Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false negative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Tracking Object Existence From an Autonomous Patrol Vehicle

An autonomous vehicle patrols a large region, during which an algorithm receives measurements of detected potential objects within its sensor range. The goal of the algorithm is to track all objects in the region over time. This problem differs from traditional multi-target tracking scenarios because the region of interest is much larger than the sensor range and relies on the movement of the sensor through this region for coverage. The goal is to know whether anything has changed between visits to the same location. In particular, two kinds of alert conditions must be detected: (1) a previously detected object has disappeared and (2) a new object has appeared in a location already checked. For the time an object is within sensor range, the object can be assumed to remain stationary, changing position only between visits. The problem is difficult because the upstream object detection processing is likely to make many errors, resulting in heavy clutter (false positives) and missed detections (false negatives), and because only noisy, bearings-only measurements are available. This work has three main goals: (1) Associate incoming measurements with known objects or mark them as new objects or false positives, as appropriate. For this, a multiple hypothesis tracker was adapted to this scenario. (2) Localize the objects using multiple bearings-only measurements to provide estimates of global position (e.g., latitude and longitude). A nonlinear Kalman filter extension provides these 2D position estimates using the 1D measurements. (3) Calculate the probability that a suspected object truly exists (in the estimated position), and determine whether alert conditions have been triggered (for new objects or disappeared objects). The concept of a probability of existence was created, and a new Bayesian method for updating this probability at each time step was developed. A probabilistic multiple hypothesis approach is chosen because of its superiority in handling the uncertainty arising from errors in sensors and upstream processes. However, traditional target tracking methods typically assume a stationary detection volume of interest, whereas in this case, one must make adjustments for being able to see only a small portion of the region of interest and understand when an alert situation has occurred. To track object existence inside and outside the vehicle's sensor range, a probability of existence was defined for each hypothesized object, and this value was updated at every time step in a Bayesian manner based on expected characteristics of the sensor and object and whether that object has been detected in the most recent time step. Then, this value feeds into a sequential probability ratio test (SPRT) to determine the status of the object (suspected, confirmed, or deleted). Alerts are sent upon selected status transitions. Additionally, in order to track objects that move in and out of sensor range and update the probability of existence appropriately a variable probability detection has been defined and the hypothesis probability equations have been re-derived to accommodate this change. Unsupervised object tracking is a pervasive issue in automated perception systems. This work could apply to any mobile platform (ground vehicle, sea vessel, air vehicle, or orbiter) that intermittently revisits regions of interest and needs to determine whether anything interesting has changed.

Wolf, Michael↗

Timely Reporting of Heavy Hitters Using External Memory

Given an input stream S of size N, a Φ-heavy hitter is an item that occurs at least ΦN times in S. The problem of finding heavy-hitters is extensively studied in the database literature. In this work, we study a real-time heavy-hitters variant in which an element must be reported shortly after we see its T = Φ N-th occurrence (and hence it becomes a heavy hitter). We call this the Timely Event Detection (TED) Problem. The TED problem models the needs of many real-world monitoring systems, which demand accurate (i.e., no false negatives) and timely reporting of all events from large, high-speed streams with a low reporting threshold (high sensitivity). Like the classic heavy-hitters problem, solving the TED problem without false-positives requires large space (Ω (N) words). Thus in-RAM heavy-hitters algorithms typically sacrifice accuracy (i.e., allow false positives), sensitivity, or timeliness (i.e., use multiple passes). We show how to adapt heavy-hitters algorithms to external memory to solve the TED problem on large high-speed streams while guaranteeing accuracy, sensitivity, and timeliness. Our data structures are limited only by I/O-bandwidth (not latency) and support a tunable tradeoff between reporting delay and I/O overhead. With a small bounded reporting delay, our algorithms incur only a logarithmic I/O overhead. We implement and validate our data structures empirically using the Firehose streaming benchmark. Multi-threaded versions of our structures can scale to process 11M observations per second before becoming CPU bound. In comparison, a naive adaptation of the standard heavy-hitters algorithm to external memory would be limited by the storage device’s random I/O throughput, i.e., ≈100K observations per second.

97 MATHEMATICS AND COMPUTING↗

Evaluating Precipitation Events Using GPM IMERG 30-Minute Near Real-Time Precipitation Estimates

Accurately detecting and estimating precipitation at near–real time (NRT) is of utmost importance for the early detection and monitoring of hydrometeorological hazards. The precipitation product, Integrated Multi-satellitE Retrievals for Global Precipitation Measurement (IMERG), provides NRT 0.1° and 30-min precipitation estimates across the globe with only a 4-h latency. This study was an evaluation of the GPM IMERG version 6 level-3 early run 30-min precipitation product for precipitation events from 2014 through 2020. The purpose of this research was to identify when, where, and why GPM IMERG misidentified and failed to detect precipitation events in California, Nevada, Arizona, and Utah in the United States. Precipitation events were identified based on 15-min precipitation from gauges and 30-min precipitation from the IMERG multisatellite constellation. False-positive and false-negative precipitation events were identified and analyzed to determine their characteristics. Precipitation events identified by gauges had longer duration and had higher cumulative precipitation than those identified by GPM IMERG. GPM IMERG had many false event detections during the summer months, suggesting possible virga event detection, which is when precipitation falls from a cloud but evaporates before it reaches the ground. The frequency and timing of the merged passive microwave (PMW) product and forward propagation were responsible for IMERG overestimating cumulative precipitation during some precipitation events and underestimating others. This work can inform experts that are using the GPM IMERG NRT product to be mindful of situations where GPM IMERG–estimated precipitation events may not fully resolve the hydrometeorological conditions driving these hazards.

Jessica R P Sutton↗

Using Natural Language Processing of Free-Text Radiology Reports to Identify Type 1 Modic Endplate Changes

Electronic medical record (EMR) systems provide easy access to radiology reports and offer great potential to support quality improvement efforts and clinical research. Harnessing the full potential of the EMR requires scalable approaches such as natural language processing (NLP) to convert text into variables used for evaluation or analysis. Our goal was to determine the feasibility of using NLP to identify patients with Type 1 Modic endplate changes using clinical reports of magnetic resonance (MR) imaging examinations of the spine. Identifying patients with Type 1 Modic change who may be eligible for clinical trials is important as these findings may be important targets for intervention. Four annotators identified all reports that contained Type 1 Modic change, using N = 458 randomly selected lumbar spine MR reports. We then implemented a rule-based NLP algorithm in Java using regular expressions. The prevalence of Type 1 Modic change in the annotated dataset was 10%. Results were recall (sensitivity) 35/50 = 0.70 (95% confidence interval (C.I.) 0.52–0.82), specificity 404/408 = 0.99 (0.97–1.0), precision (positive predictive value) 35/39 = 0.90 (0.75–0.97), negative predictive value 404/419 = 0.96 (0.94–0.98), and F1-score 0.79 (0.43–1.0). Our evaluation shows the efficacy of rule-based NLP approach for identifying patients with Type 1 Modic change if the emphasis is on identifying only relevant cases with low concern regarding false negatives. As expected, our results show that specificity is higher than recall. This is due to the inherent difficulty of eliciting all possible keywords given the enormous variability of lumbar spine reporting, which decreases recall, while availability of good negation algorithms improves specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating event detection system operation characteristics into sensor placement optimization.

We consider the problem of placing sensors in a municipal water network when we can choose both the location of sensors and the sensitivity and specificity of the contamination warning system. Sensor stations in a municipal water distribution network continuously send sensor output information to a centralized computing facility, and event detection systems at the control center determine when to signal an anomaly worthy of response. Although most sensor placement research has assumed perfect anomaly detection, signal analysis software has parameters that control the tradeoff between false alarms and false negatives. We describe a nonlinear sensor placement formulation, which we heuristically optimize with a linear approximation that can be solved as a mixed-integer linear program. We report the results of initial experiments on a real network and discuss tradeoffs between early detection of contamination incidents, and control of false alarms.

54 ENVIRONMENTAL SCIENCES↗

False positive PSMA PET for tumor remnants in the irradiated prostate and other interpretation pitfalls in a prospective multi-center trial

Readers need to be informed about potential pitfalls of [ 68 Ga]Ga-PSMA-11 PET interpretation. Here we report [ 68 Ga]Ga-PSMA-11 PET findings discordant with the histopathology/composite reference standard in a recently published prospective trial on 635 patients with biochemically recurrent prostate cancer. Consensus reads were false positive in 20 regions of 17/217 (8%) patients with lesion validation. Majority of the false positive interpretations (13 of 20, 65%) occurred in the context of suspected prostate (bed) relapse (T) after radiotherapy ( n = 11); other false positive findings were noted for prostate bed post prostatectomy (T, n = 2), pelvic nodes (N, n = 2), or extra pelvic lesions (M, n = 5). Major sources of false positive findings were PSMA-expressing residual adenocarcinoma with marked post-radiotherapy treatment effect. False negative interpretation occurred in 8 regions of 6/79 (8%) patients with histopathology validation, including prostate (bed) ( n = 5), pelvic nodes ( n = 1), and extra pelvic lesions ( n = 2). Lesions were missed mostly due to small metastases or adjacent bladder/urine uptake.[ 68 Ga]Ga-PSMA-11 PET at biochemical recurrence resulted in less than 10% false positive interpretations. Post-radiotherapy prostate uptake was a major source of [ 68 Ga]Ga-PSMA-11 PET false positivity. In few cases, PET correctly detects residual PSMA expression post-radiotherapy, originating however from treated, benign tissue or potentially indolent tumor remnants.

Radiology, Nuclear Medicine & Medical Imaging↗

Ares I-X Ground Diagnostic Prototype

Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype uses the outputs of SHINE as inputs to TEAMS. The third tool, the Inductive Monitoring System (IMS), is an anomaly detection tool developed at NASA Ames Research Center and is currently used to monitor the International Space Station Control Moment Gyroscopes. IMS automatically "learns" a model of historical nominal data in the form of a set of clusters and signals an alarm when new data fails to match this model. IMS offers the potential to detect faults that have not been modeled. The three tools have been integrated and deployed to Hangar AE at KSC where they interface with live data from the Ares I-X vehicle and from the ground hydraulics. The outputs of the tools are displayed on a console in Hangar AE, one of the locations from which the Ares I-X launch will be monitored. The full paper will describe how the prototype performed before the launch. It will include an analysis of the prototype's accuracy, including false-positive rates, false-negative rates, and receiver operating characteristics (ROC) curves. It will also include a description of the prototype's computational requirements, including CPU usage, main memory usage, and disk usage. If the prototype detects any faults during the prelaunch period then the paper will include a description of those faults. Similarly, if the prototype has any false alarms then the paper will describe them and will attempt to explain their causes.

Schwabacher, Mark↗

Integrating Data From In Vitro New Approach Methodologies for Developmental Neurotoxicity

Abstract In vivo developmental neurotoxicity (DNT) testing is resource intensive and lacks information on cellular processes affected by chemicals. To address this, DNT new approach methodologies (NAMs) are being evaluated, including: the microelectrode array neuronal network formation assay; and high-content imaging to evaluate proliferation, apoptosis, neurite outgrowth, and synaptogenesis. This work addresses 3 hypotheses: (1) a broad screening battery provides a sensitive marker of DNT bioactivity; (2) selective bioactivity (occurring at noncytotoxic concentrations) may indicate functional processes disrupted; and, (3) a subset of endpoints may optimally classify chemicals with in vivo evidence for DNT. The dataset was comprised of 92 chemicals screened in all 57 assay endpoints sourced from publicly available data, including a set of DNT NAM evaluation chemicals with putative positives (53) and negatives (13). The DNT NAM battery provides a sensitive marker of DNT bioactivity, particularly in cytotoxicity and network connectivity parameters. Hierarchical clustering suggested potency (including cytotoxicity) was important for classifying positive chemicals with high sensitivity (93%) but failed to distinguish patterns of disrupted functional processes. In contrast, clustering of selective values revealed informative patterns of differential activity but demonstrated lower sensitivity (74%). The false negatives were associated with several limitations, such as the maximal concentration tested or gaps in the biology captured by the current battery. This work demonstrates that this multi-dimensional assay suite provides a sensitive biomarker for DNT bioactivity, with selective activity providing possible insight into specific functional processes affected by chemical exposure and a basis for further research.

Carstens, Kelly E.↗

Grandparent Inference from Genetic Data: The Potential for Parentage-Based Tagging Programs to Identify Offspring of Hatchery Strays

Abstract Fisheries managers routinely use hatcheries to increase angling opportunity. Many hatcheries operate as segregated programs where hatchery-origin fish are not intended to spawn with natural-origin conspecifics in order to prevent potential negative effects on the natural-origin population. Currently available techniques to monitor the frequency with which hatchery-origin strays successfully spawn in the wild rely on either genetic differentiation between the hatchery- and natural-origin fish or extensive sampling of fish on the spawning grounds. We present a method to infer grandparent–grandchild trios by using only genotypes from two putative grandparents and one putative grandchild. We developed estimators of false-positive and false-negative error rates and showed that genetic panels containing 500–700 single-nucleotide polymorphisms or 200–300 microhaplotypes are expected to allow application of this technique for monitoring segregated hatchery programs. We discuss the ease with which this technique can be implemented by pre-existing parentage-based tagging programs and provide an R package that applies the method.

Delomas, Thomas A. (ORCID:000000015154759X)↗

Using distributed temperature sensing to detect CO 2 leakage along the injection well casing

The objective of this study is to evaluate the sensitivity of Distributed Temperature Sensing (DTS) data to detect CO 2 leakage along an injection well casing. This paper describes the relationship between the CO 2 leakage rate and temperature response at DTS locations, and the method and numerical model used for understanding such a relationship. The uncertainties in the parameters are propagated to the interpretation of DTS measurements, which may lead to false positive and false negative identifications of CO 2 leakage. We propose to identify CO 2 leakage by analyzing both temperature history plots at selected vertical locations as well as the vertical temperature profiles at different times. The analysis should be combined with numerical simulations for the estimation of leakage rates. In addition, leakage needs to be confirmed by data from a warm-up test (temperature recovery after injection of cold CO 2 is stopped) to minimize the probability of false identifications.

42 ENGINEERING↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

PCR Based Microbial Monitor for Analysis of Recycled Water Aboard the ISSA: Issues and Prospects

The monitoring of spacecraft life support systems for the presence of health threatening microorganisms is paramount for crew well being and successful completion of missions. Development of technology to monitor spacecraft recycled water based on detection and identification of the genetic material of contaminating microorganisms and viruses would be a substantial improvement over current NASA plans to monitor recycled water samples that call for the use of conventional microbiology techniques which are slow, insensitive, and labor intensive. The union of the molecular biology techniques of DNA probe hybridization and polymerase chain reaction (PCR) offers a powerful method for the detection, identification, and quantification of microorganisms and viruses. This technology is theoretically capable of assaying samples in as little as two hours with specificity and sensitivity unmatched by any other method. A major advance in probe-hybridization/PCR has come about in a technology called TaqMan(TM), which was invented by Perkin Elmer. Instrumentation using TaqMan concepts is evolving towards devices that could meet NASA's needs of size, low power use, and simplicity of operation. The chemistry and molecular biology needed to utilize these probe-hybridization/PCR instruments must evolve in parallel with the hardware. The following issues of chemistry and biology must be addressed in developing a monitor: Early in the development of a PCR-based microbial monitor it will be necessary to decide how many and which organisms does the system need the capacity to detect. We propose a set of 17 different tests that would detect groups of bacteria and fungus, as well as specific eukaryotic parasites and viruses; In order to use the great sensitivity of PCR it will be necessary to concentrate water samples using filtration. If a lower limit of detection of 1 microorganism per 100 ml is required then the microbes in a 100 ml sample must be concentrated into a volume that can be added to a PCR assay; There are not likely to be contaminants in ISSA recycled water that would inhibit PCR resulting in false-negative results; The TaqMan PCR product detection system is the most promising method for developing a rapid, highly automated gene-based microbial monitoring system. The method is inherently quantitative. NASA and other government agencies have invested in other technologies that, although potentially could lead to revolutionary advances, are not likely to mature in the next 5 years into working systems; PCR-based methods cannot distinguish between DNA or RNA of a viable microorganism and that of a non-viable organism. This may or may not be an important issue with reclaimed water on the ISSA. The recycling system probably damages the capacity of the genetic material of any bacteria or viruses killed during processing to serve as a template in a PCR desinged to amplify a large segment of DNA (less than 650 base pairs). If necessary, vital dye staining could be used in addition to PCR, to enumerate the viable cells in a water sample; The quality control methods have been developed to insure that PCR's are working properly, and that reactions are not contaminated with PCR carryover products which could lead to the generation of false-positive results; and The sequences of the small rRNA subunit gene for a large number of microorganisms are known, and they consititue the best database for rational development of the oligonucleotide reagents that give PCR its great specificity. From those gene sequences, sets of oligonucleotide primers for PCR and Taqman detection that could be used in a NASA microbial monitor were constructed using computer based methods. In addition to space utilization, a microbial monitior will have tremendous terrestrial applications. Analysis of patient samples for microbial pathogens, testing industrial effluent for biofouling bacteria, and detection biological warfare agents on the battlefield are but a few of the diverse potential uses for this technology. Once fully developed, gene-based microbial monitors will become the fundamental tool in every lab that tests for microbial contaminants, and serve as a powerful weapon in mankind's war with the germ world.

Cassell, Gail H.↗

Determination of cellulose crystallinity from powder diffraction diagrams: Powder Diffraction Diagrams

Commonly one-dimensional (1D) (spherically averaged) powder diffraction diagrams are used to determine the degree of cellulose crystallinity in biomass samples. Here, it is shown using molecular modeling how disorder in cellulose fibrils can lead to considerable uncertainty in conclusions drawn concerning crystallinity based on 1D powder diffraction data alone. For example, cellulose microfibrils that contain both crystalline and noncrystalline segments can lead to powder diffraction diagrams lacking identifiable peaks, while microfibrils without any crystalline segments can lead to such peaks. Moreover, this leads to false positives, that is, assigning disordered cellulose as crystalline, and false negatives, that is, categorizing fibrils with crystalline segments as amorphous. Finally, the reliable determination of the fraction of crystallinity in any given biomass sample will require a more sophisticated approach combining detailed experiment and simulation.

36 MATERIALS SCIENCE↗

Phosphodiesterase (PDE5) inhibition assay for rapid detection of erectile dysfunction drugs and analogs in sexual enhancement products

Abstract Products marketed as dietary supplements for sexual enhancement are frequently adulterated with phosphodiesterase‐5 (PDE5) inhibitors, which are erectile dysfunction drugs or their analogs that can cause adverse health effects. Due to widespread adulteration, a rapid screening assay was developed to detect PDE5 inhibitors in adulterated products. The assay employs fluorescence detection and is based on measuring inhibition of PDE5 activity, the pharmacological mechanism shared among the adulterants. Initially, the assay reaction scheme was established and characterized, followed by analysis of 9 representative PDE5 inhibitors ( IC 50 , 0.4–4.0 ng mL –1 ), demonstrating sensitive detection in matrix‐free solutions. Next, dietary supplements serving as matrix blanks ( n = 25) were analyzed to determine matrix interference and establish a threshold value; there were no false positives. Finally, matrix blanks were spiked with 9 individual PDE5 inhibitors, along with several mixtures. All 9 adulterants were successfully detected (≤ 5 % false negative rate; n = 20) at a concentration of 1.00 mg g –1 , which is over 5 times lower than concentrations commonly encountered in adulterated products. A major distinction of the PDE5 inhibition assay is the ability to detect adulterants without prior knowledge of their chemical structures, demonstrating a broad‐based detection capability that can address a continuously evolving threat of new adulterants. The PDE5 inhibition assay can analyze over 40 samples simultaneously within 15 minutes and involves a single incubation step and simple data analysis, all of which are advantageous for combating the widespread adulteration of sex‐enhancement products.

Santillo, Michael F.↗

Estimating dermal contact soil exposure for amphibians

Abstract Chemical exposure estimation through the dermal route is an underemphasized area of ecological risk assessment for terrestrial animals. Currently, there are efforts to create exposure models to estimate doses from this pathway for use in ecological risk assessment. One significant limitation has been insufficient published data to characterize exposure and to support the selection and parameterization of appropriate models, particularly for amphibians in terrestrial habitats. Recent publications measuring pesticide doses to terrestrial‐phase amphibians have begun to rectify this situation. We collated and summarized available measurements of terrestrial amphibian dermal exposure to pesticides from 11 studies in which researchers measured tissue concentrations associated with known pesticide experimental application rates. This data set included tissue concentrations in 11 amphibian species and 14 different pesticides. We then compared the results of two screening exposure models that differed based on surface area scaling approaches as a function of body weight (one based on birds as surrogates for amphibians and another amphibian‐specific) to the measured tissue residue concentrations. We define a false‐negative rate for each screening model as the proportion of amphibians for which the predicted concentration is less than the observed concentration (i.e., underestimate), contrary to the intent of screening models, which are intended to have a bias for higher exposure concentrations. The screening model that uses birds as surrogates did not have any instances where estimated expected avian doses were less than measured amphibian body burdens. When using the amphibian‐specific exposure model that corrected for differences between avian and amphibian surface area, measured concentrations were greater than model estimates for 11.3% of the 1158 comparisons. The database of measured pesticide concentrations in terrestrial amphibians is provided for use in calculating bioconcentration factors and for future amphibian dermal exposure model development. Integr Environ Assess Manag 2023;19:9–16. © 2022 SETAC. This article has been contributed to by U.S. Government employees and their work is in the public domain in the USA.

Environmental Sciences & Ecology↗

Inferring precocial Chinook Salmon production through single‐parentage assignments

Abstract Objective Parentage analysis is a routine methodology in fisheries research, but study systems exist where it is impractical to sample both parents. The ability to reliably assign offspring to a single parent is beneficial in these situations. We applied single‐parentage assignments to a naturally spawning population of Chinook Salmon Oncorhynchus tshawytscha to quantify production of anadromous returns by unsampled precocial males. Methods We used an approach that focused on two important aspects of parentage analyses: (1) addressing the presence of family structure within the set of sampled parents and (2) controlling for false‐positive and false‐negative assignments. Result Results indicated that 30% of reproductively successful males were precocial males, which produced 20% of the returning anadromous offspring. Conclusion This study provides a framework for applying single‐parent assignments in a salmonid study system while explicitly addressing sources of assignment errors.

Steele, Craig A.↗

Imaging post-stereotactic body radiation therapy responses for hepatocellular carcinoma: typical imaging patterns and pitfalls

Stereotactic body radiation therapy (SBRT) has increased utility in the management of hepatocellular carcinoma (HCC) ranging from local therapy in early-stage HCC not suitable for other focal therapies to end-stage HCC. As the indications for the use of SBRT in HCC expand, diagnostic imaging is being increasingly used to assess response to treatment. The imaging features of tumor response do not parallel those of other focal therapies such as radiofrequency ablation or trans-arterial chemoembolization that immediately devascularize the tumor. The tumor response to SBRT on imaging takes much longer and often shows gradual changes including the reduction of enhancement and size over several months. It is essential to recognize the typical imaging patterns of response, as well as the appearance of focal liver reaction in the non-target liver that can confound image interpretation. The timing of treatment response assessment imaging is fundamental to minimize the potential for false negative response. The purpose of this article is to review the variable post-SBRT imaging features of HCC and adjacent liver parenchyma and discuss the potential pitfalls of imaging evaluation after SBRT for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗