Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Impact fracture of composite sandwich structures

An experimental investigation of impact-initiated failures in high-strength graphite/epoxy and Kevlar-49/epoxy sandwich structures has been conducted. The tests consisted of firing small diameter aluminum projectiles with a velocity range of 16-67 meters/second (52-220 ft/sec) at preloaded sandwich specimens. These tests were intended to be representative of service conditions on materials and structures which might be used as secondary aircraft components. The preload and impact energy necessary to initiate catastrophic failure were determined. The residual strength of impact-damaged specimens was also measured. The results of these tests indicate that catastrophic failures in sandwich structures can be initiated at relatively low preloads by impact projectiles at energy levels well below that required to initiate visible damage.

Rhodes, M. D.↗

Loading rate sensitivity of open hole composites in compression

The results are reported of an experimental study on the compressive, time-dependent behavior of graphite fiber reinforced polymer composite laminates with open holes. The effect of loading rate on compressive strength was determined for six material systems ranging from brittle epoxies to thermoplastics at both 75 F and 220 F. Specimens were loaded to failure using different loading rates. The slope of the strength versus elapsed time-to-failure curve was used to rank the materials' loading rate sensitivity. All of the materials had greater strength at 75 F than at 220 F. All the materials showed loading rate effects in the form of reduced failure strength for longer elapsed-time-to-failure. Loading rate sensitivity was less at 220 F than the same material at 70 F. However, C12000/ULTEM and IM7/8551-7 were more sensitive to loading rate than the other materials at 220 F. AS4/APC2 laminates with 24, 32, and 48 plies and 1/16 and 1/4 inch diameter holes were tested. The sensitivity to loading rate was less for either increasing number of plies or larger hole size. The failure of the specimens made from brittle resins was accompanied by extensive delaminations while the failure of the roughened systems was predominantly by shear crippling. Fewer delamination failures were observed at the higher temperature.

Lubowinski, Steve J.↗

Loading rate sensitivity of open-hole composite specimens in compression

The results are reported of an experimental study on the compressive, time-dependent behavior of graphite fiber reinforced polymer composite laminates with open holes. The effect of loading rate on compressive strength was determined for six material systems ranging from brittle epoxies to thermoplastics at both 75 F and 220 F. Specimens were loaded to failure using different loading rates. The slope of the strength versus elapsed time-to-failure curve was used to rank the materials' loading rate sensitivity. All of the materials had greater strength at 75 F than at 220 F. All the materials showed loading rate effects in the form of reduced failure strength for longer elapsed-time-to-failure. Loading rate sensitivity was less at 220 F than the same material at 70 F. However, C12000/ULTEM and IM7/8551-7 were more sensitive to loading rate than the other materials at 220 F. AS4/APC2 laminates with 24, 32, and 48 plies and 1/16 and 1/4 inch diameter holes were tested. The sensitivity to loading rate was less for either increasing number of plies or larger hole size. The failure of the specimens made from brittle resins was accompanied by extensive delaminations while the failure of the roughened systems was predominantly by shear crippling. Fewer delamination failures were observed at the higher temperature.

Lubowinski, S. J.↗

Geomechanical Characterization of Geo-architectured Rock Specimens Using Gypsum-based 3D Printing

Due to natural heterogeneity in rock specimens, classifying rock characteristics can present difficulties. 3D printing geo-architectured rock specimens has the potential to reduce the heterogeneity and help evaluate characteristics with reproducible microstructures, bedding, and strength to advance mechanical interpretations. This testing focused on 3D printing effects on strength and rock behavior by varying amount of binder, printing direction, and atmospheric conditions. A powder-based Gypsum 3D printer was used to create 1.5-inch diameter cylindrical samples. Unconfined compressive strength (UCS) testing was completed on these samples to gather failure plots and peak strength. Multiple batches of cylindrical samples were printed with varying printing direction, binder amount, and atmospheric conditions. UCS results show that the strongest samples were those that were printed perpendicular to the loading direction compared to those printed parallel or 45 degrees. Due to reactions of the printing material with water, those at dry conditions were the strongest. Samples with the most binder amount proved to also be stronger than those with less. 3D printing of rock samples has to the potential to reduce heterogeneity rock presents, however additional factors introduced by the printing process can affect overall rock strength and behavior. Test results of the 3D printed geo-architected rock specimens demonstrated reasonable reproducibility and appear to be a promising path towards increasing the ability to characterize natural rock.

36 MATERIALS SCIENCE↗

Irradiation of three T-111 clad uranium nitride fuel pins for 8070 hours at 990 C (1815 F)

The design and successful operation of three tantalum alloy (Ta-8W-2Hf) clad uranium mononitride (UN) fuel pins irradiated for 8070 hr at 990 C (1815 F) is described. Two pin diameters having measured burnups of 0.47 and 0.90 uranium atom percent were tested. No clad failures or swelling was detected; however, postirradiation clad samples tested failed with 1 percent strain. The fuel density decrease was 2 percent, and the fission gas release was less than 0.05 percent. Isotropic fuel swelling, which averaged about 0.5 percent, was less than fuel pin assembly clearances. Thus the clad was not strained. Thermocouples with a modified hot zone operated at average temperatures to 1100 C (2012 F) without failure. Factors that influence the ability to maintain uniform clad temperature as well as the results of the heat transfer calculations are discussed.

Slaby, J. G.↗

Buckling test of a 3-meter-diameter corrugated graphite-epoxy ring-stiffened cylinder

A three m diameter by three m long corrugated cylindrical shell with external stiffening rings was tested to failure by buckling. The corrugation geometry for the graphite epoxy composite cylinder wall was optimized to withstand a compressive load producing an ultimate load intensity of 157.6 kN/m without buckling. The test method used to produce the design load intensity was to mount the specimen as a cantilevered cylinder and apply a pure bending moment to the end. A load introduction problem with the specimen was solved by using the BOSOR 4 shell of revolution computer code to analyze the shell and attached loading fixtures. The cylinder test loading achieved was 101 percent of design ultimate, and the resulting mass per unit of shell wall area was 1.96 kg/sq m.

Davis, R. C.↗

LISA Technology Development and Risk Reduction at NASA

The Laser Interferometer Space Antenna (LISA) is a joint ESA-NASA project to design, build and operate a space-based gravitational wave detector based on a laser interferometer. LISA relies on several technologies that are either new to spaceflight or must perform at levels not previously demonstrated in a spaceflight environment. The ESA-led LISA Pathfinder mission is the main effort to demonstrate LISA technology. NASA also supports complementary ground-based technology development and risk reduction activities. This presentation will report the status of NASA work on micronewton thrusters, the telescope, the optical pointing subsystem and mission formulation. More details on some of these topics will be given in posters. Other talks and posters will describe NASA-supported work on the laser subsystem, the phasemeter, and aspects of the interferometry. Two flight-qualified clusters of four colloid micronewton thrusters, each capable of thrust Levels between 5 and 30 microNewton with a resolution less than 0.l microNewton and a thrust noise less than 0.1 microNewton/vHz (0.001 to 4 Hz), have been integrated onto the LISA Pathfinder spacecraft. The complementary ground-based development focuses on lifetime demonstration. Laboratory verification of failure models and accelerated life tests are just getting started. LISA needs a 40 cm diameter, afocal telescope for beam expansion/reduction that maintains an optical pathlength stability of approximately 1 pm/vHz in an extremely stable thermal environment. A mechanical prototype of a silicon carbide primary-secondary structure has been fabricated for stability testing. Two optical assemblies must point at different distant spacecraft with nanoradian accuracy over approximately 1 degree annual variation in the angle between the distant spacecraft. A candidate piezo-inchworm actuator is being tested in a suitable testbed. In addition to technology development, NASA has carried out several studies in support of the mission formulation. The results of systems engineering work on flight software, avionics and reliability will be summarized.

Stebbins, Robin T.↗

Pressure Dome for High-Pressure Electrolyzer

A high-strength, low-weight pressure vessel dome was designed specifically to house a high-pressure [2,000 psi (approx. = 13.8 MPa)] electrolyzer. In operation, the dome is filled with an inert gas pressurized to roughly 100 psi (approx. = 690 kPa) above the high, balanced pressure product oxygen and hydrogen gas streams. The inert gas acts to reduce the clamping load on electrolyzer stack tie bolts since the dome pressure acting axially inward helps offset the outward axial forces from the stack gas pressure. Likewise, radial and circumferential stresses on electrolyzer frames are minimized. Because the dome is operated at a higher pressure than the electrolyzer product gas, any external electrolyzer leak prevents oxygen or hydrogen from leaking into the dome. Instead the affected stack gas stream pressure rises detectably, thereby enabling a system shutdown. All electrical and fluid connections to the stack are made inside the pressure dome and require special plumbing and electrical dome interfaces for this to be accomplished. Further benefits of the dome are that it can act as a containment shield in the unlikely event of a catastrophic failure. Studies indicate that, for a given active area (and hence, cell ID), frame outside diameter must become ever larger to support stresses at higher operating pressures. This can lead to a large footprint and increased costs associated with thicker and/or larger diameter end-plates, tie-rods, and the frames themselves. One solution is to employ rings that fit snugly around the frame. This complicates stack assembly and is sometimes difficult to achieve in practice, as its success is strongly dependent on frame and ring tolerances, gas pressure, and operating temperature. A pressure dome permits an otherwise low-pressure stack to operate at higher pressures without growing the electrolyzer hardware. The pressure dome consists of two machined segments. An O-ring is placed in an O-ring groove in the flange of the bottom segment and is trapped by the flange on the top dome segment when these components are bolted together with high-strength bolts. The pressure dome has several unique features. It is made (to ASME Pressure Vessel guidelines) in a high-strength aluminum alloy with the strength of stainless steel and the weight benefits of aluminum. The flange of the upper dome portion contains specially machined flats for mounting the dome, and other flats dedicated to the special feedthroughs for electrical connections. A pressure dome can be increased in length to house larger stacks (more cells) of the same diameter with the simple addition of a cylindrical segment. To aid in dome assembly, two stainless steel rings are employed. One is used beneath the heads of the high-strength bolts in lieu of individual hardened washers, and another is used instead of individual nuts. Like electrolyzers could be operated at low or high pressures simply by operating the electrolyzer outside or inside a pressurized dome.

Norman, Timothy↗

Tension strength of a thick graphite/epoxy laminate after impact by a 1/2-in. radius impactor

NASA is developing graphite/epoxy filament-wound cases for solid rocket motors of the space shuttle. They are wet-wound with AS4W graphite fiber and HBRF-55A epoxy. The membrane region is about 1.4 inches thick. Two 30-inch-diameter by 12-inch-long cylinders were impacted every two inches of circumference with 1/2-inch radius impactors that were dropped from various heights. One cylinder was empty and the other was filled with inert propellant. Two-inch-wide test specimens were cut from the cylinders. Each was centered on an impact site. The specimens were x-rayed and loaded to failure in uniaxial tension. Rigid body mechanics and the Hertz law were used to predict impact force, local deformations, contact diameters, and contact pressures. The depth of impact damage was predicted using Love's solution for pressure applied on part of the boundary of a semi-infinite body. The predictions were reasonably good. The strengths of the impacted specimens were reduced by as much as 37 percent without visible surface damage. Even the radiographs did not reveal the nonvisible damage.

Poe, C. C., Jr.↗

Torsion of Noncircular Composite Cylinders

The paper presents a brief overview of the predicted deformation and failure characteristics of noncircular composite cylinders subjected to torsion. Using a numerical analysis, elliptical cylinders with a minor-to-major diameter ratio of 0.7 are considered. Counterpart circular cylinders with the same circumference as the elliptical cylinders are included for comparison. The cylinders are constructed of a medium-modulus graphite-epoxy material in a quasi-isotropic lay-up. Imperfections generated from the buckling mode shapes are included in the initial cross-sectional geometry of the cylinders. Deformations until first fiber failure, as predicted using the maximum stress failure criterion and a material degradation scheme, are presented. For increasing levels of torsion, the deformations of the elliptical cylinders, in the form of wrinkling of the cylinder wall, occur primarily in the flatter regions of the cross section. By comparison the wrinkling deformations of the circular cylinders are more uniformly distributed around the circumference. Differences in the initial failure and damage progression and the overall torque vs. twist relationship between the elliptical and circular cylinders are presented. Despite differences in the response as the cylinders are being loaded, at first fiber failure the torque and twist for the elliptical and circular cylinders nearly coincide.

Rouse, Marshall↗

Design and Analysis of an Integrated Additively Manufactured Test Article for Plasma-Facing Components

Current plasma-facing components (PFCs) used in helium-cooled divertor modules are complex structures with tungsten tile, steel sleeve components, and cartridges, all assembled in a helium-cooled multiple jet (HEMJ) structure. The goal of this project is to simplify the complex PFC design using additive manufacturing techniques to create a single integrated tungsten test article. Apart from the flexibility this opens up in exploring a wide array of geometries for the article, having a single integrated article significantly reduces the number of joints and parts in the article, thus reducing chances of leaks. A process called electron beam melting has shown to produce very high-density samples and unique geometries, enabling HEMJ or similar designs. To validate and optimize this novel design, the model underwent a series of computational fluid dynamics and finite element analysis simulations to replicate steady-state heat flux in the divertors. The simulations presented in this study consider a steady-state base heat flux of 5 MW/m 2 , with water serving as the coolant. Future research will explore the use of helium as a coolant, simulate edge-localized-mode conditions, and include experimental validation. Since 3D-printed tungsten is anisotropic, the build direction versus build plane of the article are taken into consideration for the test article strength. Because of the high operating temperatures and low ductility of tungsten, thermal creep and brittle fracture are important failure mechanisms to consider. In conclusion, the cap is evaluated with various flow velocities and nozzle diameters, and an optimal design choice is made for which this cap will survive the divertor conditions with a conservative safety margin.

Divertor↗

Experimental investigation of the crush performance of prepreg platelet molding compound tubes

This work presents an experimental study characterizing the crush performance of hollow cylindrical tubes made with prepreg platelet molding compound (PPMC). PPMC is a composite material system that uses platelets from chopped and slit unidirectional prepreg as the basis for a molding compound. This material system has a higher fiber volume fraction and better mechanical properties than traditional short fiber systems and can be molded into complex geometries unlike continuous fiber systems. As such, this material system shows promise for use with complex structural members in vehicles. The failure morphology and specific energy absorption of the material are evaluated with different thickness-to-diameter geometries and test speeds. In addition, this work investigates how PPMC components compare to traditional continuous fiber components and finds that PPMC performs as well as continuous fiber layups with similar effective laminate stiffnesses.

Materials Science↗

Buckling tests of a 10 foot diameter stiffened cylinder with rectangular cutouts

A 10-foot diameter aluminum cylinder with rectangular cutouts in its ring and stringer stiffened wall was loaded to failure by an end bending moment. A 24x27 inch cutout, centered on the compression side of the shell, was first cut into the cylinder. After testing, the cutout area was enlarged to a 36/36 inch square cutout that removed the material damaged by buckling during the first test. After the second buckling test, the cutout area was patched with an equivalent stiffness plate bolted over the cutout hole. The cylinder was rotated 120 deg. and a 18x18 inch square hole cut into the center of the new compression side of the shell. Test specimen details, test procedures, and test results are presented.

Davis, Randall C.↗

Mechanically fastened joints in woven fabric composites

Strength analysis for composite bolted joints involves the mating of a stress analysis with an appropriate mode specific failure criterion for each of the primary failure modes. The stress analysis and failure criteria are independent of each other and can be manipulated separately in order to optimize the strength analysis package formed by their coupling. Material properties tests were conducted on rubber toughened graphite-epoxy material to measure the basic strength and stiffness in the warp and fill directions and in shear. Test matrices are summarized for investigations of laminate configuration, stacking sequence, fastener diameter, edge distance, fastener half spacing, laminate thickness, and fastener torque. A three dimensional finite element analysis computer program was written and failure criteria for net tension, shearout, and bearing were determined.

Wilson, D. W.↗

SU-C-BRD-02: A Team Focused Clinical Implementation and Failure Mode and Effects Analysis of HDR Skin Brachytherapy Using Valencia and Leipzig Surface Applicators

Purpose: and Leipzig applicators (VLAs) are single-channel brachytherapy surface applicators used to treat skin lesions up to 2cm diameter. Source dwell times can be calculated and entered manually after clinical set-up or ultrasound. This procedure differs dramatically from CT-based planning; the novelty and unfamiliarity could lead to severe errors. To build layers of safety and ensure quality, a multidisciplinary team created a protocol and applied Failure Modes and Effects Analysis (FMEA) to the clinical procedure for HDR VLA skin treatments. Methods: team including physicists, physicians, nurses, therapists, residents, and administration developed a clinical procedure for VLA treatment. The procedure was evaluated using FMEA. Failure modes were identified and scored by severity, occurrence, and detection. The clinical procedure was revised to address high-scoring process nodes. Results: Several key components were added to the clinical procedure to minimize risk probability numbers (RPN): -Treatments are reviewed at weekly QA rounds, where physicians discuss diagnosis, prescription, applicator selection, and set-up. Peer review reduces the likelihood of an inappropriate treatment regime. -A template for HDR skin treatments was established in the clinical EMR system to standardize treatment instructions. This reduces the chances of miscommunication between the physician and planning physicist, and increases the detectability of an error during the physics second check. -A screen check was implemented during the second check to increase detectability of an error. -To reduce error probability, the treatment plan worksheet was designed to display plan parameters in a format visually similar to the treatment console display. This facilitates data entry and verification. -VLAs are color-coded and labeled to match the EMR prescriptions, which simplifies in-room selection and verification. Conclusion: Multidisciplinary planning and FMEA increased delectability and reduced error probability during VLA HDR Brachytherapy. This clinical model may be useful to institutions implementing similar procedures.

60 APPLIED LIFE SCIENCES↗

TSS tether cable meteoroid/orbital debris damage analysis

This report summarizes the damage analyses performed on the tether cable used for the tethered satellite system (TSS), for the damage that could be caused by meteoroid or orbital debris impacts. The TSS consists of a tethered satellite deployer and a tethered satellite. The analytical studies were performed at Marshall Space Flight Center (MSFC) with the results from the following tests: (1) hypervelocity impact tests to determine the 'critical' meteoroid particle diameter, i.e., the maximum size of a meteoroid particle which can impact the tether cable without causing 'failure'; (2) electrical resistance tests on the damaged and undamaged tether cable to determine if degradation of current flow occurred through the damaged tether cables; and (3) tensile load tests to verify the load carrying capability of the damaged tether cables. Finally, the HULL hydrodynamic computer code was used to simulate the hypervelocity impact of the tether cable by particles at velocities higher than can be tested, to determine the extent of the expected tether damage.

Hayashida, K. B.↗

Overview of Micrometeoroid and Orbital Debris Analysis Process for Mars Sample Return Earth Entry System

Introduction: Micrometeoroid and orbital debris (MMOD) risk analyses for the Mars Sample Return (MSR) Earth Entry System (EES) have been significantly more rigorous than previously flown missions because of its categorization as a Class V restricted return mission. This means the returned samples present significant concern for biogenic contamination. These analyses seek to determine if a micrometeoroid or orbital debris strike would result in loss of containment assurance and are summarized in the flowchart in Fig. 1. Methodology: The mission is considered in two MMOD phases: a pre-release phase where the EES is protected by a Micrometeoroid Protection System (MMPS) and a post-release phase called “free-flight” where the EES is exposed directly to the MMOD environment. These phases correspond to interplanetary cruise and imminent re-entry, respectively. To inform the MMPS design, a 30-shot high velocity impact testing (HVIT) series on candidate configurations at NASA White Sands Test Facility was completed in the summer of 2022. Sample post-shot images are shown in Fig 2 [1]. These data are used to baseline the MMPS design and to tune the hydrocode simulations. ALE3D, CTH, and SPHC are the hydrocodes that simulate physics of high-speed impacts [2]. Results generated with these populate a penetration depth versus energy space beyond the testable velocity regime of HVIT (~7 km/s). The penetration depth versus energy space data are used to define a critical projectile diameter function called a Ballistic Limit Equation (BLE), where the projectile “criticality” is determined by zone dependent failure criteria defined a-priori [3]. For example, the nose of the heatshield has a failure criterion of 50% TPS penetration, assigned because the landing loads are concentrated on that region and no substructure damage is permitted. The BLEs for each vehicle material zone are input into the BUMPER 3 code, along with the vehicle surface mesh and the corresponding space environment model, to calculate a probability of penetration or number of penetrations. The environment models, MEM3 for MM and ORDEM 3.2 for OD, simulate the meteoroid environment from 0.2 to 2 au based on the Grün flux equation, and the debris environment up to 40,000 km altitude from Earth surface, respectively [4,5]. Presentation Focus: The presentation or poster will present the results to-date focusing on the full risk analysis process flow seen in Fig. 1. Details on the derivation of the failure criteria will be discussed, along with HVIT results and how these influenced the MMPS configuration baseline decision. Further, results of hydrocode simulations will be presented and the tuning to HVIT outputs will be described. Finally, the strategies that direct the BLE formulation will be reviewed, specifically, for the EES elements that are most exposed to the MMOD environment.

mmod↗

Metallurgical Failure Analysis of A2 Tool Steel Die Set from High Explosive Pellet Pressing Event

On 2 April 2018, a high explosive violent reaction (HEVR) occurred during routine pressing of a 1-in -diameter cylindrical pellet of PBX 9501 high explosive. Fragments of the die set (die body and stemples) involved in the event were sent to Sigma Division for metallurgical analysis. A handheld x-ray fluorescence alloy tester confirmed the die set material to be A2 tool steel. Light optical microscopy revealed what appear to be pre-existing flaws on the inner diameter of the die body. Scanning Electron Microscopy could neither confirm nor exclude the presence of fatigue cracking in the vicinity of these potential flaws. Energy Dispersive Spectroscopy indicated the presence of a carbon-bearing residue on fracture surfaces; nitrogen-bearing residue was also found. Optical microscopy revealed that the microstructure of the stemple and inner diameter of the die body contained large stringers and non-uniform grain size; this was distinct from the relatively clean and uniform microstructure seen at the outer diameter of the die body, and also other A2 tool steel stock (pedigree unknown and with no known connection to any HE pressing hardware) that was examined for additional comparison. Rockwell hardness testing indicated the material was heat treated properly. Metallographic analysis alone could not positively identify the root cause of the event, but, coupled with accounts provided by the operator and the successful history with the particular lot of HE involved in the event, points to ward mechanical failure of the die set due to pre -existing flaw as the most likely precipitating event. Suggestions for additional analyses and future qualification techniques are discussed.

36 MATERIALS SCIENCE↗