Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Local conditions for the Pauli potential in order to yield self-consistent electron densities exhibiting proper atomic shell structure

The local conditions for the Pauli potential that are necessary in order to yield self-consistent electron densities from orbital-free calculations are investigated for approximations that are expressed with the help of a local position variable. It is shown that those local conditions also apply when the Pauli potential is given in terms of the electron density. An explicit formula for the Ne atom is given, preserving the local conditions during the iterative procedure. The resulting orbital-free electron density exhibits proper shell structure behavior and is in close agreement with the Kohn-Sham electron density. This study demonstrates that it is possible to obtain self-consistent orbital-free electron densities with proper atomic shell structure from simple one-point approximations for the Pauli potential at local density level.

74 ATOMIC AND MOLECULAR PHYSICS↗

Synopsis of D- and E-region electron densities during the energy budget campaign

Electron density profiles from ground-based and rocket-borne measurements conducted at three sites in northern Scandinavia under various degrees of geophysical disturbances are presented. These data are checked against an instantaneous picture of the ionospheric absorption obtained via the dense riometer network. A map of the riometer absorption and measured electron densities over Scandinavia is given.

Friedrich, M.↗

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Curling probe measurement of electron density in pulse-modulated plasma

The electron density n{sub e} of stationary plasma can be easily obtained on the basis of the resonance frequency f of a curling probe (CP) measured by a network analyzer (NWA). However, in pulsed plasma with discharge period T, the n{sub e} and f values periodically change with time. This study extends the conventional CP technique to a time-resolved measurement of the pulse-modulated electron density. The condition necessary for the measurement is revealed to be synchronization of NWA with the pulse modulation, which is expressed as (n − 1)T/T{sub SWP} = integer (1, 2, …) for a number n of data point and sweep time T{sub SWP}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron density measurement of inductively coupled plasmas by terahertz time-domain spectroscopy (THz-TDS)

The electron densities of argon inductively coupled plasmas were measured by terahertz time-domain spectroscopy (THz-TDS). At a low pressure, the electron densities were also measured with a Langmuir-type double probe and the validity of THz-TDS electron-density measurement in a plasma has been corroborated. As the input radio-frequency (RF) power increases, the plasma density and gas temperature increase, which makes the probe measurement less reliable or even impossible, due to the large heat load to the probe surface. On the contrary, the THz-TDS measurement is unaffected by the gas temperature and becomes more reliable due to the higher electron density at higher input power for plasma generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional mapping of electron densities and temperatures using laser-collision induced fluorescence.

We discuss the application of the laser-collision induced fluorescence technique to produce two-dimensional maps of both electron densities and electron temperatures in a helium plasma. A collisional-radiative model is used to describe the evolution of electronic states after laser excitation. We discuss generalizations to the time dependant results that are used to simplify data acquisition and analysis. Calibration of the predictions made by the model is achieved using an cw rf discharge that is periodically perturbed via a high voltage pulse. We then demonstrate the capability of the technique by producing images of electron density and temperature of the sheath region formed around a biased electrode.

99 GENERAL AND MISCELLANEOUS↗

Electron Density Profiles of the Topside Ionosphere

The existing uncertainties about the electron density profiles in the topside ionosphere, i.e., in the height region from h,F2 to - 2000 km, require the search for new data sources. The ISIS and Alouette topside sounder satellites from the sixties to the eighties recorded millions of ionograms but most were not analyzed in terms of electron density profiles. In recent years an effort started to digitize the analog recordings to prepare the ionograms for computerized analysis. As of November 2001 about 350000 ionograms have been digitized from the original 7-track analog tapes. These data are available in binary and CDF format from the anonymous ftp site of the National Space Science Data Center. A search site and browse capabilities on CDAWeb assist the scientific usage of these data. All information and access links can be found at http://nssdc.gsfc.nasa.gov/space/isis/isis- status.htm1. This paper describes the ISIS data restoration effort and shows how the digital ionograms are automatically processed into electron density profiles from satellite orbit altitude (1400 km for ISIS-2) down to the F peak. Because of the large volume of data an automated processing algorithm is imperative. The TOPside Ionogram Scaler with True height algorithm TOPIST software developed for this task is successfully scaling - 70% of the ionograms. An < > is available to manually scale the more difficult ionograms. The automated processing of the digitized ISIS ionograms is now underway, producing a much-needed database of topside electron density profiles for ionospheric modeling covering more than one solar cycle.

Huang, Xue-Qin↗

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗

Interpretation of very low resolution X-ray electron-density maps using core objects

The interpretation of a 20 Å resolution electron-density map using segmentation and pattern-recognition-based identification of domain shapes is described. A novel approach to obtaining structural information from macromolecular X-ray data extending to resolutions as low as 20 Å is presented. Following a simple map-segmentation procedure, the approximate shapes of the domains forming the structure are identified. A pattern-recognition comparative analysis of these shapes and those derived from the structures of domains from the PDB results in candidate structural models that can be used for a fit into the density map. It is shown that the placed candidate models can be employed for subsequent phase extension to higher resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale mapping of the electron density at Al grain boundaries and correlation with grain-boundary energy

Grain-boundary (GB) structures and energies are often calculated and have revealed correlations between the GB energy and change in electron density at the GB. In this work, the plasmon peak in valence electron energy-loss spectroscopy (VEELS) was used to determine the variation in electron density across four well-characterized GBs in Al, spanning a range of known GB energies. The results show that the plasmon energy is lower at the GB than in the adjacent grains due to a decrease in electron density, and the GB energy increases proportional to the density decrease. The decrease in electron density also extends further into adjacent grains with increasing GB energy, extending beyond the geometric changes, or physical width, revealed by electron microscopy. Plasmon damping also increases with increasing GB energy, indicative of increasing disruption of the electron density with increasing GB energy. These results demonstrate that VEELS can be a valuable tool for detecting small electron density changes at GBs, and this change clearly influences, and is correlated to, the GB energy.

36 MATERIALS SCIENCE↗

Compact and high-particle-flux thermal-lithium-beam probe system for measurement of two-dimensional electron density profile

A compact and high-particle-flux thermal-lithium-beam source for two-dimensional measurement of electron density profiles has been developed. The thermal-lithium-beam oven is heated by a carbon heater. In this system, the maximum particle flux of the thermal lithium beam was ∼4 × 10{sup 19} m{sup −2} s{sup −1} when the temperature of the thermal-lithium-beam oven was 900 K. The electron density profile was evaluated in the small tokamak device HYBTOK-II. The electron density profile was reconstructed using the thermal-lithium-beam probe data and this profile was consistent with the electron density profile measured with a Langmuir electrostatic probe. We confirm that the developed thermal-lithium-beam probe can be used to measure the two-dimensional electron density profile with high time and spatial resolutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of Electron Density near Plasma Grid of Large-scaled Negative Ion Source by Means of Millimeter-Wave Interferometer

A millimeter-wave interferometer with the frequency of 39 GHz ({lambda} 7.7 mm) was newly installed to a large-scaled negative ion source. The measurable line-integrated electron density (n{sub e}l) is from 2x10{sup 16} to 7x10{sup 18} m{sup -2}, where n{sub e} and l represent an electron density and the plasma length along the millimeter-wave path, respectively. Our interest in this study is behavior of negative ions and reduction of electron density in the beam extraction region near the plasma grid. The first results show the possibility of the electron density measurement by the millimeter-wave interferometer in this region. The line-averaged electron density increases proportional to the arc power under the condition without cesium seeding. The significant decrease of the electron density and significant increase of the negative ion density were observed just after the cesium seeding. The electron density measured with the interferometer agrees well with that observed with a Langmuir probe. The very high negative ion ratio of n{sub H-}/(n{sub e}+n{sub H-}) = 0.85 was achieved within 400 min. after the cesium seeding.

43 PARTICLE ACCELERATORS↗

Electron density measurements of an inhomogeneous plasma using millimeter wave Fabry-Perot interferometers.

The electron density of a laboratory generated inhomogeneous plasma was measured using 60-90, GHz flat-plate and 150 GHz semi-confocal Fabry-Perot interferometers. The plasma was a negative glow-type and had a measured parabolic electron density profile. An analytical comparison between the derived equations of electron density for an assumed homogeneous plasma slab and an inhomogeneous plasma with parabolic distribution showed that the slab approximation was valid for such a profile. Comparison of measured values of electron density with those using X-band and K-band interferometers for the same plasma indicated good agreement.

Kendall, B. M.↗

Electron density and temperature of gas-temperature-dependent cryoplasma jet

A microsize cryoplasma jet was developed and analyzed at plasma gas temperatures ranging from room temperature down to 5 K. Experimental results obtained from optical emission spectroscopy and current-voltage measurements indicate that the average electron density and electron temperature of the cryoplasma jet depend on the gas temperature. In particular, the electron temperature in the cryoplasma starts to decrease rapidly near 60 K from about 13 eV at 60 K to 2 eV at 5 K, while the electron density increases from about 10{sup 9} to approximately 10{sup 12} cm{sup -3} from room temperature to 5 K. This phenomenon induces an increase in the Coulomb interaction between electrons, which can be explained by the virial equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical quality indicators for electron-density maps

A likelihood-based metric for scoring the local agreement of a structure model with the observed electron density is described. The commonly used validation metrics for the local agreement of a structure model with the observed electron density, namely the real-space R (RSR) and the real-space correlation coefficient (RSCC), are reviewed. It is argued that the primary goal of all validation techniques is to verify the accuracy of the model, since precision is an inherent property of the crystal and the data. It is demonstrated that the principal weakness of both of the above metrics is their inability to distinguish the accuracy of the model from its precision. Furthermore, neither of these metrics in their usual implementation indicate the statistical significance of the result. The statistical properties of electron-density maps are reviewed and an improved alternative likelihood-based metric is suggested. This leads naturally to a χ{sup 2} significance test of the difference density using the real-space difference density Z score (RSZD). This is a metric purely of the local model accuracy, as required for effective model validation and structure optimization by practising crystallographers prior to submission of a structure model to the PDB. A new real-space observed density Z score (RSZO) is also proposed; this is a metric purely of the model precision, as a substitute for other precision metrics such as the B factor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗