At least 127 records · Page 7

NiFeCo-based catalysts in high current zero-gap anion exchange membrane water electrolyzers

Understanding degradation mechanisms in pure water anion exchange membrane water electrolyzers is essential for developing durable and precious metal-free hydrogen production systems, yet electronic, chemical, and transport-driven pathways often occur simultaneously at the anode. To separate these effects, we establish a morphology invariant Ni/Fe/Co thin film model catalyst platform using physical vapor deposition and systematically compare composition-dependent behavior under both pure water and 0.1 M KOH feeds. Devices were operated under industrially relevant current density conditions, galvanostatically at 1 A cm −2 for 24 hours; metal dissolution, ionomer oxidation, and resistance growth were quantified using inductively coupled plasma mass spectrometry, X-ray photoelectron spectroscopy (XPS), and electrochemical impedance spectroscopy. Under pure-water operation, Ni-rich films showed voltage increases that correlated with rising total cell resistance (ΔV ≈ 243 mV, ΔR ≈ 0.17 Ω cm 2 ). Co-rich films maintained near constant voltages with minimal resistance change (ΔV < 10 mV, ΔR ≈ 0.03 Ω cm 2 ) but induced pronounced ionomer oxidation observed by XPS. In 0.1 M KOH, ionomer oxidation is suppressed, and impedance growth is minimized (<0.08 Ω cm 2 ) across all compositions, consistent with reduced transport limitations and improved ionic conduction relative to pure-water feeds. These results demonstrate how a controlled thin film model platform can isolate composition electrolyte relationships and provide mechanistic design principles for stable pure water anion exchange membrane electrolyzers.

Milenia Rojas Mendoza, B. [Stanford Univ., CA (Uni↗

Assessment of lignite upgrade and hydrogen evolution via electrolysis

Lignite, considered as the lowest-rank coal, accounts for 45% of the total coal resources worldwide, and its low carbon and high ash contents limit its large-scale application. In order to upgrade lignite effectively, a modified coal electrolytic cell (MCEC) was designed, built, and then evaluated for lignite upgrade and hydrogen production through electrolysis, and the operating conditions were optimized. The results show that the performance of the MCEC outperformed the previous coal electrolytic cell (CEC). The operating temperature and iron concentration significantly impact the average current density per milligram of catalyst (ACDMC). The content of dry fixed carbon and heating value increased by 20.9% (wt%) and 8.15%, respectively, in electrolyzed lignite compared with raw lignite. Besides, 71.5% ash and 39.6% mercury were removed from raw lignite after electrolysis, which is the first report. The Faradaic efficiency (FE) for hydrogen evolution reached 99% using MCEC. In addition, the analysis of spectroscopy methods (SEM, EDX, FTIR, and XRD) revealed that the lignite particles were cracked; the oxygen-containing functional groups increased; the minerals of quartz and hematite formed on the surface of lignite particles after electrolysis. Furthermore, the facts indicate that electrolysis of lignite is a competitive approach for lignite upgrade and hydrogen production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

Carbon dioxide and water vapor high temperature electrolysis

The design, fabrication, breadboard testing, and the data base obtained for solid oxide electrolysis systems that have applications for planetary manned missions and habitats are reviewed. The breadboard tested contains sixteen tubular cells in a closely packed bundle for the electrolysis of carbon dioxide and water vapor. The discussion covers energy requirements, volume, weight, and operational characteristics related to the measurement of the reactant and product gas compositions, temperature distribution along the electrolyzer tubular cells and through the bundle, and thermal energy losses. The reliability of individual cell performance in the bundle configuration is assessed.

Isenberg, Arnold O.↗

Establishment of a Vertically Integrated Domestic Manufacturing Process for Production of Substrates Needed for Manufacture of Gas Diffusion Layers

In this project, AvCarb, LLC evaluated the baseline performance metrics of commercial carbon veils and their corresponding Gas Diffusion Layers (GDLs) with the goal of establishing an optimized, vertically integrated production system for wet-laid nonwoven substrates used in gas diffusion media for electrochemical energy storage and conversion devices. Mechanical testing and microstructural characterization were conducted and used to develop a multiscale computational model capable of simulating and predicting the performance of GDLs in fuel cells. Although the project successfully generated foundational transport and modeling data, it was terminated prior to identifying the critical GDL design parameters necessary for full optimization. The program aimed to improve carbon veil fabrication through enhanced fiber dispersion, fiber-fiber adhesion control, and improved web formation, enabling the production of high-quality, uniform substrates. Simulations were intended to guide mixing and solution delivery system design and process conditions, followed by production-scale trials to evaluate fiber dispersion, web uniformity, and mechanical robustness. At full deployment, the proposed production line would have been capable of producing approximately 650,000 m² of carbon veil annually. This capability remains strategically important, as the United States currently lacks a domestic source of wet-laid nonwoven carbon substrates that satisfy the stringent quality requirements for fuel-cell GDLs and electrolyzers representing an ongoing supply-chain vulnerability. Beyond supply-chain benefits, the project established a robust benchmarking dataset for existing commercial carbon veils while advancing next-generation material concepts targeting improved performance and manufacturing consistency.

Olson, Cynthia Lemay↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Oxygen Generation Assembly Design for Exploration Missions

Future Exploration missions will require an Oxygen Generation Assembly (OGA) to electrolyze water to supply oxygen for crew metabolic consumption. The system design will be based on the International Space Station (ISS) OGA but with added improvements based on lessons learned during ISS operations. These improvements will reduce system weight, crew maintenance time and resupply mass from Earth while increasing reliability. Currently, the design team is investigating the feasibility of the upgrades by performing ground tests and analyses. Upgrades being considered include: redesign of the electrolysis cell stack, deletion of the hydrogen dome, replacement of the hydrogen sensors, deletion of the wastewater interface, redesign of the recirculation loop deionizing bed and redesign of the cell stack Power Supply Module. The upgrades will be first demonstrated on the ISS OGA.

Takada, Kevin↗

Elucidating the Role of Hydroxide Electrolyte on Anion-Exchange-Membrane Water Electrolyzer Performance

Many solid-state devices, especially those requiring anion conduction, often add a supporting electrolyte to enable efficient operation. The prototypical case is that of anion-exchange-membrane water electrolyzers (AEMWEs), where addition of an alkali metal solution improves performance. However, the specific mechanism of this performance improvement is currently unknown. This work investigates the functionality of the alkali metal solution in AEMWEs using experiments and mathematical models. The results show that additional hydroxide plays a key role not only in ohmic resistance of the membrane and catalyst layer but also in the reaction kinetics. The modeling suggests that the added liquid electrolyte creates an additional electrochemical interface with the electrocatalyst that provides ion-transport pathways and distributes product gas bubbles; the total effective electrochemical active surface area in the cell with 1 M KOH is 5 times higher than that of the cell with DI water. In the cell with 1 M KOH, more than 80% of the reaction current is associate with the liquid electrolyte. These results indicate the importance of high pH of electrolyte and catalyst/electrolyte interface in AEMWEs. The understanding of the functionality of the alkali metal solution presented in this study should help guide the design and optimization of AEMWEs.

25 ENERGY STORAGE↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Validation of an Advanced High-Pressure PEM Electrolyzer and Composite Hydrogen Storage

One of the challenges associated with transitioning our nation’s transportation economy to any alternative fuel is bringing fuel production, storage, transportation, and end-customer delivery infrastructure online. There are challenges associated with planning and implementing hydrogen fueling stations at locations relevant to the parallel effort of bringing the related transportation vehicles into the market. There are additional challenges associated with the operation of hydrogen fueling stations and reducing operating costs through energy reduction. Through calculation and design efforts it was concluded that elevating the pressure of a PEM cell stack and further developing hydrogen processing equipment that support elevated pressures while maintaining similar characteristics to their current production counterparts will yield in energy savings and by extension cost reductions. In this report, the design of a 57-bar (827-psig) electrolysis system and electrolysis cell stack is described. Furthermore, the fabrication, component verification, and integrated testing are summarized. Prior to this development effort, Proton had demonstrated thousand of hours of durability on 30-bar (435-psig) differential pressure PEM electrolysis hardware. Proton has sold and installed many of these 30-bar devices at customer sites. Through this project, Proton has developed and tested 57-bar PEM electrolysis, thereby extending the proven capability of PEM electrolysis as a hydrogen generation and electrochemical compression device. A design and validation effort to arrange hydrogen processioning equipment for refueling OEM vehicles was also undertaken within this project. By arranging equipment within two 6-meter ISO shipping containers and further developing NFPA 2 Hydrogen Technologies Code to support containerized hydrogen equipment, efforts to site, install, and commission, and approve hydrogen fueling stations were reduced and now provide a groundwork for future installations.

08 HYDROGEN↗

Advanced Oxygen Generation Assembly for Exploration Missions

Future Exploration missions will require an Oxygen Generation Assembly (OGA) to electrolyze water to supply oxygen for crew metabolic consumption. The system design will be based on the International Space Station (ISS) OGA but with added improvements based on lessons learned during ISS operations and technological advances since the original OGA was designed and built. These improvements will reduce system weight, crew maintenance time and spares mass while increasing reliability. Currently, the design team is investigating the feasibility of the upgrades by performing ground tests and analyses. Upgrades being considered include: redesign of the electrolysis cell stack, deletion of the hydrogen dome, replacement of the hydrogen sensors, deletion of the wastewater interface, redesign of the recirculation loop deionizing bed and redesign of the cell stack Power Supply Module. The upgrades will be first demonstrated on the ISS OGA.

Takada, Kevin↗

Status of the Advanced Oxygen Generation Assembly Design

Future Exploration missions will require an Oxygen Generation Assembly (OGA) to electrolyze water to supply oxygen for crew metabolic consumption. The system design will be based on the international Space Station (ISS) OGA but with added improvements based on lessons learned during ISS operations and technological advances since the original OGA was designed and built. The goal of these improvements will be to reduce system mass, crew maintenance time and spares mass while increasing reliability. The design team has performed trade studies, tests and analyses to inform the redesign. Upgrades being considered include: redesign of the electrolysis cell stack, redesign of the hydrogen dome, replacement of the hydrogen sensors, redesign of the recirculation loop deionizing bed and redesign of the cell stack Power Supply Module. The ISS OGA will be upgraded to an Advanced OGA (AOGA) configuration and its operation demonstrated in a flight environment.

ECLSS↗

Benchtop Autonomous Electrochemical Characterization System for Combinatorial Thin-Film Solid Oxide Electrodes

The design of materials for electrochemical energy conversion is complicated by a vast search space of candidate materials and multifaceted property requirements: multicarrier conductivity, stability, and catalytic activity are all necessary but rarely intersect. Although self-driving laboratories are rapidly rising to address such material optimization problems, the required infrastructure for integrated, large-scale robotic facilities can be cost-prohibitive. Here we develop and evaluate a closed-loop measurement system for efficient screening of proton-conducting oxide electrodes for ceramic fuel cells and electrolyzers, building on top of an existing benchtop instrument and integrating techniques for rapid impedance measurement and automated analysis. This system exemplifies a “minimum viable” self-driving implementation that can deliver substantial benefits with relatively simple infrastructure. Combinatorial thin-film microelectrode libraries are characterized with a recently developed joint time-domain and frequency-domain impedance measurement technique, which provides an order-of-magnitude acceleration relative to conventional impedance spectroscopy. The distribution of relaxation times is extracted from impedance data and analyzed without human intervention. These results feed an active learning and Bayesian optimization process that learns to predict electrochemical impedance as a function of material composition, measurement temperature, oxygen partial pressure, and electrical bias, which further reduces the screening time by tenfold with optimized experimental sequences. We apply this system to Ba⁡(Co,Fe,Zr,Y)⁢O 3−𝛿 combinatorial libraries and evaluate its effectiveness for learning material property trends and optimizing expensive-to-evaluate properties such as activation energy. This offers insights into key methodological aspects of practical autonomous experimentation, including surrogate model validation, cost-aware acquisition functions, and high-throughput data interpretation. Our results demonstrate the efficacy of the system for rapidly gathering information, but also highlight real-world experimental challenges of thin-film degradation and numerical instability in surrogate models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method—Using Microelectrodes to Explore Solid Polymer Electrolytes

Solid polymer electrolytes are an emerging technology in electrochemistry driven by their use in energy applications such as fuel cells, electrolyzers, and solid-state batteries. Compared to traditional liquid electrolytes, solid polymer electrolytes provide safer, cheaper, and potentially improved device performance. However, there is a lack of standard experimental methods for studying solid electrolytes. Microelectrodes have inherent benefits capable of filling this experimental gap due primarily to their integration into model electrochemical cells with solid electrolytes that represent complex interfaces, enabling additional insight into reaction processes. In this tutorial review, we explore the use of microelectrodes to study solid polymer electrolytes, beginning with a brief history of the field including common experimental cell designs and their benefits and drawbacks. Methods of evaluating essential kinetic and mass-transport parameters are then examined. In addition, the key studies of the past 30 years utilizing microelectrode cells and solid polymer electrolytes are summarized, with important results highlighted and compared. Finally, future studies of solid polymer electrolytes with microelectrodes and potential new avenues of research are commented on.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane‐electrode assembly design parameters for optimal CO 2 reduction

Commercial-scale generation of carbon-containing chemicals and fuels by means of electrochemical CO 2 reduction (CO 2 R) requires electrolyzers operating at high current densities and product selectivities. Membrane-electrode assemblies (MEAs) have been shown to be suitable for this purpose. In such devices, the cathode catalyst layer controls both the rate of CO 2 R and the distribution of products. In this study, we investigate how the ionomer-to-catalyst ratio (I:Cat), catalyst loading, and catalyst-layer thickness influence the performance of a cathode catalyst layer containing Ag nanoparticles supported on carbon. In this paper, we explore how these parameters affect the cell performance and establish the role of the exchange solution (water vs. CsHCO 3 ) behind the anode catalyst layer in cell performance. We show that a high total current density is best achieved using an I:Cat ratio of 3 at a Ag loading of 0.01–0.1 mg Ag /cm 2 and with a 1.0 M solution of CsHCO 3 circulated behind the anode catalyst layer. For these conditions, the optimal CO partial current density depends on the voltage applied to the MEA. The work also reveals that the performance of the cathode catalyst layer is limited by a combination of the electrochemically active surface area and the degree to which mass transfer of CO 2 to the surface of the Ag nanoparticles and the transport of OH – anions away from it limit the overall catalyst activity. Hydration of the ionomer in the cathode catalyst layer is found not to be an issue when using an exchange solution. The insights gained allowed for a Ag CO 2 R MEA that operates between 200 mA/cm 2 and 1 A/cm 2 with CO faradaic efficiencies of 78–91%, and the findings and understanding gained herein should be applicable to a broad range of CO 2 R MEA-based devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of catholyte and catalyst layer binders on CO 2 electroreduction selectivity

Electrochemical reduction of carbon dioxide (CO 2 ) is an attractive technology for converting CO 2 to value-added chemicals by using renewably generated electricity. This work combines both experimental and theoretical analyses to investigate the role of different catalysts (Ag/Vu and SnO 2 /Vu), binder materials, and catholyte compositions on the selectivity of a CO 2 electrolysis cell to the two-electron CO 2 reduction products CO and formate. As a complementary effort, a 2D multi-physics transport model was developed to elucidate the fundamental processes and species concentrations in the cathode components. It was shown that the selectivity of CO 2 reduction to CO can change significantly when different catholyte compositions and binder materials are used, whereas the selectivity of CO 2 to formate is relatively stable across the conditions studied. These insights can be used to inform decisions regarding the electrode development and system design in CO 2 electrolyzers and ultimately contribute to scaling energy-efficient electrochemical CO 2 -reduction systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗