Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution system monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

DIMPLES: Distributed Influence Maximization for Pandemic pLanning on Exascale Systems

We study exascale parallel algorithms for the selection of intervention or monitoring strategies in massive realistic socio-technical networks through scalable Influence Maximization (InfMax) algorithms. We employ novel techniques to enable efficient scaling on up to 8k nodes of OLCF Frontier, with 65k AMD GPUs and 458k AMD CPU cores. Current state-of-the-art InfMax tools are limited to networks with only a few million actors (vertices) and a few hundred million interactions (edges). By overcoming these limitations, we show that our approach is capable of processing a realistic social contact network of the United States with 285 million nodes and about 8 billion edges. This two orders-of-magnitude improvement over the previous state-of-the-art is obtained by leveraging algorithmic advancements for the InfMax problem and designing several problem-specific approaches to overlap communication with computation, improve GPU efficiency, and lower the application’s memory requirements. We evaluate strong scaling for computing 10k most influential seeds using up to 8k nodes of an exascale system, and weak scaling from 128 to 8k system nodes for seed sets ranging from 625 to 40k seeds. We achieve the fastest-known runtime of 25 minutes while performing 48 million diffusion simulations totaling 2.31 petabytes to identify 40k influential seeds using 8k nodes, and take 5.75 minutes to identify 10k seeds while using 4k nodes.

Minutoli, Marco [Pacific Northwest National Labora↗

Entropy of the Quantum–Classical Interface: A Potential Metric for Security

Hybrid quantum–classical systems are emerging as key platforms in quantum computing, sensing, and communication technologies, but the quantum–classical interface (QCI)—the boundary enabling these systems—introduces unique and largely unexplored security vulnerabilities. This position paper proposes using entropy-based metrics to monitor and enhance security, specifically at the QCI. We present a theoretical security outline that leverages well-established information-theoretic entropy measures, such as Shannon entropy, von Neumann entropy, and quantum relative entropy, to detect anomalous behaviors and potential breaches at the QCI. By linking entropy fluctuations to scenarios of practical relevance—including quantum key distribution, quantum sensing, and hybrid control systems—we promote the potential value and applicability of entropy-based security monitoring. While explicitly acknowledging practical limitations and theoretical assumptions, we argue that entropy-based metrics provide a complementary approach to existing security methods, inviting further empirical studies and theoretical refinements that can strengthen future quantum technologies.

97 MATHEMATICS AND COMPUTING↗

Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration

Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.

Distributed Strain Sensing↗

Engineering Privacy at the Edge: A Practical Guide to Differential Privacy in System Architectures

The rapid expansion of distributed and edge computing platforms—spanning autonomous vehicles, IoT sensors, and healthcare monitors—has heightened concerns about data privacy. Differential Privacy (DP) offers a rigorous mathematical framework to protect sensitive information while retaining analytical utility. This tutorial introduces the foundations of DP for both numerical and categorical datasets and extends the discussion to correlation-aware techniques tailored for structured and high-dimensional data. Hands-on demonstrations will begin with the PETINA (Privacy prEservaTIoN Algorithms) package for numerical data and continue with MIC-DP (Maximum Information Correlated Differential Privacy) for tabular data. Designed for researchers and practitioners in secure systems, embedded architectures, and AI accelerators, the tutorial emphasizes practical and scalable methods for integrating DP into real-world system designs.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

A low-cost centralized HVAC control system solution for energy savings, load shedding, and improved maintenance

University campuses rely on centralized controls for managing and optimizing complex HVAC systems in larger buildings. However, most campuses also have many smaller buildings with packaged HVAC systems controlled by a stand-alone thermostat. Even when these distributed and often overlooked systems have modern programmable thermostats, they cannot be centrally monitored or controlled, and they are typically not programmed adequately. This paper describes the implementation of a low-cost centralized control solution for these systems serving smaller campus buildings, mostly under 5,000 sf and representative of light commercial spaces. Thanks to advances in technology spurred by residential and commercial IoT developments, simple networked thermostat solutions exist that can easily replace original thermostats, and, connect these systems to a web-based portal for monitoring and control. We show that, with small customizations, these platforms can be integrated into facility management workflows. Beyond the energy savings potential from improved scheduling and closer management of these systems, there are significant advantages for maintenance crews since these systems can now be monitored on smart phones or tablets. A grid-responsive load-shedding program has also been implemented for additional cost savings. The networked thermostats can also be connected to additional systems such as economizer controls for improved ventilation management and energy savings. With data from these systems integrated centrally, it can also be used for improved analytics and fault detection. A toolkit has been developed to share the program with other campuses, whether for energy savings, improved management of ventilation, or a more proactive maintenance approach.

Fauchier-Magnan, Nicolas↗

A Framework to Demonstrate a DNP3 Interface With a CIM-Based Data Integration Platform: Preprint

The contemporary electrical grid is characterized by its complexity and abundance of data. A control-rich environment supported by information and communication technologies within an Advanced Distribution Management System (ADMS) presents a viable and cost-effective option for utility companies aiming to implement advanced real-time analytical schemes for monitoring and remotely controlling distribution feeders. Modular platform-based approaches to distribution operations require a structured framework for acquiring field device measurements, performing analytics, converting the setpoint to the correct protocol, and sending it on the appropriate communications network to the field devices. We present the development and deployment of an application service to integrate an open-source standardsbased platform with an ADMS test bed with field devices using the Distributed Network Protocol (DNP3) for data exchange. The step-by-step procedure for establishing the DNP3-Master service on an open-source distribution platform is outlined, comprehensively explaining the Master setup process. Moreover, sample use case results highlight the capabilities of the DNP3- Master service setup. Results demonstrate the scalability and configurability of the DNP3-Master service, making it adaptable for integration with other relevant applications, thus providing potential opportunities for real-world field trials and real-time assessments.

ADMS↗

Digital Twin Applications in the Water Sector: A Review

As cities develop and resource demands rise, the water sector faces crucial challenges to deliver reliable, sustainable, and efficient services. Digital Twins (DTs), virtual replicas of physical systems, offer a promising tool to transform how we manage water infrastructure. Originally developed in the aerospace industry, DTs are now gaining traction in the water sector, enabling real-time monitoring, simulation, and predictive control of water and wastewater treatment, collection and distribution networks, and water reclamation and reuse systems. While still emerging in the water sector, DTs have shown potential to enhance operational efficiency, reduce environmental impacts, and support smarter, more resilient water management. This review study provides a comprehensive overview of current DT applications in the water sector, highlighting successful case studies, technical challenges, and knowledge gaps. It also explores how DTs can help bridge the water–energy nexus by optimizing resources utilized across interconnected systems. By synthesizing recent advances and identifying future research directions, this paper illustrates how DTs can play a central role in building sustainable, adaptive, and digitally-enabled water infrastructure.

digital twin↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Southwest Wind Power R&D Test Site Development at the National Wind Technology Center (CRADA CRD-12-00472 Final Report)

Southwest Windpower, Inc. (SWWP) has been designing and distributing small wind turbines for more than 22 years and is the recognized global leader in the design, manufacturing and distribution of small wind systems (400-3000 watts). The company has been a pioneer in the development of wind technology and has built and shipped more than 170,000 wind turbines to over 120 countries worldwide. Headquartered in Flagstaff AZ, SWWP has sales representatives in over 88 countries. Applications for SWWP systems include residential homes, commercial properties, micro grids, remote cabins, telecom transmitters, offshore platforms, water pumping and sailboats. In addition, U.S. Department of Defense uses SWWP’s products in Forward Operating Bases (FOB’s), USGS uses them for remote monitoring of glacier movements and the CIA uses them to provide power seismic monitoring. Today, SWWP plans development of new technologies to address distributed energy market needs and become even more aggressive in international markets. This strategy includes extensive Research, Development, Demonstration & Deployment (RDD&D) activities to improve existing production line into more simple, reliable, and cost-effective wind turbine systems. Important part of such activities is the field testing of the new systems, which should provide: (i) validation of the reliable operation of hardware and software; (ii) validation of numerical models of the system and its components; (iii) field comparison of various control and optimization strategies; (iv) customized reliability testing; (v) customized monitoring and analysis testing; and (vi) IEC certification testing (vii) filed demonstration of system performance and reliability. Such field testing facility should encompass multiple towers and appropriate data acquisition systems. SWWP is exploring to move part of the engineering department to Colorado, and execute its RDD&D strategies in this new location. Partnership with NREL will provide great insights into SWWP’s RDD&D processes and more efficient commercialization by utilizing NWTC as the field testing site, and working close with NREL personnel. NWTC is ideally suited to strain the design. NREL is very experienced with customized and IEC testing. During this project, Southwest Windpower aims to improve the value proposition of distributed renewable energy, and make it a competitive choice in the energy markets. As of today, more then 170,000 small wind turbines, manufactured in the U.S., are installed in more then 180 countries. With the improved value proposition, Southwest Windpower wants to create and address new market needs, substantially increase its sales domestically and internationally, which should have positive impact on the creation of American jobs, competitiveness of U.S. economy, export or U.S. products, and the use of renewable energy.

17 WIND ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory (BMS and RMS SOP)

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronous High-frequency Distributed Readout For Edge Processing At The Fermilab Main Injector And Recycler

The Main Injector (MI) was commissioned using data acquisition systems developed for the Fermilab Main Ring in the 1980s. New VME-based instrumentation was commissioned in 2006 for beam loss monitors (BLM)[2], which provided a more systematic study of the machine and improved displays of routine operation. However, current projects are demanding more data and at a faster rate from this aging hardware. One such project, Real-time Edge AI for Distributed Systems (READS), requires the high-frequency, low-latency collection of synchronized BLM readings from around the approximately two-mile accelerator complex. Significant work has been done to develop new hardware to monitor the VME backplane and broadcast BLM measurements over Ethernet, while not disrupting the existing operations critical functions of the BLM system. This paper will detail the design, implementation, and testing of this parallel data pathway.

43 PARTICLE ACCELERATORS↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Comparative Analysis of ML Techniques for Data-Driven Anomaly Detection, Classification and Localization in Distribution System

High penetration of Distributed Energy Resources (DERs), fundamental load behavior changes, controllable loads, and significant increase in Electrical Vehicles (EVs) lead to complex dynamic behavior of the electric distribution system. Increasing number of components also means more measurements, more data and more data anomalies. Detecting, classifying and localizing these anomalies are important for situational awareness, and at the same time, very challenging given increasing complexity of the system. Highly accurate and high-resolution analytical techniques are needed to support anomaly detection, classification and localization (AD-C-L) for monitoring, root cause analysis and decision making. This paper provides comprehensive review and analysis of the existing spatio-temporal AD-C-L techniques within the distribution system. Challenges for specific problems in AD-C- L have been also discussed in this paper. Existing AD-C- L techniques have been categorized and synthesized for specific merits and limitations of multiple Machine Learning (ML) methodologies using common developed metrics of performance. The comparative analysis is summarized and presented with the open research challenges and path forward for future research needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Authentication of smart grid communications using quantum key distribution

Smart grid solutions enable utilities and customers to better monitor and control energy use via information and communications technology. Information technology is intended to improve the future electric grid’s reliability, efficiency, and sustainability by implementing advanced monitoring and control systems. However, leveraging modern communications systems also makes the grid vulnerable to cyberattacks. Here we report the first use of quantum key distribution (QKD) keys in the authentication of smart grid communications. In particular, we make such demonstration on a deployed electric utility fiber network. The developed method was prototyped in a software package to manage and utilize cryptographic keys to authenticate machine-to-machine communications used for supervisory control and data acquisition (SCADA). This demonstration showcases the feasibility of using QKD to improve the security of critical infrastructure, including future distributed energy resources (DERs), such as energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for the Operational Technology Environment (CyOTE) (Final Technical Report)

Electric grids have historically been susceptible to both physical attacks and environmental hazards but the implementation of smart grids, remote management, and self-healing networks, has now made the grid vulnerable to cyber attacks. To address risks introduced by routable connectivity, utilities must establish dynamic solutions to identify, protect, detect, respond to, and recover from cyber security threats and vulnerabilities. In response to the evolving threat landscape U.S. Department of Energy-Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER) initiated the Cybersecurity for the OT Environment (CyOTE) pilot program, a U.S. Department of Energy (DOE) effort designed to leverage U.S. intelligence capabilities to prevent, detect, or mitigate a cyber attack on utility operational technology (OT) networks. As part of the CyOTE pilot, The Southern Company (Southern Company or Southern) researched, evaluated and deployed emerging Commercial off the Shelf (COTS) technologies and cyber security monitoring architectures to provide previously unrealized network visibility and situational awareness through deep packet inspection and data analytics. This Final Scientific/Technical Report documents the objectives, methodology, lessons learned, and results of Southern Company’s participation in the CyOTE pilot from December 2018 to September 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗