At least 127 records · Page 7

Analysis of observational spectra

The first step in the analysis of gamma ray energy loss spectra is their conversion to differential energy and differential angular photon spectra. This conversion can be carried out if the detector response and the background are both known. Once these parameters are known, there are many techniques that can be used to convert pulse height spectra to photon spectra. These techniques are discussed and background problems are considered. Emphasis is placed on the analysis of energy loss spectra in the lower gamma ray energy domain. Problems of transportations from pulse height to photon space are most complex in this domain and the methods shown illustrate many of the problems which arise in the general analysis of energy loss spectra.

Source record↗

Submillisecond Optical Knife-Edge Testing

Fast computer-controlled sampling of optical knife-edge response (KER) signal increases accuracy of optical system aberration measurement. Submicrosecond-response detectors in optical focal plane convert optical signals to electrical signals converted to digital data, sampled and feed into computer for storage and subsequent analysis. Optical data are virtually free of effects of index-of-refraction gradients.

Thurlow, P.↗

Observations of the galactic center with the GSFC low-energy gamma-ray spectrometer - Preliminary results

The results of measurements made of the gamma ray emission originating from the galactic center are reviewed. The data were gathered with balloon borne gamma ray spectrometers, with the scans centering on 511 keV. Minimum Chi-sq fits were calculated for the recorded emissions, assuming a constant source modulated by the detector response and superimposed on a constant background. A time history of the 511 keV line intensity demonstrated variability in the feature, whereas the continuum spectrum showed a high correlation with previous measurements. An excess in the continuum just below the 511 keV line was taken as an indication of positronium formation.

Paciesas, W. S.↗

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.↗

Recent progress in picosecond pulse generation from semiconductor lasers

This paper reviews the recent progress in producing picosecond optical pulses from semiconductor laser diodes. The discussion concentrates on the mode-locking of a semiconductor laser diode in an external resonator. Transform-limited optical pulses ranging from several picoseconds to subpicosecond durations have been observed with active and passive mode-locking. Even though continuing research on the influence of impurities and defects on the mode-locking process is still needed, this technique has good promise for being utilized in fiber-optic communication systems. Alternative methods of direct electrical and optical excitation to produce ultrashort laser pulses are also described. They can generate pulses of similar widths to those obtained by mode-locking. The pulses generated will find applications in laser ranging and detector response measurement.

Auyeung, J. C.↗

Breadboard stellar tracker system test report

BASD has, in the past, developed several unique position tracking algorithms for charge transfer device (CTD) sensors. These algorithms provide an interpixel transfer function with the following characteristics: (1) high linearity; (2) simplified track logic; (3) high gain; and (4) high noise rejection. A previous test program using the GE charge injection device (CID) showed that accuracy for BASD's breadboard was limited to approximately 2% of a pixel (1 sigma) whereas analysis and simulation indicated the limit should be less than 0.5% of a pixel, assuming the limit to be detector response and dark current noise. The test program was conducted under NASA contract No. NAS8-34263. The test approach for that program did not provide sufficient data to identify the sources of error and left open the amount of contribution from parameters such as image distribution, geometric distortion and system alignment errors.

Kollodge, J. C.↗

The Use of Thematic Mapper Data for Land Cover Discrimination: Preliminary Results from the UK Satmap Programme

In assessing the accuracy of classification techniques for Thematic Mapper data the consistency of the detector-to-detector response is critical. Preliminary studies were undertaken, therefore, to assess the significance of this factor for the TM. The overall structure of the band relationships can be examined by principal component analysis. In order to examine the utility of the Thematic Mapper data more carefully, six different land cover classes approximately Anderson level 1 were selected. These included an area of water from the sediment-laden Mississippi, woodland, agricultural land and urban land. A plume class was also selected which includes the plume of smoke emanating from the power station and drifting over the Mississippi river.

Jackson, M. J.↗

Radiometric analyses of Landsat-4 digital image data

The results of analyses of the radiometric characteristics of digital image data produced by the Landsat 4 MSS and TM sensors are reviewed. The MSS analysis found high quality data comparable to the products of previous Landsats, except for a low-level coherent noise effect having a magnitude of about 0.5 counts in each band and a spatial period of about 3.6 pixels. The TM analysis found excellent spatial resolution, generally high data quality and expected scan-angle effects. Procedures for equalizing detector responses appear to be working as intended. Two low-amplitude artifacts also were discovered. The first is associated with the direction of scan (TM employs bidirectional scanning). The second, a very low employs bidirectional scanning). The second, a very low frequency level-shift artifact which produces image banding that is most pronounced in TM1, could be a serious problem for water-related applications or others where average signal levels are low. Correction procedures are under investigation.

Malila, W. A.↗

Cosmic ray elemental abundances for Z = 26-42 measured on HEAO-3

An analysis is presented of 454 days of data from the Heavy Nuclei Experiment aboard the HEAO-3 satellite using an improved charge estimation algorithm is presented. A more precise normalization of Z = 32-42 abundances relative to iron is obtained, and more accurate detector response maps are used to recognize and reject a small class of events which was previously misidentified. The resulting abundances are in generally good agreement with solar system abundances with the first ionization potential (FIP) and with the Cameron solar system r-process (1982) with and without an applied FIP bias. The simplest interpretation of the results is that the cosmic ray source has solar system abundances modified by an FIP and/or volatility-dependent bias.

Binns, W. R.↗

A TM Tasseled Cap equivalent transformation for reflectance factor data

A transformation of TM-waveband reflectance-factor data which provides features related as directly as possible to the corresponding TM Tasseled Cap brightness, greennes, and wetness features is presented. The reflectance factor transformation is based on spectrometer data integrated over the prelaunch composite-detector response functions of the Landsat-4 Thematic Mapper. A description, in general terms, of the approach for adjusting the transformation matrix to other types of reflectance factor data (different instrument or band response) is given.

Crist, E. P.↗

Cosmic-ray backgrounds in infrared bolometers

Model calculations for the production of cosmic ray events in IR detectors by energy impulses due to fast charged particles' ionization trails are presently compared to the pulse-amplitude spectrum observed from a balloon at an altitude of 38 km. The results are pertinent to the current understanding of cosmic ray backgrounds found in all high sensitivity bolometer applications. The observed signal transients are in all details consistent with the modeling of known cosmic charged particle flux characteristics and with the detector response. Generally, the optics design should minimize detector/substrate cross section.

Nolt, I. G.↗

IRAC test report. Gallium doped silicon band 2: Read noise and dark current

A direct readout infrared detector array, a candidate for the Space Infrared Telescope Facility (SIRTF) Infrared Array Camera (IRAC), has been tested. The array has a detector surface of gallium doped silicon, bump bonded to a 58x62 pixel MOSFET multiplexer on a separate chip. Although this chip and system do not meet all the SIRTF requirements, the critically important read noise is within a factor of 3 of the requirement. Significant accomplishments of this study include: (1) development of a low noise correlated double sampling readout system with a readout noise of 127 to 164 electrons (based on the detector integrator capacitance of 0.1 pF); (2) measurement of the readout noise of the detector itself, ranging from 123 to 214 electrons with bias only (best to worst pixel), and 256 to 424 electrons with full clocking in normal operation at 5.4 K where dark current is small. Thirty percent smaller read noises are obtained at a temperature of 15K; (3) measurement of the detector response versus integration time, showing significant nonlinear behavior for large signals, well below the saturation level; and (4) development of a custom computer interface and suitable software for collection, analysis and display of data.

Lamb, Gerald↗

Airborne imaging spectrometer-2 - Radiometric spectral characteristics and comparison of ways to compensate for the atmosphere

The reduction of AIS data to spectral radiance utilizing the detector responsivity equations developed by a laboratory calibration of the instrument with a BaSO4-coated integrating sphere is described. Estimates of the signal-to-noise ratio for laboratory and flight conditions are obtained. In addition, the effective in-flight instrumental spectral sampling interval is estimated by using atmospheric CO2 absorption lines generated from LOWTRAN simulations.

Conel, James E.↗

A maximum correlation method for image construction of IRAS survey data

An algorithm is presented for the construction of images using linear array data with nonuniform scan coverage of object space and nonuniform detector responses. The algorithm achieves the maximum correlation between adjacent pixels, i.e., the smoothest image, consistent with the data and data uncertainties. For high spatial data density and signal-to-noise ratio, the achievable spatial resolution can exceed the diffraction limit of the optics. The capability of the algorithm is illustrated using 60-micron data from the region centered on the galaxy M101, obtained during the all-sky survey performed by the Infrared Astronomical Satellite. The 60-micron map produced has a resolution of about 36 arcsec and allows the identification of many H II regions by position and aperture photometry for the brighter ones. The achieved resolution is discussed in terms of the a priori estimate of the mean correlation length of the data, the directly measured FWHM in the final image, and the results of aperture photometry of M101 H II regions NGC 5447, 5455, 5461, 5462 and 5471.

Aumann, H. H.↗

Development of large CCD arrays with enhanced UV performance

A development status evaluation is presented for proprietary UV-range CCDs for military and scientific applications requiring pixel sizes in the 18-micron range. The most recent developments in UV/X-ray responsive detectors have their bases in the backside illumination of multipinned phase (MPP) 1024 x 1024 CCD arrays, as well as in the initial exploration of open-pinned phase (OPP) techniques. The frontside performance of both MPP and OPP devices is noted to be excellent as well, and pinouts and mounting techniques have been defined which allow easy front-back operation comparisons. Novel backside processing techniques are being refined.

Varian, Richard H.↗

Pyroelectric detectors

The multi-agency, long-term Global Change programs, and specifically NASA's Earth Observing system, will require some new and advanced photon detector technology which must be specifically tailored for long-term stability, broad spectral range, cooling constraints, and other parameters. Whereas MCT and GaAs alloy based photovoltaic detectors and detector arrays reach most impressive results to wavelengths as long as 12 microns when cooled to below 70 K, other materials, such as ferroelectrics and pyroelectrics, appear to offer special opportunities beyond 12 microns and above 70 K. These materials have found very broad use in a wide variety of room temperature applications. Little is known about these classes of materials at sub-room temperatures and no photon detector results have been reported. From the limited information available, researchers conclude that the room temperature values of D asterisk greater than or equal to 10(exp 9) cm Hz(exp 1/2)/W may be improved by one to two orders of magnitude upon cooling to temperatures around 70 K. Improvements of up to one order of magnitude appear feasible for temperatures achievable by passive cooling. The flat detector response over a wavelength range reaching from the visible to beyond 50 microns, which is an intrinsic advantage of bolometric devices, makes for easy calibration. The fact that these materials have been developed for reduced temperature applications makes ferro- and pyroelectric materials most attractive candidates for serious exploration.

Haller, Eugene E.↗

Minimum length Pb/SCIN detector for efficient cosmic ray identification

A study was made of the performance of a minimal length cosmic ray shower detector that would be light enough for space flight and would provide efficient identification of positions and protons. Cosmic ray positions are mainly produced in the decay chain of: Pion yields Muon yields Positron and they provide a measure of the matter density traversed by primary protons. Present positron flux measurements are consistent with the Leaky Box and Halo models for sources of cosmic rays. Abundant protons in the space environment are a significant source of background that would wash out the positron signal. Protons and positrons produced very distictive showers of particles when they enter matter; many studies have been published on their behavior on large calorimeter detectors. The challenge is to determine the minimal material necessary (minimal calorimeter depth) for positive particles identification. The primary instrument for the investigation is the Monte Carlo code GEANT, a library of programs from CERN that can be used to model experimental geometry, detector responses and particle interaction processes. The use of the Monte Carlo approach is crucial since statistical fluctuations in shower shape are significant. Studies conducted during the 1988 summer program showed that straightforward approaches to the problem achieved 85 to 90 percent correct identification, but left a residue of 10 to 15 percent misidentified particles. This percentage improved to a few percent when multiple shower-cut criteria were applied to the data. This summer, the same study was extended to employ several physical and statistical methods of identifying response of the calorimeter and the efficiency of the optimal shower cuts to off-normal incidence particle was determined.

Snyder, H. David↗

HEAO 1 A-2 low-energy detector X-ray spectra of the Cygnus Loop

The Cygnus Loop supernova remnant was observed by the A-2 low-energy detector (LED) proportional counters on the HEAO 1 satellite. Recent improvements to the non-X-ray background rejection and detector response simulation have allowed production of the most accurate spectra of the Cygnus Loop to date. Three separate regions of the Cygnus Loop were observed. Single-temperature, Raymond-Smith models are inadequate to describe the spectra, but two component model fits are good. Temperature, column density, and emission measure variations across the Cygnus Loop are found. These results are interpreted and compared with previous work.

Leahy, D. A.↗