Influence of probe contamination on recombination of atomic hydrogen
Atomic hydrogen concentration profiles were measured through a screen-stabilized one-dimensional propane/oxygen front using a specially modified electron spin resonance (ESR) spectrometer. The ESR line occurring at 3075.5 G at 9261.2 MHz was monitored in the presence and absence of various halogenated hydrocarbons. A significant cumulative decrease in peak intensity occurred with addition of any halogenated compound. Further results suggest that the effect is due to inhibitor action on the transport tube walls followed by changes in atomic hydrogen interaction with the walls, and that hydrogen decay is nonlinear in the halogenated tube.