Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dose assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Assessment of Tools for Molten Salt Reactor Dose Rate Calculations

This report discusses a preliminary assessment of the capabilities of current state-of-the-art stochastic codes Shift and MCNP6 to calculate the ex-core radiation dose rates for a simplified Molten Salt Reactor (MSR) model. The Monte Carlo code Shift has been under significant development in recent years at ORNL as part of the CASL program and is now supported by NEAMS. Originally, Shift was developed for LWR ex-core calculations but with dose rate and shielding calculations specifically requested by the NEAMS program’s MSR industry partners, the MSR Application Drivers team was tasked with assessing Shift for non-LWR applications. This was the first application of the Shift code for non-LWRs and the findings can be considered preliminary due to the activities occurring only over a 5-month period. Attractive features of Shift include massive parallelization and advanced automated variance reduction techniques such as CADIS and FW-CADIS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High LET, passive space radiation dosimetry and spectrometry

The development of high linear energy transfer (LET), passive radiation dosimetry and spectrometry is needed for the purpose of accurate determination of equivalent doses and assessment of health risks to astronauts on long duration missions. Progress in the following research areas is summerized: intercomparisons of cosmic ray equivalent dose and LET spectra measurements between STS missions and between astronauts; increases LET spectra measurement accuracy with ATAS; space radiation measurements for intercomparisons of passive (PNTD, TLD, TRND, Emulsion) and active (TEPC, RME-111) dosimeters; interaction of cosmic ray particles with nuclei in matter; radiation measurements after long duration space exposures; ground based dosimeter calibrations; neutron detector calibrations; radiation measurements on Soviet/Russian spacecraft; space radiation measurements under thin shielding; and space radiation.

Benton, E. V.↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Biomathematical Model of Lymphopoiesis and Its Application to Acute and Chronic Irradiation Assessment

After the events of September 11, 2001, there is an increasing concern of the occurrence of radiological terrorism that may result in significant casualties in densely populated areas. Much effort has been made to establish various biomarkers to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios, which are demanded for effective medical management and treatment of the exposed victims. Among these the count of lymphocytes in peripheral blood and their depletion kinetics are the most important early indicators of the severity of the radiation injury. In this study, we examine a biomathematical model of lymphopoiesis which has been successfully utilized to simulate and interpret experimental data of acute and chronic irradiations on rodents [1]. With revised parameters for humans, we find this model can reproduce several sets of clinical lymphocyte data of accident victims over a wide range of absorbed doses. In addition, the absolute lymphocyte counts and the depletion rate constants calculated by this model also show good correlation with the Guskova formula and the Goans model, the two empirical tools which have been widely recognized for early estimation of the exposed dose after radiation accidents [2]. We also use the model to analyze the hematological data of the Techa River residents which were exposed to chronic low-dose irradiation during 1950-1956 [3]. This model can serve as a computational tool in radiation accident management, military operations involving nuclear warfare, radiation therapy, and space radiation risk assessment.

Hu, Shaowen↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2024

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2024. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2024 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

54 ENVIRONMENTAL SCIENCES↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2025

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2025. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of the DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, the evaluation of data collected in 2025 continued to indicate that WVDP activities posed no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of the Risk of Radiation-Associated Circulatory and Cancer Disease Mortality in a NASA Early Astronaut Cohort

Of the many possible health challenges posed during extended exploratory missions to space, the effects of space radiation on cardiovascular disease and cancer are of particular concern. There are unique challenges to estimating those radiation risks; care and appropriate and rigorous methodology should be applied when considering small cohorts such as the NASA astronaut population. The objective of this work was to determine if there was sufficient evidence for excess risk of cardiovascular disease and cancer in early NASA astronaut cohorts. NASA astronauts in selection groups 1-7 were chosen; this relatively homogeneous cohort consists of 73 white males, who unlike today's astronauts, maintained similar smoking and drinking habits to the general US population, and have published radiation doses. The participants flew in space on missions Mercury through Shuttle and received space radiation doses between 0-74.1 milligrays. Cause of death information was obtained from the Lifetime Surveillance of Astronaut Health (LSAH) program at NASA Johnson Space Center. Mortality was compared with the US male population. Trends of mortality with dose were assessed using a logistic model, fitted by maximum likelihood. Only 32 (43.84 percent) of the 73 early astronauts have died. Standard mortality ratios (SMRs) for cancer (n=7, SMR=43.4, 95 percent CI 17.8, 84.9), all circulatory disease (n=7, SMR=33.2, 95 percent CI 13.7, 65.0), and ischemic heart disease (IHD) (n=5, SMR=40.1, 95 percent CI 13.2, 89.4) were significantly lower than for the US white male population. For cerebrovascular disease, the upper confidence interval for SMR included 100, indicating it was not significantly different from the US population (n=2, SMR = 77.0, 95 percent CI 9.4, 268.2). The power of the study is low and remains below 10 percent even when risks 10 times those reported in the literature are assumed. Due to small sample size, there is currently insufficient statistical power to evaluate space radiation exposure effects on mortality in NASA astronauts. In addition to a comprehensive longitudinal study of NASA astronauts, a research strategy of low dose epidemiology data integration with cell and animal studies should be utilized for space radiation risk assessment in the astronauts.

Elgart, S. R.↗

Radiological Dose Consequence Modeling Parameters for Reactor and Nonreactor Nuclear Facilities

To assure consistency between DOE and NRC safety basis requirements this ECAR documents the DOE basis requirements for dose consequence assessments in accordance with Standard DOE-STD-3009-2014. The methodology in this ECAR outlines parameters for evaluating airborne radiological releases and provides a consistent basis for assessing current and future DOE NE facilities.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative Assessment of Radiological Consequences from Sabotage-Induced Releases in Diverse Microreactor Designs

Many microreactor design developers are planning to reduce on-site physical protection measures and emergency planning zones by relying on robust fuel and reactor designs and leveraging passive safety systems. These reductions raise the risk of sabotage at these microreactors. To evaluate these requirements, this study assessed the radiological consequences of sabotage-induced accidents at microreactors. For the assessment, five diverse designs, each producing 30 MWt, were considered. These designs included pressurized water microreactors (PWMs), sodium-cooled fast microreactors (SFMs), high-temperature helium-cooled prismatic microreactors (HTPMs), heat pipe–cooled microreactors (HPMs), and molten salt–cooled microreactors (MSMs). For each design, two postulated sabotage-induced accidents were defined along with the associated release percentages of fission products. Additionally, consequences from the release of activation products were assessed. With regard to evaluating physical protection and emergency planning requirements, the consequences of sabotage-induced accidents for each design type were found to be comparable. The differences were primarily because of the distinct fuel forms (and associated release mechanisms), burnup, and neutron spectra of the different microreactor types. Future effort will further investigate the release percentages of fission products to perform accurate dose consequence assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainty Analysis of Consequence Management Data Products

An interlaboratory effort has developed a probabilistic framework to characterize uncertainty in data products that are developed by the US Department of Energy Consequence Management Program in support of the Federal Radiological Monitoring and Assessment Center. The purpose of this paper is to provide an overview of the probability distributions of input variables and the statistical methods used to propagate and quantify the overall uncertainty of the derived response levels that are used as contours on data products due to the uncertainty in input parameters. Uncertainty analysis results are also presented for several study scenarios. This paper includes an example data product to illustrate the potential real-world implications of incorporating uncertainty analysis results into data products that inform protective action decisions. Data product contours that indicate areas where public protection actions may be warranted can be customized to an acceptable level of uncertainty. Finally, the investigators seek feedback from decision makers and the radiological emergency response community to determine how uncertainty information can be used to support the protective action decision-making process and how it can be presented on data products.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mechanism of Vapor-Phase Infiltration of Organometallic Hf in Poly(Methyl Methacrylate) for Hybrid Resist Applications

Inorganic–organic hybrid thin films synthesized by vapor-phase infiltration (VPI) of metal oxides into organic photoresists, such as poly(methyl methacrylate) (PMMA), have recently demonstrated their utility in extreme ultraviolet lithography, critical for angstrom-era semiconductor device miniaturization. Hafnium oxide infiltration has been reported recently for this purpose, but its detailed VPI mechanism has remained largely unexplored. In this study, we investigated the VPI characteristics and mechanisms of tetrakis(dimethylamido)hafnium (TDMAHf)─the hafnium precursor predominantly used for VPI in the field─into PMMA and examined its impact on electron-beam lithography (EBL) exposure behavior. VPI was performed at temperatures ranging from 85 to 150 °C, with chemical interactions characterized using infrared reflection-absorption spectroscopy, and resist patterning performance was evaluated through EBL dose-sensitivity assessments. The results indicate that TDMAHf forms a reversible adduct with PMMA at temperatures up to 120 °C, whereas at 150 °C, covalent bond formation occurs, most likely via dealkylation that leads to acetate formation. EBL studies reveal that resist sensitivity is influenced by both infiltration temperature and developer selection, with aqueous isopropyl alcohol development demonstrating enhanced sensitivity compared to organic solvent-based development. The optimized infiltration protocol at 120 °C ensures a uniform inorganic distribution without compromising resist dissolution. These findings not only help refine hybrid resist patterning performance but also offer insights potentially applicable to the VPI of other homoleptic metal-amide organometallic VPI precursors that include TDMA ligands.

36 MATERIALS SCIENCE↗

Methods to Account for CAP-88 PC-Omitted Nuclides in Radioactive Air Emissions From DOE Facilities

Routine research and development activities at US Department of Energy facilities can result in the release of radioactive emissions, potentially exposing the public and the environment. Such emissions are subject to certain Clean Air Act regulations, specifically those outlined in 40 CFR Part 61, Subpart H, which are enforced by the US Environmental Protection Agency. Compliance is determined in part with a dose standard. Doses to members of the public from most US Department of Energy facility airborne emissions are modeled using CAP-88 PC software, the latest version of which contains more than 1,200 radionuclides. Radioactive effluents from US Department of Energy facilities may contain radioisotopes that are not available in CAP-88 PC, and those radioisotopes must still be evaluated to determine whether doses to members of the public are below established limits. CAP-88 PC-omitted radionuclides can be accounted for using alternate methods, including the use of surrogate radionuclides. Here, this paper elucidates the process of accounting for CAP-88 PC-omitted radionuclides by providing criteria and rationale for surrogate selection, a compilation of surrogate radionuclides used in the past by US Department of Energy facilities, a discussion of alternate methods used to account for CAP-88 PC-omitted radionuclides and a comparison of methods and impacts on receptor doses. Ultimately, this paper aims to aid in the process of surrogate selection and consequently to simplify and expedite compliance with Clean Air Act regulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Conversion of Site-Specific Meteorological Data for use in CAP-88 PC

CAP-88 PC is a commonly used radiological atmospheric dispersion model. This US EPA-approved model is used to demonstrate compliance with atmospheric emission regulations for radionuclides. While the model includes a large library of meteorological data for use across the United States, there are applications when users may wish to use onsite meteorological data as an input to the CAP-88 PC model. Here, in this work, we present a work-around process for preparing and converting onsite data for use in CAP-88 PC. However, the use of local data should provide a more realistic estimate of doses to members of the public in the immediate vicinity of a facility, although the regulatory agency having jurisdiction may not accept the use of local data for compliance. Additionally, the historical meteorological records from 20+ years ago (at a site many kilometers away) might not be representative of current local weather patterns, highlighting another benefit of using local meteorological data.

54 ENVIRONMENTAL SCIENCES↗

Triso Analysis Tool For Predictive Source Terms

Source term modeling for TRi-structural ISOtropic (TRISO) fuel has been performed for previous reactor designs, but few are available in the open literature. Thus, there is a need to develop a simple, versatile, and mechanistic model of fission product release and transport in gas reactor cores that can be applied to a variety of reactors through user inputs and reactor-specific radionuclide inventories. To meet this need, the TRISO Analysis Tool for Predictive Source terms (TRISO-ATOPS) was developed. This model calculates the release of the key safety-important fission products by diffusion through the kernel, silicon carbide and graphite based on fuel and graphite temperatures in the reactor under normal operation. These releases from the fuel enter the coolant where they can plate-out on cooler surfaces. A clean-up model is included for designs with a coolant purification system for removing fission gases. This initial distribution of fission products in the reactor serves as an initial condition for potential releases under postulated accident conditions. From this initial condition, the model calculates the fission product release for any transient temperature profile, and the fission product releases can then be used to assess radiological dose to the workers and the public using conventional radiological dose tools. Data on the diffusion of fission products is based on historic German TRISO experiments and the more current Department of Energy Advanced Gas Reactor TRISO fuel development program. The example cases in this work demonstrate the flexibility of the model

Stoyer, Benjamin [Idaho National Laboratory (INL),↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2020. Final Report

The U.S. Department of Energy requires that all its site facilities develop an annual site environmental report to comply with DOE Order 231.1B, Chg 1, and DOE Order 458.1, Admin Chg 4. This report provides a synopsis of calendar year 2020 information related to environmental management performance and compliance efforts at Pacific Northwest National Laboratory. It summarizes site compliance with federal, state, and local environmental laws, regulations, policies, directives, permits, and Orders, and provides environmental management performance benchmarks and their status to the public, regulatory agencies, community officials, Native American tribes, and public interest groups.

54 ENVIRONMENTAL SCIENCES↗

User’s Manual for RESRAD-BUILD Code V.4: Vol. 1 – Methodology and Models Used in RESRAD-BUILD Code

The RESRAD-BUILD computer code models radionuclide release and transport in indoor environments and performs pathway analyses to evaluate the potential radiological dose and risk incurred by an individual who works or lives in a building contaminated with radioactive material or housing radioactively contaminated furniture or equipment. The code provides four geometries to characterize a radiation source: point, line, area, and volume, in which radionuclides are homogeneously distributed. Radionuclides contained in a source are considered to be released to the indoor air due to various processes including erosion (mechanically or weathering), diffusion (for tritium and radon in a volume source), or emanation (radon in a point, line, or area source). The release can proceed through different time phases with different rates. In RESRAD-BUILD Version 4.0, a dynamic ventilation model is implemented to simulate the fate and transport of source material particles and radionuclides after their releases. This dynamic ventilation model considers (1) air exchange between rooms in the building and between the rooms and the outdoor environment, (2) deposition from air to floor, (3) resuspension from the floor to the air, and (4) periodical vacuuming that reduces the floor deposition. The fate and transport modeling provides estimates of radionuclide concentrations in the source, in the air, and on the floor at different times, which are then integrated over the exposure duration for the calculation of radiation doses and cancer risks. A single run of the RESRAD-BUILD code can model a building with up to 9 rooms, 10 sources, and 10 receptors. The potential radiation dose and cancer risk incurred by each receptor are calculated for seven exposure pathways: (1) external radiation directly from the sources (accounting for shielding), (2) external radiation from radioactive particles deposited on the floors, (3) external radiation from airborne radionuclides, (4) inhalation of airborne radionuclides, (5) inhalation of radon and radon progenies, (6) inadvertent ingestion of radioactive particles directly from the source, and (7) ingestion of radioactive particles deposited on the floors. Various exposure scenarios can be modeled with RESRAD-BUILD, including but are not limited to, office worker, renovation worker, decontamination worker, building visitor, and resident. Both deterministic and probabilistic analyses can be performed to obtain results in both text reports and graphic displays.

61 RADIATION PROTECTION AND DOSIMETRY↗