Engineering PapersSearch

SEARCH · Engineering Papers

Results for “double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Portable Cleanroom for NASA OSIRIS-REx Mission Deintegration

NASA Johnson Space Center (JSC) Infrastructure and Astromaterials Acquisition & Curation Office completed construction and commissioning of the OSIRIS-REx (OREx) Deintegration portable cleanroom at the Utah Test and Training Range (UTTR). The new portable cleanroom was designed to receive the OREx sample return capsule from the landing point on the range to an ISO7 environment. Scientists used the portable clean-room to deintegrate the sample canister from the sample return capsule. Once separated, the sample canister was put in a container under nitrogen purge for transportation to B31 at the Johnson Space Center for astromaterial sample extraction, preliminary analysis, and long-term curation. The portable cleanroom was built by a subcontractor at their facility and then deconstructed to be transported to the remote location at UTTR. Since construction was completed in a remote location all tools and materials had to be transported from contractor site in Dallas, TX. The cleanroom was constructed within an existing facility, which provided conditioned air, electric power, and protection from the elements. Careful coordination was required between the host facility, cleanroom contractor, mission scientists, and JSC facilities and curation personnel. An existing anteroom at JSC was transported to UTTR and added to the portable cleanroom after there was concern about contamination without one for personnel entry/exit. The scientific study of organics is critical for the mission, so a stringent contamination control plan was implemented for low organics. Given these mission requirements the cleanroom construction materials were carefully selected to not hinder the scientific search for amino acids and the study of organics in the samples. The same cleanroom contractor that built the long-term astromaterial curation cleanroom back at JSC Houston, TX was selected to build the portable cleanroom and instructed to use the same materials. The cleanroom had double doors to open and allow the sample return capsule to fit into the cleanroom on its stand and be transferred to a clean stand already in the cleanroom. The portable cleanroom successfully completed its mission and the sample canister was safely deintegrated and transported to JSC under nitrogen purge.

astromaterials curation

Dynamics of groups around interacting double ellipticals: Measuring dark matter haloes

Binary galaxies, as binary stars, are important to measure masses, as suggested by Page (1952). Because three orbit parameters are measurable for galaxies at one instant of time, severe uncertainties remain in the orbit and mass determinations. These uncertainties can partly be overcome by statistical studies of selected samples and/or n-body simulations. Close double galaxies (and isolated galaxies) could also be useful to estimate dynamical masses if we can find test particles around them. Interacting elliptical pairs or dumb-bell galaxies are found with a large range, between 0-1200 km s(exp -1), of relative radial velocities. Standard 2-body orbit calculations, highly uncertain due to projection factors, suggest for the largest velocity differences very large galaxy masses, if the systems are bound and stationary. However, recent n-body simulations model these binaries as galaxies captured from hyperbolic orbits, requiring masses of order a few times 10(exp 11) solar maximum (Borne et al. 1988), but producing systems that are short lived. A different picture appears when we study observationally the dynamical mass of interacting double ellipticals using faint satellite galaxies. These satellites contribute little luminosity and, presumably, little mass to the system. The authors present results of two such groups, basically forming systems of test particles, around the dumb-bells NGC 4782/3 and IC 5049. They also briefly discuss the satellite group around the central dumb-bell in the cluster Sersic 40/6. Apparently, they detect large quantities of dark matter in the vicinity of these dumb-bell galaxies, because the system masses of approx. 4.5 times 10(exp 13) solar mass and 8 times 10(exp 13) solar mass for NGC 4782/3 and IC 5049, respectively, are quite high. Likewise, the mass of the Sersic 40/6 inner core is 7 times 10(exp 13) solar mass. The possibility that a common massive dark matter halo increases the merging times of these types of galaxies is suggested. Here, the authors assume H sub o = 100 km s (exp -1) Mpc(exp -1).

Quintana, H.

Dual transposon sequencing profiles the genetic interaction landscape in bacteria

Gene redundancy complicates systematic characterization of gene function as single-gene deletions may not produce discernible phenotypes. We report dual transposon sequencing (dual Tn-seq), a platform for assaying the fitness of a comprehensive double mutant pool in parallel. Dual Tn-seq couples random barcode transposon site sequencing with the Cre-lox system, enabling deep sampling of 73% of the 1.3 million possible double gene deletions in Streptococcus pneumoniae. The genetic interactions identified span a wide range of biochemical processes, revealing new factors in presumably well-studied pathways, exemplified by a cytidine triphosphate synthase PyrJ. Moreover, this approach should permit further investigation of growth condition–specific genetic interactions. Because dual Tn-seq does not require the construction of a large array of single mutants, it should be readily adaptable to various microorganisms.

CTP synthesis

Revealing the Moon's Taurus‐Littrow Landslide via Integrated Analysis of Pristine Apollo 17 Soil Core 73001/2

The “light mantle” deposit at the base of South Massif in the Moon's Taurus‐Littrow Valley was a primary science target for the Apollo 17 exploration. The possibility that it was a landslide triggered by ejecta from Tycho Crater is critical for establishing the age of Tycho and constraining recent lunar impact chronology; however, the mechanism of emplacement of the deposit has recently been questioned. The newly opened 73001/73002 double drive tube from Station 3 sampled 70.6 cm deep into the regolith and represents the first stratigraphic section of an extraterrestrial landslide deposit returned to Earth. Here we provide an overview of the stratigraphy of the 73001/73002 core based on top to bottom variations revealed by coordinated laboratory analyses and explore constraints on the emplacement of the light mantle deposit. Briefly, the upper ∼10 cm of 73002 contains a disturbed zone from space weathering and emplacement of ejecta from a nearby crater that excavated and ejected basaltic material. Below 10 cm is a nearly uniform unit of immature regolith. These data support a single event for the emplacement of the deposit at this location, followed by weathering and mixing of materials from nearby crater ejecta in the upper 10 cm. Slight variations in chemistry and clast components may reflect the relative stratigraphy of the South Massif slope, with material toward the bottom of 73001 originating from lower slopes and material from higher up in the core representing regolith from higher up the South Massif slopes.

58 GEOSCIENCES

Holographic nondestructive testing with impact excitation.

Review of some experimental results of bond flaw detection in composite materials by holographic recording of the surface of samples subjected to mechanical impact. The resulting deformation of the samples recorded in a sequence of double exposure holograms at increasingly longer time intervals after impact renders the presence of flaws observable. A proposed deformation enhancement technique increases detection sensitivity and is helpful in visualizing smaller flaws.

Chu, W. P.

Changes in "thermal lens" measure diffusivity

In an extension of "thermal lens" effect to new applications and better resolution, two laser beams combine to rapidly measure thermal diffusivity and other molecular dynamic properties. New double-beam technique handles very small samples unlike classical techniques for measuring diffusivity. It can be used for measurements on samples undergoing stress, making it applicable to data collection for structural engineering.

Gupta, A.

High Resolution Triple Axis X-Ray Diffraction Analysis of II-VI Semiconductor Crystals

The objective of this research program is to develop methods of structural analysis based on high resolution triple axis X-ray diffractometry (HRTXD) and to carry out detailed studies of defect distributions in crystals grown in both microgravity and ground-based environments. HRTXD represents a modification of the widely used double axis X-ray rocking curve method for the characterization of grown-in defects in nearly perfect crystals. In a double axis rocking curve experiment, the sample is illuminated by a monochromatic X-ray beam and the diffracted intensity is recorded by a fixed, wide-open detector. The intensity diffracted by the sample is then monitored as the sample is rotated through the Bragg reflection condition. The breadth of the peak, which is often reported as the full angular width at half the maximum intensity (FWHM), is used as an indicator of the amount of defects in the sample. This work has shown that high resolution triple axis X-ray diffraction is an effective tool for characterizing the defect structure in semiconductor crystals, particularly at high defect densities. Additionally, the technique is complimentary to X-ray topography for defect characterization in crystals.

Volz, H. M.

Enabling probabilistic learning on manifolds through double diffusion maps

Here, we present a generative learning framework for probabilistic sampling that extends Probabilistic Learning on Manifolds (PLoM), which is designed to generate statistically consistent realizations of a random vector in a finite-dimensional Euclidean space, informed by a (representative) set of observations. In its original form, PLoM constructs a reduced-order probabilistic model by combining three main components: (a) kernel density estimation to approximate the underlying probability measure, (b) Diffusion Maps to characterize the manifold of the data, and (c) a reduced-order Itô Stochastic Differential Equation (ISDE) to sample from the learned distribution. However, its sampling dynamics are posed in the ambient space and the retained number of reduced coordinates is chosen by projection-reconstruction error. In practice, this often (i) requires more coordinates than the data’s intrinsic dimension to achieve stable sampling and (ii) lacks a smooth, basis-independent lifting back to the data domain; moreover, standard Diffusion Maps emphasize harmonic eigenfunctions and can miss non-harmonic latent structure. We address these limitations by decoupling geometry learning from sampling: a first Diffusion Maps pass identifies non-harmonic coordinates on which we formulate a full-order ISDE directly in the latent space, while Double Diffusion Maps captures multiscale geometric features and Geometric Harmonics (GH) learns a smooth lifting map to the ambient variables that is independent of the particular diffusion basis. This hybrid design preserves the system’s dynamical richness with a compact geometric representation and enables principled out-of-sample inference. The effectiveness and robustness of the proposed method are illustrated through two numerical studies: one based on data generated from two-dimensional Hermite polynomial functions and another based on high-fidelity simulations of a detonation wave in a reactive flow.

Double diffusion maps

Characterization of Ceramic Matrix Composite Combustor Components: Pre and Post Exposure

The pursuit of lower emissions and higher performance from gas turbine engines requires the development of innovative concepts and the use of advanced materials for key engine components. One key engine component is the combustor, where innovative design and material improvements have the potential to lower emissions. Efforts to develop a High Speed Civil Transport with low emissions were focused on the evaluation of combustor concepts with liners fabricated from a ceramic matrix composite of silicon carbide fibers in a silicon carbide matrix (SiC/SiC). The evaluation of SiC/SiC composites progressed from simple coupons (to establish a first-order database and identify operant failure mechanisms and damage accumulation processes), to feature-based subelements (to assess fabricability and in situ material response), to actual components (to assess structural integrity, dimensional, and compositional fidelity) tested under simulated engine conditions. As in the case of all evolutionary material and process work, a key element to resolving fabrication issues is the evaluation of witness areas taken from fabricated components before testing the actual component. The witness material from these components allowed microstructural and mechanical testing to be performed and compared to the ideal, flat panel, conditions and data that are typical of basic characterization. This also allowed samples of similar design to be taken from components after 115 hours of combustion exposure. Testing consisted of tensile, double notch shear, ring burst, and thermal conductivity that sampled various regions of the components. The evaluation of the witness material allowed an understanding of the fabrication process, highlighting critical issues, in an early phase of the learning curve development of these configuration and material unique parts. Residual property testing, after exposure, showed if degradation of the material under actual service conditions was occurring. This paper will present the results of this critical testing. Evaluations that consider the degree of complexity of the fabricated part were established to relate in situ performance to that of flat panel based coupons. Nondestructive evaluation was used throughout the evaluation process. These results will also be discussed as an aid in understanding the test results.

Ojard, G.

Mars Sample Receiving Facility Research and Development to Enable Preservation, Safe Containment, and Scientific Research of Martian Samples on Earth

NASA and ESA are working together to plan a joint campaign to potentially bring back the first Martian samples to Earth in the early 2030s. On the surface of Mars, the Mars 2020Perseverance Rover is selecting and packaging samples that could be returned to Earth for careful examination by an international team of scientists. In preparation for this historic sample return, advance planning is underway to design and build a Mars Sample Receiving Facility (SRF) in the mid-2020s. In 2022, a Mars Sample Receiving Facility Assessment Study(MSAS) will be conducted to further define construction modality and capability options for a facility in the conterminous United States. Since Mars Sample Return (MSR) is currently categorized as a planetary protection restricted Earth return, this new facility would feature biosafety level 4 (BSL-4)-like high containment to protect Earth’s biosphere from any potential hazard. In addition, the facility also requires integration of cleanroom technologies to mitigate against terrestrial contamination and preserve sample integrity for science investigations. The integration of both clean handling and high containment requires significant technology research and development (R&D) by the mid-2020s to support the definition and planning of a SRF before commencing the site specific design phase. The SRF project will need to solidify the inorganic, organic, and biological contamination control (CC) requirements for the facility. This could entail a translation of Mars 2020 mission CC requirements for geologic material to engineering requirements for surfaces and airborne molecular contamination inside isolators and cleanrooms. In tandem, the project will need to determine precision cleaning and sterilization approaches for cleanrooms, isolators, equipment, and tools. Initial material selections for the facility construction materials, cleanrooms, isolators, and BSL-4 suits/garments are an important activity. The recent construction of the OSIRIS-REx and Hayabusa2 curation cleanroom laboratories greatly benefited from early materials testing, before the design phase, to reduced organic outgassing and particulate shedding inside the laboratory. While the early biohazard investigations in the SRF may deem the samples safe to release to laboratories throughout the world, sterilization methods need to be defined to safely release Martian samples. One key aspect of enabling simultaneous sample containment and cleanliness is the concept of a Double-Walled Isolator (DWI) that ESA has been pursuing. Further R&D is needed about DWIs, sample handling, and instrumentation interfaces before beginning the SRF site specific design phase. A working isolator/DWI engineering model should be developed and fabricated. Isolator sizes, connections, pass-through antechambers, and configurations and basic interfaces with instruments and tools as well as the use of robotic, mechanical, and/or human manipulation need to be considered. Inert high purity gas supply (one-pass or recirculation) and other isolator utilities must be determined. Special accommodations for large instruments (e.g., XCT,SEM, etc.) need to be developed. Techniques for opening the sample tubes packaged by M2020and extracting the headspace gas while keeping samples pristine will be challenging, requiring additional R&D, and engagement of the M2020 project. In addition, careful micromanipulation for subdivision and packaging of samples will also need to be included. These combined R&D activities are important before commencing the SRF design phase to ensure safe biohazard containment, sample preservation, and science integrity for the samples that would be studied in the SRF and in laboratories around the world.

mars sample return

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.

Observations of multiple nucleus galaxies

Disturbed galaxies with two nuclei display the final state of the interaction process of two galaxies (Kollatschny et al., 1986; Fricke and Kollatschny, 1989). A few of these double nucleus galaxies contain Seyfert nuclei. Making the assumption that the Seyfert galaxies Mkn 231 and Mkn 273 are galaxies in the final state of merging, having strong tidal arms but unresolved nuclei, one can estimate that 4 percent of all Seyfert galaxies are in the merging process. The luminosities of multiple nucleus Seyfert galaxies are extremely high in comparison to morphologically undisturbed Seyfert galaxies. In a table, mean values of the visual and blue luminosities and of the far-infrared and radio (6 cm) luminosities as well as the H alpha fluxes are listed for both classes are shown. In addition, the authors have separated Seyfert 1 and Seyfert 2 galaxies. In all cases the luminosities of double nucleus Seyfert galaxies are higher by a factor of more than two with respect to undisturbed Seyfert galaxies. This result might be explained by higher luminosities in the early phases of a Seyfert's life-under the assumption that the nonthermal activity is triggered by tidal interaction-and/or additional strong starburst phenomena. Due to strong nuclear absorption, the UV spectra of these Seyfert nuclei are unusually weak. Corresponding to the Seyfert survey, the authors obtained the H alpha and far infrared radiation (FIR) luminosities as well as the (0III)5007/H beta line ratios of a small sample of non-Seyfert nuclei in double nucleus galaxies. The direct image and the velocity field of the double starburst galaxy Mkn 788 (Kollatschny et al., 1986) are shown. The authors compared their measurements with those of normal interacting galaxies of Keel et al. (1985) and Bushouse (1987). The mean FIR luminosity per nucleus in multiple systems is the same as that of interacting galaxies. But the mean H alpha luminosities as well as the (OIII)/H beta line ratios are higher by a factor of 1.5-2 than those of normal interacting galaxies.

Kollatschny, W.

Exploring toroidal anvil profiles for larger sample volumes above 4 Mbar

Abstract With the advent of toroidal and double-stage diamond anvil cells (DACs), pressures between 4 and 10 Mbar can be achieved under static compression, however, the ability to explore diverse sample assemblies is limited on these micron-scale anvils. Adapting the toroidal DAC to support larger sample volumes offers expanded capabilities in physics, chemistry, and planetary science: including, characterizing materials in soft pressure media to multi-megabar pressures, synthesizing novel phases, and probing planetary assemblages at the interior pressures and temperatures of super-Earths and sub-Neptunes. Here we have continued the exploration of larger toroidal DAC profiles by iteratively testing various torus and shoulder depths with central culet diameters in the 30–50 µm range. We present a 30 µm culet profile that reached a maximum pressure of 414(1) GPa based on a Pt scale. The 300 K equations of state fit to our P–V data collected on gold and rhenium are compatible with extrapolated hydrostatic equations of state within 1% up to 4 Mbar. This work validates the performance of these large-culet toroidal anvils to > 4 Mbar and provides a promising foundation to develop toroidal DACs for diverse sample loading and laser heating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Rapid Crystallization of Zeolites with Controllable Defects: Disentangling Fluoride Concentration and pH Using NH 4 F

Zeolite synthesis is typically conducted either under basic conditions or in neutral fluoride media using hydrofluoric acid (HF). While basic (OH − ) conditions generally result in faster zeolite crystallization, they can also increase the likelihood of framework defects and crystal intergrowths. In contrast, synthesis in neutral fluoride media tends to produce fewer defects because fluoride balances positive charges from structure-directing agents. However, this method often requires significantly longer crystallization times and involves the handling of dangerous HF. In the present study, we pursue the best of both synthesis conditions, rapid syntheses with controllable defect concentrations, by disentangling of mineralizing agent and chargebalancing agent using ammonium fluoride (NH 4 F) as an alternative to HF. We have investigated the use of NH 4 F in the syntheses of siliceous and aluminum-containing zeolite A (LTA, small pore), ZSM-5 (MFI, medium pore), and siliceous Beta(*BEA, large pore). The crystallization times of all four zeolites decreased substantially with an increasing NH 4 F concentration. Crystallization times were reduced from 24 to 4 h (Si-LTA), 96 to 36 h (Al-LTA), 240 to 6 h (ZSM-5), and 24 to 3 h (Si-*BEA). Additionally, increasing the NH 4 F concentration in the synthesis mixtures decreases the defect densities of siliceous zeolites. Raman spectroscopy, along with 29 Si MAS NMR, 19 F MAS NMR, 13 C MAS NMR, and fluorine elemental analysis of Si-LTA samples confirms that the reduction in charged defects (Si−O − ) is due to the higher incorporation of F − within the double four-membered ring (D4R) present in the LTA samples. We show that the accelerated crystallization is due to the role of F − in enhancing the silica mineralization rate (formation of silicon hexafluoride species) and stabilizing D4Rs under basic conditions. As a result, combining basic and fluoride-mediated synthesis could therefore be advantageous for faster zeolite production and improved control over structural properties for a wide variety of zeolite structures.

Anions

Arcjet cathode phenomena

Cathode tips made from a number of different materials were tested in a modular arcjet thruster in order to examine cathode phenomena. Periodic disassembly and examination, along with the data collected during testing, indicated that all of the tungsten-based materials behaved similarly despite the fact that in one of these samples the percentage of thorium oxide was doubled and another was 25 percent rhenium. The mass loss rate from a 2 percent thoriated rhenium cathode was found to be an order of magnitude greater than that observed using 2 percent thoriated tungsten. Detailed analysis of one of these cathode tips showed that the molten crater contained pure tungsten to a depth of about 150 microns. Problems with thermal stress cracking were encountered in the testing of a hafnium carbide tip. Post test analysis showed that the active area of the tip had chemically reacted with the propellant. A 100 hour continuous test was run at about 1 kW. Post test analysis revealed no dendrite formation, such as observed in a 30 kW arcjet lifetest, near the cathode crater. The cathodes from both this test and a previously run 1000 hour cycled test displayed nearly identical arc craters. Data and calculations indicate that the mass losses observed in testing can be explained by evaporation.

Curran, Francis M.

Arcjet Cathode Phenomena

Cathode tips made from a number of different materials were tested in a modular arcjet thruster in order to examine cathode phenomena. Periodic disassembly and examination, along with the data collected during testing, indicated that all of the tungsten-based materials behaved similarly despite the fact that in one of these samples the percentage of thorium oxide was doubled and another was 25 percent rhenium. The mass loss rate from a 2 percent thoriated rhenium cathode was found to be an order of magnitude greater than that observed using 2 percent thoriated tungsten. Detailed analysis of one of these cathode tips showed that the molten crater contained pure tungsten to a depth of about 150 microns. Problems with thermal stress cracking were encountered in the testing of a hafnium carbide tip. Post test analysis showed that the active area of the tip had chemically reacted with the propellant. A 100 hour continuous test was run at about 1 kW. Post test analysis revealed no dendrite formation, such as observed in a 30 kW arcjet lifetest, near the cathode crater. The cathodes from both this test and a previously run 1000 hour cycled test displayed nearly identical arc craters. Data and calculations indicate that the mass losses observed in testing can be explained by evaporation.

Curran, Francis M.