At least 127 records · Page 7

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring for Superhot Geothermal Targets in Magmatic Settings: 2022 Field Campaign at Newberry Volcano

This paper presents preliminary results from a subset of work carried out as part of a multinational research project entitled DErisking Exploration for multiple geothermal Plays in magmatic ENvironments (DEEPEN), supported by the U.S. Department of Energy (DOE) and Geothermica, a joint effort by EU member states and associated countries. The DEEPEN project will develop a customized approach to exploration for supercritical and superhot geothermal plays in magmatic systems, which will be applied to two demonstration sites. This paper summarizes field activities carried out at the U.S. demonstration site, Newberry Volcano in central Oregon. The objective of this work effort is to refine the subsurface model of Newberry Volcano, with special focus on deeper zones including the magmatic plumbing system and other key geologic elements. New data collection included gravity and wideband magnetotelluric (MT) surveys, as well as reinstallation of a seismic network. The National Renewable Energy Laboratory (NREL) and Enthalpion Energy LLC (Enthalpion) worked with the Deschutes National Forest Fort Rock District to use a low ground disturbance method of MT deployment to collect MT data inside the caldera and other restricted areas inside the National Volcanic Monument. This opened these areas to geophysical exploration for the first time in decades. Sites along and adjacent to the south rim of the volcano constituted the primary survey objectives. A team from Lawrence Berkeley National Laboratory (LBNL), the U.S. Geological Survey (USGS), and AltaRock also began the process of reinstalling the seismic network from the AltaRock enhanced geothermal system (EGS) demonstration in anticipation of further development activities at the site. The data ingestion, reduction, and analysis phase of the project is ongoing. We are currently processing the MT and gravity data and are developing a new, highly GPU-accelerated, 3D joint MT and gravity inversion to better localize the south rim/south flank conductive target and better understand its relationship to deep heat, fluid sources, and surface extrusive features. Joint inversions, which have not yet been undertaken at Newberry, will allow us to obtain constraints on the geologic model that cannot be determined from each method in isolation, improving our ability to image key geologic features at depth.

geophysics↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Response to Community-Scale Geothermal Energy Production

Geothermal heat, as renewable energy, shows great advantage with respect to its environmental impact due to its significantly lower CO2 emissions than conventional fossil fuel. Open and closed-loop geothermal heat pumps, which utilize shallow geothermal systems, are an efficient technology for cooling and heating buildings, especially in urban areas. Integrated use of geothermal energy technologies for district heating, cooling, and thermal energy storage can be applied to optimize the subsurface for communities to provide them with multiple sustainable energy and community resilience benefits. The utilization of the subsurface resources may lead to a variation in the underground environment, which might further impact local environmental conditions. However, very few simulators can handle such a highly complex set of coupled computations on a regional or city scale. We have developed high-performance computing (HPC) based hydrothermal finite element (FE) simulator that can simulate the subsurface and its hydrothermal conditions at a scale of tens of km. The HPC simulator enables us to investigate the subsurface thermal and hydrologic response to the built underground environment (such as basements and subways) at the community scale. In this study, a coupled hydrothermal simulator is developed based on the open-source finite element library deal.II. The HPC simulator was validated by comparing the results of a benchmark case study against COMSOL Multiphysics, in which Aquifer Thermal Energy Storage (ATES) is modeled and a process of heat injection into ATES is simulated. The use of an energy pile system at the Treasure Island redevelopment site (San Francisco, CA, USA) was selected as a case study to demonstrate the HPC capability of the developed simulator. The simulator is capable of modeling multiple city-scale geothermal scenarios in a reasonable amount of time.

Sun, Xiang↗

Advances on CHP District Energy and Microgrids Deployment: Simplified Tool for Rapidly Deploying Feasibility Analytics for the Non-Technical User (Final Technical Report)

Community energy systems have proven to have the potential to improve cost efficiency, resilience, and decarbonize. However, investing in community energy systems such as community microgrids or district energy systems is a complex decision due to the high initial investment and the uncertainties associated with the long development time and lifecycle of the project. Tools that make feasibility assessments accessible to non-technical users like investors, policymakers, and other stakeholders will result in more feasibility analyses completed, more candidate projects identified, and more community energy systems deployed. The pilot tool developed under this award is named Energy Fellow. Energy Fellow allows technical and non-technical users to complete feasibility analyses for district energy systems and community microgrids. This is the first software tool of its kind designed for non-technical users and available at no cost. Its scope was adjusted to a 25x25-mile region within the Houston area in Texas to make its development compatible with the funding available. However, the findings and models developed make this pilot tool easily scalable to the US. The lessons learned during the design, implementation, and testing stages have helped find trade-off solutions to software and hardware challenges related to implementing 3D models in online tools. Green software strategies has been successfully applied to the design and operations of the tool, and the team has researched the aspects of the (non-technical) user experience that will make commercial developments of this tool even more impactful.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic Design Optimization for Fast Reactors. Part II: Impact of Technoeconomic Constraints on Optimal Design

There is a current drive toward optimizing reactors, particularly small/micro reactors to minimize cost and maximize performance. Previous work has investigated the development of technoeconomic workflows for the design optimization of pool-type fast reactors that aim to deploy into district energy grids. Initial scoping studies verified that the workflow was capable of capturing design trends throughout a variety of design configurations and problem formulations while remaining sufficiently flexible. In this paper, this methodology is applied to understand how cost functions and technoeconomic constraints can drive optimal reactor design. Specifically, the UPu10Zr-fueled fast reactor model from Part I is adapted to include changes in the fissile content limits, control rod worth limits, control rod drive cost, and assumed fuel form. In the case of constraint relaxation at fixed power (fissile content and control rod worth limits), cost sensitivities of 5% to 10% were uncovered. Multi-objective optimization at varying reactor power levels with individualized control rod drives for each assembly (as opposed to one operational and one safety drive) increased cost by $\$10$ to $\$25$ million and substantially altered the optimal core geometry, favoring geometries with substantially fewer control rod placements relative to baseline optimization. Finally, a multi-objective optimization was performed at varying power levels with the fuel form overhauled to metallic, high-assay low-enriched uranium–based U10Zr with more refined fuel cost models. In the case of uranium fueling, the costs increased by at least $50 million relative to the baseline case. Furthermore, economic fuel zoning and lower reactivity swing cores were recovered. Each case serves to demonstrate the value of applying technoeconomic workflows to initial reactor design scoping studies to better understand the trade-off for a proposed concept between different design options.

Argonne Reactor Computation (ARC) codes↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The evolving role of geothermal energy for decarbonizing the United States

Geothermal energy is often referred to as a niche technology that is too localized, too small or too expensive to make much of a difference in how renewable energy will be supplied in a fully decarbonized future. As a result, geothermal energy has been undervalued in terms of what it could provide to complement, rather than compete with, electricity generation from wind, solar photovoltaic, concentrating solar power and other renewables. Geothermal energy systems are fully dispatchable and can provide baseload or load-following electric power or heat suitable for a wide range of applications including supplying district heating for communities and cities, and heating and cooling of individual buildings. The focus of our study is on the potential of utilizing geothermal energy for providing heat for buildings and industry at lower temperatures, a substitute for the combustion of fossil fuels. Because heating represents about 20% (20 EJ per year) of the annual primary energy consumption in the U.S.—with most of it coming from burning natural gas, oil and/or propane in furnaces—deploying geothermal heating on a national scale could have a significant impact on lowering carbon emissions. In heating-dominated states in the U.S. Northern Tier, heating often is among the largest contributors to the state's carbon footprint. This review begins with a discussion of the motivation and rationale behind considering geothermal as a key low-carbon heating option for the U.S. The study summarizes the U.S. geothermal resource and describes the applications and main engineering components of using geothermal energy for heating and cooling, electric power generation, and co-generation using district heating, geothermal heat pumps, and power conversion with steam flashing and organic Rankine plants. Environmental benefits and impacts are described. An extensive discussion of geologic and thermal-hydraulic aspects of the subsurface is included in the review because of their critical role in determining reservoir designs at specific sites to ensure sufficient productivity that is both safe and economically viable. Models for estimating levelized costs of district heating are used to show how costs are affected by reservoir performance, infrastructure capital costs, and financial parameters. Here, the review concludes with an assessment of technical subsurface issues associated with reservoir performance and the economic requirements for providing geothermal heating in district heating systems at a sufficient scale to have an impact on decarbonizing the U.S.

15 GEOTHERMAL ENERGY↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pathways for decarbonization of the buildings sector in Ukraine

The paper focuses on Ukraine’s intention to achieve a two-thirds reduction in buildings’ energy consumption for heating and cooling by 2050, concurrently aiming for net zero greenhouse gas emissions and heightened energy security. Here, the study examines the outcomes of retrofitting existing residential, commercial, and public buildings with highly efficient materials, improving construction standards, and transitioning to advanced heating systems. However, Russia’s invasion in 2022 inflicted substantial damage, prompting a shift from retrofit and decarbonization to reconstruction. The Ukrainian government’s Reconstruction Plan emphasizes clean, sustainable, and resilient energy systems. The study employs energy system and integrated assessment models (TIMES-Ukraine and GCAM-Ukraine) to explore scenarios taking into consideration the war, reconstruction, and a net zero CO 2 pathway. Using two models allowed the inter-model comparison. The analysis addresses vital questions on energy resiliency measures and the compounding effects of decarbonization. Findings indicate that Ukraine’s energy goals can be met through strategic retrofitting and economy-wide decarbonization, emphasizing the importance of low-carbon alternatives like district heating with renewable sources. Electrification with renewables and fuel-switching emerges as crucial for achieving building decarbonization. The study offers valuable insights into navigating energy challenges amidst the war and outlines a pathway for Ukraine’s sustainable energy future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Valuation of Novel Waste Heat Sources and a Path Towards Adoption: Preprint

It is recognized that beneficial electrification of most space heating will be necessary to avert the worst consequences of climate change. Fifth generation district heating and cooling (5GDHC) networks operate at near-ambient temperatures and thus facilitate heating electrification, as well as the use of waste heat sources at a wide range of temperatures. In this paper, we analyze the potential of waste heat to supply the required heat to these networks and describe the business models that could expand the use of these waste heat sources. Showcase single family and commercial districts in the US are discussed to demonstrate emerging technologies, district infrastructure approaches, and third-party thermal utility funding models for these leading 5GDHC networks. As part of this work, heat flow and temperature profiles from five different types of waste heat sources are analyzed. An example district is used to examine the integration potential and to quantify the potential reduction in energy consumption. The results indicate that 5GDHC networks are highly suitable systems for utilizing low to moderate temperature waste heat sources. In the studied district, waste heat can cover a share of up to 66% of the heat supplied to the ambient loop and reduce the overall electricity consumption for heating by up to 51%, depending on the characteristics of the specific power, temperature, and type of waste heat source. Through their moderate operating temperatures and use of waste heat sources combined with third party financed infrastructure, 5GDHC districts have significant potential to reduce carbon emissions associated with space conditioning.

district energy↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING↗

BioSiting Tool (BioSiting) v2

The BioSiting Tool provides a geospatial interface for analyzing bioeconomy resources and infrastructure across the continental U.S. The tool integrates empirical and modeled data from a broad range of sources. Bioeconomy resources mapped in the tool include agricultural residues, forest residues, municipal solid waste streams, food waste, manure, fats, oils and greases and potential yields of energy crops. Infrastructure mapped in the tool includes biorefineries, material recovery facilities, anaerobic digesters, wastewater treatment plants, combustion plants, district energy systems, crude oil pipelines, petroleum pipelines, natural gas pipelines, railways and freight terminals. Additional data layers include environmental justice indicators at the census tract level and carbon dioxide geologic storage potential. Users can select a location on the map, define a buffer radius in kilometers and generate an inventory of all bioecomony resources within the buffer zone. Data from the tool can be downloaded from individual buffer zones, or at the state or national level.

Huntington, Tyler↗

State-Level Trends in Renewable Energy Procurement via Solar Installation versus Green Electricity

In recent years, options for procuring renewable energy have increased, ranging from rooftop solar installation to utility green pricing to Community Choice Aggregation. These options vary in terms of costs and benefits to the consumer as well as grid integration implications. However, little is known regarding how the presence of a wide range of voluntary utility-scale renewable procurement options as well as their growth could affect adoption of distributed residential solar. To examine this relationship, we fit a two-stage least squares random effects regression model on panel data from 2016 to 2019 for all fifty US states plus the District of Columbia, controlling for variables that measure state-level policies, economic factors, and resource availability. Although there was no evidence of a strong relationship between demand for utility-scale and distributed options across all states, the state-level correlations suggest a wide variation between states including a positive, zero or negative relationship between utility-scale and distributed generation.

consumer demand↗

Efficient Computation Of Surface Sunlit Fractions In Urban-Scale Building Modeling Using Ray-Tracing Techniques

For building energy simulation at an urban-scale, solar shading calculations can be significantly slow when a large number of shading surfaces are considered in the solar shading calculations, due to the computational complexity of the geometry calculations. We developed a new algorithm using the ray-tracing technique to pre-calculate the sunlit fractions of all exterior surfaces in an urban district altogether. The ray tracing-based calculator is accelerated using General Purpose Graphics Processing Units (GPGPUs) and the Optix ray tracing library, and provides an efficient, flexible, and robust means for computing the sunlit fraction of large numbers of urban surfaces of complex geometries.

Luo, Xuan↗