Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “extractants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Shuttle seated extraction feasibility study

Following the Space Shuttle Challenger accident, serious attention has turned to in-flight escape. Prior to the resumption of flight, a manual bailout system was qualified and installed. For the long term, a seated extraction system to expand the escape envelope is being investigated. This paper describes a 1987 study, conducted jointly by NASA/Johnson Space Center and Langley Research Center, to determine the feasibility of modifying the Space Shuttle Orbiters to incorporate the seated extraction system. Results of the study are positive, indicating retrofit opportunity and high probability of escape for early ascent, late entry, and even for uncontrolled flight such as the Challenger breakup. The system, as envisioned, can extract seven crewmembers within two seconds.

Onagel, Steven R.↗

A procedure for the extraction of airglow features in the presence of strong background radiation

A technique is developed that can be used to derive the total intensity of band emissions from twilight airglow measurements when the basic spectral signature of the band to be considered is known. The method is designed to automatically extract total band or line intensities of a signal imbedded in background radiation several orders of magnitude greater in brightness. It is shown that the technique developed can reliably measure the intensity of both weak and strong band and line emissions in the presence of strong twilight background radiation. The method of extraction is shown as part of a general purpose spectral analysis program written in VAX FORTRAN. This extraction procedure has been used successfully on emissions of Fel, Ca(+), N2(+) (1N) (0-0) and (0-1), OH in the near UV. OI red (630nm) and green (558nm) lines in the visible, and the OH Meinel bands and O(+) (2P) 732 nm in the near IR.

Swift, W. R.↗

Effects of bleed air extraction on thrust levels on the F404-GE-400 turbofan engine

A ground test was performed to determine the effects of compressor bleed flow extraction on the performance of F404-GE-400 afterburning turbofan engines. The two engines were installed in the F/A-18 High Alpha Research Vehicle at the NASA Dryden Flight Research Facility. A specialized bleed ducting system was installed onto the aircraft to control and measure engine bleed airflow while the aircraft was tied down to a thrust measuring stand. The test was conducted on each engine and at various power settings. The bleed air extraction levels analyzed included flow rates above the manufacturer's maximum specification limit. The measured relationship between thrust and bleed flow extraction was shown to be essentially linear at all power settings with an increase in bleed flow causing a corresponding decrease in thrust. A comparison with the F404-GE-400 steady-state engine simulation showed the estimation to be within +/- 1 percent of measured thrust losses for large increases in bleed flow rate.

Yuhas, Andrew J.↗

Vacancy formation and extraction energies in semiconductor compounds and alloys

A model for calculating the extraction energies and vacancy-formation energies in diamond-cubic and zinc-blende semiconductors is developed on the basis of Harrison's (1980, 1983) tight-binding theory. The extraction energies provide a reference from which other final states of the removed atoms can be calculated. The results of calculations show that, in a given compound, the calculated extraction energies are larger for the anion than for the cation, with the difference between the cation and the anion being larger in the II-VI than in the III-V compounds. This is in agreement with experimental results.

Berding, M. A.↗

Effects of bleed air extraction of thrust levels on the F404-GE-400 turbofan engine

A ground test was performed to determine the effects of compressor bleed flow extraction on the performance of F404-GE-400 afterburning turbofan engines. The two engines were installed in the F/A-18 High Alpha Research Vehicle at the NASA Dryden Flight Research Facility. A specialized bleed ducting system was installed onto the aircraft to control and measure engine bleed airflow while the aircraft was tied down to a thrust measuring stand. The test was conducted on each engine and at various power settings. The bleed air extraction levels analyzed included flow rates above the manufacturer's maximum specification limit. The measured relationship between thrust and bleed flow extraction was shown to be essentially linear at all power settings with an increase in bleed flow causing a corresponding decrease in thrust. A comparison with the F404-GE-400 steady-state engine simulation showed the estimation to be within +/- 1 percent of measured thrust losses for large increases is bleed flow rate.

Yuhas, Andrew J.↗

Beneficiation and extraction of nonterrestrial materials, part 2

A review of options for processing extraterrestrial materials was dominated by industrial materials scientist who tried to identify which processes utilizing space materials could be implemented in the near term. The most practical process seem to us to be the extraction of lunar oxygen and the extraction of metals and ceramics from the residues of the reduction process. The growth of space activity will be accompanied by increased demand for liquid oxygen for each round trip to the Moon. The oxygen and the intermediary product water will be needed for the life support at the base. The reduced metals and ceramics may be considered byproducts or may develop into primary products. Some of the same processes would be directly applicable to recovery of products from asteroids. We also discussed other processes for directly utilizing asteroid metals. Some of the topics covered include beneficiation and oxygen extraction methods, metallurgy, and extraterrestrial cement.

Agosto, William N.↗

A robust line extraction and matching algorithm

This paper presents an algorithm for extracting straight lines from intensity mages and describes a line matching algorithm for solving the line correspondence problem. The line extraction process begins by detecting edges in the intensity image. Next, line support regions are formed where image points (pixels) have similar gradient orientation. A line fitting algorithm is then used to fit a line to the points in the line support region based on a least means square fitting algorithm. Finally, line segments are linked together to form the final lines by using an adaptive line linking method; this results in much stronger lines and a smaller set of lines to be considered. Once the lines are detected in a sequence of images, a line matching algorithm is used to match lines in one image to the lines in the other image. The images are either from a motion or stereo sequence. The matched lines may then be used with the sensor position and orientation data to estimate range to objects corresponding to the lines. We present results based on applying the line extraction and line matching algorithms to a synthetic image and an outdoor scene captured by a camera on a helicopter.

Hussien, B.↗

An algorithm for extraction of periodic signals from sparse, irregularly sampled data

Temporal gaps in discrete sampling sequences produce spurious Fourier components at the intermodulation frequencies of an oscillatory signal and the temporal gaps, thus significantly complicating spectral analysis of such sparsely sampled data. A new fast Fourier transform (FFT)-based algorithm has been developed, suitable for spectral analysis of sparsely sampled data with a relatively small number of oscillatory components buried in background noise. The algorithm's principal idea has its origin in the so-called 'clean' algorithm used to sharpen images of scenes corrupted by atmospheric and sensor aperture effects. It identifies as the signal's 'true' frequency that oscillatory component which, when passed through the same sampling sequence as the original data, produces a Fourier image that is the best match to the original Fourier space. The algorithm has generally met with succession trials with simulated data with a low signal-to-noise ratio, including those of a type similar to hourly residuals for Earth orientation parameters extracted from VLBI data. For eight oscillatory components in the diurnal and semidiurnal bands, all components with an amplitude-noise ratio greater than 0.2 were successfully extracted for all sequences and duty cycles (greater than 0.1) tested; the amplitude-noise ratios of the extracted signals were as low as 0.05 for high duty cycles and long sampling sequences. When, in addition to these high frequencies, strong low-frequency components are present in the data, the low-frequency components are generally eliminated first, by employing a version of the algorithm that searches for non-integer multiples of the discrete FET minimum frequency.

Wilcox, J. Z.↗

3D Feature Extraction for Unstructured Grids

Visualization techniques provide tools that help scientists identify observed phenomena in scientific simulation. To be useful, these tools must allow the user to extract regions, classify and visualize them, abstract them for simplified representations, and track their evolution. Object Segmentation provides a technique to extract and quantify regions of interest within these massive datasets. This article explores basic algorithms to extract coherent amorphous regions from two-dimensional and three-dimensional scalar unstructured grids. The techniques are applied to datasets from Computational Fluid Dynamics and those from Finite Element Analysis.

Silver, Deborah↗

Analysis of Supercritical-Extracted Chelated Metal Ions From Mixed Organic-Inorganic Samples

Organic and inorganic contaminants of an environmental sample are analyzed by the same GC-MS instrument by adding an oxidizing agent to the sample to oxidize metal or metal compounds to form metal ions. The metal ions are converted to chelate complexes and the chelate complexes are extracted into a supercritical fluid such as CO2. The metal chelate extract after flowing through a restrictor tube is directly injected into the ionization chamber of a mass spectrometer, preferably containing a refractory metal filament such as rhenium to fragment the complex to release metal ions which are detected. This provides a fast, economical method for the analysis of metal contaminants in a sample and can be automated. An organic extract of the sample in conventional or supercritical fluid solvents can be detected in the same mass spectrometer, preferably after separation in a supercritical fluid chromatograph.

Sinha, Mahadeva P.↗

Optimal Extraction with Sub-sampled Line-Spread Functions

STIS long-slit medium resolution spectra reduced in CALSTIS extended-source mode with narrow extraction heights (GWIDTH=3 pixels) show photometric uncertainties of +/- 3% relative to point-source extractions. These uncertainties are introduced through interpolation in the spectral image rectification processing stage, and are correlated with the number of pixel crossings the spectral profile core encounters in the spatial direction. The line-spread-function may be determined as a function of pixel crossing- position from calibration data sub-sampled in the spatial direction. This line spread function will be applied to science data to perform optimal extractions and point- source de-blending. Wavelength and breathing effects will be studied. Viability of the method to de-convolve extended source 'blobs' will be investigated.

Collins, Nicholas R.↗

Extraction of Airport Features from High Resolution Satellite Imagery for Design and Risk Assessment

The LPA Group, consisting of 17 offices located throughout the eastern and central United States is an architectural, engineering and planning firm specializing in the development of Airports, Roads and Bridges. The primary focus of this ARC project is concerned with assisting their aviation specialists who work in the areas of Airport Planning, Airfield Design, Landside Design, Terminal Building Planning and design, and various other construction services. The LPA Group wanted to test the utility of high-resolution commercial satellite imagery for the purpose of extracting airport elevation features in the glide path areas surrounding the Columbia Metropolitan Airport. By incorporating remote sensing techniques into their airport planning process, LPA wanted to investigate whether or not it is possible to save time and money while achieving the equivalent accuracy as traditional planning methods. The Affiliate Research Center (ARC) at the University of South Carolina investigated the use of remotely sensed imagery for the extraction of feature elevations in the glide path zone. A stereo pair of IKONOS panchromatic satellite images, which has a spatial resolution of 1 x 1 m, was used to determine elevations of aviation obstructions such as buildings, trees, towers and fence-lines. A validation dataset was provided by the LPA Group to assess the accuracy of the measurements derived from the IKONOS imagery. The initial goal of this project was to test the utility of IKONOS imagery in feature extraction using ERDAS Stereo Analyst. This goal was never achieved due to problems with ERDAS software support of the IKONOS sensor model and the unavailability of imperative sensor model information from Space Imaging. The obstacles encountered in this project pertaining to ERDAS Stereo Analyst and IKONOS imagery will be reviewed in more detail later in this report. As a result of the technical difficulties with Stereo Analyst, ERDAS OrthoBASE was used to derive aviation obstruction measurements for this project. After collecting ancillary data such as GPS locations, South Carolina Geodetic Survey and Aero Dynamics ground survey points to set up the OrthoBASE Block File, measurements were taken of the various glide path obstructions and compared to the validation dataset. This process yielded the following conclusions: The IKONOS stereo model in conjunction with Imagine OrthoBASE can provide The LPA Group with a fast and cost efficient method for assessing aviation obstructions. Also, by creating our own stereo model we achieved any accuracy better currently available commercial products.

Robinson, Chris↗

Rapid determination of ions by combined solid-phase extraction--diffuse reflectance spectroscopy

We introduce colorimetric solid-phase extraction (C-SPE) for the rapid determination of selected ions. This new technique links the exhaustive concentration of an analyte by SPE onto a membrane disk surface for quantitative measurement with a hand-held diffuse reflectance spectrometer. The concentration/measurement procedure is complete in approximately 1 min and can be performed almost anywhere. This method has been used to monitor iodine and iodide in spacecraft water in the 0.1-5.0 ppm range and silver(I) in the range of 5.0-1000 microg/l. Applications to the trace analysis of copper(II), nickel(II), iron(III) and chromium(VI) are described. Studies on the mechanism of extraction showed that impregnation of the disk with a surfactant as well as a complexing reagent results in uptake of additional water, which markedly improves the extraction efficiency.

NASA Program Advanced Human Support Technology↗

Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

NASA Center JSC↗

Extraction technique for the determination of oxygen-18 in water using preevacuated glass vials

The need for a rapid, inexpensive technique for routine 18O/16O extraction from water has arisen recently through applications in the medical sciences and in hydrology. The traditional experimental technique for determining the oxygen isotope composition of water, the CO2-H2O equilibration method, is tedious, time consuming, and involves the use of custom-made glass apparatus. Furthermore, because of potential memory effects from one sample to the next, the glassware needs to be thoroughly cleaned between runs. A few attempts have been made to improve upon the method. Attempts to analyze water directly in the source of the mass spectrometer produced large memory effects and questionable results. Commercially available apparatus for automated extraction of 18O/16O from water is generally prohibitively expensive and often is designed to interface only with the manufacturer's own mass spectrometer. The method described in this paper utilizes inexpensive, off-the-shelf, preevacuated, glass vials. Preevacuated vials have been used by others for the isotopic analysis of breath CO2 and are well tested. The vials can be purchased in bulk from scientific apparatus suppliers at a relatively low cost. These are coupled with a simplified extraction line consisting of a stainless steel syringe needle and a glass cold trap. Vials are filled with CO2 and H2O and shaken in a constant-temperature water bath for at least 90 min. Since the vials are discarded after use, no cleaning is necessary, essentially eliminating any memory effect. Reproducibility is generally better than +/- 0.05%. The only reagents required are gaseous CO2 for equilibration, a dry ice/alcohol mixture for trapping water, and liquid nitrogen for transferring the CO2.

NASA Discipline Number 52-10↗

Extraction of Profile Information from Cloud Contaminated Radiances

Clouds act to reduce the signal level and may produce noise dependence on the complexity of the cloud properties and the manner in which they are treated in the profile retrieval process. There are essentially three ways to extract profile information from cloud contaminated radiances: (1) cloud-clearing using spatially adjacent cloud contaminated radiance measurements, (2) retrieval based upon the assumption of opaque cloud conditions, and (3) retrieval or radiance assimilation using a physically correct cloud radiative transfer model which accounts for the absorption and scattering of the radiance observed. Cloud clearing extracts the radiance arising from the clear air portion of partly clouded fields of view permitting soundings to the surface or the assimilation of radiances as in the clear field of view case. However, the accuracy of the clear air radiance signal depends upon the cloud height and optical property uniformity across the two fields of view used in the cloud clearing process. The assumption of opaque clouds within the field of view permits relatively accurate profiles to be retrieved down to near cloud top levels, the accuracy near the cloud top level being dependent upon the actual microphysical properties of the cloud. The use of a physically correct cloud radiative transfer model enables accurate retrievals down to cloud top levels and below semi-transparent cloud layers (e.g., cirrus). It should also be possible to assimilate cloudy radiances directly into the model given a physically correct cloud radiative transfer model using geometric and microphysical cloud parameters retrieved from the radiance spectra as initial cloud variables in the radiance assimilation process. This presentation reviews the above three ways to extract profile information from cloud contaminated radiances. NPOESS Airborne Sounder Testbed-Interferometer radiance spectra and Aqua satellite AIRS radiance spectra are used to illustrate how cloudy radiances can be used in the profile retrieval process.

Smith, W. L.↗

Cutting Silica Aerogel for Particle Extraction

The detailed laboratory analyses of extraterrestrial particles have revolutionized our knowledge of planetary bodies in the last three decades. This knowledge of chemical composition, morphology, mineralogy, and isotopics of particles cannot be provided by remote sensing. In order to acquire these detail information in the laboratories, the samples need be intact, unmelted. Such intact capture of hypervelocity particles has been developed in 1996. Subsequently silica aerogel was introduced as the preferred medium for intact capturing of hypervelocity particles and later showed it to be particularly suitable for the space environment. STARDUST, the 4th NASA Discovery mission to capture samples from 81P/Wild 2 and contemporary interstellar dust, is the culmination of these new technologies. In early laboratory experiments of launching hypervelocity projectiles into aerogel, there was the need to cut aerogel to isolate or extract captured particles/tracks. This is especially challenging for space captures, since there will be many particles/tracks of wide ranging scales closely located, even collocated. It is critical to isolate and extract one particle without compromising its neighbors since the full significance of a particle is not known until it is extracted and analyzed. To date, three basic techniques have been explored: mechanical cutting, lasers cutting and ion beam milling. We report the current findings.

Tsou, P.↗

Planetary Airplane Extraction System Development and Subscale Testing

The Aerial Regional-scale Environmental Survey (ARES) project employs an airplane as the science platform from which to collect science data in the previously inaccessible, thin atmosphere of Mars. In order for the airplane to arrive safely in the Martian atmosphere a number of sequences must occur. A critical element in the entry sequence at Mars is an extraction maneuver to separate the airplane quickly (in less than a second) from its protective backshell to reduce the possibility of re-contact, potentially leading to mission failure. This paper describes the development, testing, and lessons learned from building a 1/3 scale model of this airplane extraction system. This design, based on the successful Mars Exploration Rover (MER) extraction mechanism, employs a series of trucks rolling along tracks located on the surface of the central parachute can. Numerous tests using high speed video were conducted at the Langley Research Center (LaRC) to validate this concept. One area of concern was that that although the airplane released cleanly, a pitching moment could be introduced. While targeted for a Mars mission, this concept will enable environmental surveys by aircraft in other planetary bodies with a sensible atmosphere such as Venus or Saturn s moon, Titan.

Teter, John E., Jr.↗