Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ducts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Assembly Bowing Reactivity Calculation Methodology Applied to Lead Fast Reactor

Ducted assemblies bow during operation due to power and temperature gradients which can be influenced by operating flow rates. For fast spectrum cores using ducted assemblies, the bowing behavior follows that of the duct and because there are gaps between the ducts, the bowing can result in compaction or expansion of the active core. This local displacement can have a positive or negative impact and knowing the net effect during transients is important for system reactivity control. Keeping the net bowing reactivity worth low is possible with attentive placement of load pads above the active core and selecting load pad gap thicknesses that result in a desired behavior at standard operating conditions. This paper considers a Lead Fast Reactor (LFR) concept fueled by HALEU UO2 developed by Westinghouse Electric Company (WEC) and applies a workflow of Argonne-developed codes to estimate the core bowing reactivity worth. Using orifice flow rates grouped by assembly type, the net reactivity impact due to core assembly bowing for the LFR was found to be small and in line with other liquid metal fast reactors: +29/+32/+35 pcm, or about +$0.049/+$0.055/+$0.059, for BOEC/MOEC/EOEC, respectively.

bowing reactivity↗

Comparative study with two reduced test facilities for air-cooled RCCS scaling law

Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL) conducted steady-state tests at constant heat flux conditions to investigate the scale effect on heat removal behavior of the air-cooled Reactor Cavity Cooling System (RCCS). Two differently scaled-down test facilities were used in this study, KAERI’s ¼ scale with 4.0-m cavity height, and ANL’s ½ scale with 6.8-m cavity height. Two scaling laws were proposed to simulate the radiation across the cavity and the buoyancy-driven duct flow in the riser, respectively. The test matrix for KAERI and ANL test facilities focused on the scaling effect of the heated riser length with constant heat flux at the PMR200 RCCS design. The test results showed that mixed convection in the riser duct is an important factor for accurately extrapolating the thermo-fluid behavior in the prototype from the test results in the scale-down facilities. The system analysis code, GAMMA+, with improved heat transfer models predicted fairly well the air-cooled RCCS test data from two facilities. GAMMA+ analysis results showed that the predicted radiation fractions on the heated plate in the scale-down test conditions were larger than those on the reactor vessel in the prototype. The scaling law for air-cooled RCCS was improved by considering the mixed convection in the riser duct and the same radiation fraction on the heated plate. The mixed convection effect was calculated by the height ratio. The same radiation fraction provided a conservative extrapolation from the scale-down test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fuel cells for single-aisle regional aircraft: System configuration, performance and cost

A hydrogen fuel cell propelled electric aircraft can compete with incumbent turbofan technologies for single-aisle regional aircraft by coupling design of stack, air handling, thermal management, propulsion, and airframe to optimize performance. The stack operates at 95°C to facilitate heat rejection during take-off and below 75°C during cruise to extend lifetime and is oversized to satisfy power requirements at end of life. A multi-stage turbocompressor with a compression ratio >10 is selected to reach high stack power density at 11,300-m cruise altitude. The propulsion system is configured to accommodate air handling within the core duct, an inclined heat exchanger in the outer duct to limit the nacelle size, and variable area nozzles to independently control mass flows through the core and bypass ducts. The airframe is modified for maximum lift coefficient and longer balanced field length for dramatically reduced thrust during take-off, and the fuselage is stretched by 20% to store liquid hydrogen (LH 2 ). Modularization of power systems promotes safety in one engine inoperative scenarios and allows reaching specific power metrics for stack, balance-of-plant and fuel cell system (FCS), necessary for acceptable take-off weight. In conclusion, cost parity requires increase in FCS lifetime, LH 2 cost reduction, and improved FCS specific power.

Catalyst durability↗

Simulations of divertor designs that spatially separate power and particle exhaust using mid-leg divertor particle pumping

Predictive design modeling of a Dissipation-Focused Divertor for future operation in DIII-D reveals that increasing the poloidal distance of the pump duct entrance from the target surface along the low-field side divertor baffle increases neutral compression and modifies the spatial distribution of power dissipation. With a divertor pump located mid-leg between the target and the X-point, SOLPS-ITER boundary plasma simulations without drifts predict the formation of a dense neutral cloud near the target with > 30x higher neutral compression in detachment, a more stable detachment front located further from the target, and ~25% lower outer midplane separatrix density required for detachment onset, compared to a pump located in the scrape-off layer at the target surface. Up to 19 MW of power flowing into the divertors is modeled using the following two numerical implementations for particle pumping: a specified fraction of particles incident on variable wall sections of the plasma grid is removed from the computational domain (so-called albedo pumping), and a pump duct is modeled which includes dynamics of kinetic neutrals in the duct. The simulations show that the detachment front is located between the divertor target and the X-point and is relatively stable near the pump entrance, without a strong dependence on gas puff rate or injected power. The mid-leg pump design spatially separates the two primary functions of a divertor (power handling and particle exhaust), with the majority of power dissipation occurring near the target plate and particle exhaust taking place further upstream. The benefit of enhanced dissipation using mid-leg pumping comes at the cost of a higher outer midplane separatrix density for a given amount of particle injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

High contribution of canopy to oleoresin accumulation in loblolly pine trees

The shoot system of all loblolly pine (Pinus taeda L.) contains abundant resin ducts, and the oleoresins contained within them have demonstrated roles in constitutive defenses. This study is providing a quantitative assessment of oleoresin biosynthesis and accumulation in resin ducts. Morphometric analyses of representative tissue sections indicate that the fractional volume of resin ducts is particularly high in the cortex of young stems and their needles, representing a major portion of total pine resins from primary growth of the canopy. We demonstrate that it is possible to extrapolate oleoresin formation from the microscopic scale (tissues sections) to the macroscale (entire trees), which has implications for assessing resins as renewable feedstocks for bioproducts.

Srividya, Narayanan↗

Development of a Annual Air Handling Unit Fault Dataset for FDD Tools: Lessons Learned and Considerations for FDD Developers

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault data for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling units and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for a single duct air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, a detailed AHU model was employed to carry out annual simulations of numerous common sensor and mechanical faults, which were then validated by comparing their effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Mixing-Controlled CI Combustion and Fuel-Effects Research

This project is focused on developing advanced combustion strategies for mixing-controlled compressionignition (i.e., diesel-cycle) engines that are synergistic with renewable and/or unconventional fuels in a manner that enhances domestic energy security, economic competitiveness, and environmental quality. During this reporting period, the focus was on ducted fuel injection (DFI), a technology that differs from conventional diesel combustion (CDC) in that it involves injecting fuel along the axis of one or more small cylindrical ducts within the combustion chamber. Each duct performs a function similar to the tube on a Bunsen burner, helping to premix the fuel with the charge-gas before ignition, creating a stable flame that forms little to no soot. The purpose of the work conducted during Fiscal Year (FY) 2019 was to begin determining the extent to which the use of oxygenated fuels, when combined with DFI and charge-gas dilution, can simultaneously lower the soot and nitrogen-oxides (N0 x ) emissions from mixing-controlled compression-ignition engines, and what the corresponding impacts on other regulated emissions and efficiency are likely to be.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of MOOSE-Based Tools for Calculating Radial Core Expansion

Radial core expansion in liquid-metal cooled fast reactor systems is a well-known phenomenon that produces strong reactivity feedback effects. An inherently safe reactor design takes advantage of negative reactivity feedback in accident scenarios by utilizing a core restraint system which produces a bowed shape that allows for radial expansion of the fuel regions. Detailed modeling and simulation of core radial expansion itself as well as subsequent reactivity feedback is a challenging task involving contact of many fuel assembly elements and physics feedback from neutronics, thermal hydraulics, and thermal mechanical response. A variety of physics codes have been developed to model aspects of radial core expansion but in general invoke geometrical or physics approximations. No code system currently exists which tightly and robustly couples these physics with enough detail to fully resolve the complex core radial expansion reactivity feedback effects. The future availability of such a code system is of vital importance to fully understanding the reactivity feedback effects that occur due to radial expansion, and consequently to optimizing the design of the core restraint system. A high-fidelity code will also be used to benchmark existing lower fidelity, faster running models to understand their benefits, limitations, and range of applications. A code development path using MOOSE-based tools is proposed in order to leverage the detailed geometry capabilities and natural tight coupling and robustness of MOOSE-based applications for modeling this complex phenomena. While simulation of the full phenomenon involves several physics, an assessment has been initiated on the capabilities and readiness of the currently available Tensor Mechanics module within MOOSE for calculation of the structural mechanical responses which occur within the reactor core. This report focuses on modeling the force-deformation response which mimics the physics of a duct contact deformation, as well as differential thermal expansion which produces a thermal bowed shaped for the fuel assemblies in a core. Simple examples were initially performed such as simple supported beam bending under load. The complexity of examples was progressively increased to better mimic the duct behavior by including a differential thermal example and inclusion of hexagonal cross-sections in the geometry. Further assessment of the structural mechanical response simulation capability is still required for modeling duct contact interactions and irradiation creep and swelling. Companion thermal hydraulic and neutronics assessments will also be required; these activities are planned for future years. Finally, integration of the multiple physics components through MOOSE is required to predict the core radial expansion and subsequent feedback effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low-Cost Aero Technology Demonstrations

The main focus of this work was to demonstrate the use of polymeric additive manufacturing (AM) to create tooling for both preforming and consolidation. Polymeric tooling was utilized where both modest and higher pressures are used for part consolidation. The key focus for the AM tooling development was for fabrication of complex structures such as ducting, C-channel stiffened skins, and airfoils where conventional male tooling would typically be trapped in the cured part. The AM tooling was evaluated for use as a tool master used to fabricate and re-shape deformable/re-formable mandrels based on SpinTech’s shape memory composite technology known as Smart Tooling. The AM tooling was also evaluated for use as a mold for composite infusion and consolidation. Key performance parameters were tracked for project schedule completion with each step comprising of “art to part” cycle time, cost, and model fidelity for dimensions, performance, and cost. The primary focus of this demonstration was to determine if a 50% cost reduction was achievable, for each AM tooling-set, as compared to conventional processes. UDRI leveraged project partner SpinTech, who manufactures tools and parts in these categories and thus provided a baseline regarding current best practices and provided valuable feedback during the entirety of this demonstration. This demonstration primarily focused on the use of AM tooling for fabrication of three composite component structures which are typically utilized in aircraft and comprise salient geometric features of broad interest. These components are often tooling intensive and have features requiring extraction of male tools which are usually trapped by the geometry. The three structures selected by the team included: 1) A one-piece airfoil shell comprised of compound contours where male tooling would be trapped unless the part were manufactured in two halves as is typically the case. 2) A one-piece duct used for air handling, comprised of compound contours where male tooling would be trapped unless the part were manufactured in two halves, or a washout mandrel were to be used. 3) A co-cured C-channel stiffened skin where typically C-channels would be individually manufactured and then bonded to a cured skin. The demonstration was comprised of three main tasks: • Task 1: AM Tool Feasibility Study – ensure the AM tooling meets the performance requirements as specified by SpinTech to match baseline performance. • Task 2: Complex Tool Demonstration – Fabricate tooling, preforms, and parts representative of an airfoil and duct. • Task 3: Large Aerostructure Fabrication Demonstration – Fabricate tooling, preforms, and part representative of a C-channel stiffened skin. With the conclusion of this project, a decision tree was developed to determine the key considerations necessary to determine if use of AM tooling for the three selected structures was able to attain the same quality as historically achieved on metallic tooling, while providing a significant cost reduction.

36 MATERIALS SCIENCE↗

Continued Verification of MOOSE Structural Mechanics Tools for Modeling Core Bowing Phenomena in Fast Reactors

Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism whereby increased power (which leads to temperature and flux gradients) influences the core to bow into less reactive configurations when the restraint system is properly designed. The phenomenon includes a complex interplay of radiation transport, duct temperature calculations involving fluid flow and heat transfer, and thermo-mechanical responses to the induced temperature and flux gradients. Structural material properties are also important to determining inelastic response to longer term flux gradients which cause irradiation creep and swelling. While core bowing provides a strong negative reactivity feedback when the restraint system is designed properly, it also results in additional forces between assemblies which increase the loads required to extricate them during refueling or control rod movement. Therefore, the restraint system must be designed with these tradeoffs in mind. The first stage of the work, which commenced in FY21 and continues through FY22, assesses thermo-mechanical modeling tools for producing core bowing predictions consistent with conventional tools. The Multiphysics Object Oriented Simulation Environment (MOOSE) Tensor Mechanics and Contact Modules are employed. This status report describes work on additional thermo-mechanical benchmark verification problems with increased complexity from the examples demonstrated in FY21. Several benchmark verification examples were selected from the IAEA verification and validation report. These examples involve clusters of ducts representative of a sector of a hexagonal reactor core which bow into each other and cause contact and load pad elevations, as well as single ducts subjected to irradiation fields undergoing swelling and subsequent bowing. The MOOSE-based results were compared to both IAEA benchmark participants’ results, analytic equations as available, and NUBOW-3D, a beam model code developed by Argonne National Laboratory. In every case, the MOOSE results agreed with other simulations results, providing additional verification basis of the tools for this particular physics application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY23 Status Report on MOOSE-Based Approaches to Modeling Core Bowing in Fast Reactors

Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism whereby increased power (which leads to temperature and flux gradients) influences the core to bow into less reactive configurations when the restraint system is properly designed. The phenomenon includes a complex interplay of radiation transport, duct temperature calculations involving fluid flow and heat transfer, and thermo-mechanical responses to the induced temperature and flux gradients. Structural material properties are also important to determining inelastic response to longer term flux gradients which cause irradiation creep and swelling. While core bowing provides a strong negative reactivity feedback when the restraint system is designed properly, it also results in additional forces between assemblies which increase the loads required to extricate them during refueling or control rod movement. Therefore, the restraint system must be designed with these tradeoffs in mind. The first stage of the work, which commenced in FY21 and continues through FY23, assesses thermo-mechanical modeling tools for producing core bowing predictions consistent with conventional tools. The Multiphysics Object Oriented Simulation Environment (MOOSE) Tensor Mechanics and Contact Modules are employed. This status report describes work on additional thermo-mechanical benchmark verification problems with increased complexity from the examples demonstrated in FY21 and FY22. Several benchmark verification examples were selected from the IAEA verification and validation report with increased number of ducts and more complex contact interaction behavior. These examples involve a full symmetric sector with restraint rings at multiple load pad locations to simulate a limited free-bow restraint system concept, as well as irradiation induced swelling and creep effects in a sector. In addition, improvements to the contact module sideset assignment were assessed and compared with previous MOOSE results to verify the contact behavior. The MOOSE-based results were compared to IAEA benchmark participants’ results. In every case, the MOOSE results agreed with other simulations results for estimating bowing behavior, providing additional verification basis of the tools for this particular physics application. Estimation of contact forces were mostly in agreement, with a few outlier results. A plan was suggested for dealing with the discrepancies with estimating contact force values. In addition, a 1-way coupling demonstration was performed using subchannel analysis code Pronghorn-SC and MOOSE on an ABR-1000-design sodium-cooled fast reactor assembly to evaluate coolant and duct wall temperatures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗