Neutrino masses from low scale partial compositeness

We consider a class of models in which the neutrinos acquire Majorana masses through mixing with singlet neutrinos that emerge as composite states of a strongly coupled hidden sector. In this framework, the light neutrinos are partially composite particles that obtain their masses through the inverse seesaw mechanism. We focus on the scenario in which the strong dynamics is approximately conformal in the ultraviolet, and the compositeness scale lies at or below the weak scale. The small parameters in the Lagrangian necessary to realize the observed neutrino masses can naturally arise as a consequence of the scaling dimensions of operators in the conformal field theory. We show that this class of models has interesting implications for a wide variety of experiments, including colliders and beam dumps, searches for lepton flavor violation and neutrinoless double beta decay, and cosmological observations. At colliders and beam dumps, this scenario can give rise to striking signals involving multiple displaced vertices. The exchange of hidden sector states can lead to observable rates for flavor violating processes such as μ → eγ and μ → e conversion. If the compositeness scale lies at or below a hundred MeV, the rate for neutrinoless double beta decay is suppressed by form factors and may be reduced by an order of magnitude or more. The late decays of relic singlet neutrinos can give rise to spectral distortions in the cosmic microwave background that are large enough to be observed in future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($ββ0ν$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{ββ}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{ββ})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $ββ0ν$.

Pérez Maneiro, M. [Santiago de Compostela U., IGFA↗

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136Xe

Abstract The imaging of individual Ba 2+ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba 2+ ion imaging inside a high-pressure xenon gas environment. Ba 2+ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm 2 located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in 136 Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretable boosted-decision-tree analysis for the Majorana Demonstrator

The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Cornering (quasi) degenerate neutrinos with cosmology

In light of the improved sensitivities of cosmological observations, we examine the status of quasi-degenerate neutrino mass scenarios. Within the simplest extension of the standard cosmological model with massive neutrinos, we find that quasi-degenerate neutrinos are severely constrained by present cosmological data and neutrino oscillation experiments. We find that Planck 2018 observations of cosmic microwave background (CMB) anisotropies disfavour quasi-degenerate neutrino masses at 2.4 Gaussian >σ’s, while adding baryon acoustic oscillations (BAO) data brings the rejection to 5.9 σ’s. The highest statistical significance with which one would be able to rule out quasi-degeneracy would arise if the sum of neutrino masses is Σm v = 60 meV (the minimum allowed by neutrino oscillation experiments); indeed a sensitivity of 15 meV, as expected from a combination of future cosmological probes, would further improve the rejection level up to 17σ. We discuss the robustness of these projections with respect to assumptions on the underlying cosmological model, and also compare them with bounds from β decay endpoint and neutrinoless double beta decay studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The study of C-13(a, n)O-16 reactions in the Majorana Demonstrator calibration data

Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied 13C(a, n)1640 O reactions induced by a-particles emitted within the calibration sources of the Majorana Demonstrator. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129 keV ?-rays emitted from the excited 1643 O states that are populated when the incoming a-particles have enough energy. Thanks to the excellent energy performance of the Demonstrator’s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by Geant4 simulations, a comparison between the observed 6129 keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent with each other, albeit with large statistical uncertainties. This agreement provides supports for further background predictions for (a, n)-reactions in future double-beta decay search efforts.

6 ≤ A ≤ 19↗

Status and results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay [0$vββ$] of 130 Te. The detector consists of a segmented array of 988 natural TeO 2 cubic crystals arranged in a cylindrical compact structure of 19 towers. The detector construction was completed in August 2016 and data taking started in Spring 2017. Here, we present a brief description of the bolometric technique for rare events search and the CUORE detector, then we concentrate on the data analysis results. In this respect, we focus on the procedure for data processing and on the first 0$vββ$ results we obtained from a total TeO 2 exposure of 86.3 kg · yr. Next, we illustrate the main background sources and the CUORE background model, from which we obtain the most precise measurement of 130 Te 2$vββ$ half-life to date. Finally, we discuss the improvements achieved with 2018 and 2019 detector optimization campaigns and the current perspectives of our experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lowering the Energy Threshold of the CUORE Experiment: Benefits in the Surface Alpha Events Reconstruction

CUORE is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay of 130 Te. Thanks to its very low background and large mass, CUORE is also a powerful tool to study a broad class of phenomena, such as solar axions and WIMP scattering. The ability to conduct such sensitive searches crucially depends on the energy threshold, which has to be kept as low as possible. Here, we show how the trigger algorithm affects the sensitivity to low-energy phenomena and the interpretation of the energy spectrum. In particular, we focus on the impact that the trigger algorithm has on the identification of the coincidence events among different crystals and, consequently, on the reconstruction of the background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy calibration of germanium detectors for the Majorana Demonstrator

The Majorana Demonstrator was a search for neutrinoless double-beta decay (0νββ) in the 76 Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a 228 Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.

47 OTHER INSTRUMENTATION↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $ ^{136}\mathrm Xe$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83\text {m}}\textrm{Kr}$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83\text {m}}\textrm{Kr}$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta \beta }$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

Martínez-Lema, G. [Donostia Intl. Phys. Ctr., San ↗

Sensitivity of the CUPID experiment to $0\nu \beta \beta$ decay of 100 Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu \beta \beta$ ) of 100 Mo using Li 2 MoO 4 scintillating crystals. It will operate 1596 crystals at ~10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for α rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu \beta \beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of 1.0 x 10 –4 counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \textrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta \beta } < \ 9.6$ – 28 meV. The Frequentist discovery sensitivity (3σ ) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \textrm{yr}$, corresponding to $\hat{m}_{\beta \beta }= \ 12$ – 36 meV.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Effective field theories for collective excitations of atomic nuclei

Collective modes emerge as the relevant degrees of freedom that govern low-energy excitations of atomic nuclei. These modes—rotations, pairing rotations, and vibrations—are separated in energy from non-collective excitations, making it possible to describe them in the framework of effective field theory. Rotations and pairing rotations are the remnants of Nambu–Goldstone modes from the emergent breaking of rotational symmetry and phase symmetries in finite deformed and finite superfluid nuclei, respectively. The symmetry breaking severely constrains the structure of low-energy Lagrangians and thereby clarifies what is essential and simplifies the description. The approach via effective field theories exposes the essence of nuclear collective excitations and is defined with a breakdown scale in mind. This permits one to make systematic improvements and to estimate and quantify uncertainties. Effective field theories of collective excitations have been used to compute spectra, transition rates, and other matrix elements of interest. In particular, predictions of the nuclear matrix element for neutrinoless double beta decay then come with quantified uncertainties. This review summarizes these results and also compares the approach via effective field theories to well-known models and ab initio computations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large-scale, precision xenon doping of liquid argon

The detection of scintillation light from liquid argon is an experimental technique key to a number of current and future nuclear/particle physics experiments, such as neutrino physics, neutrinoless double beta decay and dark matter searches. Additionally, although the idea of adding small quantities of xenon (doping) to enhance the light yield has attracted considerable interest, this technique has never been demonstrated at the necessary scale or precision. Here we report on xenon doping in a 100 l cryogenic vessel. Xenon doping was performed in four concentrations of 1.00 ± 0.06 ppm, 2.0 ± 0.1 ppm, 5.0 ± 0.3 ppm, and 10.0 ± 0.5 ppm. These measurements represent the most precise xenon doping measurements as of publishing. We observed an increase in average light yield by a factor of 1.92 ± 0.12(syst) ± 0.02(stat) at a dopant concentration of 10 ppm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗