Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “directional heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analysis and comparison of wall cooling schemes for advanced gas turbine applications

The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.

Colladay, R. S.↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Microwave Sterilization and Depyrogenation System

A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time at a given flow rate. These technologies can be employed in small-scale systems for efficient production of MGW in the laboratory or in a range of larger systems that meet various industrial requirements. The microwave antennas can also be adapted to selectively sterilize vulnerable connections to ultra-pure water production facilities or biologically vulnerable systems where microorganisms may intrude.

Akse, James R.↗

Multi-Element Water Content System Instrument Handbook

The SEA Model WCM-2000 multi-element water content system was designed to provide aircraft and wind tunnel users with a single, rugged sensor to simultaneously measure liquid water content (LWC), total water content (TWC), and ice water content (IWC). The instrument consists of four heated stainless steel elements, each with a different shape or size. Each element is directly heated by low-voltage DC current flowing through the element. These elements are maintained at a constant temperature, typically 140°C, by a digital closed-loop control system. Three of the heated elements are exposed directly to the airstream and incoming cloud water. A fourth element, the reference/comp element, is arranged to be exposed to the airflow but not to incoming cloud water. This element is used to establish the “dry power term” that is subtracted from the other three elements’ power readings to establish the measured water content.

54 ENVIRONMENTAL SCIENCES↗

Development of a Flow Stabilization Algorithm Enabling Measurement of Low Oxygen Concentrations in Liquid Sodium

To enhance the automated control of the plugging meter (PM) and thereby enhance detection fidelity in ultralow oxygen environments [≤1 parts per million by weight (wppm)], a novel proportional derivative controller has been implemented with conventional PM hardware. This ramp sign stabilized flow (RSSF) controller manipulates the sign (heating or cooling direction) at a fixed rate, enabling precise temperature adjustment around the saturation temperature of the bulk sodium. This adjustment helps maintain flow stability in a partially formed sodium oxide plug, thus greatly reducing the temperature amplitude in the plugging cycle and promoting simple and accurate oxygen determinations in addition to an increased sampling rate. Rather than relying on the subjective nature of indexing the time when the flow rate changes due to the plugging or unplugging onset to the PM temperature, a running average of the correlated oxygen concentration with time over multiple plugging events can provide oxygen readings ranging from an absolute uncertainty of 500 wppb in real time to less than 50 wppb for a 24-h sampling window. Finally, the RSSF controller was tested at 508 ± 7 wppb with measured oxygen of 542 ± 179 wppb, further reducing the variance between the saturation temperature and the plugging temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Fin Passage Length on Optimization of Cylinder Head Cooling Fins

The heat transfer performance of baffled cooling fins on cylinder heads of small, air-cooled, general-aviation aircraft engines was analyzed to determine the potential for improving cooling fin design. Flow baffles were assumed to be installed tightly against the fin end edges, an ideal baffle configuration for guiding all flow between the fins. A rectangular flow passage is thereby formed between each set of two adjacent fins, the fin base surface, and the baffle. These passages extend around each side of the cylinder head, and the cooling air absorbs heat as it flows within them. For each flow passage length, the analysis was concerned with optimizing fin spacing and thickness to achieve the best heat transfer for each fin width. Previous literature has been concerned mainly with maximizing the local fin conductance and has not considered the heating of the gas in the flow direction, which leads to higher wall temperatures at the fin passage exits. If the fins are close together, there is a large surface area, but the airflow is restricted.

Siegel, R.↗

Analysis of evaporative water loss in the Skylab astronauts

Daily evaporative water losses (EWL) during the three Skylab missions were measured using the indirect mass and water balance techniques. A mean inflight EWL of 860 ml/day-m 2 was obtained for nine men who averaged one hour of daily exercise. Although it was expected the EWL would increase in the hypobaric environment of Skylab (1/3 atmosphere), an average decrease from preflight sea level conditions of 11 percent was measured. The results suggest that weightlessness may have been a factor in modifying EWL primarily by decreasing sweat losses during exercise and possibly by reducing insensible skin losses as well. The weightless environment apparently promotes the formation of a sweat film on the skin surface both directly, by reducing heat and mass convective flow and sweat drippage, and perhaps indirectly by inducing measurable biochemical changes resulting in high initial sweating rates. It is proposed that these high levels of skin wettedness favor sweat suppression by a previously described mechanism.

Leonard, J. I.↗

Multi-Node Modeling of Cryogenic Tank Pressurization System using Generalized Fluid System Simulation Program

This paper presents a multi-node model of autogenous pressurization of cryogenic propellant in a flight tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code developed at NASA/Marshall Space Flight Center. Tests were conducted to measure the pressure and temperatures at the various axial locations of the stratified ullage at 75% and 45% fill level. Liquid nitrogen was pressurized by gaseous nitrogen from a supply tank while the drain valve from the tank remained closed during the pressurization process. The ullage was discretized into 25 uniformly distributed nodes: 5 in the radial direction and 5 in the axial direction assuming the flow to be axisymmetric. Heat and mass transfer between the liquid and vapor has been modeled at the liquid vapor interface. Heat transfer between wall and vapor at the ullage has been accounted for by assuming heat transfer occurs by natural convection. The model also accounts for heat leak to the tank through the insulation and metal wall by heat conduction. The predicted pressures and temperatures are compared with the measured data.

Bandyopadhyay, Alak↗

Magnetospheric Multiscale Mission Observations of Reconnecting Electric Fields in the Magnetotail on Kinetic Scales

We examine the role of ions and electrons in reconnection using the highest resolution observations from the Magnetospheric Multiscale mission on kinetic ion and electron scales. We report magnetic field and plasma observations from several approaches to the electron diffusion region in the current sheet in 2018. Besides magnetic field reversals, changes in the direction of flow velocity, ion and electron heating, Magnetospheric Multiscale observed large fluctuations in the electron flow speeds in the magnetotail. We have verified that when the field lines and plasma become decoupled, a large reconnecting electric field related to the Hall current (1–10 mV/m) is responsible for fast reconnection in the ion diffusion region. Although inertial acceleration forces remain moderate (1–2 mV/m), the electric fields resulting from the electron pressure tensor provide the main contribution to the generalized Ohm's law at the neutral sheet (as large as 200 mV/m). This illustrates that when ions decouple electron physics dominates.

Macek, W. M.↗

Stirling Engine With Radial Flow Heat Exchangers

Conflict between thermodynamical and structural requirements resolved. In Stirling engine of new cylindrical configuration, regenerator and acceptor and rejector heat exchangers channel flow of working gas in radial direction. Isotherms in regenerator ideally concentric cylinders, and gradient of temperature across regenerator radial rather than axial. Acceptor and rejector heat exchangers located radially inward and outward of regenerator, respectively. Enables substantial increase in power of engine without corresponding increase in diameter of pressure vessel.

Vitale, N.↗

Magnetic heat pump flow director

A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

Howard, Frank S.↗

Results of convective heating tests of a longitudinal gap on the Rockwell flat plate model (15-0, insert 7) in the NASA/Ames Research Center

Results are presented which were obtained from tests in a hypersonic wind tunnel to determine aerodynamic heating rates in a gap running parallel or slightly askew to the flow direction. The model used was a flat plate instrumented in thin-skin sections with chromelconstantan thermocouples. Heating rate profiles lengthwise along and down into the gap were obtained, and additional data were obtained from a total temperature probe and rake fabricated during the test to investigate an apparent aerodynamic cooling trend in the gap. Model variables were width, depth, length, and orientation of the gap relative to the flow direction. The tests were conducted at Mach 5.1 and Reynolds numbers per foot of 500,000, 1,000,000, and 2,000,000.

Quan, M.↗

A direct-interface, fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some of the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototype with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

A direct-interface fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototpye with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

A continuum model for heat and mass transfer in moving-bed reactors for thermochemical energy storage

In this work, a continuum heat and mass transfer model coupling transport phenomena and high-temperature thermochemical reactions is developed for stationary packed-bed and counter-flow moving-bed reactors. After presenting the general modeling framework, we focus on the 2D axisymmetric version of the model for which validation is conducted with experimental results for a packed-bed reactor in the literature for manganese-iron oxide reduction/oxidation and an in-house counter-flow moving-bed reactor for magnesium-manganese oxide reduction up to 1450 °C. Transient simulation results including the local distributions of gas/solid temperatures, oxygen concentration and the extent of reaction, as well as the various energy flow components and energy conversion efficiencies are reported. The results based on the 2D axisymmetric model are also compared with those obtained from a previous 1D model. The comparison shows that capturing the radial variation is critical in reactor modeling and the 2D results demonstrate improved agreement with experiments. Specifically, large temperature variations along the radial direction are observed especially in the reaction zone; this non-uniform radial temperature distribution has a significant effect on the chemical reaction extent due to its strong dependence on temperature; and the overall oxygen concentration at the reactor exit and the predicted system efficiency are slightly lower in the 2D model compared to the 1D model. Finally, the present heat and mass transfer model can provide valuable insights into reactor design, scale-up, and operating conditions selection to maximize system energy storage efficiency.

25 ENERGY STORAGE↗

Reentry heating and flow fields for Space Shuttle Orbiter at high angle of attack.

Rarefied flow fields and heating rates are calculated by a Monte Carlo direct simulation technique for several shuttle orbiter configurations at angles of attack between 40 and 60 deg. Continuum inviscid flow fields are determined by 2-D unsteady and 3-D steady finite-difference/artificial viscosity techniques used in combination with a 2-D shock layer analysis method. Continuum viscous flow fields and heating rates are computed by a boundary-layer integral matrix technique and an aerodynamic heating method.

Rochelle, W. C.↗

Investigations of a turbulent jet in a crossflow

Analyses of flow field downstream of jet directed at right angles into crossflow for heated and unheated single jets are presented. Application of flow data to cooling system for gas turbine combustion chambers is discussed. Temperature distribution, velocity trajectory, and vortex motion are described.

Kamotani, Y.↗

Flow Quality Surveys in the Settling Chamber of the NASA Glenn Icing Research Tunnel (2011 Tests)

In 2011, the heat exchanger and refrigeration plant for NASA Glenn Research Center's Icing Research Tunnel (IRT) were upgraded. Flow quality surveys were performed in the settling chamber of the IRT in order to understand the effect that the new heat exchanger had on the flow quality upstream of the spray bars. Measurements were made of the total pressure, static pressure, total temperature, airspeed, and flow angle (pitch and yaw). These measurements were directly compared to measurements taken in 2000, after the previous heat exchanger was installed. In general, the flow quality appears to have improved with the new heat exchanger.

Steen, Laura E.↗