Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Beyond traditional diagnostics: Identifying active galactic nuclei using spectral energy distribution fitting in DESI data

Active galactic nuclei (AGN) are typically identified through their distinctive X-ray or radio emissions, mid-infrared (MIR) colors, or emission lines. However, each method captures different subsets of AGN due to signal-to-noise (S/N) limitations, redshift coverage, and extinction effects, underscoring the necessity for a multiwavelength approach for comprehensive AGN samples. This study explores the effectiveness of spectral energy distribution (SED) fitting as a robust method for AGN identification. Using CIGALE optical-MIR SED fits on DESI Early Data Release galaxies, we compare SED-based AGN selection (AGNFRAC ≥ 0.1) with traditional methods including BPT diagrams, WISE colors, X-ray, and radio diagnostics. The SED fitting identifies ∼70% of narrow- and broad-line AGN and 87% of WISE-selected AGN. Incorporating high S/N WISE photometry reduces star-forming galaxy contamination from 62% to 15%. Initially, ∼50% of SED-AGN candidates are undetected by standard methods, but additional diagnostics classify ∼85% of these sources, revealing low-ionization nuclear emission-line regions and retired galaxies potentially representing evolved systems with weak AGN activity. Further spectroscopic and multiwavelength analysis will be essential to determine the true AGN nature of these sources. SED fitting provides complementary AGN identification, unifying multiwavelength AGN selections. This approach enables more complete – albeit somewhat contaminated – AGN samples, which are essential for upcoming large-scale surveys where spectroscopic diagnostics may be limited.

Seyfert↗

Three-dimensional diagnostics and measurements of inertial confinement fusion plasmas

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium–tritium plasma undergoing fusion (“hotspot”), v HS . Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide v HS to better than 1 part in 10 4 and enable cross correlations with other measurements. Here we present the impact of v HS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

47 OTHER INSTRUMENTATION↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Diagnostics of plasma–liquids systems: Challenges and their mitigation

This article will review two popular methods of laser diagnostics in a plasma–liquid system and generally in low-temperature plasmas. These are Thomson scattering and laser-induced fluorescence. Setting up the plasma–liquid interaction experiment will be described while stressing the important points for laser diagnostics and maintaining conditions for correct and repeatable measurements. In this work, I will discuss the caveats that are encountered when measuring an inherently unstable and collisional system, such as plasma interacting with the liquid and how these challenges impact that data analysis and calibration efforts for these two-diagnostic approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ~2.5 cm (FWHM) and an effective time resolution of ~1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. In conclusion, the upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Plasma confinement state classification via FPP relevant microwave diagnostics

We present a parsimonious and robust machine learning approach for identifying plasma confinement states in fusion power plants (FPPs) where reliable identification of the low-confinement and high-confinement regimes is critical for safe and efficient operation. Unlike research-oriented devices, FPPs must operate with a severely constrained set of diagnostics. To address this challenge, we demonstrate that a minimalist model, using only electron cyclotron emission (ECE) signals, can achieve accurate and reliable state classification. ECE provides electron temperature profiles without the engineering or survivability issues of in-vessel probes, making it a primary candidate for FPP-relevant diagnostics. Our framework employs ECE as input, extracts features using radial basis functions, and applies a gradient boosting classifier, achieving a test accuracy of 96% (correct predictions). Robustness analysis and feature importance analyzes confirm the approach’s reliability. These results demonstrate that state-of-the-art performance is attainable from a restricted diagnostic set, paving the way for minimalist yet resilient plasma control architectures for FPPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation modeling and experimental validation of sub-cyclotron frequency microwave synchrotron radiation as a diagnostic tool for runaway electrons in present and future tokamaks

The microwave synchrotron radiation in the sub-cyclotron frequency region has been systematically validated as a diagnostic method for runaway electrons (>1 MeV) with radiation modeling and experiments on the DIII-D tokamak. Experimental observations reveal that sub-cyclotron frequency microwave radiation emerges only after runaway electrons are excited during plasma disruptions. Electron gyro-magnetic radiation modeling confirms that only runaway electrons with energies exceeding 1 MeV can emit radiation in the observed sub-cyclotron frequency band on DIII-D. The synchrotron Razin and Beaming effects are modeled in both the sub-cyclotron and standard Electron Cyclotron Emission (ECE) frequency region. Due to the pronounced beaming effect, the modeling supports that a standard ECE system is insensitive to synchrotron radiation from beamed runaway electrons (p ∥ >> p ⟂ ), but very sensitive to ECE radiation from isotropic suprathermal electrons (100 keV or less). DIII-D experiments further show that combining ECE and sub-cyclotron receivers reveals new insights into transient runaway dynamics during the plateau phase. Certain transient crash events appear only in the sub-cyclotron band or lead to opposite changes on the sub-cyclotron and standard ECE signals, supporting models where transient MHD events can exert a different effect on electrons of different energy levels. This novel diagnostic technique offers a powerful tool for studying and detecting runaway electron dynamics in both present-day and high-field future tokamaks. The diagnostic approach has been extrapolated to the SPARC tokamak, where sub-cyclotron radiation is predicted to respond sensitively and solely to runaway electrons during SPARC’s L-mode startup phase.

Yu, Guanying [Hefei Comprehensive National Science↗

Wakefield generation in hydrogen and lithium plasmas at FACET-II: Diagnostics and first beam-plasma interaction results

Plasma wakefield acceleration provides ultrahigh acceleration gradients of tens of GeV/m, providing a novel path toward efficient, compact, TeV-scale linear colliders, and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single-stage plasma wakefield accelerator, providing a 10 GeV energy gain in a < 1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm mrad accuracy, energy spectra to determine both percent level energy spread, and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed as well as commissioning of the plasma sources and diagnostics. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Spatial-Temporal Recurrent Graph Neural Networks for Fault Diagnostics in Power Distribution Systems

Fault diagnostics are extremely important to decide proper actions toward fault isolation and system restoration. The growing integration of inverter-based distributed energy resources imposes strong influences on fault detection using traditional overcurrent relays. This paper utilizes emerging graph learning techniques to build new temporal recurrent graph neural network models for fault diagnostics. The temporal recurrent graph neural network structures can extract the spatial-temporal features from data of voltage measurement units installed at the critical buses. From these features, fault event detection, fault type/phase classification, and fault location are performed. Compared with previous works, the proposed temporal recurrent graph neural networks provide a better generalization for fault diagnostics. Moreover, the proposed scheme retrieves the voltage signals instead of current signals so that there is no need to install relays at all lines of the distribution system. Therefore, the proposed scheme is generalizable and not limited by the number of relays installed. The effectiveness of the proposed method is comprehensively evaluated on the Potsdam microgrid and IEEE 123-node system in comparison with other neural network structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Upgrades to the Thomson Scattering Diagnostic on the Lithium Tokamak eXperiment-Beta (LTX-$β$)

We describe the upgrades to the Thomson scattering (TS) diagnostic on the Lithium Tokamak eXperiment-beta (LTX- β ) to provide complete radial coverage of the plasma. LTX- β is a spherical tokamak with plasma limited at a major radius of R = 14 cm and R = 66 cm. Flat temperature profiles with peaked density were observed in LTX- β using an existing multipoint TS diagnostic with radial coverage of the plasma core. There is a need for more comprehensive core and edge TS measurements to thoroughly examine beam fueling, beam heating, and transport under low recycling conditions with liquid lithium walls and a lower collisionality scrape-off layer (SOL). The core TS set up provides plasma profiles from R = 40–60 cm. To extend the TS diagnostic coverage: 1) we added a TS viewing optics to cover the SOL region at five radial points from R = 57–64 cm, and 2) another TS viewing optics in the HFS region from R = 15–45 cm to obtain TS data from ten radial positions while making use of the original laser beam. The main focus of this article is on the new HFS TS setup that is equipped with better-matched collection optics located in the horizontal midplane where the laser polarization lies and views from a scattering angle of 130°–150° with respect to the laser path. A set of unequal-length Y-branched fiber bundles transports the TS light from two radial points to each polychromator. The new HFS view is better matched in spot size, scattering angle, and throughput to the laser and polychromators and has new V-grooved style viewing dumps. The new HFS TS view, along with the core and SOL TS views, will provide a full radial measurement coverage from R = 15–64 cm to explore the flat temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

elm-diagnostics

elm-diagnostics is a Python package for computing diagnostic analyses and visualizations for the E3SM Land Model (ELM) component and is meant to support new feature development in ELM. The tool reads model history files and performs quantitative analyses including budget-closure checking, variable transformations, temporal aggregations, and statistical summaries to support model evaluation, validation, and scientific interpretation. The framework is designed for extensibility, with modular architecture enabling straightforward addition of new diagnostic methods, derived variables, analysis types, visualization approaches, and model-specific adaptations

Hoffman, Matt [Los Alamos National Laboratory]↗

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗

Fast Evaluation of Viral Emerging Risks (FEVER): A computational tool for biosurveillance, diagnostics, and mutation typing of emerging viral pathogens

Viral pathogens can rapidly evolve, adapt to novel hosts, and evade human immunity. The early detection of emerging viral pathogens through biosurveillance coupled with rapid and accurate diagnostics are required to mitigate global pandemics. However, RNA viruses can mutate rapidly, hampering biosurveillance and diagnostic efforts. Here, we present a novel computational approach called FEVER (Fast Evaluation of Viral Emerging Risks) to design assays that simultaneously accomplish: 1) broad-coverage biosurveillance of an entire group of viruses, 2) accurate diagnosis of an outbreak strain, and 3) mutation typing to detect variants of public health importance. We demonstrate the application of FEVER to generate assays to simultaneously 1) detect sarbecoviruses for biosurveillance; 2) diagnose infections specifically caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); and 3) perform rapid mutation typing of the D614G SARS-CoV-2 spike variant associated with increased pathogen transmissibility. These FEVER assays had a high in silico recall (predicted positive) up to 99.7% of 525,708 SARS-CoV-2 sequences analyzed and displayed sensitivities and specificities as high as 92.4% and 100% respectively when validated in 100 clinical samples. The D614G SARS-CoV-2 spike mutation PCR test was able to identify the single nucleotide identity at position 23,403 in the viral genome of 96.6% SARS-CoV-2 positive samples without the need for sequencing. This study demonstrates the utility of FEVER to design assays for biosurveillance, diagnostics, and mutation typing to rapidly detect, track, and mitigate future outbreaks and pandemics caused by emerging viruses.

59 BASIC BIOLOGICAL SCIENCES↗

HFTS-2 Completions Design and State-of-the-Art Diagnostics Results

Various completion schemes were tested as part of the Hydraulic Fracture Test Site-2 (HFTS-2) project. The wells were instrumented with permanent fiber optic (FO) cable, and unique near-wellbore and far-field region surveys were acquired to evaluate spatial and temporal hydraulic fracture characteristics. The state-of-the-art diagnostics included substantial monitoring of both the well stimulation and longer-term production performance. The objective was to evaluate and improve stimulation distribution effectiveness (SDE) for different completion designs based on the diagnostics results. A hydraulic fracturing (HF) profile (i.e., proppant/fluid allocation among clusters) was obtained using near-wellbore Distributed Acoustic Sensing (DAS) data acquired during stimulation. Statistical analysis provided a quantitative assessment of SDE for the different completion designs. A novel workflow was developed to assess time-lapse fracture property changes at the cluster and stage levels based on Distributed Strain Sensing (DSS) data acquired during the production phase. These time-lapse fracture property changes were compared with the HF profile. Based on the statistical analysis, Rate Per Cluster (RPC) during proppant slurry placement appears to be a primary completion design variable, rather than the typical Rate Per Perf (RPP). If RPC was not maintained at a certain level, the likelihood of uneven distribution increased dramatically. The stage configurations that created low RPC while maintaining high RPP did not show improved SDE. The strain change results based on DSS data during the production phase indicated near-wellbore fracture property changes (e.g., aperture changes during well shut-in and flow periods) and aligned well with near-wellbore DAS signals acquired during stimulation. More importantly, fracture property changes based on DSS data acquired during two tests over a 7-month period show high consistency and good alignment with the near-wellbore HF profile. This workflow quantitatively evaluates SDE for different completion designs using diagnostic results and could help optimize completion strategy for future development projects. Here, the analysis and interpretation of results demonstrate the technical feasibility of using permanent fiber optic cable for stimulation and production monitoring and indic

58 GEOSCIENCES↗