Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Simulations of plasma current induced by toroidal field ramping down on tokamaks

In tokamak experiments, the BT ramping down can drive off-axis and parallel inductive current. This approach leads to a decrease in q95 and an increase in normalized beta, βN. The off-axis inductive current also broadens the current profile. Typically, the 1.5D transport code is used to simulate the time evolution of the plasma current profile, which is based on the flux-surface-averaged Faraday’s law. The ONETWO code is one of those transport codes. However, this code cannot simulate the situation of the evolving toroidal field BT. This article proposes a new time-dependent model to take into account the BT ramping down situation. A modified formula of flux-surface-averaged Faraday’s law was derived to consider the effect of the BT ramping rate on the current evolution, and it was implemented in the ONETWO code. Then, the modified ONETWO code was used to simulate the BT ramping down experiment on DIII-D. The simulation result of the plasma current evolution with BT ramping down shows a broader current profile with smaller ohmic current induced by the poloidal field, compared to that without BT ramping down.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictions of m/n = 2/1 neoclassical tearing mode stabilization via high field side lower hybrid current drive on the DIII-D tokamak

Neoclassical tearing modes (NTMs) are a class of resistive instabilities that arise in tokamaks at rational surfaces and form magnetic islands. These islands flatten the pressure gradient, reducing plasma performance and may lead to disruptions if they grow large enough. Driving current within the island can stabilize the NTM, which has been achieved with electron cyclotron current drive (ECCD) on multiple devices. An alternative to ECCD is lower hybrid current drive (LHCD), which offers the advantages of increased current drive efficiency and reduced system cost. LHCD has been viewed as poorly suited for NTM suppression due to the large spatial extent of the driven current when in the multi-pass absorption regime (as has been the case in all past LHCD experiments). However, the driven current is more localized when in the single pass absorption regime, as is predicted for the DIII-D high field side (HFS) LHCD experiment. This work evaluates the feasibility of NTM suppression with HFS LHCD on DIII-D by predicting the island growth rate for a set of representative DIII-D plasmas via the modified Rutherford equation with and without the application of LHCD. In these plasmas, NTM suppression is achieved at reasonable power levels, even with finite misalignment between LH current and the island. The effect of current condensation was included and found to be most significant at smaller island sizes, assuming an experimentally typical temperature perturbation amplitude of 10%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First simultaneous observation of co- and counter-current fast-ion losses in the ASDEX Upgrade tokamak

In ITER and future fusion power plants, the source of the fusion born alpha particles is almost isotropic in pitch angle, thus having co- and counter-current populations. For trapped ions, the co-current side of the orbit corresponds to its outer leg, while the counter-current side corresponds to the inner leg. Understanding the mechanisms responsible for the fast-ion losses (FILs) is critical for future magnetically confined fusion power plants. To further study the interplay of fast ions with plasma instabilities, a double pinhole collimator has been developed for a Fast-Ion Loss Detector (FILD) in the ASDEX Upgrade tokamak (AUG). This new FILD opens the operational window to simultaneous measurements of the co- and counter-current ion velocity-space. In this paper, the first results for the AUG double collimator FILD detector are shown. The commissioning of this new probe is carried out in H-mode plasmas with an on-axis magnetic field $B_0 = -2.5$ T, and a plasma current $I_{\textrm{p}} = 0.7$ MA. Simultaneous co- and counter-current FILs have been measured. Both have shown a similar dependence on Ion Cyclotron Resonance Heating (ICRH) power, where the main difference is the intensity of the losses, with the co-losses being an order of magnitude larger. Toroidal Alfvén eigenmode-coherent ICRH-only losses have been identified for the co-current ions. Additionally, the presence of Edge Localized Modes during the discharge were shown to increment Neutral Beam Injection prompt losses, while partially mitigating ICRH-driven losses on both co- and counter- sides of the velocity-space. Finally, a very trapped and high gyroradius losses, with an unclear origin, have been measured in the co- and counter-current velocity-space. The computed ion trajectories show that these ions remain permanently near the vessel wall, suggesting that they are accelerated within the scrape-off layer.

ELM↗

Phonon-Assisted Ballistic Current from First-Principles Calculations

The bulk photovoltaic effect (BPVE) refers to current generation due to illumination by light in a homogeneous bulk material lacking inversion symmetry. In addition to the intensively studied shift current, the ballistic current, which originates from asymmetric carrier generation due to scattering processes, also constitutes an important contribution to the overall kinetic model of the BPVE. In this Letter, we use a perturbative approach to derive a formula for the ballistic current resulting from the intrinsic electron-phonon scattering in a form amenable to first-principles calculation. We then implement the theory and calculate the ballistic current of the prototypical BPVE material BaTiO 3 using quantum-mechanical density functional theory. The magnitude of the ballistic current is comparable to that of the shift current, and the total spectrum (shift plus ballistic) agrees well with the experimentally measured photocurrents. Furthermore, we show that the ballistic current is sensitive to structural change, which could benefit future photovoltaic materials design.

14 SOLAR ENERGY↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

Hydropower Geotechnical Foundations: Current Practice and Innovation Opportunities for Low-Head Applications

Hydropower is a renewable energy resource that produces electricity from flowing water under pressure. Engineered hydropower structures, such as dams, are used to create a hydraulic head, enabling a turbinegenerator unit to convert pressurized flow into electricity. While hydropower has been a source of renewable energy since antiquity, new development in the United States has slowed in recent decades. Based on recent resource assessments, the largest opportunity to expand hydropower in the United States is from new stream-reach development (i.e., new hydropower development along stream-reaches that do not currently have hydroelectric facilities or other forms of infrastructure, such as dams). Roughly 75% of identified new stream-reach development potential is from low-head sites (less than 30 ft of head), which typically suffer from smaller power densities and higher normalized costs, given economies of scale. Hydropower developers and other stakeholders are thus interested in strategies to reduce initial capital costs while practicing sustainable development to maximize environmental compatibility with minimal disruption to natural aquatic life, sediment, and water flows. Historically, civil works have represented a significant cost driver for new hydropower development, with the foundation system representing a major cost component and source of uncertainty. The foundation system is the collection of engineered structural features (e.g. cutoff trenches, walls, grouting, anchors) constructed at or below the preconstruction ground surface that interfaces between the overlying structures (superstructures) and the bed material below (subsurface). Development of a hydropower foundation system must consider the various characteristics of the surrounding stream environment and subsurface while adhering to the engineering requirements of the superstructure that it supports. The care of water, excavation, and other construction activities are important features of foundation design and construction. The design and construction cost of the foundation system is largely dependent on the site geology and riverbed composition and is influenced by the level of geotechnical assessment required and conducted. Thus, a hydropower facility’s geotechnical foundation is often highly site-specific, with proper site selection and assessment being important to project success. The foundation system is designed to provide structural stability (of the foundation and dam), limit seepage, ensure public safety, and maintain functionality for the project life, during both construction and facility operations. Inadequate foundation or dam design can result in dam failure and the uncontrolled release of significant volumes of water, which could cause a high number of casualties and extensive property damage downstream of the failure. According to the Association of State Dam Safety Officials, approximately 30% of all historical dam failures in the United States are attributed to foundation or abutment defects, and another 20% are attributed to piping or seepage through the embankment, foundation, or abutment. To ameliorate these safety considerations, foundations often require massive amounts of construction material (e.g., grout, concrete, engineered dam fill) and long construction times. Foundation design also requires significant analysis prior to construction because the initial in-stream and abutment subsurface conditions are site-specific, and sufficient data for them often are lacking. Current practice requires on-site assessment, using expensive drilling and invasive and non-invasive investigation methods, to determine the expected cost of foundation material and treatment. Additionally, foundation construction often requires site dewatering (and other care of water activities), which involves constructing temporary diversion structures upstream and often downstream, called cofferdams, and water diversion systems that route water around the construction site. Cofferdams and water diversion systems can drastically increase construction costs and contribute to environmental disruption, including modification of flow patterns and benthic habitats. Given the technical, economic, and environmental challenges associated with hydropower foundations, opportunities exist to improve the current state of practice and to develop new and innovative solutions to Hydropower is a renewable energy resource that produces electricity from flowing water under pressure. Engineered hydropower structures, such as dams, are used to create a hydraulic head, enabling a turbinegenerator unit to convert pressurized flow into electricity. While hydropower has been a source of renewable energy since antiquity, new development in the United States has slowed in recent decades. Based on recent resource assessments, the largest opportunity to expand hydropower in the United States is from new stream-reach development (i.e., new hydropower development along stream-reaches that do not currently have hydroelectric facilities or other forms of infrastructure, such as dams). Roughly 75% of identified new stream-reach development potential is from low-head sites (less than 30 ft of head), which typically suffer from smaller power densities and higher normalized costs, given economies of scale. Hydropower developers and other stakeholders are thus interested in strategies to reduce initial capital costs while practicing sustainable development to maximize environmental compatibility with minimal disruption to natural aquatic life, sediment, and water flows. Historically, civil works have represented a significant cost driver for new hydropower development, with the foundation system representing a major cost component and source of uncertainty. The foundation system is the collection of engineered structural features (e.g. cutoff trenches, walls, grouting, anchors) constructed at or below the preconstruction ground surface that interfaces between the overlying structures (superstructures) and the bed material below (subsurface). Development of a hydropower foundation system must consider the various characteristics of the surrounding stream environment and subsurface while adhering to the engineering requirements of the superstructure that it supports. The care of water, excavation, and other construction activities are important features of foundation design and construction. The design and construction cost of the foundation system is largely dependent on the site geology and riverbed composition and is influenced by the level of geotechnical assessment required and conducted. Thus, a hydropower facility’s geotechnical foundation is often highly site-specific, with proper site selection and assessment being important to project success. The foundation system is designed to provide structural stability (of the foundation and dam), limit seepage, ensure public safety, and maintain functionality for the project life, during both construction and facility operations. Inadequate foundation or dam design can result in dam failure and the uncontrolled release of significant volumes of water, which could cause a high number of casualties and extensive property damage downstream of the failure. According to the Association of State Dam Safety Officials, approximately 30% of all historical dam failures in the United States are attributed to foundation or abutment defects, and another 20% are attributed to piping or seepage through the embankment, foundation, or abutment. To ameliorate these safety considerations, foundations often require massive amounts of construction material (e.g., grout, concrete, engineered dam fill) and long construction times. Foundation design also requires significant analysis prior to construction because the initial in-stream and abutment subsurface conditions are site-specific, and sufficient data for them often are lacking. Current practice requires on-site assessment, using expensive drilling and invasive and non-invasive investigation methods, to determine the expected cost of foundation material and treatment. Additionally, foundation construction often requires site dewatering (and other care of water activities), which involves constructing temporary diversion structures upstream and often downstream, called cofferdams, and water diversion systems that route water around the construction site. Cofferdams and water diversion systems can drastically increase construction costs and contribute to environmental disruption, including modification of flow patterns and benthic habitats. Given the technical, economic, and environmental challenges associated with hydropower foundations, opportunities exist to improve the current state of practice and to develop new and innovative solutions to challenges frequently encountered with traditional approaches. With this understanding, it is critically important to understand and document the current state of practice for hydropower geotechnical foundations, identify key challenges, and define opportunities for innovative solutions. To this end, this report documents the current state of practice across the three main phases of geotechnical foundation development: (1) geotechnical site assessment, (2) design, and (3) construction for hydropower systems. It also describes the major challenges with conventional approaches and identifies opportunities for innovation to reduce hydropower foundations costs, timelines, and risks. Key takeaways from this report include the following: Approximately 80% of available low-head sites are expected to have foundations on soil beds rather than rock beds, suggesting that rockfill and earthfill dams may be the most cost-effective conventional dam type for new projects.; Geotechnical and geologic investigation activities are time-consuming and expensive but are essential to define the parameters and criteria needed for foundation design.; Certain riverbed soil and bedrock types present significant technical challenges or require expensive foundation construction, which can prove financially prohibitive for low-head project development.; Modular hydropower design and prefabricated modular foundations represent a promising but unproven paradigm for new hydropower development. Design and construction approaches using optimized and highly repeatable, reliable components would benefit project cost, time, and risk but require additional research and development.; Temporary construction features for foundations, including cofferdams, water diversion, and water control systems, can prove costly and have inherent construction risk.; For economically viable development, hydropower geotechnical foundations should be limited to 4 to 15% of the project’s total initial capital costs. Many proposed projects have experienced cost overruns attributable to foundation difficulties or surprises during construction. These overruns may have been due to inadequate investigations, lack of adequate engineering effort to tailor the structures to site geology and topography, and/or contractual terms, among other considerations.; Challenges for hydropower foundations and opportunities for innovative technology solutions are identified in the following areas (consistent with the three main phases of foundation development): Geotechnical site assessment, Foundation design and materials, Construction methods and technology. Ultimately, this report aims to provide information about geotechnical foundations for low-head hydropower and to motivate transformative technologies to support hydropower growth.

13 HYDRO ENERGY↗

Matrix converter operation in current control mode with regulation of output voltage vector

A matrix converter system having a current control mode operation is provided. The matrix converter system includes a matrix converter that includes a plurality of switches. A unity current reference vector having an amplitude of one is determined that defines an angle and frequency of an output current vector as a function of a reference phase angle, which is a function of the output current vector and an output voltage vector representing feedback signals of a multiphase signal output to a load. The unity current reference vector is used to control the matrix converter, to cause the output current vector to be aligned with the unity current reference vector. A unity voltage reference vector having an amplitude of one is provided that defines a reference angle and frequency as a function of a zero phase angle. The output voltage vector and the unity voltage reference vector are aligned to determine the reference phase angle as an angle between the aligned output voltage vector and the output current vector.

42 ENGINEERING↗

DC input current ripple reduction in SRM drive for high volumetric power density applications

A control system for a switched reluctance machine includes a capacitor and an inverter connected to the capacitor, wherein the inverter generates current signals and a ripple current returned to the capacitor. A switched reluctance machine (SRM) receives the current signals and generates a position signal. A controller receives the ripple current, current signal values of the current signals, and the position signal and generates desired reference current waveforms received by the inverter to adjust the current signals received by the SRM.

Sozer, Yilmaz↗

Characteristics of upward-connecting-leader current leading to attachment in downward negative cloud-to-ground lightning strokes

For this work, we analyzed currents associated with upward connecting leaders (UCLs) initiated from the Kennedy Space Center Industrial Area Tower in two negative cloud-to-ground strokes that struck the tower. One stroke was also recorded using a high-speed video camera located 760 m from the KSC IAT. The NLDN-reported peak currents for the two strokes were – 31.7 and – 98.5 kA. During the UCL development phase the current waveforms exhibited a monotonically (quasi-exponentially) increasing “background” current overlaid with 10-μs scale pulses with a median amplitude of 51.1 A. The UCL current durations for the two strokes were 1039 and 449 μs, respectively. During the pre-attachment processes (UCL and slow front) the total negative charge effectively transferred to ground were 70.2 and 55 mC, respectively. For the stroke captured on high-speed video, the average line-charge-density for the 109-m long UCL was found to be 0.5 mC/m. The average UCL 2-D speed was 2.4 × 10 5 m/s, and it was observed to accelerate toward the downward leader prior to attachment. We observed that UCL-pulse amplitudes are larger, background currents are higher, and interpulse intervals are shorter at later times during UCLs, which can be attributed to the intensification of the local electric field due to the approaching downward negative leader. The median positive charge injected into the UCL by a pulse was 297 μC. The UCL associated with the higher peak-current stroke produced the highest injected pulse-charge values about three times sooner during its development, likely due to the 2–2.7 times faster average downward leader vertical speeds.

54 ENVIRONMENTAL SCIENCES↗

A lightweight and metal-free current collector for battery anode applications

The requirement for high energy density batteries is driving the development of high-capacity electrode materials while reducing the amount of inactive battery components such as separators, binders, and current collectors. Though current collectors are an inactive component, they are still required for successful working of a battery cell. Conventional current collectors include aluminum foil for cathode and copper foil for anode. Copper foil is quite heavy (8.7 mg/cm 2 ) for 10μm thickness. Therefore, there is a need for a lightweight current collector for anode applications. In this work, a metal-free current collector comprised of aligned carbon fiber (CFs) layer filled with carbon nanotubes (CNTs) mixed in polymer (P) is developed to be used as a current collector for anodes. Further, anodes coated on the CF-CNT-P showed lower charge transfer resistance and improved rate capability compared with the anodes fabricated on conventional copper foil-based current collectors. The CF-CNT-P are lighter (≈1.5 mg/cm 2 ) than the commonly used copper foil (8.7 mg/cm 2 ), which will increase the gravimetric energy density.

25 ENERGY STORAGE↗

Aligned carbon fibers-carbon nanotube-polymer-based composite as lithium-ion battery current collector

High energy density demand is pushing the development of high-voltage cathode materials, which necessitates improved electrochemical stability of other battery components such as binders, electrolytes, and current collectors. Current collectors are considered to be an inactive component but still play an essential role. In this study, a metal-free composite film containing directionally aligned carbon fiber (CF), carbon nanotube (CNT), and polymer (P) was developed to replace aluminum foil as a cathode current collector, which relies on forming an Al 2 O 3 layer to ensure electrochemical stability at high voltage. Here, each component in the new cathode current collector played a functional role. The CNTs provided uniform current densities, and CFs improved the electronic conductivity and mechanical strength of the composite material. The polymer enhanced the adhesion of the cathode coating with the current collector and provided an impervious support to the cathode materials. The CF-CNT-P composite demonstrated excellent electrochemical and thermal stability. Cathodes coated on the CF-CNT-P composite exhibited lower charge transfer resistance, improved rate capability, and improved cyclic stability compared with the cathodes deposited on conventional aluminum foil. Additionally, the composite current collector was lighter (1.81 mg/cm 2 and 15 µm thick) than the commonly used aluminum foil (4.35 mg/cm2 and 15 µm thick), which can increase the cell energy density. Additionally, the CF-CNT-P did not need to be separated from the cathode coating during recycling and can be burnt out with binder, simplifying the recycling process.

25 ENERGY STORAGE↗

Non-uniform longitudinal current density induced power saturation in GaAs-based high power diode lasers

The output power of modern 975 nm GaAs-based broad area diode lasers is limited by increasing carrier and photon losses at high bias. Here, we use experiment and one-dimensional calculations on these devices to reveal that higher current densities (and hence higher local recombination rates and higher losses) arise near the front facet due to spatial hole burning and that the non-uniformity is strongly affected by laser geometry, which is more severe for longer resonators and less severe for higher front facet reflectivity. Specifically, we use devices with a segmented p-contact to directly measure the current distribution along the resonator and compare this with laser simulation. Devices with a 6 mm resonator show 29% more current at the front than back, twice as large as the 15% current non-uniformity in devices with a 3 mm resonator. In contrast, increased front facet reflectivity (20% rather than 0.8%) is shown to almost halve the current non-uniformity from 29% to 18% in devices with a 6 mm resonator and reduces power saturation. Although the magnitude of current non-uniformity in experiment and theory is broadly consistent, in experiment, an additional divergence is seen in current flow (and hence recombination rate) near the facets, and earlier power saturation occurs. Finally, we discuss the possible saturation mechanisms that are not included in the simulation.

47 OTHER INSTRUMENTATION↗

Light-induced shift current vortex crystals in moiré heterobilayers

Transition metal dichalcogenide (TMD) moiré superlattices provide an emerging platform to explore various light-induced phenomena. Recently, the discoveries of novel moiré excitons have attracted great interest. The nonlinear optical responses of these systems are however still underexplored. Here, we report investigation of light-induced shift currents (a second-order response generating DC current from optical illumination) in the WSe 2 /WS 2 moiré superlattice. We identify a striking phenomenon of the formation of shift current vortex crystals—i.e., two-dimensional periodic arrays of moiré-scale current vortices and associated magnetic fields with remarkable intensity under laboratory laser setup. Furthermore, we demonstrate high optical tunability of these current vortices—their location, shape, chirality, and magnitude can be tuned by the frequency, polarization, and intensity of the incident light. Electron-hole interactions (excitonic effects) are found to play a crucial role in the generation and nature of the shift current intensity and distribution. Our findings provide a promising all-optical control route to manipulate nanoscale shift current density distributions and magnetic field patterns, as well as shed light on nonlinear optical responses in moiré quantum matter and their possible applications.

36 MATERIALS SCIENCE↗

Quench protection for high-temperature superconductor cables using active control of current distribution

Superconducting magnets of future fusion reactors are expected to rely on composite high-temperature superconductor (HTS) cable conductors. In presently used HTS cables, current sharing between components is limited due to poorly defined contact resistances between superconducting tapes or by design. The interplay between contact and termination resistances is the defining factor for power dissipation in these cables and ultimately defines their safe operational margins. However, the current distribution between components along the composite conductor and inside its terminations is a priori unknown, and presently, no means are available to actively tune current flow distribution in real-time to improve margins of quench protection. Also, the lack of ability to electrically probe individual components makes it impossible to identify conductor damage locations within the cable. In this work, we address both problems by introducing active current control of current distribution between components using cryogenically operated metal-oxide-semiconductor-field-effect transistors (MOSFETs). We demonstrate through simulation and experiments how real-time current controls can help to drastically reduce heat dissipation in a developing hot spot in a two-conductor model system and help identify critical current degradation of individual cable components. Finally, prospects of other potential uses of MOSFET devices for improved voltage detection, AC loss-driven active quench protection, and remnant magnetization reduction in HTS magnets are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient ECCD non-inductive plasma current start-up, ramp-up, and sustainment for an ST fusion reactor

The elimination of the need for an Ohmic heating solenoid may be the most impactful design driver for the realization of economical compact fusion tokamak reactor systems. However, this would require fully non-inductive start-up and current ramp-up from zero plasma current and low electron temperature of sub-keV to the full plasma current of ~10–15 MA at 20–30 keV electron temperature. To address this challenge, an efficient solenoid-free start-up and ramp-up scenario utilizing a low-field-side-launched extraordinary mode at the fundamental electron cyclotron harmonic frequency (X–I) is proposed, which has more than two orders of magnitude higher electron cyclotron current drive (ECCD) efficiency than the conventional ECCD for the sub-keV start-up regime. A time dependent model was developed to simulate the start-up scenarios. For the Spherical Tokamak Advanced Reactor (STAR) (Menard et al 2023 Next-Step Low-Aspect-Ratio Tokamak Design Studies (IAEA)), it was found that to fully non-inductively ramp-up to 15 MA, it would take about 25 MW of EC power at 170 GHz. Because of the relatively large plasma volume of STAR, radiation losses must be considered. It is important to make sure that high Z impurities are kept sufficiently low during the early current start-up phase where the temperature is sub-keV range. Since the initial current ramp up takes place at a factor of ten lower density compared to the sustained regimes, it is important to transition into a higher bootstrap fraction discharge at lower density to minimize the ECCD power requirement during the densification. For the sustainment phase an array of eight gyrotron launchers with a total of about 60 MW of fundamental O-mode was found to be sufficient to provide the required axis-peaked external current drive. High efficiencies between 19–57 kA MW –1 were found with optimal aiming, and these were resilient to small changes in aiming angles and density and temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF

This article presents a voltage injection-based current harmonic minimization method for wide bandgap device-based six-phase permanent magnet synchronous machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct ac component to synchronous reference frame (SRF) dc transformation is not possible for ZSC. In this article, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for 6n ± 1 (n = 1, 2,...) order harmonic current reduction, SRF current controllers are presented in this article. Furthermore, the current harmonics minimization method is experimentally verified using a GaN-based three-level active neutral point clamped inverter-driven six-phase PMSM.

42 ENGINEERING↗

The Grid Value of Ocean Current Energy in Florida

Ocean current energy technology has been proposed as a potential contributor to Florida's energy portfolio. There has been limited investigation of how this energy would be valued when integrated into the Florida electrical grid. This study assesses three future grid scenarios to evaluate the impact of adding zero-cost ocean current energy to each. The Resource Planning Model, a tool developed by the National Renewable Energy Laboratory, is used to identify the least-cost generation mix through 2050, with and without ocean current energy. The first scenario is a base case and assumes existing policies in which the addition of ocean current energy does not retire fossil-based technologies but variable generation technologies. In the second scenario, solar and storage technologies are lower cost, and the addition of ocean current generation enables those technologies along with wind to retire existing natural gas units earlier. In the third scenario, which requires a 95% reduction in carbon emissions from 2020 levels by 2050, ocean current energy can play a role in decarbonization along with other variable generation technologies. This analysis is intended to inform stakeholders on the opportunity, potential challenges, and overall value to the grid of ocean current technology from a reliability and availability focused perspective.

capacity expansion model↗