Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “display”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development and evaluation of a method of calibrating medical displays based on fixed adaptation

Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrast levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.

60 APPLIED LIFE SCIENCES↗

Low Cost Field Emission Flat Panel Displays Final Report CRADA No. TC-0774-94

The ion accelerator at LLNL enabled the fabrication of field emitter cathodes with unique physical attributes not previously avaiIabIe. These properties enabled Candescent to fabricate field emission displays in a low cost, manufacturable manner with cathode performance (efficienq and emission quality) unprecedented in the industry. Candescent and LLNL delivered to ARPA, at the end of the 15 month program, a 3" diagonal black and white display with 80 lines per inch resolution, greater than 20 footlamberts brightness, and at least 16 levels of gray. Additionally, there was a like 3" diagonal color display DOE deliverable. In comparison to liquid crystal displays, the field emission display was brighter, sharper, and consumed 1/3 to 1/2 the power per unit area. The objective of the project was to confirm the efficacy of a new technology (ion tracking) for making efficient, cost effective cathodes for flat panel displays. LLNL was to provide the ion tracking system and experfise and Candescent was to provide the requirements, complete the fabrication of the cathodes, and incorporate them in flat panel displays. The program was quite successful. Candescent is now on the verge of commercializing 5.3 inch diagonal full color flat panel displays using this technology.

42 ENGINEERING↗

Display requirements for the final approach and landing phase of an RPV mission

A two part investigation was conducted to determine the display requirements for the final approach and landing phase of a remotely piloted vehicle (RPV) mission, and to assess the relative merits of several possible display configurations. The objective of the first part of the investigation was to obtain subjective assessments of several display configurations, and to select the most promising display concepts for subsequent evaluation in terms of performance measures. A basic display consisting of a perspective image of terrain and runway, a horizon bar and an aircraft symbol was used, and guidance symbology was added to the basic displaying selected state variables. Initial results suggested that as guidance symbology is added to the basic display, pilot acceptance tends to increase. A point of diminishing returns is eventually reached, however, when additional information produces too much clutter, and makes it difficult for the pilot to process the displayed information.

Howard, J. C.↗

An experimental evaluation of head-up display formats

Three types of head-up display format are investigated. Type 1 is an unreferenced (conventional) flight director, type 2 is a ground referenced flight path display, and type 3 is a ground referenced director. Formats are generated by computer and presented by reflecting collimation against a simulated forward view in flight. Pilots, holding commercial licenses, fly approaches in the instrument flight mode and in a combined instrument and visual flight mode. The approaches are in wind shear with varied conditions of visibility, offset, and turbulence. The displays are equivalent in pure tracking but there is a slight advantage for the unreferenced director in poor conditions. Flight path displays are better for tracking in the combined flight mode, possibly because of poor director control laws and the division of attention between superimposed fields. Workloads is better for the type 2 displays. The flight path and referenced director displays are criticized for effects of symbol motion and field limiting. In the subjective judgment of pilots familiar with the director displays, they are rated clearly better than path displays, with a preference for the unreferenced director. There is a fair division of attention between superimposed fields.

Naish, J. M.↗

Perception of aircraft separation with pilot-preferred symbology on a cockpit display of traffic information

The concept of a cockpit display of traffic information (CDTI) was developed for use in later full mission simulator evaluations of the CDTI concept. Pilots chose their preferred method of displaying air traffic information for several variables. Variables included: type of background, update rate, update type, predictor type, and history type. Each pilot designed a display he felt would be most useful in flight operations. After a series of test trials, each pilot was given the opportunity to modify the display for the experimental task. For a second day of testing, they repeated the experimental task using their display as well as displays chosen by other pilots. Results indicated a variety of individual preferences in symbology and differences in the accuracy of judgments. Pilots indicated concern for clutter of the display, relationship of the displayed symbology to physical reality, and a need to perceive the relative motion of the intruder aircraft. Analysis of data indicated that pilots were able to improve their performance with practice.

Oconnor, S.↗

The display of molecular models with the Ames Interactive Modeling System (AIMS)

A visualization of molecular models can lead to a clearer understanding of the models. Sophisticated graphics devices supported by minicomputers make it possible for the chemist to interact with the display of a very large model, altering its structure. In addition to user interaction, the need arises also for other ways of displaying information. These include the production of viewgraphs, film presentation, as well as publication quality prints of various models. To satisfy these needs, the display capability of the Ames Interactive Modeling System (AIMS) has been enhanced to provide a wide range of graphics and plotting capabilities. Attention is given to an overview of the AIMS system, graphics hardware used by the AIMS display subsystem, a comparison of graphics hardware, the representation of molecular models, graphics software used by the AIMS display subsystem, the display of a model obtained from data stored in molecule data base, a graphics feature for obtaining single frame permanent copy displays, and a feature for producing multiple frame displays.

Egan, J. T.↗

Factors affecting dwell times on digital displaying

A series of exploratory tests were conducted to investigate the effects of advanced display formats and display media on pilot scanning behavior using Langley's oculometer, a desktop flight simulator, a conventional electro-mechanical meter, and various digital displays. The primary task was for the test subject to maintain level flight, on a specific course heading, during moderate turbulence. A secondary task of manually controlling the readout of a display was used to examine the effects of the display format on a subject's scan behavior. Secondary task scan parameters that were evaluated were average dwell time, dwell time histograms, and number of dwells per meter change. The round dial meter demonstrated shorter dwell times and fewer dwells per meter change than the digital displays. The following factors affected digital display scanning behavior: (1) the number of digits; (2) the update rate of the digits; (3) the display media; and (4) the character font. The size of the digits used in these tests (0.28 to 0.50 inches) did not affect scan behavior measures.

Williams, A. J.↗

Development and evaluation of an airplane electronic display format aligned with the inertial velocity vector

The development of an electronic primary flight display format aligned with the aircraft velocity vector, a simulation evaluation comparing this format with an electronic attitude-aligned primary flight display format, and a flight evaluation of the velocity-vector-aligned display format are described. Earlier tests in turbulent conditions with the electronic attitude-aligned display format had exhibited unsteadiness. A primary objective of aligning the display format with the velocity vector was to take advantage of a velocity-vector control-wheel steering system to provide steadiness of display during turbulent conditions. Better situational awareness under crosswind conditions was also achieved. The evaluation task was a curved, descending approach with turbulent and crosswind conditions. Primary flight display formats contained computer-drawn perspective runway images and flight-path angle information. The flight tests were conducted aboard the NASA Transport Systems Research Vehicle (TSRV). Comparative results of the simulation and flight tests were principally obtained from subjective commentary. Overall, the pilots preferred the display format aligned with the velocity vector.

Steinmetz, G. G.↗

Design and evaluation of a cockpit display for hovering flight

A simulator evaluation of a cockpit display format for hovering flight is described. The display format is based upon the position-velocity-acceleration representation (PVA) similar to that used in the Pilot Night Vision System in the Army AH-64 helicopter. By only varying the nature of the display law driving the 'primary' indicator in the PVA format, i.e. the acceleration symbol, three candidate displays are created and evaluated. These range from a Status display in which the primary indicator provides true acceleration information to a Command display, in which the primary indicator provides flight director information. Simulation results indicate that two of the three displays offer performance and handling qualities which make them excellent candidates for future helicopter cockpit display systems.

Hess, Ronald A.↗

Design and evaluation of a cockpit display for hovering flight

A simulator evaluation of a cockpit display format for hovering flight is described. The display format is based on the position-velocity-acceleration representation (PVA) similar to that used in the Pilot Night Vision System in the Army AH-64 helicopter. By only varying the nature of the display law driving the primary indicator in the PVA format, i.e., the acceleration symbol, three candidate displays are created and evaluated. These range from a Status display in which the primary indicator provides true acceleration information to a Command display, in which the primary indicator provides flight director information. Simulation results indicate that two of the three displays offer performance and handling qualities which make them excellent candidates for future helicopter cockpit display systems.

Hess, Ronald A.↗

The Real Time Display Builder (RTDB)

The Real Time Display Builder (RTDB) is a prototype interactive graphics tool that builds logic-driven displays. These displays reflect current system status, implement fault detection algorithms in real time, and incorporate the operational knowledge of experienced flight controllers. RTDB utilizes an object-oriented approach that integrates the display symbols with the underlying operational logic. This approach allows the user to specify the screen layout and the driving logic as the display is being built. RTDB is being developed under UNIX in C utilizing the MASSCOMP graphics environment with appropriate functional separation to ease portability to other graphics environments. RTDB grew from the need to develop customized real-time data-driven Space Shuttle systems displays. One display, using initial functionality of the tool, was operational during the orbit phase of STS-26 Discovery. RTDB is being used to produce subsequent displays for the Real Time Data System project currently under development within the Mission Operations Directorate at NASA/JSC. The features of the tool, its current state of development, and its applications are discussed.

Kindred, Erick D.↗

Spatial displays as a means to increase pilot situational awareness

Experiences raise a number of concerns for future spatial-display developers. While the promise of spatial displays is great, the cost of their development will be correspondingly large. The knowledge and skills which must be coordinated to ensure successful results is unprecedent. From the viewpoint of the designer, basic knowledge of how human beings perceive and process complex displays appears fragmented and largely unquantified. Methodologies for display development require prototyping and testing with subject pilots for even small changes. Useful characterizations of the range of differences between individual users is nonexistent or at best poorly understood. The nature, significance, and frequency of interpretation errors associated with complex integrated displays is unexplored and undocumented territory. Graphic displays have intuitive appeal and can achieve face validity much more readily than earlier symbolic displays. The risk of misleading the pilot is correspondingly greater. Thus while some in the research community are developing the tools and techniques necessary for effective spatial-display development, potential users must be educated about the issues so that informed choices can be made. The scope of the task facing all is great. The task is challenging and the potential for meaningful contributions at all levels is high indeed.

Fadden, Delmar M.↗

Management and display of four-dimensional environmental data sets using McIDAS

Over the past four years, great strides have been made in the areas of data management and display of 4-D meteorological data sets. A survey was conducted of available and planned 4-D meteorological data sources. The data types were evaluated for their impact on the data management and display system. The requirements were analyzed for data base management generated by the 4-D data display system. The suitability of the existing data base management procedures and file structure were evaluated in light of the new requirements. Where needed, new data base management tools and file procedures were designed and implemented. The quality of the basic 4-D data sets was assured. The interpolation and extrapolation techniques of the 4-D data were investigated. The 4-D data from various sources were combined to make a uniform and consistent data set for display purposes. Data display software was designed to create abstract line graphic 3-D displays. Realistic shaded 3-D displays were created. Animation routines for these displays were developed in order to produce a dynamic 4-D presentation. A prototype dynamic color stereo workstation was implemented. A computer functional design specification was produced based on interactive studies and user feedback.

Hibbard, William L.↗

Improvements in hover display dynamics for a combat helicopter

This paper describes a piloted simulation conducted on the NASA Ames Vertical Motion Simulator. The objective of the experiment was to investigate the handling qualities benefits attainable using new display law design methods for hover displays. The new display laws provide improved methods to specify the behavior of the display symbol that predicts the vehicle's ground velocity in the horizontal plane; it is the primary symbol that the pilot uses to control aircraft horizontal position. The display law design was applied to the Apache helmet-mounted display format, using the Apache vehicle dynamics to tailor the dynamics of the velocity predictor symbol. The representations of the Apache vehicle used in the display design process and in the simulation were derived from flight data. During the simulation, the new symbol dynamics were seen to improve the pilots' ability to maneuver about hover in poor visual cuing environments. The improvements were manifested in pilot handling qualities ratings and in measured task performance. The paper details the display design techniques, the experiment design and conduct, and the results.

Eshow, Michelle M.↗

Improvements in hover display dynamics for a combat helicopter

This paper describes a piloted simulation conducted on the NASA Ames Vertical Motion Simulator. The objective of the experiment was to investigate the handling qualities benefits attainable using new display law design methods for hover displays. The new display laws provide improved methods to specify the behavior of the display symbol that predicts the vehicle's ground velocity in the horizontal plane; it is the primary symbol that the pilot uses to control aircraft horizontal position. The display law design was applied to the Apache helmet-mounted display format, using the Apache vehicle dynamics to tailor the dynamics of the velocity predictor symbol. The representations of the Apache vehicle used in the display design process and in the simulation were derived from flight data. During the simulation, the new symbol dynamics were seen to improve the pilots' ability to maneuver about hover in poor visual cuing environments. The improvements were manifested in pilot handling qualities ratings and in measured task performance. The paper details the display design techniques, the experiment design and conduct, and the results.

Eshow, Michelle M.↗

Handling qualities effects of display latency

Display latency is the time delay between aircraft response and the corresponding response of the cockpit displays. Currently, there is no explicit specification for allowable display lags to ensure acceptable aircraft handling qualities in instrument flight conditions. This paper examines the handling qualities effects of display latency between 70 and 400 milliseconds for precision instrument flight tasks of the V-22 Tiltrotor aircraft. Display delay effects on the pilot control loop are analytically predicted through a second order pilot crossover model of the V-22 lateral axis, and handling qualities trends are evaluated through a series of fixed-base piloted simulation tests. The results show that the effects of display latency for flight path tracking tasks are driven by the stability characteristics of the attitude control loop. The data indicate that the loss of control damping due to latency can be simply predicted from knowledge of the aircraft's stability margins, control system lags, and required control bandwidths. Based on the relationship between attitude control damping and handling qualities ratings, latency design guidelines are presented. In addition, this paper presents a design philosophy, supported by simulation data, for using flight director display augmentation to suppress the effects of display latency for delays up to 300 milliseconds.

King, David W.↗

Development and Demonstration of a Prototype Free Flight Cockpit Display of Traffic Information

Two versions of a prototype Free Flight cockpit situational display (Basic and Enhanced) were examined in a simulation at the NASA Ames Research Center. Both displays presented a display of traffic out to a range of 120 NM, and an alert when the automation detected a substantial danger of losing separation with another aircraft. The task for the crews was to detect and resolve threats to separation posed by intruder aircraft. An Enhanced version of the display was also examined. It incorporated two additional conflict alerting levels and tools to aid in trajectory prediction and path planning. Ten crews from a major airline participated in the study. Performance analyses and pilot debriefings showed that the Enhanced display was preferred, and that minimal separation between the intruder and the ownship was larger with the Enhanced display. In addition, the additional information on the Enhanced display did not lead crews to engage in more maneuvering. Instead an opposite trend was indicated. Finally, crews using the Enhanced display responded more proactively, tending to resolve alerts earlier.

Johnson, Walter W.↗

Performance Effects of Display Incogruity in a Digital and Analog Clock Reading Task

In an era of increasing automation, it is important to design displays and input devices that minimize human error. In this context, information concerning the human response to the detection of incongruous information is important. Such incongruous information can be operationalized as unexpected (perhaps erroneous) information on which a decision by the human or operation by an automated system is based. In the aviation environment, decision making when faced with inadequate, incomplete, or incongruous information may occur in a failure scenario. An additional challenge facing the human operator in automated environments is maintaining alertness or vigilance. The vigilance issue is of particular concern as a factor that may interact with performance when faced with inadequate, incomplete, or incongruous information. From the literature on eye-scan behavior we know that the time spent looking at a particular display or indicator is a function of the type of information one is trying to discern from the display. For example, quick glances are all it takes for confirming that an indicator is in a normal position or range, whereas a continuous look of several seconds may be required for confirmation that a complex control input is having the desired effect. Important to consider is that while an extended look takes place, visual input from other sources may be missed. Much like an extended look, the interpretation of incongruous information may require extra time. The present experiment was designed to explore the performance consequences of a decision making task when incongruous information was presented. For this experiment a display incongruity was created on a subset of trials of a clock reading laboratory task. Display incongruity was made possible through presentation of 'impossible' times (e.g. 1:65 or 11:90). Subjects made 'same' 'different' decisions and keyboard responses to pairings of Analog-Analog (AA), Digital-Digital (DD), and Analog- Digital (AD), display combinations. For trials during which display incongruities were not presented, based on prior research comparing digital and analog clock displays, it would be expected that the Digital-Digital condition would result in the shortest response times and the Analog-Analog and Analog-Digital conditions would have longer response times. The performance consequence expected on trials with incongruous times would be very long response times.

J. Raymond Comstock, Jr.↗