Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Automated inspection of wire-frame assemblies

System improves accuracy of measurement between spaces of wire mesh and other wire frame assemblies while significantly reducing inspection time. Device operates automatically producing printout of measured spacings through use of optical scanner.

Etzel, J. G.↗

A study to investigate the chemical stability of gallium phosphate oxide/gallium arsenide phosphide

The elemental composition with depth into the oxide films was examined using secondary ion mass spectrometry. Results indicate that the layers are arsenic-deficient through the bulk of the oxide and arsenic-rich near both the oxide surface and the oxide-semiconductor interface region. Phosphorus is incorporated into the oxide in an approximately uniform manner. The MIS capacitor structures exhibited deep-depletion characteristics and hysteresis indicative of electron trapping at the oxide-semiconductor interface. Post-oxidation annealing of the films in argon or nitrogen generally results in slightly increased dielectric leakage currents and decreased C-V hysteresis effects, and is associated with arsenic loss at the oxide surface. The results of bias-temperature stress experiments indicate that the major instability effects are due to changes in the electron trapping behavior. No changes were observed in the elemental profiles following electrical stressing, indicating that the grown films are chemically stable under device operating conditions.

Kuhlman, G. J.↗

long wavelength Pb(1-x)Sn(X)Se and Pb(1-x)Sn(x)Te diode lasers as local oscillators

A breadboard heterodyne receiver is described which was used to establish the characteristics of lead salt diode lasers pertinent to their use as local oscillators using laser devices operating in the 15-25 micrometer spectral region. Heterodyne detection efficiency is directly correlated with the transverse mode structure and emphasizes the necessity of stable lowest order mode operation for lasers when used as local oscillators. The results obtained indicate that the continued development of these lasers provide suitable local oscillators for a variety of applications.

Washwell, E. R.↗

Thermodynamic limits for solar energy conversion by a quantum-thermal hybrid system

The limits are presented fo air mass 1.5 conditions. A maximum conversion efficiency of 74 percent is thermodynamically achievable for the quantum device operating at 3500 K and the heat engine in contact with a reservoir at 0 K. The efficiency drops to 56 percent for a cold reservoir at approximately room temperature conditions. Hybrid system efficiencies exceed 50 percent over receiver temperatures ranging from 1400 K to 4000 K, suggesting little benefit is gained in operating the system above 1400 K. The results are applied to a system consisting of a photovoltaic solar cell in series with a heat engine.

Byvik, C. E.↗

Hemispherical-field-of-view, nonimaging narrow-band spectral filter

Two compound parabolic concentrators are used to create a 180-deg-field-of-view spectral filter. The collection optics are reflective and are designed to collimate the light through a multilayer interference filter and then to refocus it onto an optical detector. Assuming unit reflectance and no loss through the optical filter, this device operates at the thermodynamic collection limit.

Miles, R. B.↗

Electron-bombarded CCD detectors for ultraviolet atmospheric remote sensing

Electronic image sensors based on charge coupled devices operated in electron-bombarded mode, yielding real-time, remote-readout, photon-limited UV imaging capability are being developed. The sensors also incorporate fast-focal-ratio Schmidt optics and opaque photocathodes, giving nearly the ultimate possible diffuse-source sensitivity. They can be used for direct imagery of atmospheric emission phenomena, and for imaging spectrography with moderate spatial and spectral resolution. The current state of instrument development, laboratory results, planned future developments and proposed applications of the sensors in space flight instrumentation is described.

Carruthers, G. R.↗

Solder Bonding for Power Transistors

Indium solder boosts power rating and facilitates circuit changes. Efficient heat conduction from power transistor to heat sink provided by layer of indium solder. Low melting point of indium solder (141 degrees C) allows power transistor to be removed, if circuit must be reworked, without disturbing other components mounted with ordinary solder that melts at 181 degrees C. Solder allows devices operated at higher power levels than does conventional attachment by screws.

Snytsheuvel, H. A.↗

Capture of liquid hydrogen boiloff with metal hydride absorbers

A procedure which uses metal hydrides to capture some of this low pressure (,1 psig) hydrogen for subsequent reliquefaction is described. Of the five normally occurring sources of boil-off vapor the stream associated with the off-loading of liquid tankers during dewar refill was identified as the most cost effective and readily recoverable. The design, fabrication and testing of a proof-of-concept capture device, operating at a rate that is commensurate with the evolution of vapor by the target stream, is described. Liberation of the captured hydrogen gas at pressure .15 psig at normal temperatures (typical liquefier compressor suction pressure) are also demonstrated. A payback time of less than three years is projected.

Rosso, M. J.↗

Compact acoustic levitation device for studies in fluid dynamics and material science in the laboratory and microgravity

An ultrasonic levitation device operable in both ordinary ground-based as well as in potential space-borne laboratories is described together with its various applications in the fields of fluid dynamics, material science, and light scattering. Some of the phenomena which can be studied by this instrument include surface waves on freely suspended liquids, the variations of the surface tension with temperature and contamination, the deep undercooling of materials with the temperature variations of their density and viscosity, and finally some of the optical diffraction properties of transparent substances.

Trinh, E. H.↗

High-Voltage Switch Containing (DI)2 Devices

Series switching diodes triggered on by passing above threshold voltage. High-voltage switch made by connecting multitude of deep-impurity, double-injection devices in series with each other and with another, triggerable high-voltage device such as thyristor. Device operates near ground potential to avoid insulation problems in triggering circuit.

Hanes, Maurice H.↗

OH radical measurements by optical absorption spectroscopy

The long path absorption spectroscopy (LPA) measurement of OH utilizes the strong UV absorption spectrum of the molecule with well resolved rotational lines around 308 nm. The light source consists of an Ar ion laser pumped CW dye laser, the output of which is frequency doubled to emit a spectrally smooth light profile of 0.1 nm FWHM at 308 nm. This is considerably broader than the sharp (0.0018 nm wide) absorption features of OH and also wider than the total spectral region (0.06 nm) scanned around the OH lines. For field measurements a Cassegrain-type telescope expands the small diameter of the original laser beam by a factor of 50 to about a 0.25-m diameter in order to reduce the divergence of the beam as well as its mean photon flux density, thus reducing the maximum self-generated OH concentration to 40,000 cu. cm. The light is passed into the open atmosphere and reflected at about 5 km distance resulting in a 10-km light path length. A telescope focuses the returning light onto the entrance slit of a monochromator the single exit slit of which is replaced by a mechanical scanning device operating at a scan repetition rate of 6.6 KHz. For a typical measurement (1h duration) some 20,000,000 scans are averaged, rendering the contribution of atmospheric turbulence to the spectral noise negligible.

Platt, U.↗

Ultra small electron beam amplifiers

Data on field emission and microfabrication technologies relevant to the development of low-power electron-beam amplifiers and oscillators are discussed. The fabrication of a thin-film field-emission (TFFE) cathode for a 1-W electron-beam amplifier is examined. Some TFFE cathodes have been developed and tested in electron guns. Recent experimental results reveal that a beam can be formed from the field-emission cathode, and the TFFE cathode is applicable for devices operating below 3 kV at currents of less than 20 mA. The use of microfabrication techniques to construct slow-wave circuits is studied, and the use of finned structures as the slow-wave circuit for an electron-beam oscillator or amplifier is proposed.

Dayton, J. A., Jr.↗

Data storage systems technology for the Space Station era

The paper presents the results of an internal NASA study to determine if economically feasible data storage solutions are likely to be available to support the ground data transport segment of the Space Station mission. An internal NASA effort to prototype a portion of the required ground data processing system is outlined. It is concluded that the requirements for all ground data storage functions can be met with commercial disk and tape drives assuming conservative technology improvements and that, to meet Space Station data rates with commercial technology, the data will have to be distributed over multiple devices operating in parallel and in a sustained maximum throughput mode.

Dalton, John↗

Monolithic microwave integrated circuit technology for advanced space communication

Future Space Communications subsystems will utilize GaAs Monolithic Microwave Integrated Circuits (MMIC's) to reduce volume, weight, and cost and to enhance system reliability. Recent advances in GaAs MMIC technology have led to high-performance devices which show promise for insertion into these next generation systems. The status and development of a number of these devices operating from Ku through Ka band will be discussed along with anticipated potential applications.

Ponchak, George E.↗

A design methodology for neutral buoyancy simulation of space operations

Neutral buoyancy has often been used in the past for EVA development activities, but little has been done to provide an analytical understanding of the environment and its correlation with space. This paper covers a set of related research topics at the MIT Space Systems Laboratory, dealing with the modeling of the space and underwater environments, validation of the models through testing in neutral buoyancy, parabolic flight, and space flight experiments, and applications of the models to gain a better design methodology for creating meaningful neutral buoyancy simulations. Examples covered include simulation validation criteria for human body dynamics, and for applied torques in a beam rotation task, which is the pacing crew operation for EVA structural assembly. Extensions of the dynamics models are presented for powered vehicles in the underwater environment, and examples given from the MIT Space Telerobotics Research Program, including the Beam Assembly Teleoperator and the Multimode Proximity Operations Device. Future expansions of the modeling theory are also presented, leading to remote vehicles which behave in neutral buoyancy exactly as the modeled system would in space.

Akin, David L.↗

Mass spectrometer for measurements of relative ion concentrations in plasmas

A mass spectrometer which can be used to measure relative ion concentrations in a multiion component plasma has been designed for use in a strong (1-4-kG) uniform magnetic field. The spectrometer features an acceleration region which accelerates thermal ions through a series of three tantalum electrodes at a 30 deg angle to the B field, and a collection region in which ions are selectively collected, depending on the size of their gyroradii, by a cylindrical collector. Relative ion concentrations are determined from measurements of the collector current as a function of accelerating voltage. Results obtained using this instrument in a Q-machine device operated with a two-ion (Cs+/K+) component plasma are presented.

Suszcynsky, David M.↗

Making Internal Molds Of Long, Curved Tubes

Mold material carried to internal weld joint and removed after impression taken. Remotely operated device makes impression mold of interior surface of tube at weld joint. Mold provides indication of extent of mismatch between members at joint. Maneuvered to weld inspected through curved tube 3 in. in diameter by 50 in. long. Readily adapted to making molds to measure depth of corrosion in boiler tubes or other pipes.

Burley, Richard K.↗