Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Comparison of Quinone-Based Catholytes for Aqueous Redox Flow Batteries and Demonstration of Long-Term Stability with Tetrasubstituted Quinones

Quinones are appealing targets as organic electrolytes for aqueous redox flow batteries (RFBs), but their utility continues to be constrained by limited stability under operating conditions. The present study evaluates the stability of a series water-soluble quinones, with redox potentials ranging from 605–885 mV vs. NHE, under acidic aqueous conditions (1 M H2SO4). Four of the quinones are examined as cathodic electrolytes in an aqueous RFB, paired with anthraquinone-2,7-disulfonate (AQDS) as the anodic electrolyte. The RFB data complement the solution stability measures and show that the most stable electrolyte is a tetrasubstituted quinone containing four sulfonated thioether substituents. The results highlight the importance of substituting all C–H positions of the quinone in order to maximize the quinone stability and set the stage for design of improve organic electrolytes for aqueous RFBs. The authors thank Joseph Fourie for assisting in the synthesis of compound 8. Financial support for this work was provided by the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences (SSS, TWR, JBG, CWA, YP), with supplemental contributions by the Wisconsin Alumni Research Foundation (WARF) through the WARF Accelerator Program (YQ and partial support for JBG, CWA, YP). NMR spectroscopy facilities were partially supported by the NSF (CHE-0342998 and CHE-1048642), a UW Madison Instructional Laboratory Modernization Award, and a gift from Paul J. and Margaret M. Bender.

aqueous flow batteries, quinones, organic, redox m↗

Irradiation effects in tungsten-copper laminate composite

Tungsten-copper laminate composite has shown promise as a structural plasma-facing component as compared to tungsten rod or plate. The present study evaluated the tungsten-copper composite after irradiation in the High Flux Isotope Reactor (HFIR) at temperatures of 410-780°C and fast neutron fluences of 0.02-9.0×1025 n/m2, E>0.1 MeV, 0.0039-1.76 displacements per atom (dpa) in tungsten. Tensile tests were performed on the composites, and the fracture surfaces were analyzed with scanning electron microscopy. Before irradiation, the tungsten layers had brittle cleavage failure, but the overall composite had 15.5% elongation at 22°C. After only 0.0039 dpa this was reduced to 7.7% elongation, and no ductility was observed after 0.2 dpa at all irradiation temperatures when tensile tested at 22°C. For elevated temperature tensile tests after irradiation, the composite only had ductile failure at temperatures where the tungsten was delaminating or ductile.

Garrison, L. M.↗

Data for Nitrogen Dynamics and Physiological N Use Efficiency in High-biomass Sorghum

Improving nitrogen (N) efficiency is essential for sustainable high-biomass sorghum ( Sorghum bicolor L. Moench ) production. This study evaluated leaf and stem N dynamics, canopy N remobilization, and physiological nitrogen use efficiency (pNUE) in two photoperiod-sensitive sorghum hybrids under two N rates (0 and 168 kg-N ha−1) across multiple environments in Texas and Illinois. Leaf N concentrations increased with plant height in the canopy with steeper gradients under low-N conditions, indicating enhanced N remobilization when N is limited. Stem tissue showed less variation in N concentration across canopy nodal positions, with within-plant differences ranging from 1.2 to 7.6 g kg−1, compared to 3.1 to 16.3 g kg−1 in leaves. While pNUE was generally higher under unfertilized conditions, it varied largely by site; however, genotypic differences were minimal within the given year. These results highlight the importance of integrating environmental and management factors into breeding and fertilization strategies to enhance N efficiency in high-biomass sorghum.

Nitrogen↗

Lead Speciation and In Vitro Bioaccessibility of Compost‐Amended Urban Garden Soils

In situ soil amendments can modify the Pb bioavailability by changing soil Pb speciation. Urban soils from three vegetable gardens containing different total Pb concentrations were used. The study evaluated how compost amendment and aging of soil‐compost mixture in situ affected the following: (i) soil Pb speciation in the field and (ii) change of soil Pb speciation during an in vitro bioaccessibility extraction mimicking gastric phase dissolution at pH 2.5. X‐ray absorption fine structure spectroscopy was used to determine Pb speciation in amended and nonamended soils and residues left after in vitro bioaccessibility extraction of those soils. Compost amendment and aging of compost in the field had a negligible effect on Pb bioaccessibility in the soils. Major Pb species in the soils were Pb sorbed to Fe oxy(hydr)oxide (Pb‐Fh) and to soil organic C (Pb‐Org). The fraction of Pb‐Org was increased as soil‐compost mixture aged in the field. During the in vitro extraction, the fraction of Pb‐Fh was decreased, the fraction of Pb‐Org was increased, and hydroxypyromorphite was formed in both amended and nonamended soils. Freshly incorporated compost enhanced the dissolution of Pb‐Fh during the extraction. As soil‐compost mixture aged in the field, the dissolution of Pb‐Fh was low, demonstrating more stability of the Pb‐Fh during the extraction. Compost amendment showed potential to contribute to reduced bioaccessibility of Pb as compost aged in the soil by increasing Pb‐Org fraction in the field and stability of Pb‐Fh during the in vitro bioaccessibility extraction. Core Ideas The dominant Pb species in the tested urban soils were Pb‐Fh and Pb‐Org. The fraction of Pb‐Org was increased as soil‐compost mixture aged. During the in vitro extraction, Pb‐Fh was dissolved, and Pb‐Org and HP were formed. aged soil‐compost mixture reduced pb‐fh dissolution during the in vitro extraction.

Attanayake, Chammi P.↗

The Accuracy of Inhomogeneity Corrections in Intensity Modulated Radiation Therapy Planning in Philips Pinnacle System

The degree of accuracy of inhomogeneity corrections in a treatment planning system is dependent on the algorithm used by the system. The choice of field size, however, could have an effect on the calculation accuracy as well. There have been several evaluation studies on the accuracy of inhomogeneity corrections used by different algorithms. Most of these studies, however, focus on evaluating the dose in phantom using simplified geometry and open/static fields. This work focuses on evaluating the degree of dose accuracy in calculations involving intensity-modulated radiation therapy (IMRT) fields incident on a phantom containing both lung- and bone-equivalent heterogeneities using 6 and 10 MV beams. IMRT treatment plans were generated using the Philips Pinnacle treatment planning system and delivered to a phantom containing 55 thermoluminescent dosimeter (TLD) locations within the lung and bone and near the lung and bone interfaces with solid water. The TLD readings were compared with the dose predicted by the planning system. We find satisfactory agreement between planned and delivered doses, with an overall absolute average difference between measurement and calculation of 1.2% for the 6 MV and 3.1% for the 10 MV beam with larger variations observed near the interfaces and in areas of high-dose gradient. The results presented here demonstrate that the convolution algorithm used in the Pinnacle treatment planning system produces accurate results in IMRT plans calculated and delivered to inhomogeneous media, even in regions that potentially lack electronic equilibrium.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modelling study to evaluate two variants for accessing a deep geological repository from the point of view of long-term safety

Siting a deep geological repository for radioactive waste essentially involves two interrelated steps: deciding on an appropriate geological environment for the underground facilities and selecting a suitable location for the associated surface facility. An acceptable solution is more easily achieved if some flexibility exists for siting the surface facility, irrespective of the exact position of the underground facilities. Such flexibility is available if a ramp is used as the main access route from the surface facility to the underground facilities. Another option is to use a combination of shafts and (sub)horizontal tunnels as the main access route. Both variants include shafts for ventilation, etc. In this paper, the two variants (i) main access via ramp and (ii) main access via shaft are compared in terms of long-term safety. To this end, the entire network of underground tunnels of a deep geological repository is implemented in an analytical resistor network flow model. Radionuclide release through the tunnel system and the host rock is then calculated with a numerical network transport model, using as input the results from the flow model. The results clearly indicate that, even in case of hypothetically deficient horizontal and sub-horizontal sealing elements, the choice between ramp and shaft as the main access route is irrelevant to long-term safety. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

100-OL-1 Operable Unit Pilot Study: XRF Evaluation of Select Pre-Hanford Orchards

Prior to the acquisition of land by the U.S. Department of War in February 1943 and the creation of the Hanford Site, the land along the Columbia River was home to over 1000 people. Farming and orchard operations by both homesteaders and commercial organizations were prevalent. Orchard activities and the associated application of lead arsenate pesticide ceased in 1943, when residents were moved from the Hanford Site at the beginning of the Manhattan Project. Today, the residues from historical application of lead arsenate pesticide persist in some locations on the Hanford Site

100-OL-1↗

Final Report to the U.S. Department of Energy for studies of Evaluation of Turbulence Parameterizations for Cloud-Resolving Models

The intermediately-prognostic higher-order turbulence closure (IPHOC) introduces a joint double-Gaussian distribution of liquid water potential temperature (θ l ), total water mixing ratio (q t ), and vertical velocity (w ) to represent any skewed turbulence circulations .The distribution is inferred from the first-, second-, and third-order moments of the variables given above, and is used to diagnose cloud fraction and grid-mean liquid water mixing ratio, as well as the buoyancy and fourth-order terms in the equations describing the evolution of the second- and third-order moments. Only three third-order moments (those of θ l , q t , and w ) are predicted in the IPHOC.

99 GENERAL AND MISCELLANEOUS↗

Innovation Incubator: LiquidCool Solutions Technical Evaluation. Laboratory Study and Demonstration Results of a Directed-Flow, Liquid Submerged Server for High-Efficiency Data Centers

LiquidCool Solutions (LCS) has developed liquid submerged server (LSS) technology that changes the way computer electronics are cooled. The technology provides an option to cool electronics by the direct contact flow of dielectric fluid (coolant) into a sealed enclosure housing all the electronics of a single server. The intimate dielectric fluid contact with electronics improves the effectiveness of heat removal from the electronics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ghent Generating Station Nuclear Study: Siting Evaluation

The purpose of this initial siting evaluation is to assess the suitability of the PPL Corporation (PPL) owned land at/near the Kentucky Utilities Ghent Generating Station (GGS) for the deployment of advanced nuclear reactors and to determine if there are any exclusionary or avoidance factors associated with siting nuclear power at GGS. The formal siting process for a nuclear reactor requires a great level of time (i.e., multiple years), effort, and detail. The Electric Power Research Institute (EPRI) estimates the formal siting process could take a dedicated team between one and three years to complete. This initial siting evaluation considers several characteristics (e.g., environmental conditions, seismic concerns, footprint, water use, etc.) and highlights favorable/preferred characteristics as well as potential risks to feasibility. Potential risks were explored in greater detail to provide PPL with additional insights to support decision planning. The results indicate the strengths and weaknesses associated with the GGS site as a location for a nuclear generating station and are intended to inform PPL’s next steps. The results of this initial siting evaluation will also inform the selection of candidate nuclear technologies for the GGS site that align with PPL’s mission and business objectives.

99 GENERAL AND MISCELLANEOUS↗

Impact of Heaters on Molten Salt Reactors Dynamics

Recently, there has been renewed interest in the Molten Salt Reactor (MSR) concept. This interest is mainly due to its advantages over Light Water Reactors (LWRs). Among these advantages are the flexibility in the fuel choice and the possibility to burn actinides [1]. Currently, two molten research reactors are under development. A 2 MW molten salt experimental reactor has been constructed and is planned for operation in China. A 1 MW Molten Salt Research Reactor is under construction in the United States [2]. Thus, Research and Development (R&D) programs are needed for the MSR technology. Reactor dynamics studies are crucial safety evaluation studies. The development of reactor dynamics tools for MSRs started during the Molten Salt Reactor Program (MSRP) at ORNL, focusing on the Molten Salt Reactor Experiment (MSRE) [3]. Although various dynamic simulation tools are available, R&D efforts to develop specialized tools for MSRs are still ongoing [4]. The primary motivation for this interest is the goal of commercializing MSRs. Developing a dynamics tool for MSRs is crucial for analyzing their safety and supporting their demonstration efforts. A crucial safety issue in MSRs is ensuring that the fuel salt in the primary loop remains molten. This concern becomes particularly important when the reactor operates at lower power levels. Most chloride and fluoride salts used as fuel have a melting point of approximately 450 °C [5]. Therefore, maintaining fuel salt temperatures above this melting point is essential to prevent it from freezing. Freezing of the fuel salt can lead to volume expansion, potentially causing damage to reactor components [6]. Moreover, it can create local blockages within fuel salt channels, reducing cooling efficiency and resulting in hot spots [7]. Various methods can prevent fuel salt from freezing at low power levels. These include reducing the fuel mass flow rate in the primary loop, decreasing heat exchange between the primary and secondary loops in the reactor, and using electric fuel salt heaters. Reducing the mass flow rate of fuel salt in the primary loop can increase the fuel salt transit time in the core, enhancing heat production and increasing temperature. However, it can potentially lead to challenges. These include increasing the potential for fuel salt deposition on the reactor channel walls [8], affecting the overall heat transfer processes. Thus, alternative methods should be used [9]. This research investigates the effects of fuel salt heaters on the dynamics and stability during MSR operation. The investigation includes studying the reactor stability with the fuel salt heaters on and off. In addition, the reactor response to transients is compared with and without the operation of fuel salt heaters. These transients include reactivity insertion, primary and secondary pump failure, and heat sink temperature increase. The results of the reactivity insertion transient are presented in the summary.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance evaluation of interpolation methods for incorporating rain gauge measurements into NEXRAD precipitation data: A case study in the Upper Guadalupe River Basin

High spatial and temporal resolution of precipitation data is critical input for hydrological budget estimation and flash flood modeling. This study evaluated four methods (Bias Adjustment (BA), Simple Kriging with varying Local Means (SKlm), Kriging with External Drift (KED), and Regression Kriging (RK)) for their performances in incorporating gauge rainfall measurements into NEXRAD (Next Generation Weather Radar) Multisensor Precipitation Estimator (MPE) (hourly and 4 x 4 km{sup 2}). Measurements from a network of 50 gauges at the Upper Guadalupe River Basin, Central Texas and MPE data for the year 2004 were used in the study. We used three evaluation coefficients Percentage Bias (PB), Coefficient of Determination (R2), and Nash-Sutcliffe efficiency (NSE) to examine the performance of the four methods for preserving regional and local scale characteristics of observed precipitation data. The results show that the two Kriging-based methods (SKlm and RK) are in generally better than BA and KED and that the PB and NSE criteria are better than the R2 criterion in assessing the performance of the four methods. It is also worth noting that the performance of one method at regional scale may be different from its performance at local scale. Critical evaluation of the performance of different methods at local or regional scale should be conducted according to the different purposes. The results obtained in this study are expected to contribute to the development of more accurate spatial rainfall products for hydrologic budget and flash flood modeling.

54 ENVIRONMENTAL SCIENCES↗

Gastrostomy Tube Placement Without Nasogastric Tube: A Retrospective Evaluation in 85 Patients

Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncture of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗