Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

Properties of Low Tc AlMn TES

Low Tc AlMn transition-edge sensors (TESs) have been developed as sensitive thermometers for the Q-Array, which will use superconducting targets to measure the coherent elastic neutrino nucleus scattering spectrum in the RICOCHET experiment. The TESs are made of manganese-doped aluminum with a titanium and gold antioxidation layer. A prototype TES thermometer consists of two TESs in parallel, an input gold pad in metallic contact with the TESs and an output gold pad and gold thermal link meanders, which are each designed to control the flow of heat through the TESs. We have fabricated and measured low TC AlMn TES chips with or without thermal flow control structures. We present TC measurements of the TESs after the initial fabrication and further TC tuning by re-heating and summarize the thermal property studies of the prototype TES thermometer by measuring I-V curves and complex impedance.

Coherent elastic neutrino nucleus scattering, Cryo↗

Two-Level Switches for Advanced Time-Division Multiplexing

Superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM) is a mature and widely implemented technology used to read out transition-edge sensor arrays. As the number of pixels in modern arrays continues to increase, a higher multiplexing factor is required to reduce the number of wires and amplifier channels. Yet, as the multiplexing factor is increased, the number of row-select wires (used to turn on a row of TDM SQUIDs in a two-dimensional configuration) also increases, limiting the reduction in array wires. We introduce a more advanced TDM architecture that enforces multi-level switching between subgroups of pixels. We show that this technique can dramatically reduce the number of required row-select lines. We also present the design, fabrication, and testing of a TDM multiplexer incorporating a two-level switch, which implements a second switch for each group of ten TDM pixels. In this application, a multiplexing factor of 100 can be addressed using ten group-select wiring pairs and ten row-select wiring pairs. We demonstrate multiplexer functionality and present measured operating margins of this new TDM multiplexer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Sensitivity of AlMn TESes and Shielding Considerations for Next-Generation CMB Surveys

In the next decade, new ground-based cosmic microwave background (CMB) experiments such as Simons Observatory, CCAT-prime, and CMB-S4 will increase the number of detectors observing the CMB by an order of magnitude or more, dramatically improving our understanding of cosmology and astrophysics. These projects will deploy receivers with as many as hundreds of thousands of transition edge sensor (TES) bolometers coupled to superconducting quantum interference device (SQUID)-based readout systems. It is well known that superconducting devices such as TESes and SQUIDs are sensitive to magnetic fields. However, the effects of magnetic fields on TESes are not easily predicted due to the complex behavior of the superconducting transition, which motivates direct measurements of the magnetic sensitivity of these devices. We present comparative four-lead measurements of the critical temperature versus applied magnetic field of AlMn TESes varying in geometry, doping, and leg length, including Advanced ACT and POLARBEAR-2/Simons Array bolometers. MoCu ACTPol TESes are also tested and are found to be more sensitive to magnetic fields than the AlMn devices. We present an observation of weak-link-like behavior in AlMn TESes at low critical currents. We also compare measurements of magnetic sensitivity for time division multiplexing SQUIDs and frequency division multiplexing microwave (mMUX) rf-SQUIDs. We discuss the implications of our measurements on the magnetic shielding required for future experiments that aim to map the CMB to near-fundamental limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SPIDER: CMB Polarimetry from the Edge of Space

Spider is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. Spider targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on mapping a large sky area with high fidelity at multiple frequencies. Spider ’s first long-duration balloon (LDB) flight in January 2015 deployed a total of 2400 antenna-coupled transition-edge sensors (TESs) at 90 GHz and 150 GHz. In this work we review the design and in-flight performance of the Spider instrument, with a particular focus on the measured performance of the detectors and instrument in a space-like loading and radiation environment. Finally, Spider ’s second flight in December 2018 will incorporate payload upgrades and new receivers to map the sky at 285 GHz, providing valuable information for cleaning polarized dust emission from CMB maps.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of the HeRALD superfluid helium detector concept

The SPICE/HeRALD collaboration is performing research and development to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid 4 He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and 4 He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical “quantum evaporation” signal from 4 He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype “HeRALD v0.1” detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. Here, a key result of this work is the measurement of the quantum evaporation channel’s gain of 0.15±0.01, which will enable 4 He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5⁢σ, which would be sensitive to dark matter masses down to 220 MeV/c 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Response of Antenna-Coupled TES Arrays: Results from SPIDER and the Laboratory

Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce ‘glitches’ in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. Here, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Links and Microstrip Transmission Lines in SPT-3G Bolometers

In this work, we have measured the properties of membrane-suspended bolometer thermal links and microstrip transmission lines in the transition-edge sensor arrays for the third-generation camera for South Pole Telescope (SPT-3G). A promising technique for controlling the end point of the release etch that defines the thermal link has been developed. We have also evaluated the microstrip loss in our detectors by measuring the optical efficiency of detectors with different lengths of microstrip line. The loss tangent is sufficiently low for the use in multi-chronic pixels for cosmic microwave background instruments like SPT-3G.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.

47 OTHER INSTRUMENTATION↗

Large arrays of dual-polarized multichroic TES detectors for CMB measurements with the SPT-3G receiver

Now, detectors for cosmic microwave background (CMB) experiments are background limited, so a straightforward alternative to improve sensitivity is to increase the number of detectors. Large arrays of multichroic pixels constitute an economical approach to increasing the number of detectors within a given focal plane area. We present the fabrication of large arrays of dual-polarized multichroic transition-edge-sensor (TES) bolometers for the South Pole Telescope third-generation CMB receiver (SPT-3G). The complete SPT-3G receiver will have 2690 pixels, each with six detectors, allowing for individual measurement of three spectral bands (centered at 95 GHz, 150 GHz and 220 GHz) in two orthogonal polarizations. In total, the SPT-3G focal plane will have 16140 detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a niobium microstrip transmission line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES sensors. Detectors are read out using a 64x frequency domain multiplexing (fMux) scheme. The microfabrication of the SPT-3G detector arrays involves a total of 18 processes, including 13 lithography steps. Together with the fabrication process, the effect of processing on the Ti/Au TES's T-c is discussed. In addition, detectors fabricated with Ti/Au TES films with Tc between 400 mK 560 mK are presented and their thermal characteristics are evaluated. Optical characterization of the arrays is presented as well, indicating that the response of the detectors is in good agreement with the design values for all three spectral bands (95 GHz, 150 GHz, and 220 GHz). The measured optical efficiency of the detectors is between 0.3 and 0.8. Our results discussed here are extracted from a batch of research of development wafers used to develop the baseline process for the fabrication of the arrays of detectors to be deployed with the SPT-3G receiver. Results from these research and development wafers have been incorporated into the fabrication process to get the baseline fabrication process presented here. SPT-3G is scheduled to deploy to the South Pole Telescope in late 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

In-flight performance of S PIDER'S 280-GHz receivers

S PIDER is a balloon-borne instrument designed to map the cosmic microwave background at degree-angular scales in the presence of Galactic foregrounds. S PIDER has mapped a large sky area in the Southern Hemisphere using more than 2000 transition-edge sensors (TESs) during two NASA Long Duration Balloon flights above the Antarctic continent. During its first flight in January 2015, S PIDER observed in the 95 GHz and 150 GHz frequency bands, setting constraints on the B-mode signature of primordial gravitational waves. Its second flight in the 2022-23 season added new receivers at 280 GHz, each using an array of TESs coupled to the sky through feedhorns formed from stacks of silicon wafers. Here, these receivers are optimized to produce deep maps of polarized Galactic dust emission over a large sky area, providing a unique data set with lasting value to the field. In this work, we describe the instrument’s performance during S PIDER'S second flight.

280 GHz cosmology↗

Progress on ANL/KICP bolometers for SPTpol.

We present progress on Argonne/KICP TES bolometers fabricated at Argonne National Labs. These detectors will be used to measure the polarization of the Cosmic Microwave Background radiation with SPTpol. The sensors are bolometers consisting of a Mo/Au transition edge sensors (TES) suspended on silicon nitride with a gold bar absorber to couple radiation to the device. We present optical measurements and thermal characterizations of prototype devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Sensor-Assisted Fault Mitigation in Quantum Computation

We propose a method for assisting fault mitigation in quantum computation through the use of sensors, co-located near physical qubits. Specifically, we consider using transition edge sensors co-located on silicon substrates hosting superconducting qubits to monitor for energy injection from ionizing radiation that has been demonstrated to increase decoherence in transmon qubits. We generalize from these two physical device concepts and explore the potential advantages of co-located sensors to assist fault mitigation in quantum computation. In the simplest scheme, co-located sensors beneficially assist rejection of calculations potentially affected by environmental disturbances. Investigating the potential computational advantage further required development of an extension to the standard formulation of quantum error correction. In a specific case the standard three-qubit, bit flip quantum correction code, we show that given a 20% overall error probability per qubit, approximately 90% of repeated calculation attempts are correctable. However, when sensor-detectable errors account for 45% of overall error probability, the use of colocated sensors uniquely associated with independent qubits, boosts the fraction of correct final-state calculations to 96% at the cost of rejecting 7% of repeated calculation attempts.

Orrell, John L.↗

Bolometric Superconducting Optical Nanoscopy (BOSON)

Superconducting transition-edge sensors are renowned for their extraordinary photon sensitivity and energy resolution, finding applications spanning quantum information, astronomy, and nanophotonics. Here, we report the development of bolometric superconducting optical nanoscopy (BOSON), a novel platform that integrates bolometric detection at the superconducting transition edges with near-field optical techniques. BOSON enables the mapping of photoinduced changes in superconductivity with unprecedented spatial resolution and photon sensitivity. By incorporating BOSON with low-dimensional materials, we achieved polariton imaging at nanowatt excitation levels—at least 4 orders of magnitude lower than the power typically required in prior near-field nanoscopy experiments. Our findings highlight the potential for BOSON to advance scanning-probe-based optical platforms to enable the detection of photons, polaritons, and Cooper pair dynamics at the nanoscale. This paves the way for quantum sensing applications using single-polariton detection and can offer deeper insights into quasiparticle dynamics.