Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Deployment and performance of a Low-Energy-Threshold Skipper-CCD inside a nuclear reactor

Charge Coupled Devices (CCD) are being used for reactor neutrino experiments and have already demonstrated their potential in constraining new physics models. The prospect of a Skipper-CCD experiment looking for standard and beyond standard model (BSM) physics in a nuclear reactor has been evaluated for different benchmark scenarios. Here, we report the first installation of a 2-g Skipper-CCD inside the containment building of a 2 GW th nuclear power plant and analyze its performance throughout its first 18 months of operation. The sensor was successfully deployed at Atucha II, in Argentina, 12 meters away from the center of the reactor core. We discuss the challenges involved in the commissioning of the detector and present data acquired during reactor ON and reactor OFF periods, with the sensor functioning with a sub-electron readout noise of 0.17 e - . Based on an exposure of 56.8 g day reactor ON and two reactor OFF data sets with a total exposure of 118.1 g day we characterize the system and evaluate the sensitivity to CEvNS. We achieved a background rate of 33 kdru and a low threshold of 45 eV ee . The ongoing efforts to improve sensitivities to CEvNS and BSM interaction are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗

Methods to determine the radiated power in SPI-mitigated disruptions in JET

Here we present techniques for evaluating the radiated power in JET disruptions. Disrupting plasmas are shown to have non-axisymmetric radiation profiles, motivating the re-evaluation of the standard techniques for calculating the total radiated power at JET using bolometry. Four single-channel bolometers at different toroidal locations are exploited to quantify the radiation asymmetry. Toroidal radiation peaking factors integrated over the entire disruption of up to 1.5 have been observed when varying the quantity of neon in pellets used in disruptions mitigated by shattered pellet injection. Using synthetic bolometer diagnostics developed with the Cherab spectroscopy modeling framework, we can estimate the systematic error on total power calculations for relevant radiation profiles and improve estimates of the total radiated power. We show that the component of the systematic error on the total power due to the poloidal radiation profile can be reduced from 70% to 10% with suitable assumptions about the structure of the poloidal profile.

47 OTHER INSTRUMENTATION↗

Re-evaluation of ortho-para- dependence of self pressure-broadening in the ν 1 + ν 3 band of acetylene

Optical frequency comb-referenced measurements of self pressure-broadened line profiles of the R(8) to R(13) lines in the ν 1 + ν 3 combination band of acetylene near 1.52 µ m are reported. The analysis of the data found no evidence for a previously reported systematic alternation in self pressure-broadened line widths with the nuclear spin state of the molecule. This work brought out the need for the use of an accurate line profile model and careful accounting for weak background absorptions due to hot band and lower abundance isotopomer lines. The data were adequately fit using the quadratic speed-dependent Voigt profile model, neglecting the small speed-dependent shift. Parameters describing the most probable and speed-dependent pressure-broadening, most probable shift, and the line strength were determined for each line. Detailed modeling of the results of Iwakuni et al. showed that their neglect of collisional narrowing due to the speed-dependent broadening term combined with the strongly absorbing data recorded and analyzed in transmission mode were the reasons for their results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

3D printing↗

Radio frequency mixing modules for superconducting qubit room temperature control systems

As the number of qubits in nascent quantum processing units increases, the connectorized RF (radio frequency) analog circuits used in first generation experiments become exceedingly complex. The physical size, cost, and electrical failure rate all become limiting factors in the extensibility of control systems. We have developed a series of compact RF mixing boards to address this challenge by integrating I/Q quadrature mixing, intermediate frequency/LO (local oscillator)/RF power level adjustments, and direct current bias fine tuning on a 40 × 80 mm 2 four-layer printed circuit board with electromagnetic interference shielding. The RF mixing module is designed to work with RF and LO frequencies between 2.5 and 8.5 GHz. The typical image rejection and adjacent channel isolation are measured to be ~27 dBc and ~50 dB. By scanning the drive phase in a loopback test, the module short-term amplitude and phase linearity are typically measured to be 5 ×10 -4 (V pp /V mean ) and 1 ×10 -3 radian (pk-pk). The operation of the RF mixing board was validated by integrating it into the room temperature control system of a superconducting quantum processor and executing randomized benchmarking characterization of single and two qubit gates. We measured a single-qubit process infidelity of 9.3(3) × 10 -4 and a two-qubit process infidelity of 2.7(1) × 10 -2 .

47 OTHER INSTRUMENTATION↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Extension of the flux fit method for estimating power deposition profiles

The flux fit method is used to self-consistently estimate the power deposition profile and heat transport profiles from temperature measurements originating from perturbative experiments with a modulated source. Furthermore, this letter improves on this method by addressing the limitations and assumptions. The most crucial improvement is the additional freedom in the source deposition profile. Allowing for a variable central deposition location and height and including a skewness parameter produces deposition profiles more consistent with the measurement data, but still wider than equilibrium ray tracing in two different DIII-D discharges. Moreover, we show that the quality of the estimated deposition profile is key to the accuracy of diffusivity and connectivity estimates, but inversely, the estimated transport parameters hardly affect the quality of the power deposition estimate. Using this method, we show that the power deposition profile estimate is broadened with respect to ray-tracing by about 1.7-1.8 times in two DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of space charge induced non-linearity in the Single Line Of Sight camera

We report a new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such systems, the Single Line Of Sight camera. Results of this characterization are used to benchmark Particle In Cell simulations of the electrons drifting inside the detector, which are found to well reproduce experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insight into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Thomson scattering on the large plasma device

We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint scattering signal from the stray light. In this paper, we describe the diagnostic and its calibration via Raman scattering and present the first measurements performed with the fully commissioned system. Depending on the discharge conditions, the measured densities and temperatures range from 4.0 × 10 12 to 2.8 × 10 13 cm -3 and from 1.2 to 6.8 eV, respectively. The variation of the measurement error with plasma parameters and discharges averaged is also discussed.

47 OTHER INSTRUMENTATION↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device

A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier; measurements with multiple amplifiers can then be combined to further reduce the readout noise. The readout speed of this detector scales roughly linearly with the number of amplifiers without requiring segmentation of the active area. The performance of this detector is demonstrated, emphasizing the ability to resolve individual quanta and the ability to combine measurements across amplifiers to reduce readout noise. The unprecedented low noise and fast readout of the MAS-CCD make it a unique technology for astronomical observations, quantum imaging, and low-energy interacting particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗