Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drilling analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

NETL Coal Energy Atlas: A Collection of Coal/Energy Related Maps

The NETL Coal Energy Atlas contains a comprehensive collection of coal and energy-related maps and graphics curated by the National Energy Technology Laboratory (NETL) Systems Analysis group. It serves as a living document providing an overview of the U.S. coal and energy sectors. The volume is structurally organized into six key thematic areas. Ultimately, the atlas functions as a modular baseline for data integration, allowing researchers to drill down into specific regional locations or customize geographic base layers for advanced systems analysis.

bituminous coal↗

Mars Deep Drill - A Mission Concept for the Next Decade

In the not too distant future, NASA may consider sending a robotic mission to Mars to drill tens of meters below the surface to search for evidence of life. Mars science groups, including NASA's Mars Exploration Program Analysis Group (MEPAG), have repeatedly concluded that in situ scientific analyses of samples from significant depths below the surface are important for understanding Mars in general and for searching for evidence of past or present life in particular. Furthermore, there are several ongoing technology developments for relevant drills, the readiness of which seem promising for use by the second decade of this century. By accessing and analyzing material from tens of meters below the surface, in situ science investigations may help answer some important questions about Mars, in particular about whether life ever existed there. Drilling is a proven technique for terrestrial applications that appears viable for accessing Martian subsurface samples and bringing them to the surface for analysis by a variety of instruments. An end-to-end mission concept for a Deep Drill mission has been developed and appears feasible for launch in the next decade.

Mars↗

A machine learning degradation model for electrochemical capacitors operated at high temperature

Electrochemical capacitors (ECs) have only recently been considered as an alternative power source for telemetry sensors of drilling equipment for geothermal or oil and gas exploration. The lifecycle analysis and modelling of ECs is underrepresented in literature in comparison to other storage devices e.g. Li-ion batteries. This paper investigates the degradation of ECs when cycled outside the manufacturer-specified operating temperature envelope and proposes a machine learning-based approach for modelling the degradation. Experimental results show that end of life, defined as a 30% decrease in capacitance, occurs at 1,000 cycles when the environmental temperature exceeds the maximum operating temperature by 30%. The life-cycle test data is then used as an input to a Gaussian process regression (GPR) algorithm to predict the capacitance fade trend. The GPR is validated on a total of nine commercial cells from two different manufacturers, achieving an average root mean squared percent error of less than 2% and a mean calibration score of 93% when referenced to a 95% confidence interval. The model can be utilized to determine the EC degradation rate at a range of operating temperature values.

42 ENGINEERING↗

Molecular Analyzer for Complex Refractory Organic-Rich Surfaces (MACROS)

The Molecular Analyzer for Complex Refractory Organic-rich Surfaces, MACROS, is a novel instrument package being developed at NASA Goddard Space Flight Center. MACROS enables the in situ characterization of a sample's composition by coupling two powerful techniques into one compact instrument package: (1) laser desorption/ionization time-of-flight mass spectrometry (LDMS) for broad detection of inorganic mineral composition and non-volatile organics, and (2) liquid-phase extraction methods to gently isolate the soluble organic and inorganic fraction of a planetary powder for enrichment and detailed analysis by liquid chromatographic separation coupled to LDMS. The LDMS is capable of positive and negative ion detection, precision mass selection, and fragment analysis. Two modes are included for LDMS: single laser LDMS as the broad survey mode and two step laser mass spectrometry (L2MS). The liquid-phase extraction will be done in a newly designed extraction module (EM) prototype, providing selectivity in the analysis of a complex sample. For the sample collection, a diamond drill front end will be used to collect rock/icy powder. With all these components and capabilities together, MACROS offers a versatile analytical instrument for a mission targeting an icy moon, carbonaceous asteroid, or comet, to fully characterize the surface composition and advance our understanding of the chemical inventory present on that body.

Getty, Stephanie A.↗

Mars Hand Lens Imager (MAHLI) efforts and observations at the “Rocknest” Eolian sand shadow in Curiosity’s Gale Crater field site

The Mars Science Laboratory (MSL) mission is focused on assessing the past or present habitability of Mars, through interrogation of environment and environmental records at the Curiosity rover field site in Gale crater. The MSL team has two methods available to collect, process and deliver samples to onboard analytical laboratories, the Chemistry and Mineralogy instrument (CheMin) and the Sample Analysis at Mars (SAM) instrument suite. One approach obtains samples by drilling into a rock, the other uses a scoop to collect loose regolith fines.

Edgett, K. S.↗

Carbon and Sulfur Isotopic Composition of Yellowknife Bay Sediments: Measurements by the Sample Analysis at Mars (SAM) Quadrupole Mass Spectrometer

Since landing at Gale Crater in Au-gust 2012, the Sample Analysis at Mars (SAM) instru-ment suite on the Mars Science Laboratory (MSL) “Curiosity” rover has analyzed solid samples from the martian regolith in three locations, beginning with a scoop of aeolian deposits from the Rocknest (RN) sand shadow. Curiosity subsequently traveled to Yellowknife Bay, where SAM analyzed samples from two separate holes drilled into the Sheepbed Mudstone, designated John Klein (JK) and Cumberland (CB). Evolved gas analysis (EGA) of all samples revealed the presence of H2O as well as O-, C- and S-bearing phas-es, in most cases at abundances below the detection limit of the CheMin instrument. In the absence of definitive mineralogical identification by CheMin, SAM EGA data can help provide clues to the mineralogy of volatile-bearing phases through examination of tem-peratures at which gases are evolved from solid sam-ples. In addition, the isotopic composition of these gas-es may be used to identify possible formation scenarios and relationships between phases. Here we report C and S isotope ratios for CO2 and SO2 evolved from the JK and CB mudstone samples as measured with SAM’s quadrupole mass spectrometer (QMS) and draw com-parisons to RN.

Franz, H. B.↗

Optimizing Deep Geothermal Drilling for Energy Sustainability in the Appalachian Basin

This study investigates the geological and geomechanical characteristics of the MIP 1S geothermal well in the Appalachian Basin to optimize drilling and address the wellbore stability issues encountered. Data from well logs, sidewall core analysis, and injection tests were used to derive elastic and rock strength properties, as well as stress and pore pressure profiles. A robust 1D-geomechanical model was developed and validated, correlating strongly with wellbore instability observations. This revealed significant wellbore breakout, widening the diameter from 12 ¼ inches to over 16 inches. Advanced technologies like Cerebro Force™ In-Bit Sensing were used to monitor drilling performance with high accuracy. This technology tracks critical metrics such as bit acceleration, vibration in the x, y, and z directions, Gyro RPM, stick-slip indicators, and bending on the bit. Cerebro Force™ readings identified hole drag caused by poor hole conditions, including friction between the drill string and wellbore walls and the presence of cuttings or debris. This led to higher torque and weight on bit (WOB) readings at the surface compared to downhole measurements, affecting drilling efficiency and wellbore stability. Optimal drilling parameters for future deep geothermal wells were determined based on these findings.

Environmental Sciences & Ecology↗

Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water

The presence of water-ice in the Martian subsurface is a subject of much debate and excited speculation. Recent results from the gammaray spectrometer (GRS) on board NASA's Mars Odyssey spacecraft indicate the presence of large amounts of hydrogen in regions of predicted ice stability. The combination of chemistry, low gravitational field (3.71 m/s(exp 2)) and a surface pressure of about 6.36 mbar at the mean radius, place limits on the stability of H2O on the surface, however, results from the GRS indicate that the hydrogen rich phase may be present at a depth as shallow as one meter in some locations on Mars. The potential for water on Mars leads directly to the speculation that life may once have existed there, since liquid water is the unifying factor for environments known to support life on Earth. Lubricant-free drilling has been considered as a means of obtaining water-rich subsurface samples on Mars, and two recent white papers sponsored by the Mars Program have attempted to identify the problems associated with this goal. The two major issues identified were: the engineering challenges of drilling into a water-soil mixture where phase changes may occur; and the potential to compromise the integrity of in-situ scientific analysis due to contamination, volatilization, and mineralogical or chemical changes as a result of processing. This study is a first attempt to simulate lubricantfree drilling into JSC Mars-1 simulant containing up to 50% water by weight. The goal is to address the following: 1) Does sample processing cause reactions or changes in mineralogy which will compromise the interpretation of scientific measurements conducted on the surface? 2) Does the presence of water-ice in the sample complicate (1)? 3) Do lubricant-free drilling and processing leave trace contaminants which may compromise our understanding of sample composition? 4) How does the torque/power required for drilling change as a function of water content and does this lead to unexpected thermal effects?

Menard, J.↗

Shallow Geothermal Potential of the Snake River Plain

The Snake River Plain (SRP) terrestrial heat flow and subsurface thermal regime are not well understood but are important for assessing the local geothermal resource potential, both for conventional and for Enhanced Geothermal Systems (EGS) development in the region. Resource evaluation for the SRP is complicated by the disparate data density, along with the known lateral advection of heat in the Eastern Snake River Plain Aquifer and vertical heat transport by fluids in the bounding faults, primarily in the southwestern section. Fortunately, recent studies, e.g., the Snake River Plain Play Fairway Analysis, the Idaho FORGE site, and site-specific investigations, which included drilling within the Camas Prairie and on the Mountain Home Air Force Base, near Twin Falls, and in the Eastern Snake River Plain as part of the HOTSPOT Project, add both additional drilling and geophysical data. The SMU Geothermal Laboratory has conducted detailed studies of SRP tectonics and heat flow since the 1970's and used this knowledge as part of the EGS geothermal potential estimation for the conterminous United States in 2006 and again in 2011, calculating geothermal potential from 3.5 km to 10 km depth. Recent temperature modeling refined the calculation methodology to estimate shallow (1 km to 4 km) resource potential using an improved thermal conductivity model and incorporation of shallow groundwater flow. By incorporating the new SRP geology, geophysics, and 206 thermal data sites into the SMU thermal modeling methodology, this project updates the resource estimate for the SRP, and generates new temperature-at-depth maps for the shallow subsurface (1 km to 4 km). The project results highlight the EGS potential resource areas (=150°C) and areas with more exploration risks based on minimal and/or low-quality data. The newest temperature modeling results suggest EGS potential is near five times greater in the SRP than previously estimated.

EGS↗

Utah FORGE: Well 56-32 Drilling Data and Logs

This dataset consists of drilling data (Pason data spreadsheets, daily reports, days v. depth, mud logs), Schlumberger logs (FMI, shear anisotropy analysis, memory, sonic, array induction/spectral density/dual spaced neutron/gamma ray/caliper, spectral GR/temperature, and Gardner density correlation), and an end of well report (EOWR) for Utah FORGE well 56-32. This is a vertical well that will be used for seismic monitoring. It was drilled between February 7th and February 21st 2021 to a depth of 9,145 feet. More information about this well can be found at: https://utahforge.com/2021/02/09/drilling-progress-of-well-56-32/ (linked below)

15 GEOTHERMAL ENERGY↗

Sulphur-bearing Compounds Detected by MSL SAM Evolved Gas Analysis of Materials from Yellowknife Bay, Gale Crater, Mars

The Sample Analysis at Mars (SAM) and Chemistry and Mineralogy (CheMin) instruments on the Mars Science Laboratory (MSL) analysed several subsamples of sample fines (<150 μm) from three sites in Yellowknife Bay, an aeolian bedform termed Rocknest (hereafter "RN") and two samples drilled from the Sheepbed mudstone at sites named John Klein ("JK") and Cumberland ("CB"). SAM's evolved gas analysis (EGA) mass spectrometry detected H2O, CO2, O2, H2, SO2, H2S, HCl, NO, OCS, CS2 and other trace gases. The identity of evolved gases and temperature (T) of evolution can support mineral detection by CheMin and place constraints on trace volatile-bearing phases present below the CheMin detection limit or difficult to characterize with XRD (e.g., X-ray amorphous phases). Here, we focus on potential constraints on phases that evolved SO2, H2S, OCS, and CS2 during thermal analysis.

McAdam, A. C.↗

Vacuum Sealable Container (VSC) and Astronaut Lunar Drill (ALD) for Artemis

Introduction: NASA’s Artemis Program is under development to send first woman and next man to the Moon. Artemis will utilize a suite of new technology for Lunar exploration, including new space vehicles, new space suits, and new Astronaut Tools. Honeybee Robotics has been working with NASA JSC to develop a new Vacuum Sealable Container (VSC) and new Astronaut Lunar Drill (ALD) for the upcoming Artemis missions. Vacuum Sealable Container: Sample return continues to be the “Holy Grail” of space exploration, allowing for the analysis of materials using Earth-based laboratories instead of needing to miniaturize and ruggedize instrumentation for space. The Apollo missions to the Moon had several kinds of Sealable Containers which brought back Lunar samples for analysis [1]. These samples are still being analyzed, fifty years later. The VSC requirements are different from that for Apollo containers and as such, new development was required. One major difference between Artemis samples and those from Apollo is the desire to bring back volatiles which may be part of lunar regolith. The VSC is designed to withstand a high-pressure differential caused by sublimating volatiles. Because of the new, stricter sealing requirements, additional features have been added to the VSC. For example, the seal on the container is required to be more robust, thus required more force to actuate, and the seal must be locked in place with a secondary mechanism. Astronaut Lunar Drill: The ALD is designed to be a multi-functional platform for Lunar sample acquisition. The drill builds on lessons learned from the Apollo Lunar Surface Drill (ALSD), as well as Honeybee’s long history of mechanized sample acquisition devices for space [2]. The main functionality of the ALD is Deep Core Regolith Drilling. Additional functionality includes Surface Rock Coring (SRC), and GeoTech Tools (GTT). The ALD is a rotary-percussive drill designed with deep drilling in mind. The ALD is currently designed to have decoupled rotary and percussion subsystems to allow for maximum battery life and reduced fatigue on the crewmember. Honeybee drill technology will automatically engage the percussion when needed to drill at maximum efficiency. The mechanized drill stand helps improve drilling efficiency; the system utilizes advanced drilling algorithms which only require the crewmember to hold a single switch. Additionally, the stand aids in extraction of deep cores, something which was a problem on Apollo. The SRC functionality of the ALD utilizes Honeybee’s Eccentric Tube Core Breakoff technology to collect and retain rock core samples. This technology has also been infused into the Perseverance rover mission. The ALD is removable from the stand to allow crewmembers to collect samples from large boulders. Bringing back rock cores samples instead of full rocks allows for a wider variety of samples to be returned to Earth for study and puts them in a uniform form-factor for effective sealing and analysis. SRC bits will utilize the power of the drill’s percussion system to drill hard Lunar rocks and expedite sample acquisition. The mechanized stand on the ALD allows for additional attachments for taking geotechnical measurements with a Static Cone Penetrometer (SCP) and a Shear Vane (SV). With the stand, the ALD can take SCP measurements with the touch of a button, storing data for return to Earth. SV measurements utilize the ALD’s Rotary motor to spin the vanes in a controlled manner, getting clean data untampered by human error. References: [1] Bar Cohen and Zacny (2009), Drilling in Extreme Environments - Penetration and Sampling on Earth and Other Planets, Wiley. [2] Bar-Cohen and Zacny, Advances in Terrestrial and Extraterrestrial Drilling, CRC Press. [3] Myrick (2003), Core Break-off Mechanism. US Patent No. 6,550,549 Acknowledgements: This work has been supported by NASA via SBIR Phase 3.

Artemis↗

Geothermal Play Fairway Analysis Best Practices

Play fairway analysis (PFA) is a methodology that can improve success rates for geothermal exploration drilling, thus reducing the costs of geothermal projects while facilitating development in new areas. It was originally developed for the oil and gas industry, but has been adapted for discovering geothermal resources over the last decade. The geothermal PFA methodology involves systematically screening a set geographic area for promising qualities typically related to the presence of heat, permeability, and fluid. Successful application of PFA can identify hidden hydrothermal systems. From 2014 to 2021 the U.S. Department of Energy (DOE) Geothermal Technologies Office (GTO) supported the development of PFA for geothermal resources through awards to 11 research teams across the country. The goal of these projects was to advance and adapt PFA for geothermal exploration to produce regional-scale maps that reduce exploration uncertainty. This report is an outcome of the NREL-led PFA Retrospective project, which compiled, synthesized, analyzed the results of GTO's geothermal PFA program. Ultimately, we find that these projects greatly advanced approaches to geothermal exploration and resulted in extensive new data and new discoveries of unrecognized geothermal systems. We used the results to distill best practices in this report and to provide guidance for future applications of geothermal PFA.

15 GEOTHERMAL ENERGY↗

Dynamic Positioning System (DPS) Risk Analysis Using Probabilistic Risk Assessment (PRA)

The National Aeronautics and Space Administration (NASA) Safety & Mission Assurance (S&MA) directorate at the Johnson Space Center (JSC) has applied its knowledge and experience with Probabilistic Risk Assessment (PRA) to projects in industries ranging from spacecraft to nuclear power plants. PRA is a comprehensive and structured process for analyzing risk in complex engineered systems and/or processes. The PRA process enables the user to identify potential risk contributors such as, hardware and software failure, human error, and external events. Recent developments in the oil and gas industry have presented opportunities for NASA to lend their PRA expertise to both ongoing and developmental projects within the industry. This paper provides an overview of the PRA process and demonstrates how this process was applied in estimating the probability that a Mobile Offshore Drilling Unit (MODU) operating in the Gulf of Mexico and equipped with a generically configured Dynamic Positioning System (DPS) loses location and needs to initiate an emergency disconnect. The PRA described in this paper is intended to be generic such that the vessel meets the general requirements of an International Maritime Organization (IMO) Maritime Safety Committee (MSC)/Circ. 645 Class 3 dynamically positioned vessel. The results of this analysis are not intended to be applied to any specific drilling vessel, although provisions were made to allow the analysis to be configured to a specific vessel if required.

Thigpen, Eric B.↗

Dynamic Positioning System (DPS) Risk Analysis Using Probabilistic Risk Assessment (PRA)

The National Aeronautics and Space Administration (NASA) Safety & Mission Assurance (S&MA) directorate at the Johnson Space Center (JSC) has applied its knowledge and experience with Probabilistic Risk Assessment (PRA) to projects in industries ranging from spacecraft to nuclear power plants. PRA is a comprehensive and structured process for analyzing risk in complex engineered systems and/or processes. The PRA process enables the user to identify potential risk contributors such as, hardware and software failure, human error, and external events. Recent developments in the oil and gas industry have presented opportunities for NASA to lend their PRA expertise to both ongoing and developmental projects within the industry. This paper provides an overview of the PRA process and demonstrates how this process was applied in estimating the probability that a Mobile Offshore Drilling Unit (MODU) operating in the Gulf of Mexico and equipped with a generically configured Dynamic Positioning System (DPS) loses location and needs to initiate an emergency disconnect. The PRA described in this paper is intended to be generic such that the vessel meets the general requirements of an International Maritime Organization (IMO) Maritime Safety Committee (MSC)/Circ. 645 Class 3 dynamically positioned vessel. The results of this analysis are not intended to be applied to any specific drilling vessel, although provisions were made to allow the analysis to be configured to a specific vessel if required.

Thigpen, Eric B.↗

In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols

The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.

Mars surface operations↗

Microbial Habitability in Gale Crater: Sample Analysis at Mars (SAM) Instrument Detection of Microbial Essential Carbon and Nitrogen

Chemical analyses of Mars soils and sediments from previous landed missions have demonstrated that Mars surface materials possessed major (e.g., P, K, Ca, Mg, S) and minor (e.g., Fe, Mn, Zn, Ni, Cl) elements essential to support microbial life. However, the detection of microbial essential organic-carbon (C) and nitrate have been more elusive until the Mars Science Laboratory (MSL) rover mission. Nitrate and organic-C in Gale Crater, Mars have been detected by the Sample Analysis at Mars (SAM) instrument onboard the MSL Curiosity rover. Eolian fines and drilled sedimentary rock samples were heated in the SAM oven from approximately 30 to 860 degrees Centigrade where evolved gases (e.g., nitrous oxide (NO) and CO2) were released and analyzed by SAM’s quadrupole mass spectrometer (MS). The temperatures of evolved NO was assigned to nitrate while evolved CO2 was assigned to organic-C and carbonate. The CO2 releases in several samples occurred below 450 degrees Centigrade suggesting organic-C dominated in those samples. As much as 7 micromoles NO3-N per gram and 200 micromoles CO2-C per gram have been detected in the Gale Crater materials. These N and C levels coupled with assumed microbial biomass (9 x 10 (sup -7) micrograms per cell) C (0.5 micrograms C per micrograms cell) and N (0.14 micrograms N per micrograms cell) requirements, suggests that less than 1 percent and less than 10 percent of Gale Crater C and N, respectively, would be required if available, to accommodate biomass requirements of 1 by 10 (sup 5) cells per gram sediment. While nitrogen is the limiting nutrient, the potential exists that sufficient N and organic-C were present to support limited heterotrophic microbial populations that may have existed on ancient Mars.

Sutter, B.↗