Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Comparison of the Distribution of the In Situ Ring Current Density Based on Magnetic Field Observations From THEMIS, MMS and Cluster

Abstract We review and extend previous work on the ring current density distribution by applying the curlometer technique to multi‐spacecraft magnetic field data on different spatial scales, directly comparing the results of three space missions: Time History of Events and Macroscale Interactions during Substorms (THEMIS), The Magnetospheric Multiscale (MMS) and Cluster, that have so far accrued decades of data on a range of spatial separation scales. We suggest that the statistical results of Cluster data over two decades can illustrate well the overall form of the ring current (in the ring plane), but can underestimate the current density, while THEMIS (partially) and MMS are able to observe the detailed structure of the ring current and indeed show different behavior on some (smaller) spatial scales. These results suggest that, in addition to the local time and radial form, reported previously, the morphology of the ring current may also depend on magnetic latitude, as influenced by the tilt angle between the inner and outer magnetic fields.

Tan, X. [School of Space and Earth Sciences Beihan↗

Current and Projected Future Distribution of Plant Community Types for the Southern Seward Peninsula, Alaska

Landscape scale maps of plant community distribution at 5 m resolution were developed for southern Seward Peninsula. A Random Forest based environmental niche model was developed using topographic and climate data sets. Models were trained for the 2010-2019 period and applied to develop plant community distributions for contemporary (2010-2019) period. Trained model was applied to project the plant community distributions under future climate. Using downscaled projections for RCP8.5 scenario from five climate models (CCSM4, GFDL-CM3, GISS-E2-R, IPSL-CM5A-LR, MRI-CGCM3) and multi-model mean, a six member ensemble of plant community distribution were developed for current decade (2010-2019) and for future decades (2020-2029, 2030-2039, 2040-2049, 2050-2059). Contains *.tif and *.sh files. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Finite Element Analysis and Techno-economic Modeling of Solar Silicon Molten Salt Electrolysis

A new process is presented for low-cost one-step production of pure solid silicon from natural quartzite by molten salt electrolysis. At a process temperature of 1100°C, a techno-economic model including detailed mass and energy balances estimates energy consumption below 15 kWh/kg, with operating cost of $\$1.74$/kg and capital cost around $\$10,500$ per t/a (tonne annually) of production capacity for a 160,000 t/a plant. Use of an inert solid oxide membrane anode results in a pure oxygen by-product and no direct emissions. As a result, finite element analysis estimates the current density distribution and total current to inform the design of slab-shaped solid silicon cathodes.

14 SOLAR ENERGY↗

Current Practices in Distribution Utility Resilience Planning for Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using Institute of Electrical and Electronics Engineers (IEEE) 1366-2022, which defines major events as an event that exceeds reasonable design and/or operational limits of the electric power system. Resilience planning is focused on major event days and reliability planning is focused on nonmajor event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on winter storms in which the primary hazards are heavy snowfall, freezing rain, ice, extreme cold, severe wind, and flooding. These hazards can also contribute to generation shortages, resulting in bulk power system impacts that have consequences for the distribution system, such as load shedding. Stand-alone reports focusing on wildfires and nonwinter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Current Practices in Distribution Utility Resilience Planning for Wildfires

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines major events as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on major event days, and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on wildfires. Standalone reports focusing on severe storms (including hurricanes and non-winter storms) and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Current Practices in Distribution Utility Resilience Planning for Hurricanes and Non-Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines "major events" as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on "major event days" and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common recommended resilience components that we have identified in existing resilience frameworks. The focus of this report is on hurricanes and severe storms in which the primary hazards are precipitation or high winds. We exclude winter storms with primary hazards of ice and extreme cold, as they are a unique set of hazards with different resilience considerations. Standalone reports focusing on wildfires and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution Capacity Expansion Planning: Current Practice, Opportunities, and Decision Support

The distribution utility industry and its engineers are experiencing monumental shifts in consumer needs and expectations. Characterizing future native loads as compared to net load demand for long-term capacity planning is especially difficult, as consumers are increasingly adopting prosumer technologies. This paper is the culmination of 5 months of utility interviews coordinated by the National Renewable Energy Lab (NREL) and Kevala, Inc. (Kevala) to better understand distribution capacity planning challenges. The interviews covered all aspects of capacity planning including load and DER forecasting, criteria for assessing system constraints, solution types, and organizational and decision-making structures. Our intent is to provide insight into distribution capacity planning decision support needs for utilities and the increasing number of stakeholders involved, from state and regulatory agencies to community and solution providers with interest in increasing their understanding in the distribution capacity planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Mapping the global distribution of C 4 vegetation using observations and optimality theory

Plants with the C 4 photosynthesis pathway typically respond to climate change differently from more common C 3 -type plants, due to their distinct anatomical and biochemical characteristics. These different responses are expected to drive changes in global C 4 and C 3 vegetation distributions. However, current C 4 vegetation distribution models may not predict this response as they do not capture multiple interacting factors and often lack observational constraints. Here, we used global observations of plant photosynthetic pathways, satellite remote sensing, and photosynthetic optimality theory to produce an observation-constrained global map of C 4 vegetation. We find that global C 4 vegetation coverage decreased from 17.7% to 17.1% of the land surface during 2001 to 2019. This was the net result of a reduction in C 4 natural grass cover due to elevated CO 2 favoring C 3 -type photosynthesis, and an increase in C 4 crop cover, mainly from corn (maize) expansion. Using an emergent constraint approach, we estimated that C 4 vegetation contributed 19.5% of global photosynthetic carbon assimilation, a value within the range of previous estimates (18–23%) but higher than the ensemble mean of dynamic global vegetation models (14 ± 13%; mean ± one standard deviation). Our study sheds insight on the critical and underappreciated role of C 4 plants in the contemporary global carbon cycle.

54 ENVIRONMENTAL SCIENCES↗

Thickness-Dependent Thermal Conductivity and Phonon Mean Free Path Distribution in Single-Crystalline Barium Titanate

Nanosized perovskite ferroelectrics are widely employed in several electromechanical, photonics, and thermoelectric applications. Scaling of ferroelectric materials entails a severe reduction in the lattice (phonon) thermal conductivity, particularly at sub-100 nm length scales. Such thermal conductivity reduction can be accurately predicted using the information of phonon mean free path (MFP) distribution. The current understanding of phonon MFP distribution in perovskite ferroelectrics is still inconclusive despite the critical thermal management implications. Here, high-quality single-crystalline barium titanate (BTO) thin films, a representative perovskite ferroelectric material, are grown at several thicknesses. Using experimental thermal conductivity measurements and first-principles based modeling (including four-phonon scattering), the phonon MFP distribution is determined in BTO. The simulation results agree with the measured thickness-dependent thermal conductivity. The results show that the phonons with sub-100 nm MFP dominate the thermal transport in BTO, and phonons with MFP exceeding 10 nm contribute ≈35% to the total thermal conductivity, in significant contrast to previously published experimental results. The experimentally validated phonon MFP distribution is consistent with the theoretical predictions of other complex crystals with strong anharmonicity. This work paves the way for thermal management in nanostructured and ferroelectric-domain-engineered systems for oxide perovskite-based functional materials.

36 MATERIALS SCIENCE↗

Cost Analysis Framework for Comparing AC and DC Design Alternatives for Building Electrical Distribution Systems

In recent years, in response to the changing nature of building load, direct current (DC) distribution systems for buildings have been proposed as alternatives to traditional alternating current (AC) systems. DC distribution offers a closer match to the types of loads and generation sources found in modern buildings, the majority of which use DC electricity internally either natively or as a power conditioning stage. The proposed benefits of DC distribution compared to AC distribution within buildings include higher efficiency, lower installation cost, lower operating cost, higher reliability, improved communication and control, and simplicity. Most recent DC distribution research has focused on quantifying the efficiency advantage of DC distribution over AC distribution. However, energy savings alone do not guarantee cost savings; a more complete cost accounting is required to establish financial benefit. This report provides a framework for cost analysis and comparison of building electrical distribution systems, including common variants for both AC and DC distribution systems. The framework includes all major cost categories, including up-front costs (capital, installation labor, soft costs) and long-term costs (energy, operations and maintenance).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EWTN: Quantifying Mass Transport to Enable Water Electrolyzer Architectures with Low Flow-Rate Sensitivity

To develop cost-effective and high-performing polymer electrolyte water electrolyzers (PEWEs) for gigawatt-scale applications, researchers have focused on reducing precious metal catalyst loadings and optimizing porous transport layers. However, the performance of PEWEs is also affected by system architecture. Mass transport losses are dependent on localized architecture and material interactions. In-situ measurements, such as current density distribution maps have demonstrated advantages in understanding the intricate characteristics and influence of two-phase flow within PEWEs. This study proposes the parameter of effective water transport number (EWTN) as a quantitative tool to investigate such current density distribution (CDD) measurements for PEWEs. Results show that higher flow-rates have EWTN values of 0.95 and above, indicating no mass transport limitations; while lower flow-rates with large gradients CDD have EWTN values between 0.6-0.8, indicating mass transport limited conditions. The new analysis also identified a correlation between mass transport losses due to bubble accumulation, membrane hydration, and ohmic overpotentials. To address these limitations, an unitized pin-type LGDL/flow-field design was developed, which effectively prevents local gas phase accumulation, resulting in improved mass transport characteristics. The results of this work show reduced flow-rate sensitivity with the pin-type architecture and ∼13% increased performance at 0.24 ml / min / cm 2 .

Electrochemistry↗

DLMP of Competitive Markets in Active Distribution Networks: Models, Solutions, Applications, and Visions

Traditionally, the electric distribution system operates with uniform energy prices across all system nodes. However, as the adoption of distributed energy resources (DERs) propels a shift from passive to active distribution network (ADN) operation, a distribution-level electricity market has been proposed to manage new complexities efficiently. In addition, distribution locational marginal price (DLMP) has been established in the literature as the primary pricing mechanism. The DLMP inherits the LMP concept in the transmission-level wholesale market but incorporates characteristics of the distribution system, such as high $R/X$ ratios and power losses, system imbalance, and voltage regulation needs. The DLMP provides a solution that can be essential for competitive market operation in future distribution systems. This article first provides an overview of the current distribution-level market architectures and their early implementations. Next, the general clearing model, model relaxations, and DLMP formulation are comprehensively reviewed. The state-of-the-art solution methods for distribution market clearing are summarized and categorized into centralized, distributed, and decentralized methods. Then, DLMP applications for the operation and planning of DERs and distribution system operators (DSOs) are discussed in detail. Finally, visions of future research directions and possible barriers and challenges are presented.

42 ENGINEERING↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗