Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct normal irradiance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Large-scale production of 88 Y and 88 Zr/ 88 Y generators: A proof of concept study for a 70 MeV H – cyclotron

Here, the large-scale production of 88 Y with proton-induced reactions has been investigated from the perspective of new generation 70 MeV H – cyclotrons. Tandem target configurations are presented for both the direct production of 88 Y as well as for producing 88 Zr/ 88 Y generators. Based on the relevant excitation functions, physical yields have been derived for 88 Y production with Y 2 O 3 /SrCO 3 tandem targets and 88 Zr production with Zr/Y 2 O 3 tandem targets. Yields are presented for optimized targets (i.e. optimum yield) as well as for balanced thermal loads on the individual targets. Liquid 88 Zr/ 88 Y generators have been produced using both natural Zr and Nb target materials, the former for dedicated productions and the latter as a byproduct by processing spent irradiated Nb capsules which normally would constitute radioactive waste. These stock solutions, which contain both the target material and 88 Zr precursor, are retained virtually unchanged after processing except for the removal of 88 Y on AG MP-50 macroporous cation-exchange resin. Methods are presented for the preparation of Nb stock solutions in hydrofluoric acid and Zr stock solutions in sulfuric acid. It is shown that multi-Ci productions of 88 Y are feasible at a 70 MeV cyclotron facility, suitable for the needs of fracking applications. In addition, 88 Zr/ 88 Y generators can provide 88 Y with very high specific activity, suitable for labelling of biomolecules.

07 ISOTOPE AND RADIATION SOURCES↗

Proton beam quality enhancement by spectral phase control of a PW-class laser system

We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Hindlimb Unloading and Ionizing Radiation on Murine Gene Expression in Skin and Bone

Long duration spaceflight causes a negative calcium balance and reduces bone density in astronauts. The underlying mechanisms of spaceflight-induced bone loss and the possible influences of both microgravity and radiation are not fully understood although emerging evidence suggests that these two factors may interact to result in increased bone loss. Previously, gene expression analysis of hair follicles from astronauts, as well as skin from space-flown mice, revealed changes in the expression of genes related to DNA damage and oxidative stress responses. These results resemble the responses of bone to spaceflight-like radiation and simulated weightlessness by hindlimb unloading (HU). Hence in this study, we initiated studies to determine whether skin can be used to predict the responses of bone to simulated microgravity and radiation. We examined oxidative stress and growth arrest pathways in mouse skin and long bones by measuring gene expression levels via quantitative polymerase chain reaction (qPCR). To investigate the effects of irradiation andor HU on gene expression, we used skin and femora (cortical shaft) from the following treatment groups: control (normally loaded, sham-irradiated) (CT), hindlimb unloading (HU), 56Fe radiation (IR) and both HU+IR. Animals were euthanized 11 days post-IR, and results were analyzed by 1-way ANOVA. In skin samples, Cdkn1a was decreased to the same extent in HU and HU+IR (47 of CT). In addition, HU reduced FoxO3 expression (46 of CT) and IR increased Gadd45g expression 135 compared CT in skin. But in bone, HU increased FoxO3 expression 31 compared the level of CT. These results suggest that radiation and simulated weightlessness regulated simliar oxidative stress and cell cycle arrest genes in both skin and bone, although the time course and direction of changes may differ. This research may lead to the development of a relatively simple diagnostic tool for bone loss with the advantage that hair follicles and skin are relatively easy to acquire from subjects.

Terada, Masahiro↗

Total ozone determination by spectroradiometry in the middle ultraviolet

A method has been developed to determine total ozone from multispectral measurements of the direct solar irradiance. The total ozone is determined by a least squares fit to the spectrum between 290 nm and 380 nm. The aerosol extinction is accounted for by expanding it in a power series in wavelength; use of the linear term proved adequate. A mobile laboratory incorporating a sky scanner has been developed and used to obtain data to verify the method. Sun tracking, wavelength setting of the double monochromator, and data acquisition are under control of a minicomputer. Results obtained at Wallops Island, Virginia, and Palestine, Texas, agree well with simultaneous Dobson and Canterbury spectrometer and balloon ECC ozonesonde values. The wavelength calibration of the monochromator and the values for the normalized ozone absorption are the most important factors in an accurate determination of total ozone.

Garrison, L. M.↗

Senegalese land surface change analysis and biophysical parameter estimation using NOAA AVHRR spectral data

Surface biophysical estimates were derived from analysis of NOAA Advanced Very High Spectral Resolution (AVHRR) spectral data of the Senegalese area of west Africa. The parameters derived were of solar albedo, spectral visible and near-infrared band reflectance, spectral vegetative index, and ground temperature. Wet and dry linked AVHRR scenes from 1981 through 1985 in Senegal were analyzed for a semi-wet southerly site near Tambacounda and a predominantly dry northerly site near Podor. Related problems were studied to convert satellite derived radiance to biophysical estimates of the land surface. Problems studied were associated with sensor miscalibration, atmospheric and aerosol spatial variability, surface anisotropy of reflected radiation, narrow satellite band reflectance to broad solar band conversion, and ground emissivity correction. The middle-infrared reflectance was approximated with a visible AVHRR reflectance for improving solar albedo estimates. In addition, the spectral composition of solar irradiance (direct and diffuse radiation) between major spectral regions (i.e., ultraviolet, visible, near-infrared, and middle-infrared) was found to be insensitive to changes in the clear sky atmospheric optical depth in the narrow band to solar band conversion procedure. Solar albedo derived estimates for both sites were not found to change markedly with significant antecedent precipitation events or correspondingly from increases in green leaf vegetation density. The bright soil/substrate contributed to a high albedo for the dry related scenes, whereas the high internal leaf reflectance in green vegetation canopies in the near-infrared contributed to high solar albedo for the wet related scenes. The relationship between solar albedo and ground temperature was poor, indicating the solar albedo has little control of the ground temperature. The normalized difference vegetation index (NDVI) and the derived visible reflectance were more sensitive to antecedent rainfall amounts and green vegetation changes than were near-infrared changes. The information in the NDVI related to green leaf density changes primarily was from the visible reflectance. The contribution of the near-infrared reflectance to explaining green vegetation is largely reduced when there is a bright substrate.

Vukovich, Fred M.↗

Improved Atmospheric Correction for AVIRIS Spectra from Inland Waters

Remote sensing reflectance (Rrs) cannot be measured directly. Comparison of Rrs calculated from field measurements to Rrs calculated from AVIRIS spectra and the atmospheric radiative transfer model modtran provides a measure of the accuracy of our method. That and other comparisons are presented here as a validation of a method of retrieving Rrs from inland waters from AVIRIS radiance. The method of collecting field measurements for Rrs is described in Hamilton, 1993. Retrieval of Rrs from AVIRIS using modtran was developed from Carder, 1993. AVIRIS radiance is reduced by the path radiance modeled by modtran and divided by one-way transmission. Skylight, modeled by modtran, specularly reflected from the lake surface, is then subtracted from this radiance, leaving only that radiance which has come from under water. This water-leaving radiance is then normalized by the downwelling irradiance incident at the surface as modeled by modtran. Our improved retrieval of Rrs has allowed us to fit a single curve to a set of 134 pairs of AVIRIS Rrs and measured chlorophyll gathered on eight experiments at Mono Lake. Previously, spectra from different surveys varied more due to lingering atmospheric effects and/or radiometric calibration imprecision than they varied due to chlorophyll.

Gastil, Mary↗

SeaWiFS technical report series. Volume 16: The second SeaWiFS Intercalibration Round-Robin Experiment, SIRREX-2, June 1993

The results of the second Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-2), which was held at the Center for Hydro-Optics and Remote Sensing (CHORS) at San Diego State University on 14-25 Jun. 1993 are presented. SeaWiFS is an ocean color radiometer that is scheduled for launch in 1994. The SIRREXs are part of the SeaWiFS Calibration and Validation Program that includes the GSFC, CHORS, NIST, and several other laboratories. GSFC maintains the radiometric scales (spectral radiance and irradiance) for the SeaWiFS program using spectral irradiance standards lamps, which are calibrated by NIST. The purpose of each SIRREX is to assure that the radiometric scales which are realized by the laboratories who participate in the SeaWiFS Calibration and Validation Program are correct; that is, the uncertainties of the radiometric scales are such that measurements of normalized water-leaving radiance using oceanographic radiometers have uncertainties of 5%. SIRREX-1 demonstrated, from the internal consistency of the results, that the program goals would not be met without improvements to the instrumentation. The results of SIRREX-2 demonstrate that spectral irradiance scales realized using the GSFC standard irradiance lamp (F269) are consistent with the program goals, as the uncertainty of these measurements is assessed to be about 1%. However, this is not true for the spectral radiance scales, where again the internal consistency of the results is used to assess the uncertainty. This is attributed to inadequate performance and characterization of the instrumentation. For example, spatial nonuniformities, spectral features, and sensitivity to illumination configuration were observed in some of the integrating sphere sources. The results of SIRREX-2 clearly indicate the direction for future work, with the main emphasis on instrument characterization and the assessment of the measurement uncertainties so that the results may be stated in a more definitive manner.

Hooker, Stanford B.↗

Anomaly Detection for Online Monitoring of Thermocouple Sensors in the Advanced Test Reactor

This study explores data-driven anomaly detection methods to analyze sensor fail- ures in the Advanced Gas Reactor (AGR) nuclear fuel irradiation experiments. Specifically, we examine failures of thermocouples (TCs), which are critical for mon- itoring and controlling in-reactor temperatures during operation. Failures were pri- marily observed during abrupt power transitions and manifested as sensor drop-outs, drifts, or unexplained behavior. We applied three time-series analysis techniques— rolling mean smoothing, matrix profile, and vector auto-regression (VAR)—to de- tect anomalies in TC data prior to failure events. The rolling mean method effec- tively highlighted deviations aligned with reported failures, while the matrix profile provided partial early warning but sometimes flagged normal fluctuations during power-down periods. VAR shows potential in capturing multivariate dependencies but requires further calibration. A rare case of TC drift was also documented, which did not result in failure, underscoring the challenge of building predictive models with sparse positive examples. Our findings demonstrate that traditional statistical tools can aid anomaly detection but have limited predictive power without richer training data. We propose future directions including synthetic data generation, real- time surrogate modeling, and multi-modal feature integration. This work provides a foundation for applying robust anomaly detection frameworks to mission-critical sensor systems in experimental settings.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In Vitro Studies on Space Radiation-Induced Delayed Genetic Responses: Shielding Effects

Understanding the radiation risks involved in spaceflight is of considerable importance, especially with the long-term occupation of ISS and the planned crewed exploration missions. Several independent causes may contribute to the overall risk to astronauts exposed to the complex space environment, such as exposure to GCR as well as SPES. Protons and high-Z energetic particles comprise the GCR spectrum and may exert considerable biological effects even at low fluence. There are also considerable uncertainties associated with secondary particle effects (e.g. HZE fragments, neutrons etc.). The interaction of protons and high-LET particles with biological materials at all levels of biological organization needs to be investigated fully in order to establish a scientific basis for risk assessment. The results of these types of investigation will foster the development of appropriately directed countermeasures. In this study, we compared the biological responses to proton irradiation presented to the target cells as a monoenergetic beam of particles of complex composition delivered to cells outside or inside a tissue phantom head placed in the United States EVA space suit helmet. Measurements of chromosome aberrations, apoptosis, and the induction of key proteins were made in bone marrow from CBA/CaJ and C57BL/6 mice at early and late times post exposure to radiation at 0, 0.5, 1 and 2 Gy while inside or outside of the helmet. The data showed that proton irradiation induced transmissible chromosomal/genomic instability in haematopoietic stem cells in both strains of mice under both irradiation conditions and especially at low doses. Although differences were noted between the mouse strains in the degree and kinetics of transforming growth factor-beta 1 and tumor necrosis factor-alpha secretion, there were no significant differences observed in the level of the induced instability under either radiation condition, or for both strains of mice. Consequently, when normalized to physical dose, the monoenergetic proton field present inside the helmet-protected phantom produced equivalent biological responses, when compared to unshielded cells, as measured by the induction of delayed genetic effects in murine haematopoietic stem cells.

Kadhim, Munira A.↗

Diffusion of small anti-Schottky clusters in UO 2

The aggregation of irradiation-induced defect clusters in UO 2 leads to the formation of dislocation loops and cavities which contribute swelling and ultimately produce deleterious effects on the fuel. Despite their fundamental role in fuel evolution, the kinetics of these defect clusters are not currently well understood. In this work, we investigate the diffusive behavior of interstitial clusters via Molecular Dynamics (MD) simulations. In this work, our investigation considers a range of defect cluster sizes, each composed of N UO 2 units or anti-Schottky defects. We report a complex cluster size - mobility relation; increasing cluster size corresponds to an increase in mobility up until a critical size (N=4) where diffusivity reaches a maximum, after which the trend reverts and further increasing size corresponds to a decrease in mobility. The rapid migration observed correlates well with the very low barriers reported in a few historic experimental studies. Further analysis of the cluster shape and orientation reveals a strong structural preference for near-planar configurations oriented normal to the $\langle$100$\rangle$ direction. Rotational energy barriers are found to be similar in both magnitude and trend to the observed diffusion barriers. Lastly, connections are drawn to the behavior of large defect clusters including the formation of (1/3) $\langle$111$\rangle$ Frank dislocation loops.

36 MATERIALS SCIENCE↗

Circulating miRNA Signature Predicts Health Risks Associated with Radiation and Microgravity

The many known health risks currently associated with space travel include increased risk of cardiovascular disease, cancer, central nervous system related diseases, muscle degeneration, and changes with host-gut microbiome interactions that can have profound impact with these and other health risks. The majority of the risk from space travel stem of the two components of the space environment which are microgravity and radiation. From our earlier work (Beheshti et al, PLOS One, 2018), we predicted that there is a systemic component of the host that causes general increased health risks due to spaceflight driven by a circulating microRNA (miRNA) signature consisting of 13 miRNAs that directly regulates both p53 and TGF1. MiRNAs are small non-coding RNA molecules with a negative and post-transcriptional regulation on gene expression) are increasingly recognized as major systemic regulators of responses to stressors, including microgravity, oxidative stress, and DNA damage. In addition, due to the size and stability of miRNAs, it is known that miRNAs can circulate throughout the body and have been found in the majority of the bodily fluids including blood, urine, saliva, and tears. Here, we start to dissect the actual impact of this miRNA signature on both the radiation and microgravity components and prove that this miRNA signature actually exists in the circulation of a host. To achieve this, we obtained multiple tissues including, serum, liver, and spleen and utilizing droplet digital PCR (ddPCR), we start to show how this circulating miRNA signature impacts which component of the spaceflight. The tissue was obtained from experiments performed on C57BL/6 male mice (N=10 for each condition) that were hindlimb unloaded (HU) to simulated microgravity, irradiated with 2Gy gamma (IR), HU plus IR, and control mice under normal conditions. It was shown that these miRNAs were present in the serum as predicted by the in silico prediction from our earlier predictions. The HU vs Controls show significant increases of the predicted miRNAs in the serum for more than half of the miRNA signature, with remaining miRNAs increasing comparing to the controls close to statistical significance. IR vs control mice showed increases for the miRNAs, but not has pronounced as the HU conditions. Finally, the combination of the HU+IR vs controls showed increases for the majority of the miRNA signature. The data indicates that the miRNA signature originally predicted through in silico methods is mainly associated with the microgravity component and is circulating throughout the host resulting in a systemic impact of the miRNAs on the host. These miRNAs are shown in the literature to potentially increase health risks associated with several diseases. In addition, we have begun testing the potential of utilizing antagonists to this miRNA signature to act as a potential countermeasure to mitigate radiation impact on the organism. This work demonstrates for the first time the potential of a minimally invasive novel biomarker and countermeasure that can be used to mitigate both radiation and microgravity effects.

Beheshti, Afshin↗

Bidirectional reflectance of oceanic waters: A comparison of modeled and measured upward radiance fields

The bidirectional reflectance of oceanic waters is conveniently described in a normalized way by forming the ratio of the upwelling irradiance E(sub u) to any upwelling radiance L(sub u)(theta prime, phi). This ratio, Q (theta prime, theta(sub 0), (phi(sub 0) - phi), where theta prime, phi are the nadir and azimuth angles for the upward radiance and theta(sub 0), phi(sub 0) are the zenith and azimuth angles of the Sun, has been determined from measurements at sea and computed via Monte Carlo simulations using the inherent optical properties measured in the field and appropriate boundary conditions (clear sky, no wind, varying Sun angle). Experimental ad computed Q values are in excellent agreement. This successful comparison confirms the importance of the bidirectional character of ocean reflectance, already pointed out from a purely numerical approach without field validation, and corroborates the extended range of the Q variations. The later point is of importance when interpreting the marine signals detected by an ocean color satellite-borne sensor. The validation is extended by considering the historical data for the radiance distributions in Lake Pend Oreille determined at various depths. The closure issue in ocean optics is examined by solving the direct problem of radiative transfer and through a model-data comparison in terms of radiance field.

Morel, Andre↗

Gravity-dependent polarity of cytoplasmic streaming in Nitellopsis

The internodal cells of the characean alga Nitellopsis obtusa were chosen to investigate the effect of gravity on cytoplasmic streaming. Horizontal cells exhibit streaming with equal velocities in both directions, whereas in vertically oriented cells, the downward-streaming cytoplasm flows ca. 10% faster than the upward-streaming cytoplasm. These results are independent of the orientation of the morphological top and bottom of the cell. We define the ratio of the velocity of the downward- to the upward-streaming cytoplasm as the polar ratio (PR). The normal polarity of a cell can be reversed (PR < 1) by treatment with neutral red (NR). The NR effect may be the result of membrane hyperpolarization, caused by the opening of K+ channels. The K+ channel blocker TEA Cl- inhibits the NR effect. External Ca2+ is required for normal graviresponsiveness. The [Ca2+] of the medium determines the polarity of cytoplasmic streaming. Less than 1 micromole Ca2+ resulted in a PR < 1 while greater than 1 micromole Ca2+ resulted in the normal gravity response. The voltage-dependent Ca(2+)-channel blocker, nifedipine, inhibited the gravity response in a reversible manner, while treatment with LaCl3 resulted in a PR < 1, indicating the presence of two types of Ca2+ channels. A new model for graviperception is presented in which the whole cell acts as the gravity sensor, and the plasma membrane acts as the gravireceptor. This is supported by ligation and UV irradiation experiments which indicate that the membranes at both ends of the cell are required for graviperception. The density of the external medium also affects the PR of Nitellopsis. Calculations are presented that indicate that the weight of the protoplasm may provide enough potential energy to open ion channels.

NASA Discipline Plant Biology↗

Photonuclear cross sections for 197 Au: An update on the gold standard

Cross sections for the 197 Au(γ, n) reaction are broadly used in nuclear physics as a standard for normalizing photonuclear reaction cross-section data at photon beam energies above approximately 8 MeV. In this paper, we report cross-section measurements for the 197 Au(γ, n) 196 Au g+m1 reaction at beam energies from 13 to 31 MeV. Our measurements provide the first cross-section data for this reaction at beam energies above 20 MeV, enabling the use of this reaction as a cross-section standard up to 30 MeV. Also, this work provides first cross-section measurements for the 197 Au(γ, n) 196 Au m2 reaction. In addition, we measured cross-section data for the 197 Au(γ, 3n) 194 Au reaction, which can be used as a cross-section standard above about 25 MeV. These measurements were performed using a new target activation method that is based on the angle-energy correlation of the laser Compton- scattered photon beams at the High Intensity Gamma-ray Source (HIγS). The technique enables measuring photonuclear reaction cross-sections at several discrete beam energies concurrently via a single irradiation on a stack of different targets. Measurements were carried out by irradiating a stack of concentric-ring targets consisting of Au, TiO 2 , Zn, Os, and Au (in order of the γ-ray beam direction). Our data for the 197 Au(γ,n) 196 Au g+m1 reaction in the energy range of 13 to 20 MeV are in good agreement with existing ones measured using monoenergetic γ-ray beams, but differ from data acquired using a bremsstrahlung γ-ray beam. Also, above 18 MeV, our data for the 197 Au(γ,n) 196 Au g+m1 and 197 Au(γ,n) 196 Au m2 reactions differ significantly from the most recent TENDL and JENDL evaluations, suggesting a need to update these data libraries. Furthermore, the TENDL evaluation and existing data are consistent with our data for the 197 Au(γ,3n) reaction, but differ significantly from the JENDL evaluation above 26 MeV.

190 ≤ A ≤ 219↗

Engineering a modular 44 Ti/ 44 Sc generator: eluate evaluation in preclinical models and estimation of human radiation dosimetry

Background: 44 Sc/ 47 Sc is an attractive theranostic pair for targeted in vivo positron emission tomographic (PET) imaging and beta-particle treatment of cancer. The 44 Ti/ 44 Sc generator allows daily onsite production of this diagnostic isotope, which may provide an attractive alternative for PET facilities that lack in-house irradiation capabilities. Early animal and patient studies have demonstrated the utility of 44 Sc. In our current study, we built and evaluated a novel clinical-scale 44 Ti/ 44 Sc generator, explored the pharmacokinetic profiles of 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA (1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid) in naïve mice, and estimated the radiation burden of 44 ScCl 3 in humans. Methods: 44 Ti/ 44 Sc (101.2 MBq) in 6 M HCl solution was utilized to assemble a modular ZR resin containing generator. After assembly, 44 Sc was eluted with 0.05 M HCl for further PET imaging and biodistribution studies in female Swiss Webster mice. Based on the biodistribution data, absorbed doses of 44 / 47 ScCl 3 in human adults were calculated for 18 organs and tissues using the IDAC-Dose software. Results: 44 Ti in 6 M HCl was loaded onto the organic resin generator with a yield of 99.97%. After loading and initial stabilization, 44 ScCl 3 was eluted with 0.05 M HCl in typical yields of 82.9 ± 5.3% (N = 16), which was normalized to the estimated generator capacity. Estimated generator capacity was computed based on elution time interval and the total amount of 44 Ti loaded on the generator. Run in forward and reverse directions, the 44 Sc/ 44 Ti ratio from a primary column was significantly improved from 1038 ± 440 to 3557 ± 680 (Bq/Bq) when a secondary, replaceable, ZR resin cartridge was employed at the flow outlet. In vivo imaging and ex vivo distribution studies of the reversible modular generator for 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA show that free 44 Sc remained in the circulation significantly longer than the chelated 44 Sc. The dose estimation of 44 ScCl 3 reveals that the radiation burden is 0.146 mSv/MBq for a 70 kg adult male and 0.179 mSv/MBq for a 57 kg adult female. Liver, spleen and heart wall will receive the highest absorbed dose: 0.524, 0.502, and 0.303 mGy/MBq, respectively, for the adult male. Conclusions: A clinical-scale 44 Ti/ 44 Sc generator system with a modular design was developed to supply 44 ScCl 3 in 0.05 M HCl, which is suitable for further radiolabeling and in vivo use. Our data demonstrated that free 44 ScCl 3 remained in the circulation for extended periods, which resulted in approximately 10 times greater radiation burden than stably chelated 44 Sc. Stable 44 Sc/ 47 Sc-complexation will be more favorable for in vivo use and for clinical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High average-flux laser-driven neutron source

Laser-driven neutron generation is an attractive alternative to more established methods for compact, short-pulse-duration neutron sources with applications in medical science, material science and imaging. Despite extensive investigation of various techniques, achieving performance comparable to nuclear reactors or conventional accelerators remains challenging. In this work, we generate a stable, high-repetition-rate laser-driven neutron source reaching a record average flux of 7.8 × 10 7 n/sr/s, improving on other existing laser-based sources by more than one order of magnitude. Our approach is based on a two-step process where electrons are accelerated to relativistic energies via laser wakefield acceleration (LWFA), and subsequently generate neutrons through Bremsstrahlung emission followed by photonuclear reactions in a tungsten converter. Experimental results, supported by Monte Carlo simulations, show a neutron flux of 3.0 × 10 7 n/cm 2 /s near the target, on par with some compact accelerator-based neutron sources. Additionally, a direct comparison with the target-normal sheath acceleration (TNSA) pitcher-catcher scheme, performed on the same laser system, reveals a significantly higher total neutron yield of 3.9 × 10 8 neutrons per shot, outperforming the TNSA scheme by several orders of magnitude. These findings represent a significant advancement towards the development of practical laser-driven neutron sources and highlight the advantages of LWFA-based neutron generation for future applications.

Vallières, Simon [Institut National de la Recherch↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

Software For Advanced Large-scale Analysis Of Magnetic Confinement For Numerical Design, Engineering & Research (salamander)

As magnetic confinement fusion energy gains traction internationally to enable abundant energy production, designing components for fusion systems is a pressing challenge. During the planned lifetime of a fusion device, components evolve in extreme environments and must withstand large, repeated thermal loads and bombardment by 14 MeV neutrons, plasma ions, and neutral particles (deuterium, tritium, and helium), corrosive conditions, etc. All these physical processes take place simultaneously, interact in intricate ways, and impose important constraints that can affect performance. Experimental data is rare and costly to obtain, making design particularly challenging. Predictive computational frameworks must be an integral part of an accelerated and cost-effective design process by modeling fusion system performance in simulated environments. To better understand component degradation and operational impacts on their performance, the Software for Advanced Large-scale Analysis of MAgnetic confinement for Numerical Design, Engineering & Research (SALAMANDER) is designed as an open-source, fully integrated, multiphysics, multiscale, NQA-1 compliant framework facilitating 3D, high-fidelity fusion system modeling. To that end, SALAMANDER is a MOOSE-based framework, and therefore leverages MOOSE upstream libraries such as PETSc and libMesh to deliver sophisticated finite element, finite volume, and nonlinear solver technology for fusion energy simulations. SALAMANDER couples MOOSE physics module capabilities—such as thermal hydraulics, heat conduction, Navier-Stokes, and thermomechanics—with tritium transport via TMAP8, neutronics via Cardinal, and nascent particle-in-cell capabilities. Direct simulation Monte Carlo methods will be used to address neutral transport near the walls. By coupling all these physics in an integrated application, SALAMANDER will enable high-fidelity modeling of irradiation levels and plasma exposure conditions of plasma facing components and their impact on heat and tritium distributions, as well as the resulting mechanical constraints experienced by the plasma facing components and performance of blanket systems. Furthermore, SALAMANDER will be particularly suited for engineering studies thanks to the stochastic tool module readily available in MOOSE, allowing for extended uncertainty quantification and risk analysis studies. It is also able to use computer-aided design (CAD) meshes to model complex geometries, which is indispensable for fusion systems. SALAMANDER therefore supports design, safety, engineering, and research projects for magnetic confinement fusion systems

Simon, Pierre-Clement [Idaho National Laboratory (↗