Impedance Measurements of Motor Drives and Supplies in NASA NEAT Facility

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. This paper discusses impedance measurements made on the NASA Electric Aircraft Testbed (NEAT) Electrical Power System (EPS) at NASA Glenn Research Center. First, an overall discussion of the NEAT facility configuration during testing is presented. Then, details of the impedance measurement approach and the various testing configurations are discussed. Next, input impedance measurements at NEAT, including sources (DC supplies) and loads (multiple motor drives, electric machines, and resistive load banks, with long interconnecting cable leads), are performed under a number of conditions, and results, including load model comparisons and stability analysis, are presented and discussed.

electrified aircraft propulsion↗

Improving the Accuracy of Clustering Electric Utility Net Load Data using Dynamic Time Warping

Identifying patterns in electric utility net load data in a time-series format is very useful in preparing the operation for next day. Machine learning algorithms have been used in other domains and those concepts are applied in this paper on real-world net load measurement data. Clustering is the practice of grouping data with similar characteristics as determined by the distance measure. The K-means clustering algorithm is utilized here with actual electric utility data. The paper uses the standard distance measure, Euclidean distance (ED), and compares its performance against the dynamic time warping (DTW) measure. An actual case study with real data is presented, and DTW distance measure-based method observed to result better accuracy compared to the ED based method for substation net load measurements predominantly with residential customers.

clustering↗

Practical aspects of photovoltaic technology, applications and cost (revised)

The purpose of this text is to provide the reader with the background, understanding, and computational tools needed to master the practical aspects of photovoltaic (PV) technology, application, and cost. The focus is on stand-alone, silicon solar cell, flat-plate systems in the range of 1 to 25 kWh/day output. Technology topics covered include operation and performance of each of the major system components (e.g., modules, array, battery, regulators, controls, and instrumentation), safety, installation, operation and maintenance, and electrical loads. Application experience and trends are presented. Indices of electrical service performance - reliability, availability, and voltage control - are discussed, and the known service performance of central station electric grid, diesel-generator, and PV stand-alone systems are compared. PV system sizing methods are reviewed and compared, and a procedure for rapid sizing is described and illustrated by the use of several sample cases. The rapid sizing procedure yields an array and battery size that corresponds to a minimum cost system for a given load requirement, insulation condition, and desired level of service performance. PV system capital cost and levelized energy cost are derived as functions of service performance and insulation. Estimates of future trends in PV system costs are made.

Rosenblum, L.↗

A multi-level load shape clustering and disaggregation approach to characterize patterns of energy consumption behavior

This study presents representative electrical load shapes, disaggregated to the end-use level, for over 5000 customer clusters across California’s residential, commercial, industrial and agricultural sectors. We developed a novel, multi-level load shape clustering approach for residential and commercial sectors leveraging interval meter data for over 350,000 California utility customers collected as a part of the Phase 4 California Demand Response (DR) Potential Study. The clustering approach allowed us to identify typical consumption patterns and categorize customers based on their daily load shape displayed throughout the year. For example, we were able to identify customers with particular energy technologies such as electric vehicles and rooftop solar, as well as building occupancy types such as restaurants, grocery stores and even unoccupied buildings, based solely on whole-building interval data. We then combined the load shape-based clusters with other customer information including building type, climate, geographical area, total consumption and low-income status, to create a set of customer clusters based on both demographics and usage patterns. Total cluster electricity demand was then disaggregated into a wide variety of end-uses using weather normalization and other publicly available end-use load shape datasets. The resulting disaggregated cluster load shapes will be released in anonymized form as part of the Phase 4 DR Potential Study. They will have wide-ranging applications in energy research and policy analysis, including estimation of energy efficiency (EE) and DR potential on the end-use level, time-dependent valuation of EE savings, building stock modeling, and developing customer targeting strategies for EE and DR programs.

Murthy, Samanvitha↗

MHD channel performance for potential early commercial MHD power plants

The commercial viability of full and part load early commercial MHD power plants is examined. The load conditions comprise a mass flow of 472 kg/sec in the channel, Rosebud coal, 34% by volume oxygen in the oxidizer preheated to 922 K, and a one percent by mass seeding with K. The full load condition is discussed in terms of a combined cycle plant with optimized electrical output by the MHD channel. Various electrical load parameters, pressure ratios, and magnetic field profiles are considered for a baseload MHD generator, with a finding that a decelerating flow rate yields slightly higher electrical output than a constant flow rate. Nominal and part load conditions are explored, with a reduced gas mass flow rate and an enriched oxygen content. An enthalpy extraction of 24.6% and an isentropic efficiency of 74.2% is predicted for nominal operation of a 526 MWe MHD generator, with higher efficiencies for part load operation.

Swallom, D. W.↗

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Regenerative Fuel Cell System (Cooperative Research and Development Final Report, CRADA Number CRD-16-635)

Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.

13 HYDRO ENERGY↗

Predictive model using artificial neural network to design phase change material-based ocean thermal energy harvesting systems for powering uncrewed underwater vehicles

Uncrewed Underwater Vehicles (UUVs) are a major beneficiary of the phase change material (PCM)-based ocean thermal energy harvesting technology for their mission needs. However, this technology relies on different parameters and energy conversion steps that could be critical to the general energy generation efficiency. Sea trials showed that the design performed lower than their laboratory design specifications. This underperformance results from different factors, mainly the UUV’s trajectory, travel time, underwater ocean currents, temperature fluctuations, and biofouling on the heat exchanger due to long term underwater operations. Therefore, there exists a need to continuously monitor the ambient energy harvesting system and predict system performance, for mission planning purposes. Two major parameters influencing the energy harvesting system include the final pressure inside the hydraulic energy storage vessel or accumulator, and the electrical load value. Here, this work focuses on the hydraulic to electric energy conversion system. Therefore, a combination of numerical model and experimental testing is used to develop a predictive model using artificial neural network using MATLAB. After validation with experimental testing, 1000 data samples obtained from the numerical model are used to train the ANN. Compared to the experimental results, the developed ANN model can predict in less than a second the designed benchtop system’s total efficiency with less than 15 percent maximum error range. This predictive model development represents a cost-effective way for optimization and a computational energy efficient mode aboard UUVs for mission planning for deployed UUVs using PCM-based ocean thermal energy harvesting technology.

30 DIRECT ENERGY CONVERSION↗

High Performance Computing Peak Shaving for Microreactor Operation

There are multiple nuclear microreactors currently under development that are designed to provide autonomous power for as many as ten or more years without refueling and are designed to power high performance computing (HPC) datacenters. But the load-follow speeds for a nuclear microreactor will be much slower than grid power and slower than the power variance typical of a HPC system. HPC datacenters experience peak power load variance driven by several factors ranging from the operation of cooling systems to remove heat from the servers to supporting a wide range of user application workflows and architectures each with different power signatures. One mechanism to support the limited load-follow of a microreactor is peak shaving where an energy storage mechanism is used to shed peak load and reduce significant power variance. This work explores peak electrical load shaving using uninterruptible power supply (UPS) systems designed for HPC support in the context of peak shaving when operating using a nuclear microreactor with a load-follow limited to 10% of load per minute. Using a self contained HPC datacenter complete with stand-alone cooling system and provisioned with an x86 cluster, an ARM cluster, and a graphics processing unit (GPU) cluster, peak shaving for microreactor operation using the UPS battery backup is explored while running two classes of typical HPC user applications. HPC architecture suitability for microreactor operation under this type of peak shaving is examined.

97 MATHEMATICS AND COMPUTING↗

Electric fields and conductivity in the nighttime E-region - A new magnetosphere-ionosphere-atmosphere coupling effect

Calculations have been made of the effects of intense poleward-directed electric fields upon the nighttime ionospheric E-region. The results show the Pedersen and Hall conductivities are substantially changed, thereby decreasing the ionospheric electrical load seen by magnetospheric sources. It appears that relatively large electric fields can exist in the absence of accompanying large field-aligned currents, as long as the underlying ionosphere remains in darkness and/or energetic particle precipitation is absent.

Banks, P. M.↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Resource and Load Compatibility Assessment of Wind Energy Offshore of Humboldt County, California

Floating offshore wind is being considered in northern California as indicated by the Bureau of Ocean Energy Management’s issuance of a lease consideration in the Humboldt Call Area. Humboldt County offers access to this enormous resource, but local electric load and transmission are limited. The potential impacts of offshore wind generators at three different scales were studied using a regional grid model of Humboldt County. Offshore wind generation was calculated using modeled wind speed data and 12-MW turbine specifications and integrated with projected load and historical generation. Offshore wind farms deployed in the Humboldt Call Area achieve annual capacity factors between 45% and 54% after losses and maintenance. Power output is variable between and within seasons, with full power output 30% of the time and no output approximately 20% of the time. Electricity from a 48-MW wind farm provides 22% of regional load with limited exports. A 144-MW wind farm serves 38% of local load, exporting 40% of its electricity with the extant 70-MW transmission capacity. A full build-out of 1836 MW would result in 88% curtailment with existing transmission. Across scenarios, offshore wind variability necessitates reliance on existing power plants to meet local demand in periods of low wind.

17 WIND ENERGY↗

A Priority-Based Control Strategy and Performance Bound for Aggregated HVAC-Based Load Shaping

Air conditioning systems have been recognized as a potential, cost-effective resource for shaping electrical load in a power system. This work presents a new priority-based control strategy that explicitly addresses three requirements for using a collection of air conditioning units in this capacity. These are 1) tracking a regulation signal, 2) maintaining the building temperature near its set point, and 3) satisfying a cycling constraint of the air conditioners. After introducing the control strategy, we derive a bound for the regulation signal within which tracking is guaranteed while also satisfying the temperature requirement. These results are illustrated with simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic load simulator

Concepts and techniques for identifying and simulating both the steady state and dynamic characteristics of electrical loads for use during integrated system test and evaluation are discussed. The investigations showed that it is feasible to design and develop interrogation and simulation equipment to perform the desired functions. During the evaluation, actual spacecraft loads were interrogated by stimulating the loads with their normal input voltage and measuring the resultant voltage and current time histories. Elements of the circuits were optimized by an iterative process of selecting element values and comparing the time-domain response of the model with those obtained from the real equipment during interrogation.

Joncas, K. P.↗

Energy Options Analysis Project (Final Report)

This Bear River Band of Rohnerville Rancheria (BRB) Energy Options Analysis Project provides a rigorous and comprehensive near-term renewable energy implementation plan that aligns with the BRB’s long term strategic vision of “zero net annual utility energy consumption.” Final recommendations were arrived at by following four key project phases:A gas and electricity load assessment was conducted for all existing buildings using historic consumption data, and projected loads of new or anticipated buildings using building designs. A renewable energy resource assessment was conducted that estimated the gross generation potential of solar and wind, constrained to areas that could potentially be developed. Other renewable generation technologies were not considered feasible to meet the loads of the BRB. Demand-side efficiency and fuel switching opportunities were identified that can reduce electrical and gas consumption. These opportunities were not integrated into the load assessment in order to provide a conservative implementation plan, but are recommended to be pursued in order to cost-optimize projects during a feasibility assessment. A strategic vision advisory committee was organized and consulted when iterating on the viability of possible projects. These project phases resulted in finalizing the following three solar PV projects for the near term, which also lay the foundation for a future community-scale or multiple-facility microgrid for added resiliency. Additional solar PV on the hillside south of the Tish-Non Community Center. Solar plus battery storage microgrid at the Pump & Play fuel station. Solar PV at the Casino.

14 SOLAR ENERGY↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗