Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

TU-H-CAMPUS-IeP1-01: Bias and Computational Efficiency of Variance Reduction Methods for the Monte Carlo Simulation of Imaging Detectors

Purpose: Variance reduction techniques (VRTs) are employed in Monte Carlo simulations to obtain estimates with reduced statistical uncertainty for a given simulation time. In this work, we study the bias and efficiency of a VRT for estimating the response of imaging detectors. Methods: We implemented Directed Sampling (DS), preferentially directing a fraction of emitted optical photons directly towards the detector by altering the isotropic model. The weight of each optical photon is appropriately modified to maintain simulation estimates unbiased. We use a Monte Carlo tool called fastDETECT2 (part of the hybridMANTIS open-source package) for optical transport, modified for VRT. The weight of each photon is calculated as the ratio of original probability (no VRT) and the new probability for a particular direction. For our analysis of bias and efficiency, we use pulse height spectra, point response functions, and Swank factors. We obtain results for a variety of cases including analog (no VRT, isotropic distribution), and DS with 0.2 and 0.8 optical photons directed towards the sensor plane. We used 10,000, 25-keV primaries. Results: The Swank factor for all cases in our simplified model converged fast (within the first 100 primaries) to a stable value of 0.9. The root mean square error per pixel for DS VRT for the point response function between analog and VRT cases was approximately 5e-4. Conclusion: Our preliminary results suggest that DS VRT does not affect the estimate of the mean for the Swank factor. Our findings indicate that it may be possible to design VRTs for imaging detector simulations to increase computational efficiency without introducing bias.

60 APPLIED LIFE SCIENCES↗

Generative machine learning for detector response modeling with a conditional normalizing flow

In this paper, we explore the potential of generative machine learning models as an alternative to the computationally expensive Monte Carlo (MC) simulations commonly used by the Large Hadron Collider (LHC) experiments. Our objective is to develop a generative model capable of efficiently simulating detector responses for specific particle observables, focusing on the correlations between detector responses of different particles in the same event and accommodating asymmetric detector responses. Here, we present a conditional normalizing flow model ($\mathcal{CNF}$) based on a chain of Masked Autoregressive Flows, which effectively incorporates conditional variables and models high-dimensional density distributions. We assess the performance of the $\mathcal{CNF}$ model using a simulated sample of Higgs boson decaying to diphoton events at the LHC. We create reconstruction-level observables using a smearing technique. We show that conditional normalizing flows can accurately model complex detector responses and their correlation. This method can potentially reduce the computational burden associated with generating large numbers of simulated events while ensuring that the generated events meet the requirements for data analyses. We make our code available at https://github.com/allixu/normalizing_flow_for_detector_response

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ratpac-Two v1.0.0

Geant-4 based detector simulations in c++ which combines simulation and analysis into a single framework to precisely model detector components and analyze experimental data. Ratpac allows the user to easily build new detector geometries and configurations through both the source library and through configurable text files at runtime.

Askins, Morgan↗

Calibration and optimization of proportional counter modules using Garfield

Prototypes of radiation detector arrays used for charged-particle radiography require iniliol calibration to correlate the distribution of electron arrival time to the particle track locations. This step is crucial to obtaining the spatial resolution necessary to separate particle tracks traversing the individual proportional counters in the arrays. Our past attempts to use cosmic rays alone for the initial calibration have fallen short of obtaining the desired resolution due to the insufficient cosmic ray flux to provide the necessary number of particle tracks. A theoretical relation between electron drift time and radial drift distance is obtained with Garfield, a CERN gas detector simulation program. This relation is then used as an effective starting point for the initial calibration and results in a shorter calibration period and improved spatial resolution of the detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CompF2: Theoretical Calculations and Simulation Topical Group Report

This report summarizes the work of the Computational Frontier topical group on theoretical calculations and simulation for Snowmass 2021. We discuss the challenges, potential solutions, and needs facing six diverse but related topical areas that span the subject of theoretical calculations and simulation in high energy physics (HEP): cosmic calculations, particle accelerator modeling, detector simulation, event generators, perturbative calculations, and lattice QCD (quantum chromodynamics). The challenges arise from the next generations of HEP experiments, which will include more complex instruments, provide larger data volumes, and perform more precise measurements. Calculations and simulations will need to keep up with these increased requirements. The other aspect of the challenge is the evolution of computing landscape away from general-purpose computing on CPUs and toward special-purpose accelerators and coprocessors such as GPUs and FPGAs. These newer devices can provide substantial improvements for certain categories of algorithms, at the expense of more specialized programming and memory and data access patterns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unifying simulation and inference with normalizing flows

There have been many applications of deep neural networks to detector calibrations and a growing number of studies that propose deep generative models as automated fast detector simulators. We show that these two tasks can be unified by using maximum likelihood estimation (MLE) from conditional generative models for energy regression. Unlike direct regression techniques, the MLE approach is prior independent and non-Gaussian resolutions can be determined from the shape of the likelihood near the maximum. Using an ATLAS-like calorimeter simulation, we demonstrate this concept in the context of calorimeter energy calibration. Published by the American Physical Society 2025

Hadronic calorimiters↗

Stochastic optimization of GeantV code by use of genetic algorithms

GeantV is a complex system based on the interaction of different modules needed for detector simulation, which include transport of particles in fields, physics models simulating their interactions with matter and a geometrical modeler library for describing the detector and locating the particles and computing the path length to the current volume boundary. The GeantV project is recasting the classical simulation approach to get maximum benefit from SIMD/MIMD computational architectures and highly massive parallel systems. This involves finding the appropriate balance between several aspects influencing computational performance (floating-point performance, usage of off-chip memory bandwidth, specification of cache hierarchy, etc.) and handling a large number of program parameters that have to be optimized to achieve the best simulation throughput. This optimization task can be treated as a black-box optimization problem, which requires searching the optimum set of parameters using only point-wise function evaluations. Here, the goal of this study is to provide a mechanism for optimizing complex systems (high energy physics particle transport simulations) with the help of genetic algorithms and evolution strategies as tuning procedures for massive parallel simulations. One of the described approaches is based on introducing a specific multivariate analysis operator that could be used in case of resource expensive or time consuming evaluations of fitness functions, in order to speed-up the convergence of the black-box optimization problem.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AI-assisted optimization of the ECCE tracking system at the Electron Ion Collider

The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the “glue” that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5 T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Herein our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for non-standard SUSY signatures in CMS

New studies of the CMS collaboration are presented on the sensitivity to searches for non-standard signatures of particular SUSY scenarios. These signatures include non-pointing photons as well as pairs of prompt photons as expected GMSB SUSY models, as well as heavy stable charged particles produced in split supersymmetry models, long lived staus from GMSB SUSY and long lived stops in other SUSY scenarios. Detailed detector simulation is used for the study, and all relevant Standard Model background and detector effects that can mimic these special signatures are included. It is shown that with already with less than 100 pb{sup -1} the CMS sensitivity will probe an interesting as yet by data unexplored parameter range of these models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

MCNP6 and DRiFT modeling efforts for the NEUANCE/DANCE detector array

This report seeks to study and benchmark code predictions against experimental data; determine parameters to match MCNP-simulated detector response functions to experimental stilbene measurements; add stilbene processing capabilities to DRiFT; and improve NEUANCE detector array modeling and analysis using new MCNP6 and DRiFT features.

47 OTHER INSTRUMENTATION↗

Universal Monte Carlo Event Generator

With the Jefferson Lab 12 GeV physics program underway and plans for the future Electron-Ion Collider (EIC), the nuclear physics community is entering a new era of exploration of QCD phenomena involving extensive data taking and event-level processing. This brings with it the potential for unprecedented access to multidimensional particle momentum distributions (PMDs) that can be connected to various theoretical frameworks by unfolding the emergent quantum mechanical properties of QCD using the PMDs. In practice, the PMDs are rendered as discretized histograms (typically one- or two-dimensional projections), and detector effects must be taken into account to unfold the pure detector effect-free PMDs that can be connected with theory. One of the challenges in this new era is obtaining faithful reconstructions of the multidimensional PMDs that preserve all of the inherent particle correlations. In this LDRD project we developed a novel approach using machine learning (ML) that solves this challenge, by avoiding entirely the need to use histograms as the main numerical technique to obtain the detector effect-free PMDs. The new approach is, moreover, scalable to higher dimensional PMDs. The central idea involves training neural networks (NNs) to generate synthetic event-level data (momenta 4-vectors of final state particles) to preserve all correlations among the particles. This is achieved by converting the trial synthetic vertex-level events to detector-level events using detector simulators. The NNs are then tuned using a specialized distance metric between the synthetic detector events and the real detector events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of neutron multiplicity measurements with MCNP-PoliMi.

The heightened focus on nuclear safeguards and accountability has increased the need to develop and verify simulation tools for modeling these applications. The ability to accurately simulate safeguards techniques, such as neutron multiplicity counting, aids in the design and development of future systems. This work focuses on validating the ability of the Monte Carlo code MCNPX-PoliMi to reproduce measured neutron multiplicity results for a highly multiplicative sample. The benchmark experiment for this validation consists of a 4.5-kg sphere of plutonium metal that was moderated by various thicknesses of polyethylene. The detector system was the nPod, which contains a bank of 15 3He detectors. Simulations of the experiments were compared to the actual measurements and several sources of potential bias in the simulation were evaluated. The analysis included the effects of detector dead time, source-detector distance, density, and adjustments made to the value of {nu}-bar in the data libraries. Based on this analysis it was observed that a 1.14% decrease in the evaluated value of {nu}-bar for 239Pu in the ENDF-VII library substantially improved the accuracy of the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing CP properties of the Higgs boson coupling to τ leptons with heterogeneous graphs

In this paper we explore the possibility of utilizing Deep Learning in measuring the CP properties of the coupling of Higgs boson to τ leptons at the High Luminosity Large Hadron Collider. We employ three Deep Learning (DL) networks, Multi-Layer Perceptron (MLP), Graph Convolution Network (GCN), and Graph Transformer Network (GTN) to enhance signal-to-background separation. The angle between τ lepton decay planes at the detector level is CP-sensitive observables, and we develop Heterogeneous Graphs that integrate diverse node and edge structures to incorporate the CP-sensitive observable efficiently. Using simplified detector simulations we estimate the reconstruction accuracy of the angle between τ lepton planes at the detector level, considering hadronic τ decay modes and standard model backgrounds. With $\sqrt{s}$ = 14 TeV and $\mathcal{L}$ = 100 fb -1 , MLP excludes CP mixing angles above 20° at 68% confidence level (CL), while GCN and GTN achieve exclusions at 90% CL and 95% CL, respectively. The networks also achieve a 3σ significance in excluding a pure CP-odd state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a predictive capability of short-pulse laser-driven broadband x-ray radiography

High intensity, short-pulse laser interaction with a solid metal target produces broadband hard x-rays potentially for various applications of x-ray radiography. In this work, experimental benchmarking of numerical modelling for short-pulse laser-driven broadband x-ray radiography is presented. Angular dependent x-ray spectra are first calculated with a hybrid particle-in-cell code, Large Scale Plasma (LSP), using fast electron parameters inferred from an analysis of measured bremsstrahlung signals. Subsequently, a calculated x-ray spectrum in the direction of radiography is used in photon transport calculations using a Monte Carlo code, Particle and Heavy Ion Transport code System (PHITS), to simulate a radiographic image including a modelled 3D test object, an x-ray attenuation filter and an image plate detector. Simulated radiographic images are compared with measurements obtained in an experiment using a 50-TW Leopard short-pulse laser at the University of Nevada Reno. Results show that simulations reproduce the experimental images well for three different attenuation filters (plastic, aluminium, and brass), while 1D transmission profiles for the plastic and aluminium filters are quantitatively in good agreement. The modelling approach established in this work could be used as a predictive tool to simulate radiographic images of complex 3D solid objects at any arbitrary angular position or to optimize experimental components such as the source spectrum, x-ray attenuation filters and a detector type depending on a radiographic object without carrying out radiographic experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A neural network clustering algorithm for the ATLAS silicon pixel detector

A novel technique to identify and split clusters created by multiple charged particles in the ATLAS pixel detector using a set of artificial neural networks is presented. Such merged clusters are a common feature of tracks originating from highly energetic objects, such as jets. Neural networks are trained using Monte Carlo samples produced with a detailed detector simulation. This technique replaces the former clustering approach based on a connected component analysis and charge interpolation. The performance of the neural network splitting technique is quantified using data from proton-proton collisions at the LHC collected by the ATLAS detector in 2011 and from Monte Carlo simulations. This technique reduces the number of clusters shared between tracks in highly energetic jets by up to a factor of three. It also provides more precise position and error estimates of the clusters in both the transverse and longitudinal impact parameter resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation for Iron Calorimeter prototype detector of India-based Neutrino Observatory

The India-based Neutrino Observatory (INO) collaboration is proposing to build a 50 kton magnetized iron calorimeter (ICAL) detector in an underground laboratory to be located in South India. As a first step towards building the ICAL detector, a 35 ton prototype of the same design has been set up on the surface to track cosmic ray muons. This paper discusses the prototype detector geometry simulation by GEANT4, and the detector response to the cosmic muons. We have developed a track fitting procedure based on the Kalman Filter technique for the prototype detector when the detector is exposed to single muon tracks. The relevant track parameters i.e., momentum, direction and charge are reconstructed and analyzed. Finally we show the resolution of reconstructed momenta.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗