid of possible directions to individual sources, and identifying the single direction with the maximum probability of having produced multiple detected neutrinos. This method has numerous strengths, but it is computationally intensive and because it focuses on the single best location for a point source, additional point sources are not included in the evidence. We propose a new maximum likelihood method that uses the angular separations between all pairs of neutrinos in the data. Unlike existing autocorrelation methods for this type of analysis, which also use angular separations between neutrino pairs, our method incorporates information about the point-spread function and can identify individual point sources. We find that if the angular resolution is a few degrees or better, then this approach reduces both false positive and false negative errors compared to the current method, and is also more computationally efficient up to, potentially, hundreds of thousands of detected neutrinos.

79 ASTRONOMY AND ASTROPHYSICS↗

Intelligent System Development Using a Rough Sets Methodology

The purpose of this research was to examine the potential of the rough sets technique for developing intelligent models of complex systems from limited information. Rough sets a simple but promising technology to extract easily understood rules from data. The rough set methodology has been shown to perform well when used with a large set of exemplars, but its performance with sparse data sets is less certain. The difficulty is that rules will be developed based on just a few examples, each of which might have a large amount of noise associated with them. The question then becomes, what is the probability of a useful rule being developed from such limited information? One nice feature of rough sets is that in unusual situations, the technique can give an answer of 'I don't know'. That is, if a case arises that is different from the cases the rough set rules were developed on, the methodology can recognize this and alert human operators of it. It can also be trained to do this when the desired action is unknown because conflicting examples apply to the same set of inputs. This summer's project was to look at combining rough set theory with statistical theory to develop confidence limits in rules developed by rough sets. Often it is important not to make a certain type of mistake (e.g., false positives or false negatives), so the rules must be biased toward preventing a catastrophic error, rather than giving the most likely course of action. A method to determine the best course of action in the light of such constraints was examined. The resulting technique was tested with files containing electrical power line 'signatures' from the space shuttle and with decompression sickness data.

Anderson, Gray T.↗

Prediction of Coronal Mass Ejections From Vector Magnetograms: Quantitative Measures as Predictors

We derived two quantitative measures of an active region's global nonpotentiality from the region's vector magnetogram, 1) the net current (I(sub N)), and 2) the length of strong-shear, strong-field main neutral line (Lss), and used these two measures in a pilot study of the CME productivity of 4 active regions. We compared the global nonpotentiality measures to the active regions' CME productivity determined from GOES and Yohkoh/SXT observations. We found that two of the active regions were highly globally nonpotential and were CME productive, while the other two active regions had little global nonpotentiality and produced no CMEs. At the Fall 2000 AGU, we reported on an expanded study (12 active regions and 17 magnetograms) in which we evaluated four quantitative global measures of an active region's magnetic field and compared these measures with the CME productivity. The four global measures (all derived from MSFC vector magnetograms) included our two previous measures (I(sub N) and L(sub ss)) as well as two new ones, the total magnetic flux (PHI) (a measure of an active region's size), and the normalized twist (alpha (bar)= muIN/PHI). We found that the three quantitative measures of global nonpotentiality (I(sub N), L(sub ss), alpha (bar)) were all well correlated (greater than 99% confidence level) with an active region's CME productivity within plus or minus 2 days of the day of the magnetogram. We will now report on our findings of how good our quantitative measures are as predictors of active-region CME productivity, using only CMEs that occurred after the magnetogram. We report the preliminary skill test of these quantitative measures as predictors. We compare the CME prediction success of our quantitative measures to the CME prediction success based on an active region's past CME productivity. We examine the cases of the handful of false positive and false negatives to look for improvements to our predictors. This work is funded by NSF through the Space Weather Program and by NASA through the Solar Physics Supporting Research and Technology Program.

Falconer, D. A.↗

J-2X Abort System Development

The J-2X is an expendable liquid hydrogen (LH2)/liquid oxygen (LOX) gas generator cycle rocket engine that is currently being designed as the primary upper stage propulsion element for the new NASA Ares vehicle family. The J-2X engine will contain abort logic that functions as an integral component of the Ares vehicle abort system. This system is responsible for detecting and responding to conditions indicative of impending Loss of Mission (LOM), Loss of Vehicle (LOV), and/or catastrophic Loss of Crew (LOC) failure events. As an earth orbit ascent phase engine, the J-2X is a high power density propulsion element with non-negligible risk of fast propagation rate failures that can quickly lead to LOM, LOV, and/or LOC events. Aggressive reliability requirements for manned Ares missions and the risk of fast propagating J-2X failures dictate the need for on-engine abort condition monitoring and autonomous response capability as well as traditional abort agents such as the vehicle computer, flight crew, and ground control not located on the engine. This paper describes the baseline J-2X abort subsystem concept of operations, as well as the development process for this subsystem. A strategy that leverages heritage system experience and responds to an evolving engine design as well as J-2X specific test data to support abort system development is described. The utilization of performance and failure simulation models to support abort system sensor selection, failure detectability and discrimination studies, decision threshold definition, and abort system performance verification and validation is outlined. The basis for abort false positive and false negative performance constraints is described. Development challenges associated with information shortfalls in the design cycle, abort condition coverage and response assessment, engine-vehicle interface definition, and abort system performance verification and validation are also discussed.

Santi, Louis M.↗

Science requirements for LISA

Historically, gravitational wave antennas have been characterized by their detection capability. This is measured in terms of signal-to-noise ratio, and implies a rate of false positives and false negatives. But to do useful astrophysics, one would like to measure - or more properly, estimate - astrophysical parameters of the gravitational wave sources. In the interest of strengthening the connection between science objectives and a specific instrument performance, the LISA community has reformulated the Laser Interferometer Space Antenna (LlSA) science requirements around the anticipated uncertainty in astrophysical parameter estimation. The rationale for this characterization of LlSA and a summary of the astrophysics and fundamental physics that LISA can do will be given. LISA will be able to make precision measurements of sources out to z approximately equal to 10.

Stebbins, Robin T.↗

Uncertainty in Heart Rate Complexity Metrics Caused by R-Peak Perturbations

Heart rate complexity (HRC) is a proven metric for gaining insight into human stress and physiological deterioration. To calculate HRC, the detection of the exact instance of when the heart beats, the R-peak, is necessary. Electrocardiogram (ECG) signals can often be corrupted by environmental noise (e.g., from electromagnetic interference, movement artifacts), which can potentially alter the HRC measurement, producing erroneous inputs which feed into decision support models. Current literature has only investigated how HRC is affected by noise when R-peak detection errors occur (false positives and false negatives). However, the numerical methods used to calculate HRC are also sensitive to the specific location of the fiducial point of the R-peak. This raises many questions regarding how this fiducial point is altered by noise, the resulting impact on the measured HRC, and how we can account for noisy HRC measures as inputs into our decision models. This work uses Monte Carlo simulations to systematically add white and pink noise at different permutations of signal-to-noise ratios (SNRs), time segments, sampling rates, and HRC measurements to characterize the influence of noise on the HRC measure by altering the fiducial point of the R-peak. Using the generated information from these simulations provides improved decision processes for system design which address key concerns such as permutation entropy being a more precise, reliable, less biased, and more sensitive measurement for HRC than sample and approximate entropy.

Napoli, Nicholas J.↗

Automated Classification of Transient Contamination in Stationary Acoustic Data

An automated procedure for the classification of transient contamination of stationary acoustic data is proposed and analyzed. The procedure requires the assumption that the stationary acoustic data of interest can be modeled as a band-limited, Gaussian random process. It also requires that the transient contamination be of higher variance than the acoustic data of interest. When these assumptions are satisfied, it is a blind separation procedure, aside from the initial input specifying how to subdivide the time series of interest. No a priori threshold criterion is required. Simulation results show that for a sufficient number of blocks, the method performs well, as long as the occasional false positive or false negative is acceptable. The effectiveness of the procedure is demonstrated with an application to experimental wind tunnel acoustic test data which are contaminated by hydrodynamic gusts.

Bahr, Christopher J.↗

Automated Classification of Transient Contamination in Stationary Acoustic Data

An automated procedure for the classification of transient contamination of stationary acoustic data is proposed and analyzed. The procedure requires the assumption that the stationary acoustic data of interest can be modeled as a band-limited, Gaussian random process. It also requires that the transient contamination be of higher variance than the acoustic data of interest. When these assumptions are satisfied, it is a blind separation procedure, aside from the initial input specifying how to subdivide the time series of interest. No a priori threshold criterion is required. Simulation results show that for a sufficient number of blocks, the method performs well, as long as the occasional false positive or false negative is acceptable. The effectiveness of the procedure is demonstrated with an application to experimental wind tunnel acoustic test data which are contaminated by hydrodynamic gusts.

binary classification↗

Classifying Agnostic Biosignatures using Raman, VNIR, and Elemental Data

How can we use our current wealth of terrestrial data, encompassing biogenic and abiogenic systems, to determine the distinguishing properties of life? SCOBI (Statistical Classification of Biosignature Information) uses machine learning techniques to algorithmically identify combinations of measurements that are “indicative of life”. A set of ~1000 observations, comprising elemental abundance, isotopic fractionation, VNIR reflectance, and (in progress) Raman spectra, have been assembled from existing literature and databases. The observations cover systems classified as “indicative alive” (e.g., cells, vegetation), “indicative non-alive” (e.g., fossils, teeth), “mixed indicative” (e.g., soil, pond water), or “non-indicative” (e.g., rocks, meteorites). VNIR data was preprocessed by linear interpolation from 400-2100 nm and smoothed with a Savitzky-Golay filter. To limit the amount of Earth-biochemistry-specific (non-agnostic) information included, the first five spectral features extracted were number of peaks, number of troughs, mean reflectance, mean peak width, and broadest peak width. To help further emphasize agnostic biosignatures, Earth-specific features such as chlorophylls have been manually flagged so that feature importance with and without them can be compared. Classifiers including k-nearest neighbors (KNN), Gaussian Naïve Bayes (GNB), logistic regression (LR), random forest (RF), and support vector machine (SVM) were implemented, as was a combination voting classifier. Performance metrics included false positive rates, false negative rates, and AUC with 50-50 test/train splits (Monte Carlo simulations). Key takeaways from this stage, prior to the inclusion of Raman spectra, are (1) the overall success rate of 0.933 AUC was most heavily influenced by the elemental abundance data; and (2) VNIR reflectance had the lowest classification performance with 0.52 AUC (58% of objects correctly classified). The next steps are to complete integration of Raman spectral data and to improve the approach to pre-processing and feature extraction for both types of spectral data, such as automated baseline removal, whole spectrum matching, and dimensionality reduction.

Biosignatures↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E. Z. Klier↗